Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.7 CrAccepted-Finance | ₹6.7 Cr | 1 | Accepted-Finance L1 |
| 2 | 2₹7.4 Cr+₹67.7 L (10.0%)Rejected-Finance 96 ELECTRONIC CITY COMPLEX BANGALORE KARNATAKA 560100 | BENGALURU URBAN | KARNATAKA | 560100 | ₹7.4 Cr+₹67.7 L (10.0%) | 2 | Rejected-Finance L2 |
| 3 | 3₹9.3 Cr+₹2.6 Cr (38.4%)Rejected-Finance 1 6 GOKHLE MARG 1ST FLOOR NEAR RED HILL SCHOOL LUCKNOW LUCKNOW | ₹9.3 Cr+₹2.6 Cr (38.4%) | 3 | Rejected-Finance L3 |
| 4 | Rejected-Technical B 46 INDUSTRIAL AREA SECTOR 59 NOIDA UP 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | - | - | Rejected-Technical Non responsive |
Tender Value
Refer Docs
Closing Date
17 Jan 2022, 4:00 pmClosed
As per Tender document
As per Tender document
Supply, Installation, Testing, Commissioning, Training, Operation and Maintenance of of SCADA based Canal Automation for Nagarjun Sagar Right Main Canal Project, Andhra Pradesh under National Hydrology Project(NHP)
2021_WRDAP_662370_1
NHP/APSW//SCADA/3/2021-22
Open Tender
Electrical Goods/Equipment
Supply
365 days
As per Tender document
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
As per Tender document
2 May 2022
13 Dec 2021
17 Jan 2022
13 Dec 2021
17 Jan 2022
24 Dec 2021
13 Dec 2021 - 17 Dec 2021
17 Dec 2021
Amount
1) Goods as per Shedule of Requirements -Local Control System for NSP Right Main Canal System
Supply of Remote PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet, fitted with Power buses, MCBs and modem. Suitable power supply to power up PLC/RTU panel, including necessary surge protection with 7” or above HMI display and Industrial type electrical fitting and cabling with suitable conduits complete for all related field instruments, as per technical specification.
Supply of Shaft Encoder based rotary position sensor with Digital Display Type Gate Position Sensors for indication and monitoring of canal gates, including cabling and integration with PLC/RTU / Datalogger as per technical specifications.
Supply of Automated Water Level transmitter non-contact Ultrasonic type having 10 m range for measuring level /downstream discharge in canal across the head / cross regulators, including all necessary Mast/ cantilever as per technical specification.
Supply of side looking Acoustic Doppler based Velocity Meter (ADVM) for direct downstream discharge measurement in head /cross regulators of NSP Canal system with bed width of as per the site required, including integration with PLC/RTU/Datalogger complete as per technical specifications.
Supply of Datalogger/RTU with 2 channel and RS485 port for sensor input type with GSM and GPRS based telemetry & enclosure including antenna and all necessary equipment for data transmission from remote monitoring stations, as per technical specifications.
Supply of Datalogger/RTU with 8 channel and RS485 port for sensor input type with GSM and GPRS based telemetry & enclosure including antenna and all necessary equipment for data transmission from remote monitoring stations, as per technical specifications.
Supply of Solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduit & mounting accessories for power back up to Remote PLC/RTU/Datalogger as per technical specifications.
Supply of Battery-operated Water Level Monitoring System using Non-Contact Ultrasonic / RADAR type Water Level Sensor with GPRS/GSM communication system for Canals having measurement range of 0-6 m, along with other ancillary equipment and all necessary mounting hardware, as per technical specifications.
Supply of LTE Surveillance IP based 3G/4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 OR4 Array/72 LED Colour camera. 6 or 8 or 12mm (according to site Supply of LTE Surveillance IP based 3G/4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 OR4 Array/72 LED Colour camera. 6 or 8 or 12mm (according to site suitability) with storage facility of at least 24- hour video recording, in elegant metal Die cast housing. Outdoor weather resistant IP 66, for monitoring the gates operation complete as per Technical Specifications.
Supply & Erection of Pre-Fabricated Green Hut (Hutment) (size 6'x6' and 8' height) with M.S. Angle 50x5, 16-gauge M.S. Sheet, Opening Door, Roof and Floor, Painting etc. complete. The base measuring 7‘x 7‘(6 inches thick) for pre-fabricated green hut should be constructed cement concrete in M 150 grade as per technical specification.
Control Room Equipment’s
Supply of Customized Irrigation Monitoring software which shall include SCADA software for Real time monitoring & Controlling of Canal operations, water scheduling, Real time data logging for complete Canal system with life time licensed version. as per technical specifications.
Supply of Industrial grade server which includes Server with work station server Rack and industrial grade monitor with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to SCADA System complete for Canal System, as per technical specifications.
Supply of Industrial grade Computer node as Workstation along with 42 inch Led display, 1 KVA UPS & 4G/3G dongles/broadband including required software at division monitoring station with necessary accessories as per technical specifications
Supply of Internet connection and IT Hardware which includes required Static IP, Router with modem, Switch, firewall system and A3 colour printer as per technical specifications.
Supply of 110” Smart LED Display System including installation for monitoring of Canal system at Canal SCADA Control Room, as per technical specifications.
Supply of laptops & 4G/3G internet dongles along with licensed version of Client SCADA software for remote viewing & monitoring of Barrage automation as per technical specifications
Supply of Online 3 KVA UPS with Battery system for power back up of Canal SCADA control room equipment’s as per the technical specifications.
Supply of Diesel Generator Set 10 KVA with 04 Earth Pits for earthing at Canal SCADA Control Room.
Supply of Air conditioning system with requisite furniture, Renovation & Furnishing of existing control room for establishment of Canal SCADA Control room along with necessary electrical fittings as per technical specification.
Description of Work / Item(s)
Amount
Related Services as per Shedule of Requirements - Local Control System for NSP Right Main Canal System
S-1 Installation, Testing and commissioning of Remote PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet, fitted with Power buses, MCBs and modem. Suitable power supply to power up PLC/RTU panel, including necessary surge protection with 7” or above HMI display and Industrial type electrical fitting and cabling with suitable conduits complete for all related field instruments, as per technical specification.
S-2 Installation, Testing and commissioning of Shaft Encoder based rotary position sensor with Digital Display Type Gate Position Sensors for indication and monitoring of canal gates, including cabling and integration with PLC/RTU/Datalogger as per technical specifications.
S-3 Installation, Testing and commissioning of Automated Water Level transmitter non-contact Ultrasonic type having 10 m range for measurement of upstream level/downstream discharge in canal across head / cross regulators. including all necessary Mast/ cantilever associated Civil works cabling, conduits and electrical fitting complete as per technical specification.
S-4 Installation, testing and Commissioning of Side looking Acoustic Doppler based Velocity Meter (ADVM) for direct downstream discharge measurement in head/cross regulator of main Canal systems with bed width as per site requirement, including retractable Mounting frame, cabling, integration with PLC/RTU/ Datalogger & associated Civil works complete as per technical specifications
S-5 Installation, Testing and commissioning of RTU/Datalogger with 2 channel and RS485 port for sensor input type, with GSM and GPRS based telemetry & enclosure including antenna and all necessary equipment for data transmission from remote monitoring stations, as per technical specifications.
S-6 Installation, Testing and commissioning of RTU/Datalogger with 8 channel and RS485 port for sensor input type, with GSM and GPRS based telemetry & enclosure including antenna and all necessary equipment for data transmission from remote monitoring stations, as per technical specifications.
S-7 Installation, Testing and commissioning of Solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduit & mounting accessories for power back up to Remote PLC/RTU/Datalogger as per technical specifications.
S-8 Installation, testing & Commissioning of Battery operated Water Level Monitoring System using Non-Contact Ultrasonic / RADAR type Water Level Sensor with GPRS/GSM communication system for Canals having measurement range of 0-6 m, along with other ancillary equipment and all necessary mounting hardware, as per technical specifications.
S-9 Installation, testing and Commissioning & integration of LTE Surveillance IP based 3G/4G Bullet Camera with Sim Card Slot, 2 Mega Pixel 2 OR4 Array/ 72 LED Colour camera. 6 or 8 or 12mm (according to site suitability) with storage facility of at least 24-hour video recording, in elegant metal Die cast housing. Outdoor weather resistant IP 66, communication with NVR located at Barrage control room for monitoring the gates operation complete as per Technical Specifications.
S-10 Repairing & maintenance of pre-installed Green Hut (Hutment) (size 6'x6' and 8' height) with M.S. Angle 50x5, 16-gauge M.S Sheet, Opening Door, Roof and Floor, Painting with all labour material T&P etc. complete for 4 Year as per technical specification.
CONTROL ROOM EQUIPMENTS
S-11 Installation of Customized Irrigation Monitoring software which shall include SCADA software for real time monitoring & Controlling of Canal operations, water scheduling, Real time data logging for complete Canal system with life time licensed version, as per technical specifications.
S-12 Installation, Testing and commissioning of Industrial grade server which includes Server with work station server Rack and industrial grade monitor with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to SCADA System complete for Canal System, as per technical specifications.
S-13 Installation testing & Commissioning of Industrial grade Computer node as Workstation along with 42 inch LED display, 1 KVA UPS & charges for 4G/3G dongles/broadband including required software with One Tara bite Hard drive (1TB) at division control station With necessary accessories as per technical specifications.
S-14 Installation, Testing and commissioning of IT Hardware which includes required Static IP, Router, Switch, firewall system and A3 colour printer at SCADA control room as per technical specifications.
S-15 Charges of High-speed synchronous internet connection (min. 8 mbps upload and download speed) and Static IP for Canal System for 5 years.
S-16 Charges for High speed 4G/3G internet dongle for laptop with Client SCADA software for remote viewing & monitoring of system for five years
S-17 Installation, Testing and commissioning of Online 3 KVA UPS with Battery system for power back up of SCADA control room equipment’s as per the technical specifications.
S-18 Installation, Testing and commissioning of Diesel Generator Set 10 KVA with 04 Earth Pits for earthing at Canal SCADA Control Room.
S-19 Installation, Testing and commissioning of Air conditioning system with requisite furniture, Renovation & Furnishing of existing Control Room for establishment of SCADA Control room long with necessary electrical fittings as per technical specification.
S-20 Five Years Operation & Maintenance and Comprehensive Warranty for SCADA based Canal monitoring & Controlling system with Telemetry along with accessories, installed at designated locations within Canal system after final acceptance of the SCADA systems. This includes replacement of material & consumable as & when required at bidders’ cost. The cost of Communication for GSM & GPRS (SIM & internet charges) telemetry for data transmission shall be borne by bidder. Minimum one Service Engineer shall be placed at Canal SCADA Control Room for Operation of Canal Monitoring & controlling system with telemetry for entire warranty period of 5 years.
S-21 Comprehensive AMC of 2 years for complete SCADA system as per schedule of Rates along with all accessories, installed at designated locations under this contract after 5 years warranty period. This includes the cost of Communication for GSM & GPRS telemetry for data transmission and shall be borne by bidder.
S-22 Training of the purchaser's personnel at the supplier’s plant and/or/onsite in assembly, start up, operation, maintenance and/or repair of the supplied goods. Course topics will include sensor calibration, PLC/RTU/Datalogger and SCADA configuration, data downloading, data retrieval, collection, Trouble shooting, processing maintenance requirements and procedure for equipment configuration, installation, site testing and commissioning including training kit containing course material in soft and hard copies as per technical specification.
BIPS SYSTEMS LIMITED
Yokogawa India Limited
Chetas Control Systems Pvt. Limited.
BIPS SYSTEMS LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .