Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | single₹10.9 LAccepted-Finance | single | Accepted-Finance reasonable rates |
Tender Value
Refer Docs
EMD Value
₹20,939
Closing Date
1 Mar 2021, 3:00 pmClosed
O/o The Executive Engineer(E), BSNL ED-II Vadodara
O/o The Executive Engineer(E), BSNL ED-II Vadodara,2nd floor, E-4 staff quarters, TE Bldg. subhanpura Compound.
Attending faults on call basis for EI Pumps CL DG Set FDFA System Fire fighting system miscellaneous works for various exchanges under EDII Vadodara ESDIII
2021_BSNL_69503_1
08/EEE/BSNL/VDR-II/2020-2021 2nd Call
Open Tender
AMC/ Maintenance Contracts
Item Rate
720 days
Vadodara
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Accounts Officer( Cash)O/oPGMTD Vadodara
₹20,939
Yes
3 Mar 2021
8 Feb 2021
2 Mar 2021
8 Feb 2021
1 Mar 2021
8 Feb 2021
8 Feb 2021 - 1 Mar 2021
Amount
S.H.- I ( Call Basis - DG Set )
Attending the site without material for rectification of minor fault of non functioning of the E/A set i/c removing air lock, checking of the power connection, other faults etc as reqd.( Will be measured only if fault is cleared and DG set is made functional )
Carry out of "B" check of the following capacity DG set of various make i/c replacement of lube oil, element type lube oil filter/screw type lube oil filter, set of fuel filter, air filter, tightening of all nut bolts for arresting all kind of leakages cleaning of the air filter, tapped setting adding distilled water in the battery, checking of the battery etc as reqd. (a) 15 to 32.5 KVA
(b)40 to 62.5 KVA
(c)100 to 125 KVA
(d)160 KVA to 250 KVA
Rewiring of the burnt wires control wirings of the E/A set panel (Manual) i/c replacement of wires, lugs & making connection testing etc as reqd. (a) For E/A set up to 160 KVA
Repairing of the radiator i/c removing the coolant of the radiator ,cleaning the radiator with cleaning solvent ,adding the distilled water & recommended make coolant in the radiator, testing, checking the leakages for all capacities Engine etc as reqd. (a) For E/A set up to 200 KVA
Replacement of universal static electronic type solid state AVR suitable for 1 phase / 3 phase alternator of following capacity, credit of old unit i/c conecting etc as reqd. (a) For E/A set up to 125 KVA
(b) For E/A set 160 KVA to 500 KVA
Rewinding of the rotor of the following capacity alternator of various make with same wire gauge & insulation class "H" i/c credit of burnt winding etc as reqd. (a) 15 to 32.5 KVA
(b) 40 to 62.5 KVA
(c) 100 to 160 KVA
(d) 200 to 320 KVA
Rewinding of the stator the following capacity alternator of various make with same wire gauge & insulation class "H" i/c credit of burnt winding etc as reqd. (a) 15 to 32.5 KVA
(b) 40 to 62.5 KVA
(C) 100 to 160KVA
Rewinding of the stator & rotor exciter of 15 to 32.5 KVA alternator of various make with same wire gauge & insulation class "H" i/c credit of burnt winding etc as reqd. (a) 15 to 32.5 KVA
(b)40 to 62.5 KVA
(C)100 to 250 KVA
Replacement of the Diodes on the diode plate of the 15 to 500 KVA alternator of various make with suitable current capacity diode, making connection testing etc as reqd.
Transportation charges of the alternator / Engine / trolley mounted DG Set from site to the nearest authorised dealer workshop to and fro i/c dismantling & refixing the alternator / Engine at site etc as reqd.
Supplying & fixing of the SMPS type electronic Battery Charger of 10 Amp capacity for all capacites DG set i/c making connection etc as reqd. (i/c 12 V/24V DC)
Repairing of the SMPS type / transformer type Battery Charger of 10 Amp capacity i/c making connection etc as reqd.
Repairing & servicing of the Self starter upto 500 KVA capcity E/A set with supplying & Fixing of the following parts dismantling & refixing at site etc as reqd. (a) Brushes & Spring
(b) Pinion 9 / 11 teeth.
(c) Solenoid relay
(d) Starting relay (Lucas)
Repairing & servicing of the dynamo i/c replacement of the diode kit, dismantling & refixing at site etc as reqd.( For all Capacity E/A set)
Replacement of damaged spider type coupling with Dounlop make set of special bolts for EA sets up to 62.5 KVA etc as reqd
Servicing & arresting leakages of the fuel tank, pulling out the fuel tank from the E/A set canopy & taking it to the welding workshop, carrying out pressure water servicing to clean the fuel tank.i/c transportation & refixing etc as reqd.
Repairing of the bended / damage main shaft to original shape ,cutting the shaft as per requirement & polishing the shaft to make it frictionless & refixing the same etc for DG sets of the following capacity as reqd. (a) 15 to 32.5 KVA
(b) 40 to 62.5 KVA
(c)100 to 125 KVA
Repairing /servicing of the head assembly with grinding & polishing the surface to fix the steel sims for head valve & fixing the valve guide etc for the following capacity DG sets as reqd. (a)For DG sets from 15 KVA up to 50 KVA
For DG sets from 62.5 KVA up to 200 KVA
Calibration of the fuel pump & nozzle from the authorised workshop of Mico dealer dismantling & refixing etc as reqd.( For 2 to 6 Cylinder pump & Nozzle)
Calibration of the fuel pump & nozzle from the authorised workshop of Mico dealer dismantling & refixing etc as reqd.( For for 8 to 12 Cylinder pump & Nozzle)
Supplying & fixing of the following parts of the 15 to 500 KVA E/A set of various make & model but without labour charges, credit of non returning of unserviceable material etc as reqd. (a) Piston with gudgeon pin
(b) Liner
(c) Piston Ring (Set)
(d) Connecting Rod
(e) Connecting Rod Bearing
(f) Main Bearing
(g) Oil seal drive end
(h) Oilseal nondrive end
(i) Full gasket set
(j) Pressure nozzle
(k)Oil pressure switch
(l) Oil temperature switch
(m) Oil pressure guage
(n) Oil temperature guage
(o) Cam shaft bush
(p) Connecting rod bush
(q) Head Valve set (suction & exhaust)
(r) Head valve guide
(s)Gudgeon pin
(t) hose pipe set with clamps for air circuit
(u) hose pipe set with clamps for water circuit
(v) Rocker Arm
(w)Tapped push rod
(x) Cam shaft Trimer
(y) Crank shaft gear
(z) benzo bolt with washer
(aa)Metallic Braided fuel pipe of required length with two sided benzo bolts or one sided benzo bolts and other sided threaded nut.
(ab)Fuel supply hand pump
(ac)3 way benzo pipe
(ad) Water pump
(ae) "V" Belt set
(af) Stop solenoid of 5 Kg pressure (Original make of Manufacturers)
(ag) Radiator fan blade set
(ah) Oil pump in the sump with gear assembly
(ai)Flexible Exhaust bellow
(aj) Rubber type AVM pad
(ak) Diesel shut off valve
(al)Dry type Air filter
(am) Oil sump chamber drain nut with washer
(an)Head gasket set
Major Overhauling labour charges for skilled person for fixing the above parts from 15 KVA upto 50 KVA DG set. (Without "B" check material)
Major Overhauling labour charges for skilled person for fixing the above parts from 62.5 KVA upto 200 KVA DG set. (Without "B" check material)
Supplying & installation of the following capacity 12 Volt low maintenance type lead acid battery along with heavy duty brass leads for above engine including filling initial charging & applying anticorrossive chemical on leads connections testing etc i/c credit of non return of unserviceable old battery as required. ( Make - Excide, prestolite, Standard, furukowa,space sheeter, Amar Raja, Bosch, Hitachi, Kirloskar) (a) 90 AH
Supplying & fixing of the electrical components in the E/A set panel excluding labour charges etc as reqd. (a) Pla relay with base 12 volt DC 8/11pin
(b)Pla relay with base 240 volt AC 8/11 pin
(c) 32 Amp 4 pole contactor
(d) 32 Amp contactor coil
(e) SP MCB 6-32 amp
(f) SPN MCB 32 Amp
(g) TPN MCB 32 Amp
(h) AVR of mains contactor coil range 90 - 270 volt AC
(i) DC Volt meter 72mmX 72mm
(j) DC A meter 72mm X 72mm
(k) AC volt meter 72mm X 72mm
(l) AC ameter 72mm x72mm
(m) RPM cum Hour meter with chain & teco gear.
(n)Battery charger meter
(o) LED type indication lamp with voltage indication ( Red or Yellow or Green )
(p) HRC fuse HN type 6 Amp
(q) Glass fuse 2 Amp
(r) Starting key switch
(s) Push button
(u) 3 way rotatry type c/o switch 63 Amps
(v) CFL / PL type 12 volt DC fitting
(w) Canopy Door lock
(x) RPM cum Hour meter suitable for working on 12 V DC supply.
Labour charges of repairing of DG set panel i/c replacement of some of above parts etc as reqd. (If material cost will be below Rs.1000/-)
Hiring charges of following capacity DG sets including and making necessary connection of the cable, including making necessary associated works etc. complete as required.( Diesel for trolley mounted dg set not included) (a) 50 KVA to 100 KVA Trolley mounted D.G.Set (With in Urban area)
Transportation charges (to and fro) of the above trolley mounted DG Set from the nearest authorised dealer / workshop to the site etc. complete as required. (Only Out side Municipal Corporation / Dist HQ)
Sub Head - II ( Pumps, Compound Lighting & Misc.Works)
Supply of XLPE solid aluminium conductor armoured cable of 1.1 KV grade (ISI mark) of the following size directly on surface of wall / cable tray / existing GI pipe including supplying and fixing clamps, screws , credit of faulty item etc. as reqd. (a) 2C x 06 sq.mm
4C x 10 sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface/cable tray as required. (a) Upto 35 sq. mm
Supplying & Laying of the ISI marked 40 mm dia class "A" GI pipe on surface of wall with suitable heavy gauge MS clamps, screws etc as reqd.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 2C X 6 sq. Mm
4C X 10 sq. mm
Replacement of porcelain fuse cutout (Carrier & Base) of following capacity with rewireable fuse wire etc comp as reqd. (One piece) (a) 63 A
Supplying and fixing / replacement following Rating, 240V/ 415 v 'C' series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning , credit of faulty item etc. as required. (a) 32 A TPN MCB
40 A TPN MCB
5 -32 A SP MCB
5 - 32 A SPN MCB
Supplying and fixing / Replacement of following rating , 240 Volt, residual current circuit breaker (RCCB) sensitivity current upto 300 milliamperes in the existing MCB DB i/c removing faulty unit complete with connections, testing and commissioning etc as required. (a) 40 Amp double pole (single phase and neutral)
(b) 63 Amp four pole ( three phase and neutral)
Rewinding of the following capacity monoblock building water pump / Exh fans with copper conductor H class insulated copper enamalled suitable gauge wire i/c taking to workshop, reinstallation, painting, servicing, credit of burned windings etc as reqd (a) Up to 3 HP 3 phase
(b) 4 to 7.5 HP 3 phase
(c)Single phase Exhaust fans / pedastal fans up to 200 Watts cap
(d) single phase ceilling fans
Rewinding of the following capacity submersible water pump with copper conductor suitable class & gauge insulated copper enamelled wire i/c removeing from the tube well, taking to workshop, reinstallation, credit of burned windings, etc as reqd (a) Up to 3 HP 3 phase
(b) 4 to 7.5 HP 3 phase
Replacement of 3 pole DOL starter suitable for up to 5 HP motor with contactor coil of 230 V supply etc as reqd.
Replacement of existing compound light / street light lamp on pole with 18 Watts LED lamp in the existing fitting with lamp holder etc as reqd.
Supplying and fixing of following MCCB/TPN SFU/accesories in existing LT panel i/c dismantling of existing faulty parts, making connection etc as reqd. (a) 63- 75 A TP MCCB ( 25 KA)
(b) 100/125 A TP MCCB ( 35 KA)
(c) 63 Amp. TPN SFU in open execution i/c HRC fuse link (AC-23 duty)
(d) 125 Amp. TPN SFU in open execution i/c HRC fuse link (AC-23 duty)
(e) 2/4 amp HRC Type control fuse link
(f) 63 Amp. HRC Fuse link.
(g)100/125 Amp. HRC Fuse link.
(h) 200 Amp. HRC Fuse link.
(i)LED type indicating lamps 220 volt AC for R(Red), Y(Yellow) & G(Green) color indication ( Single unit of either colour)
Supplying and fixing of following rating ON LOAD Change over switch in sheet enclosure, suitable for operation on 415V, 3 phase A.C. Supply with single handle operated, 4 pole with two earthing terminals. (a)125 Amps.
Supply and laying / fixing of 3C x 2.5 sq.mm PVC insulated PVC sheathed / XLPE flexible multistranded unarmoured copper conductor cable of 1.1 KV grade (ISI mark) directly on surface of wall / cable tray including supplying and fixing clamps, screws, tye band , credit of faulty item etc. as reqd.
Replacement of the following ISI marked items i/c credit for non return of faulty item as reqd. (a) 4 feet long 36 Watts flourescent tube rod.
(b) 4 feet long 20 W / 18 W LED Tube Rods.
(c) 230 V starter suitable for flourescent tube rod fitting.
(d) Electronic choke suitable for operation on 1 phase 230 volts.
(e)Side holder suitable for flourscent tuberod fitting.
(f) 5/6 Amps capacity piano type switch.
(g)15/16 Amps capacity piano type switch.
(h)5/6 Amps capacity modular type switch.
(i)15/16 Amps capacity modular type switch.
(j)5/6 Amps capacity 3 pin socket outlet.
(k)15/16 Amps capacity 3 pin socket outlet.
(l)5/6 Amps capacity modular type 3 pin socket outlet.
(m)15/16 Amps capacity modular type 6 pin socket outlet.
(n)Supplying and drawing 1X1.5 Sq mm FRLS PVC insulated copper conductor, single core cable in the existingsurface / recessed steel / PVC conduit as required.
(o)Supplying and drawing 2X1.5 Sq mm FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.
(p)Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Sub Head-III (F/D ,F/A & Fire Fighting System )
Replacement / Supply of following type detector complete with base cover / MS Box/ MS Round box of having 4"X4" / junction bx/ stand / tripod etc and ITC of the same as directed by Engineer in Charge comp. As reqd. (a) Photo electric type Smoke detector
Ionisation type Smoke Detector
Replacing of the following spares/ component in control panel of Existing Auto F/D system with same make & model including , making connections, testing and comissioning etc.comp. as reqd. (a) Control Card
Zone Card
SMPS Charging Unit
Replacement of / supply of faulty response indicator suitable for existing Auto.F/D system by new one etc.comp. as reqd. ( LED & Card only )
Replacement of / supply of Electronic hooter of 4Watts suitable for existing Auto.F/D system by new one etc.comp. as reqd, ( Only Card only )
Replacement of / supply of Electronic hooter (speaker ) of suitalbe capacity for existing Auto.F/D system by new one etc.comp. as reqd, ( Only Card only )
Replacement of / Supply of Manually Call point with LED indicator (Pill box) in MS box etc.comp. as reqd.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a)20 mm
Refilling of existing 4.5 kgs. CO2 type fire extinguishers including transportation to authorised service centre including testing, pvdg. data sheet sticker & factory certificate etc as required
Replacement of defective 1.0 mtr long hose pipe( steel wire braided pipe ) with brand new pressure tested horn pipe a/w suitable for existing 4.5/3.6 kg CO2 type fire extinguishers etc as required.
Replacement / supply of following rating sealed maintenance free battery in duly charged condition i/c fixing making connection testing etc.as required ( Approved make of BSNL) (a)12 Volts, 20 AH
Conducting of Fire drill of the FD & FA system of T E Building as per the department norms i/c minor repairs work if any, cleaning of detectors with blowers etc. complete as required (a) For Ground floor only
(b) For Ground floor + 1 only
(c) Fire drill for G.F. + 2 Floor or more
Conducting of Fire drill of the Fire fighting wet riser system / down comer system at TE Bldg. Alkapuri Vadodara as per the departmental norms including i/c minor repairs / services of all the associated equipemnts upto satisfactory functioning of the fire fighting system etc. complete as required
Obtaining & liasioning of fire finghting clearance certificate from the local fire authorites as per local fire by laws for the buildings having wet riser system/down comers i/c claring of minor deffects available at time of testing, payment of all fees / charges to fire authorites etc as required. (TE Building Alkapuri)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .