Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.9 LAccepted-AOC PLOT NO 44 SIDDARTH PARK BEHIND ICE FACTORY KODKI ROAD BHUJ PIN 370 001 | BHUJ | KACHCHH | GUJARAT | 370001 | L1 | Accepted-AOC LOWEST BID | |
| 2 | L2₹46.6 L+₹1.3 L (2.84%)Rejected-AOC | L2 | Rejected-AOC HIGHER BID/ REJECT OF BID |
| Sl No | Description | Qty | Unit | M/S S. SINGH TRADERS L1 | machine vision plus L2 |
|---|---|---|---|---|---|
| 1.00 | Demolition of existing PCC as in form of roof padding incl backing over roof, any thickness including plastering and leaping (where full thickness removed or only a part there of disposal off rubbish upto a distance n.exc 100m, where directed complete all as specified and as directed. | 15 | Cum | 500 ₹7,500 Lowest | 600 ₹9,000 |
| 2.00 | M&L for cement concerete type C2 1:3:6 (20 mm graded aggrigate) as in filling and mass concerete etc complete all as specified and dirceted | 15 | Cum | 3,000 ₹45,000 Lowest | 4,000 ₹60,000 |
| 3.00 | M&L for 10mm thick rendering on fair faces of brick/concrete surfaces in CM 1:4 finished even and smooth without using extra cement mixed with water proofing compound.
(Note: WPC shall be measured & paid separately) | 300 | Sqm | 300 ₹90,000 | 250 ₹75,000 Lowest |
| 4.00 | Material and labour for roof surface treated with PU Elastoseal primer with Epoxy Primer to seal the pores and enhance the adhesion of the coating, supplying and applying single component waterproofing liquid membrane based on pure, elastomeric, polyurethane resin cold applied of spray/brush applied membrane with an elongation of 650%+ 50 and tensile strength not less than 2 Mpa, crack bridging ability not less than 2mm. No leakage upto 5 bars of water pressure. Shore Hardness > 50 Shore. The minimum thickness to be applied shall be 1.5 mm, (overall) in two layers (each layer 750 micron) or as per manufacturer’s instructions so as to achieve thickness not less than 1.5mm including providing & laying of protective Geotextile fabric 150 GSM over the entire membrane with proper overlaps of 75mm before laying SRI roof tiles complete all as specified and as directed.
Note: (i) The treatment shall be carried out by authorised applicator approved by GE as per the manufacturer
Make for PU Primer/ Membrane SIKA/ BASF, BERGER/ STP FOSROC/ SAINT GOBAIN, PIDILITE. | 300 | Sqm | 950 ₹2,85,000 Lowest | 950 ₹2,85,000 Lowest |
| 5.00 | M&L making benching / Roof Kerbing with PCC (1:2:4) type B0 using WPC as per manufacturer's instruction along side wall adjoining to roof in concave shape complete all as specified and directed.
Note : WPC shall be measured and paid separately | 10 | Cum | 5,000 ₹50,000 Lowest | 5,000 ₹50,000 Lowest |
| 6.00 | M&L Cutting chase in brick walls, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealing APP membrane etc and making good, cutting not exc 10cm girth complete all as specified and as directed | 55 | RM | 100 ₹5,500 Lowest | 100 ₹5,500 Lowest |
| 7.00 | Supply only Integral WPC complete all as specified and directed. (Make:Pedilite/Roft/Fosroc/Bauchemic India/Cico) | 72.36 | Kg | 100 ₹7,236 | 90 ₹6,512.4 Lowest |
| 8.00 | Demolition of cement concrete in ground floor and paving n exc 15cm thickness (below or above ground level) complete all as directed. | 4.5 | Cum | 500 ₹2,250 Lowest | 600 ₹2,700 |
| 9.00 | M&L Cement concrete ( 1:3:6) type C- 2, using (40mm graded stone aggregate) 75 mm thick as in sub base /plinth protection etc. Finishing cement concrete surface even and smooth without using extra cement complete all as directed | 81 | Sqm | 300 ₹24,300 Lowest | 300 ₹24,300 Lowest |
| 10.00 | M&L for Shootcreting Average thickness 25-30 mm in RCC columns, beams and slabs etc in layers with approved design mix (minimum cement content of 350 kg/cum on M-25) concrete having the specified minimum characteristics compressive strength (with ordinary Portland cement, coarse and graded stone aggregate of 6 mm maximum size in proportion as per design criteria) or Ready to use Micro concrete mortar including the cost of centering and shuttering at edges and corners etc as directed by Engineer in charge including chipping of unsound/weak concrete material 25mm average thickness from slabs /columns etc with manual chisel or standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc including removal of rust by applying approved rust remover hemical & the coating with Dr fixit Epoxy zinc Primer@6sqm/ltr at DFT of 100 microns as per specification ,applying the SBR Latex based bonding agent on each layer of the shootcreating work of Dr Fixit Pidicrete URP on the entire surface all as directed. | 50 | Sqm | 2,200 ₹1,10,000 Lowest | 2,400 ₹1,20,000 |
Tender Value
₹41.7 L
EMD Value
₹83,440
Closing Date
15 Dec 2025, 6:00 pmClosed
GE BHUJ
BHUJ
SPL REPAIR TO BLDG P-95 (ACUTE WARD), SPL REPAIR OF LIGHTENING CONDUCTOR SYSTEM AT MH BHUJ AND CONSTRUCTION OF VEHICLE SHED AT 75(I) INF BDE UNDER GE ARMY BHUJ
2025_MES_738437_2
8368
Open Tender
Civil Works
Item Rate
180 days
BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE ARMY
₹83,440
Yes
25 Feb 2026
24 Nov 2025
17 Dec 2025
24 Nov 2025
15 Dec 2025
8 Dec 2025
Amount
Demolition of existing PCC as in form of roof padding incl backing over roof, any thickness including plastering and leaping (where full thickness removed or only a part there of disposal off rubbish upto a distance n.exc 100m, where directed complete all as specified and as directed.
M&L for cement concerete type C2 1:3:6 (20 mm graded aggrigate) as in filling and mass concerete etc complete all as specified and dirceted
M&L for 10mm thick rendering on fair faces of brick/concrete surfaces in CM 1:4 finished even and smooth without using extra cement mixed with water proofing compound. (Note: WPC shall be measured & paid separately)
Material and labour for roof surface treated with PU Elastoseal primer with Epoxy Primer to seal the pores and enhance the adhesion of the coating, supplying and applying single component waterproofing liquid membrane based on pure, elastomeric, polyurethane resin cold applied of spray/brush applied membrane with an elongation of 650%+ 50 and tensile strength not less than 2 Mpa, crack bridging ability not less than 2mm. No leakage upto 5 bars of water pressure. Shore Hardness > 50 Shore. The minimum thickness to be applied shall be 1.5 mm, (overall) in two layers (each layer 750 micron) or as per manufacturer’s instructions so as to achieve thickness not less than 1.5mm including providing & laying of protective Geotextile fabric 150 GSM over the entire membrane with proper overlaps of 75mm before laying SRI roof tiles complete all as specified and as directed. Note: (i) The treatment shall be carried out by authorised applicator approved by GE as per the manufacturer Make for PU Primer/ Membrane SIKA/ BASF, BERGER/ STP FOSROC/ SAINT GOBAIN, PIDILITE.
M&L making benching / Roof Kerbing with PCC (1:2:4) type B0 using WPC as per manufacturer's instruction along side wall adjoining to roof in concave shape complete all as specified and directed. Note : WPC shall be measured and paid separately
M&L Cutting chase in brick walls, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealing APP membrane etc and making good, cutting not exc 10cm girth complete all as specified and as directed
Supply only Integral WPC complete all as specified and directed. (Make:Pedilite/Roft/Fosroc/Bauchemic India/Cico)
Demolition of cement concrete in ground floor and paving n exc 15cm thickness (below or above ground level) complete all as directed.
M&L Cement concrete ( 1:3:6) type C- 2, using (40mm graded stone aggregate) 75 mm thick as in sub base /plinth protection etc. Finishing cement concrete surface even and smooth without using extra cement complete all as directed
M&L for Shootcreting Average thickness 25-30 mm in RCC columns, beams and slabs etc in layers with approved design mix (minimum cement content of 350 kg/cum on M-25) concrete having the specified minimum characteristics compressive strength (with ordinary Portland cement, coarse and graded stone aggregate of 6 mm maximum size in proportion as per design criteria) or Ready to use Micro concrete mortar including the cost of centering and shuttering at edges and corners etc as directed by Engineer in charge including chipping of unsound/weak concrete material 25mm average thickness from slabs /columns etc with manual chisel or standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc including removal of rust by applying approved rust remover hemical & the coating with Dr fixit Epoxy zinc Primer@6sqm/ltr at DFT of 100 microns as per specification ,applying the SBR Latex based bonding agent on each layer of the shootcreating work of Dr Fixit Pidicrete URP on the entire surface all as directed.
Providing & fixing hard drawn MS steel wiremesh 80mm x 25mm with 3mm dia wire with Heavy duty nails, Fixing the mesh on the ceiling before shotcreting work complete all as directed.
Taking down cement plaster of any description and in any position of brick or stone wall/concrete surfaces on walls ,ceiling etc including raking out joints ,hacking for key scrubbing down with water etc & prepared to receive new plaster complete all as specified and directed
M&L Rendering 15 mm thick of CM 1:4 on fair faces of brick or concrete surfaces is to be finished even and smooth without using extra cement with mixing of water proofing compound complete all as directed.
M&L Rendering 10 mm thick of CM 1:6 on fair faces of brick or concrete surfaces is to be finished even and smooth without using extra cement with mixing of water proofing compound complete all as directed.
M&L for rendering 5 mm thick in Cement Mortar (1:3) on ceiling finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying acrylic wall care putty on old/ new plastered internal/External surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed. Make of wall Putty : JK wall Putty / Birla Wall care Putty / Bison Wall Putty. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE.
M&L preparation of surfaces and applying 02 coats of interior emulsion paint (light shade) on old/ new plastered@ 10 sq.m/litre/2 coats by using roller/brush to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer on existing yellow coloured surface complete all as specified and directed. Make of Interior Wall Primer : Asian / Berger / Nerolac [Best Quality]. Make of Interior Emulsion : Asian (tractor shyne) / Berger (bison) / Nerolac (BEAUTY sheen)
M&L complete removal of existing treatment and preparation of surfaces and applying 02 coats of exterior emulsion paint (light shade) on old/ new plastered with highlighter of any approved shade, @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed. Make of Exterior Wall Primer : Asian / Berger / Nerolac [Best Quality]. Make of Exterior Emulsion : Asian (APEX) / Berger (WEATHER COAT ANTI DUST) / Nerolac (EXCEL TOTAL)
M&L for Preparation of old painted surface of wood and wood based material any description and in any position over 10 cm width or girth and M&L for applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for Preparation of old painted surface of steel and iron surface of any description and in any position over 10 cm width or girth and M&L for applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of the newly plastered surfaces of walls,ceiling & applying two coats distemper oil- emulsion , white or tinted over a coat of primer surfaces of wall complete all as specified and directed
Providing & applying Rising damp-proof coating system with Single component ready to use damp-proof coating Roff Hydamp : 1. SURFACE PREPARATION: Thoroughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, bird droppings, etc. All large voids or hollow portions must be removed and re-plastered. Non- moving cracks having width upto 5 mm must be filled with Polymer based crack filler. 2. APPLICATION: Apply the first coat of Dr Fixit Dampguard Classic with a paintbrush directly on the prepared surfaces by mixing ( 1 part base:1 part hardner: 1 part of water) . Allow to dry for a minimum 2-3 hrs. Apply one part of DAMPGUARD mixed chemical and 2 parts of OPC white cement/Birla Putty and make the Putty, apply Putty on the entire surface area. Allow it to dry for at least 3-4 hours. Apply the Final coat of Dr Fixit Dampguard Classic on the entire surface and allow the surface to air cure 48 Hrs proceeds to paint.complete all as specified and directed
Taking down chowkats or frame with shutters (without taking off shutters from the frame) n exc 1.5 sqm each complete all as specified and directed
Taking down chowkats or frame with shutters (without taking off shutters from the frame) exc 1.5 sqm and n exc 4.0 Sqm each complete all as specified and directed
S & F anodised Aluminium alloy sections sliding windows with frames Series-C (20mm) and , 3 track sliding shutters duly fitted with neoprene beading, glazing clips, shutters with tinted glass 5mm thick and stainless steel wire cloth 0.35mm dia and average width of aperture 1.4mm , aluminium alloy handles etc. complete all as specified and directed
M&L for moulded grill medium grade of mesh size 75mmx75mm with 6mm square anodised aluminium bars fixed with suitable aluminum frame of size 37x19x2mm complete all as specified and directed.
M & L for Powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors , windows , ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
M&L for Powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified Note : Panel filling i.e.. glass, fibre sheet, board, wire mesh etc. shall be measured and paid for separately
S&F 18/19 mm thick Plywood with one sided decorated mica and other side white complete all as specified and as directed.
S&F in repair Tee grid suspension system of size 600 mm x 600 mm type-1 made out of roll framed hot dipped galvanised steel zince coated of not less than 120 gm/Sqm, main runner 0.3 mm thick of section 24 mm x 33 mm crross runner 0.30 mm thick of section 24 mm x 25 mm, wall angle shall be 0.63 mm thick of section 24 mm x 24 mm grid shall be suspended by 4 mm dia adjustable quick fit hanger rod, system exposed portion shall be pre painted polyester coated in off whitee/white in colour complete with material, fixing, jointing etc., with Coloured textured designer ceiling board 4mm thick of size 595 x 595 mm fixing with screws/clips complete all as per manufacturers instructions and direction.
Supply and fixing Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: (i) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made (ii) Cost for M.S. hold fast/ lugs or SS dash fasteners shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.
Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in-Charge including supply and fixing following items: (a) Stainless Steel (304 Grade) Finished Butt Hinges 100mm - 4 nos. per leaf (b) Stainless Steel (304 Grade) Finished Square Tower Bolt 150 mm long - 2 nos per leaf (c) Stainless Steel (304 Grade) Finished Handles 150 mm - 2 nos. per leaf
S&F 2nd class hard wood factory made plain framed panelled door shutters 35mm thick with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both sides. The size of rail and stiles as per IS:1003 (Part I), Klin seasoned and chemically pressure treated.complete all as specified and directed.
S&F for butt hinges 100mm size medium weight stainless steel .complete all as specified and directed
M&L for 150mm long extructed aluminium handle fabricated type complete all as specified and directed
S&F Aluminium anodised barrel tower bolt of extruded section 200 mm size complete all as specified and directed
S&F stainless steel sliding door bolt with hasp and stapple (bolt type) and fixing clips of sheet cast or extruded section with fixing bolts and sliding bolt of extruded section 300mm length & dia not less than 12mm with & including 6 Nos of bolts complete all as specified and directed
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed.
M&L for glazed ceramic tiles, coloured tiles, 600X300 x 7mm thick on vertical faces i.e.. as in skirting/dado etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles fix over and including 10 mm thick backing coat in cement mortar (1:4) complete all as specified and directed.
M&L for vitrified ceramic tiles double charged 10mm thick (square/rectangular), polished, coloured (light shade as approved), size of each tile 1200mm x 600mm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:4 complete all as specified and directed. Make: Johnson (Marbonite)/Kajaria/Somany/ Orient Bell Granito/ Asian Granito/ Oracle Grenito (Marbito)
M&L for vitrified ceramic tiles double charged10mm thick (square/rectangular), polished, coloured (light shade as approved), size of each tile 1200mm x 600mm, as in as in vertical surface like dado/ skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:4 complete all as specified and directed. Make: Johnson (Marbonite)/Kajaria/Somany/ Orient Bell Granito/ Asian Granito/ Oracle Grenito (Marbito)
Material & labour for machine cut kota stone slab size as in flooring, stair case landing. treads of steps, 18-22mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 20mm thick screed bed or bedding in cement mortar 1:6 all as specified and directed
Material & labour for machine cut kota stone slab size as in skirting, dado, vertical surfaces etc, 20-25mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including backing coat 15mm thick cement mortar 1:3 complete all as specified
M&L Granite slab work 18-20mm thick in floors steps, cooking platforms and like including pointing in white cement with admixture of pigment to match with granite shade over & including screed bed 15mm thick in CM 1:6 including cutting recess opening for the sink portion and embedding complete all as specified and directed by Engineer-in-Charge. (Note : No deduction shall be made for opening of sink portion, shall deemed to be included in the quoted rate) complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and othersimilar situations complete all as specified and directed.
S&F for Rotational moulded polyethylene water storage tank(white) of 1000 liter capacity (cylindrical vertical with closed top incl float valve) hoisted and fixed in position all as specified and directed
S&F in repair vitreous china wash basin, white flat back , size 550mmx450mm with and including Waste fittings, brass, chromium plated for basins with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed with and including Supplying and fixing cast copper alloy chromium plated fancy type pillar tap 15mm bore, screwed down high pressure with or without lettered hot or cold with long shanks, screwed for iron pipecomplete all as specified and directed.
S&F in repair PVC valve-less, syphonic action type, flushing cistern, low level, 10 litre capacity (ISI marked) white with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed
S&F in repair vitreous china Wash down water closet (pedestal pattern), complete including Pedestal pan and trap and seat cover, including connection to drain ( or outgoing pipe) and flushing pipe, antisyphonage pipes etc (excluding flushing cistern and flush pipe) complete all as specified and directed
S&F in repair vitreous china urinal Flat Back Half Stall (HxWxP): 345X320X560 mm white with grating and union for discharge pipe (excluding flushing cistern, flush pipe and white pipe) and providing fixing of plugs bedding urinal against wall including taking down the old one complete all as specified and as directed. (Make : Prayag Cat No 4998 or equivalent of Cera / Parryware) complete all as specified and directed.
Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 16 mm dia, any grade, of any description or in any position including fittings complete all as specified and directed
Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 20 mm dia, any grade, of any description or in any position including fittings cocomplete all as specified and directed
Supplying and Laying 16 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
Supplying and Laying 20 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
Demolition and breaking up drain pipes (salt glazed ware, AC or Reinforced concrete) internal dia of pipe in 75mm set in cement mortar complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed ware, AC or Reinforced concrete) internal dia of pipe in 110mm set in cement mortar and taking out of trenches, if required complete all as specified and directed
S&F for 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
S&F for 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F 75mm dia PVC (SWR) bends any radius with access door.complete all as specified and directed
S&F 110mm dia PVC (SWR) bends any radius with access door complete all as specified and directed.
S & F in repairs 15mm dia 2-in-1 bib tap with angle valves, Chromium plated crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipes or for unions.(Note: MAKE -CONFIRMING TO JAQUAR CAT PART-No. STE -107067 OR EQUIVALENT) complete all as specified and directed.
S & F in repairs 15mm dia angle valves, Chromium plated crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipes or for unions.(Note: MAKE -CONFIRMING TO JAQUAR CAT PART-No. STE -107053 OR EQUIVALENT) complete all as specified and directed
S&F in repairs 15mm dia Bib taps cast copper alloy, with Chromiun plated crutch or butterfly handle screwed down,for iron pipe or brass ferule complete all as specified and directed. (Note: MAKE -CONFIRMING TO JAQUAR CAT PART-No. APR -101037 OR EQUIVALENT)
S&F in repair health faucet spray type jet with brass jet, chromium plated, and 1.0 m long PVC flexible pipe complete all as specified and directed .(Note: MAKE -CONFIRMING TO JAQUAR CAT PART-No. STE -107067 OR EQUIVALENT)
M &L mild steel bars conforming to Fe 290 Gde E-165 as in guard bars ,ladder or similar works including welding etccomplete all as specified and directed
Demolition of concrete block masonry built in cement mortar or cement lime mortar complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry (Type C1, 1:3:6, 20mm aggregate) with solid blocks, exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed
S&F 18 mm thick prelaminated PVC Cheluka ply prelaminated one side with decorative choice lamination and other side plain fixed with screws to PVC celuka ply works all as directed and as per manufacture instructions Make : Rajshree plasticwood complete all as specified and directed.
S&F brass Handle fabricated type polished of Size 100 mm complete all as specified and directed.
S&F brass Handle fabricated type polished of Size 75 mm complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise spefifically provided for.complete all as specified and directed.
S&F for butt hinges 100mm size medium weight stainless steel .complete all as specified and directed.
Suface excavation n.exc 30 cm deep & avg 15 cm deep & getting out in any type of soil complete all as specified and directed.
Removing excavated material at a level n.exc 1.5 m above the starting point 50 mtr deposting where directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm as in any type of soil complete.
M&L, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete all as specified and directed.
S&F roof trusses (framed), vertical pole , trussed, pirline, crane gantries rails and fastenings and heavy bracket framing (beam tea angle chanell or flat section ) including distance pieces, cleats etc confirming to Fe410-W (grade E-250) quality A completed all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel 0.50mm thick of an color having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
M/L for two coat of enamel paint (Ist quality) over a coat of red oxid primer on new steel surface including preparation of surface over 10 cm width or girth all as specified.
Supply and fix single point air termination aluminium rod, 12 mm dia, 300 mm long completed all as specified and directed.
Supply and laying 40 mm bore galvanized steel tubing, medium grade (For fixing air termination rod as pipe post with all fittings laid in trenches/ road /etc complete as all specified and directed.
M&L for PCC 1:3:6 type C-1 using 20 mm graded aggregated as in copings (150x150x200 mm) for holding GI pipe kneelers, apex stones, bed plates, kerbs etc. water trouhs and the like including weatheering, slightly rouded or chamfered angles and throating including necessary form work complete all as specified and as directed.
Supply and fix Earth continuity conductor or main earthing lead fixed to wall on insulator or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation etc. as required of size 32 mm x 6 mm galvanised iron srip all as specified and directed.
Supply and fix Earth continuity conductor or main earthing lead fixed to wall/roof on insulator or racess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 25 mm x 3 mmaluminium srip all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x600mm buried directly in ground vertically to a depth not less than 2.25 metre belows normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32x6 mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate 15 mm dia GI pipe medium grade for watering pipe with funnel & wire mesh complete all as specified & directed. Note:- Earth lead wire and its proctection pipe uoto and including 7.5 mtr only from the top of earth electrode are included under this item and additiional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item f Schedule 'A'
Supply and fix test point termination block of size 75 mm x 75 mm x25 mm made of gun metal or phospherous bronze drilled and screwed including 3 Nos, 8 mm dia 25 mm long hex head screw and box of size 90 x 90x 90 mm (made out of 1.6 mm thichplain brass sheet ) and screwed to wall for protection of test point complete all as specified and directed.
Taking down carefully existing unserviceable aluminum/copper point wiring (light, fan, socket or power) of any description & in any position complete including all fittings & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc including taking out and removing serviceable fittings/fixtures and making good the disturbed surface of walls, floors, ceiling etc. to match with the existing surfaces complete all as specified and directed
M&L for point wiring with using 1.5 Sqmm (nominal area) multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade with and including PVC conduit pipe of adequate size concealed type on wall / fixed to surface ceiling with PVC rawl plugs with sunken type pressed steel terminal box suitable for laminated board or Modular fititng board and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLS PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:- NOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision of white cover plate and frame all as specfied and directed
One light/buzzer point controlled by one; one way switch.
One fan/exhaust fan point controlled by one, one way switch
One 3 pin socket out let 5 amp (independent) point controlled by one; one way switch.
One 3 pin socket out let 5 amp point on the (same board) with other switches.
All as per item No. 91 here-in-before but with 2.5sq mm size FRLS pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board Note : For item No 91 and 92 specfied run of single core cable and specfied run of earth continuity conductor and the relevant conduit with accessories shall be measured as one length ,The small length ,extra length required for loops etc for conncetion in DB are deemeed to be included in quoted price, only cable covered in conduit shall be measured.
S&F ceiling rose surface bakelite 63.5 x 20 mm, three terminals, complete all as specified and directed
Supply and fix modular switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed
Supply and fix modular switch 16 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed
Supply and fix modular socket, 6 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed
Supply and fix modular socket, 6 /16 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed
Supply and fix modular fan regulator 120 W 2 module complete all as specified and directed by Accepting officer
S & F in repairs earth plug and socket, single pole, neutral sheet metal enclosures with a two pin, plug and socket 20Amp, 240 volts with and including one MCB, SP, 20A, 240 Volts as per all as specified and directed.
S & F in replacement elegantly industrial general purpose box type luminaire, 1x20 Watt, designed box type LED luminaries, CRCA sheet steel housing with white reflector cover fitted to the body with decorative end covers complete with spring loaded rotor type lamp holders, connected block with and including 01 No LED lamp 20 Watt and all accessories, pre-wired and connecting the same to ceiling rose with & including three core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light fitting to walls / roof surface over and including 2 Nos PVC square box complete all as specified and directed.
S & F in replacement 10 W mirror light having indirect up down light for mirror and as well light application with CCT 6000K, including LED Bulb/Module and Electrical connection with 3 core flexible wire of appropriate size from ceiling rose to the tubelight fitting, all as specified and directed.
S&F lamp holder PVC / Polycarbonate type with cord grip cap suitable for LED lamp fitting complete all as specified and directed
Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & F sheet metal enclosure powder painted for MCB DB SPN 08 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed .
Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & F sheet metal enclosure powder painted for MCB DB SPN 12 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed
S&F sheet metal enclosures for distribution board when MCB to be used VTPN ( Triplepole and neutral ) 4 way busbar type , 415Volts, sheet metal powder coated, IP 42 protection with 200 Amps rated bus bar, double door type, with MCCB 100A complete all as specified and directed.
S&F in Repair MCB TPN, 63 Amps,415 Volts, rupturing capacity 10 KA."C" Series complete all as specified and directed.
Supply and fixing in Repair MCB SPN, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
S&F in repair MCB single pole, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
Taking Down Old Unserviceable Submain wiring complete including all accessories and making good the disturbed surfaces all as specified and as directed.
M/L for Sub main wiring with 2 runs of PVC insulated unsheathed multi stranded single core copper conducter 6 Sqmm drawn through PVC conduit/casing capping including accessaries with 6 sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting up ,all as directed. Note: 2 runs of cable and one run earth wire and conduit/Casing & Caping will be measured as one length.
M/L for Sub main wiring with 2 runs of PVC FRLS insulated unsheathed multi stranded single core copper conducter 4 Sqmm drawn through PVC conclead conduit including accessaries with 4sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting up ,all as directed. Note: (a)2 runs of cable and one run earth wire and conduit will be measured as one length. (b) cutting chases in to the wall of any thickness , fixing suitable size conduit and drawing copper conductor and and make odd the disturbed surface to match with the existing surface after pluging the holes complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing electric water heater, storage type steel body with inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers All as specified and Directed.
Drilling Holes of 12mm dia up to 100 mm deep holes in structural members at the interval of 300 mm in staggered manner or along the crack line in Reinforced Concrete (RC) structural element including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Valve) nozzle compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix inside the hole by applying thixotropic epoxy adhesive to ensure complete sealing and allow curing the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, leveling and finishing the external surface, after completion of the work, etc. complete all as specified and as directed
Grouting, injecting two part, low viscosity, moisture insensitive injection liquid, based on high strength epoxy resin by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout having following properties:- (i) Mixed Density 1.1 kg/l (at +27°C); Viscosity ~ 250 mPas at +30°C and should comply according to ASTM C 881, Type II and IV, Grade-1, Class E+F (ii) Compressive strength >= 70 N/sqmm (7 days) according to ASTM C 579; Tensile Strength ~ 50 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); Tensile Modulus ~ 2000 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); (iii) Bond Strength ~ 10.8 N/sqmm (failure in concrete) after 14 days at +30°C cure; Flexural strength ~ 50 N/sqmm according to ISO 178. (iv) Seal the nozzle with thixotropic epoxy adhesive after the refusal of grout material from the nozzle. Note:- leakage through other nozzle or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost complete all as specified and as directed by Engineer-in-charge. Note :- Mode of measurement: per kg of material consumed Make: Sika - SikaDur 52 LP/ Fosroc- Conbextra EP 10/ Pidilite Dr Fixit Epoxy Injec
Material and labour for Chipping of slab/columns /beams /chajjas/parapet/roof projection/balcony/staircase and removing loose mortar with chisel hammer without much impact on concrete surface, clean the surface by sand blasting the surface using river sand with minimum of 6 kg pressure at the nozzle or air blow by electric pressure blower by mechanical compressor, cleaning the exposed reinforcement with wire brushes etc and disposal of debris for all lead and lifts, complete all as specified and directed.
Material and labour for Cleaning & applying rust remover in two coats over rusted reinforcement surface and providing anti corrosive coating with two component epoxy based zinc rich primer/Rust passivation Inhibitor coat at the rate of 6-8 sq. mtr/ltr not less than 50 microns dft with Sika friazinc R or equivalent to reinforcement surface as per manufacturer’s instructions including all scaffolding, machinery, tools tackles and clearing of debris complete all as specified and as directed.
S & F of new steel or rebar’s by drilling holes with 10 mm to 20mm dia and 100 to 200mm deep as per IS code of 10D formula and filling the holes after inserting of reinforcement dia 8 to 16mm for anchoring at ends/shear connector and filled the holes with one or two component styrene free vinyl ester resin anchor or two components, styrene & cement free epoxy acrylate fixing and anchoring compound (having the technical parameters mentioned in material specifications) using standard sealant applicator gun after drilling holes of required diameter at required locations, for holding / fixing / placing in position the steel mesh reinforcement at desired level/ stretching complete all as specified and as directed . (Note : Steel/reinforcement shall be paid and measured separately).
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
machine vision plus (BID ID -3503379)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.30 MB
8368PS.pdf
Tender Documents • 0.75 MB
8368LISTOFMAKE.pdf
Tender Documents • 0.24 MB
8368TENDER.pdf
Tender Documents • 0.82 MB
BOQ_830082.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .