OVERHAULING OF VALVES ON INS NISTHAR
2026_HSL_99721_2
SR COMPLEX/PRODUCTION/OUT SOURCE REQUISITION/2026/201
Open Tender
Miscellaneous Services
30 days
VISAKHAPATNAM
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
6 Jul 2026
6 Jul 2026
9 Jul 2026
6 Jul 2026
9 Jul 2026
6 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Two Fire main valves near ATU-16 and Armory .To be overhauled as per
annexure attached.size 200NB SDNR/GATE/BF | 2 | NOS | - | - |
| 2 | Fitment of name tallies for various valves and pumps.Necessary arrangements for fitment to be undertaken by vendor.Required adhesives/screws to be arranged by vendor.material :brass, names to be
engraved.size : approx - id 10mm x od 50mm, | 50 | NOS | - | - |
| 3 | Deck caps for various rod gearing valves to be installaed along with round name tallilies.material for talllies and deck caps : Gunmetal .Size approx : dia 2'' x thickness 50mm.Deck caps suitable to the existing sizes to be supplied
by vendor. | 50 | NOS | - | - |
| 4 | Four Sea water valves of AER Sea Canal defective view leaking.To be overhauled as per annexure attached.SIZE : NW600 type butterfly . | 8 | NOS | - | - |
| 5 | Multiple valves and flanges in LP Air System/ general purpose airline leaking.Sizes - Ranging from NW15 - NW65.To be overhauled as per annexure attached. | 25 | NOS | - | - |
| 6 | PME gear driven SW pump suction valve before strainer stuck in open position (size 200NB) and requires to be overhauled.To be overhauled as per annexure attached | 2 | NOS | - | - |
| 7 | PME Gear driven SW Pump discharge valve (size 200 NB) not holding To be overhauled as per annexure attached | 2 | NOS | - | - |
| 8 | Fresh water filling valve (150 mm flap valb) at Quarter deck (Stbd side) requires to be overhauled / renewed view stuck in close position and material deterioted. To be overhauled as per annexure attached | 2 | NOS | - | - |
| 9 | AC-1 SW Pump suction valve (200mm butterfly vv) installed before strainer requires to be overhauled view hard to operate and stuck in closed position.
To be overhauled as per annexure attached | 2 | NOS | - | - |
| 10 | Defect in spindle of grey water overboard discharge valve in AVCAT pump
room.To be overhauled as per annexure attached | 2 | NOS | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
Tender_documents_Annexure.pdf
Tender Documents • 0.27 MB
Tender_documents_Scope.pdf
Tender Documents • 0.30 MB
Tender_documents_TBID_201.pdf
Tender Documents • 0.56 MB
BOQ_109321.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid