AGE (I) Raiwala
AGE (I) Raiwala
REPAIR/ REPLACEMENT OF UNSV PARTS OF DG SET AND ALLIED WORKS UNDER AGE (I) RAIWALA
2024_MES_659100_2
8935/E8
Open Tender
Miscellaneous Services
Works
180 days
AGE (I) Raiwala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) Raiwala
₹18,000
Yes
17 Dec 2024
25 Jul 2024
19 Sept 2024
25 Jul 2024
17 Sept 2024
1 Aug 2024
25 Jul 2024 - 30 Jul 2024
Amount
Dismantling and opening of parts for servicing of water cooled /Air cooled DG set of following capacity coupled with alternator, Maintenance and servicing mechanically and electrically, including cleaning, oiling /greasing, removing & replacement of defective / unserviceable parts with new parts,ie diesel filter /oil filter /Air filter /fan belt /fuel pipe/ engine oil pipe /Engine Oil etc as required at site as per manufacturer's instructions and checking of valves & nozzles etc, reassembling the parts of DG set at position ensuring proper alignment connecting to existing system and making DG set perfectly operational and testing at site connected load to the entire satisfaction of the Engineer-in-Charge complete all as specified and directed. (including mentioned in Srl No. 1(a) & (b) here in below) Notes:-(i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, `O’ rings, screws/gaskets/ packing /studs etc.(ii) Engine oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly for checking serviceability including cleaning of oil sump by pouring kerosene oil all as directed by the Engineer-in-Charge (iii) Fresh engine oil for DG sets shall be supplied by the contractor as “ Topping up and supply only” and shall be measured and paid separately under appropriate item of Sch . Its cost of filling is deemed to be included under the rates quoted by the contractor. (a) 25 KVA TO 125KVA 3 Phase 50 HZ Make:Kirloskar/Kirloskar Green and existing make on site
(b) 250 KVA 3 Phase 50 HZ Make:Kirloskar Green
Supply only element diesel filter with gasket suitable for following capacity of DG set dismantled / fixed under Sch item No 1.00 here in above complete all as specified and directed. (a)25 KVA TO 125 KVA 3 Phase 50 HZ Make:Kirloskar
(b) 250 KVA 3 Phase 50 HZ Make:Kirloskar
Supply only element Oil filter with gasket suitable for following capacity of DG set dismantled/fixed under Sch tem No 1.00 here in above complete all as specified and directed. (a) 25 KVA TO 125 KVA 3 Phase 50 HZ Make:Kirloskar
(b) 250 KVA 3 Phase 50 HZ Make:Kirloskar
Supply only Air cleaner element primary and safety for following capacity of DG set dismantled/fixed under Sch item No 1.00 here in above complete all as specified and directed. (a) 25 KVA TO 125 KVA 3 Phase 50 HZ Make:Kirloskar
(b) 250 KVA 3 Phase 50 HZ Make:Kirloskar
Dismantling and taking out the radiator fitted in following capacity of DG sets and strip opening complete radiator assembly,for servicing mechanically and proper cleaning of tubes with using de-scaling solution, including repair of water tubes and top/ bottom tanks by soldering / gas welding of leakage of tubes/tanks.including replacement of gasket, nut bolts,etc ensuring perfectly leak proof after servicing of radiator, re-assembling and fixing the same in position and testing the system complete all as specified and directed . Notes :- (i) Repairs/servicing/re-assembling and testing of radiator shall be carried out through a authorised representative of manufacturer.(ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item ’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, gaskets/ packing etc.(iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre. (a) 25 KVA to 125 KVA 3 phase 50 HZ .Make- Kirloskar Green and existing make on site
(b) 250 KVA 3 phase 50 HZ. Make- Kirloskar Green
Supply only the following items/spare parts suitable for raditor of DG set for following capacity dismantled/fixed under sl item No 10.0 here in above complete all as specified and directed.Note :-(i) Fixing element of these items is included under the rates quoted by the contractor for Schedule item No 10.0 here in above.(ii) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item. (a) Radiator hose set with clamp complete for 25 KVA to 125 KVA 3 phase 50 Hz DG Set
(b) Radiator hose set with clamp complete for 250 KVA 3 phase 50 Hz DG Set
Supply and topping up concentrated coolent suitable for radiator of DG set any capacity drained out / filling under`item No 1.00 here in above complete all as specified and directed.
M & L for Repair and Replacement for fixing self starter of 12 /24 Volt for 250 KVA DG set of suitable make as per site requirement. Note-: The contractor should visit site before quoting the rate of self starter.
(i) All as per Item No 8 above but for DG Set of capacity 100 KVA
(ii) All as per Item No 8 above but for DG Set of capacity 125 KVA
(iii) All as per Item No 8 above but for DG Set of capacity 25- 40 KVA
Supply and topping up lubrication oil SAE-40 ( 15W-40 Ci4 grade) suitable for Engine of DG set any capacity drained out / filling under item No 1.00 here in above complete all as specified and directed.
Supply and fix in replacement of change over switch 200 Amp 415V four pole in sheet enclosure with side handle operation, off load change over complete all as specified and as directed.Make : Indoasian or equivalent of L&T, control and switch gear.
Supply and fix in replacement of change over switch 63 Amp 415V four pole in sheet enclosure with side handle operation, off load change over complete all as specified and as directed.Make : Indoasian or equivalent of L&T, control and switch gear.
Supply and fixing in replacement of indication lamp R,Y,B complete set,complete all as specefied and as directed..
Supply and fixing in replacemnent of 415 volt AC digital AMP meter complete all as specefied and as directed.make :- AE or equivelent.
Supply and fixing in replacement of 415 volt AC digital Volt meter complete all as specefied and as directed.make :- AE or equivelent.
Supply and fixing in replacement of Battery charger unit 12 volt 06 amp for AMF Panels, complete all as specefied and as directed.
Supply and fixing in replacement of Battery charger unit 24 volt for AMF Panels, complete all as specefied and as directed.
Supply and fixing in replacement of 415 volt under volt relay (3P-3W) for AMF Panels,complete all as specefied and as directed.
Supply and fixing in replacement of power contactors 240 volt 50 Hz complete all as specefied and as directed.model no-MCX 41 of L&T or , C&S.SIEMENS
Supply and fixing in replacement of auto cut relay (3P-3W) 415 volt Ac. For AMF Panel,complete all as specefied and as directed.
Supply and fixing in replacement of alternator volt relay (3P-3W) 415 volt Ac. For AMF Panel,complete all as specefied and as directed.
Supply and fixing in replacement of micro engine relay 12 volt DC(ER-3),complete all as specefied and as directed.
Supply and fixing in replacment of electronic timer 24 volt DC,complete all as specefied and as directed..
Opening,checking,adjusting and tightning of tappet cover complete by torque wrench by applying proper pressure of tappet cover gas kit of the 25 KVA DG Set to-125 KVA DG Set capacity
M&L for replacement of hours meter, Electronic type suitable for DG Set of any capacity,complete all as specefied and directed.
M&L replacement of battery lead set of two,suitable for 88-180AH capacity 1.5mtr long incuding GM Terminals one end, copper lugs other end complete all as specefied and as directed.
S&F oil sump gasket set suitable for 25 to 100kva DG Set complete all as specefied and as directed.
M & L for servicing of turbo charger including replacement of repaire kit and minor parts of any rating DG Set, complete all as specefied and as directed.
S & F in replacement of water safety switch of any capacity DG Set ,complete all as specefied and as directed.
M&L for reconditionig of battery 12 volt 80AH to 250 AH and improve specific gravity minimum 1280 (g/cm³) of each cell including using electrolyte with transportation of bty from site to civil workshop and back fixing on existing position, testing of serviceability complete all as specefied and as directed.
Supply and fix in replacement of oil safety switch of 25-100KVA DG set, complete all as specefied and as directed
M & L in replacement of Belt for fan fuel pump,water pump and oil pump complete set suitable for DG Set 25 to 250 KVA
Supply and fixing in replacement of controller for 40-100 kva DG set all as specefied and directed by Engr-in -charge. Make :-Kirloskar Note-: The contractor should visit the site before quoting the rate of controller.
Supply and fixing in replacement of controller KG934 for 25 KVA DG set all as specified and directed by Engr-in-charge. Note-: The contractor should visit the site before quoting the rate of controller.
M & L for repair and replacement , testing, fixing of Controller of 250 KVA DG Set Model KG545 and including connecting required wiring as per manufactures wiring diagram all as specified and directed by Engr-in -Chrage
M & L for repair and replacement , testing, fixing of Controller of 125 KVA DG Set and including connecting required wiring as per manufactures wiring diagram all as specified and directed by Engr-in -Chrage
M & L for repair and replacement , testing, fixing of Controller of 40 KVA DG Set and including connecting required wiring as per manufactures wiring diagram all as specified and directed by Engr-in -Chrage
Supply and fixing in replacement of Actuator 24 volt for 250 kva DG set all as specefied and directed by Engr-in -charge. Make :-Kirloskar
M & L for repair in repair replacement of Fuel filter header complete with required accessories for 250 KVA DG set all as specified and directed by Engr-in-Charge
M & L for repair in repair replacement of Fuel filter header complete with required accessories for125 KVA DG set all as specified and directed by Engr-in-Charge
M & L for repair in repair replacement of Fuel filter header complete with required accessories for 40-100 KVA DG set all as specified and directed by Engr-in-Charge
M & L for repair in replacement of broken Door hinges as per exsiting model of 25 KVA DG set to 250 KVA DG Set
M & L for repair in replacement of LLOP for DG Set 125 KVA to 250 KVA complete with required accessories for replacement all as specified and directed by Engr-in-Charge.
M & L for repair in replacement of LLOP for DG Set 40 KVA to 100 KVA complete with required accessories for replacement all as specified and directed by Engr-in-Charge.
M & L for replacement of Front Facia of DG set including push button system electronic board
M & L for repair and replacement of Water pump for DG Set 40 KVA to 250 KVA capacity
M & L for repair and replacement Voltage Monitoring relay of Under voltage and over voltage relay having single phase preventer for the 125 KVA DG Set, Model VMRD-MSP
M & L for repair and replacement of Relay board 12 V DC 2+3 for DG Set of capacity 125 KVA at Auditorium and required electrical connection and required copper wiring all as specified and directed by Engr-in- charge.
(i)All as per Item No 48 above but for 24 V DC for DG Set of 250 KVA
(ii)All as per Item No 48 above but for 12 V DC for DG Set of 100 KVA
(iii) All as per Item No 48 above but for 12 V DC for DG Set of 25-40 KVA
M & L for repair and replacement of Rotating rectifier assembly three nos plus and three nos minus suitable for 250 KVA DG Set installed at Lower pump house and required wiring all as specified and directed by Engr-in- Charge
(i) All as per Item No 51 above but for DG Set of capacity 125 KVA
(ii) All as per Item No 51 above but for DG Set of capacity 40 KVA to 100 KVA
M & L for repair and replacement of anti virbration pad for 100 KVA to 250 KVA DG Set
Supply and fix test installation of automatic voltage regulator suitable for 40-100 KVA DG Set.Make-Kirloskar
Supply and fix test installation of automatic voltage regulator suitable for 125-250 KVA DG Set.Make-Kirloskar
S & F (in repairs) of fuel shut down solenoid valve kit including takingout old valve assy and making all connection testing for smooth operation in any type DG Set complete all as specified and directed by Engr-in-Charge.
S & F (in repairs) Fuel hose pipe flexible with metalic tape from fuel tank to filter, filter to FIP including allied nut bolt washer and coupling for DG set 25 KVA to 250 KVA with and including taking out old hose and making all connection testing for smooth operation all as directd.
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6mm thick, burried directly in ground to a depth not less than 4.5 metres deep below ground level with top edge of earth plate not less than 3.75 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected , GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20mm dia bore GI pipe 'medium grade' as water pipe from earth chamber to upper edge of earth plate, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 8mm dia @ 150 c/c both ways with 6mm dia MS round bar as in lifting handles, and mild steel angle iron frame 40mmx40mmx5mm for pit cover ,excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate number 3 of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
M&L for writing MES no. alotted to each DG set of various capacities alongwith DO's and Don’ts before and after operation of DG set with suitable paint of complete all as specified and directed by Engr-in-charge.
S&F ( In repairs) RPM CABLE of any type/make of DG set complete all as specified and directed by Engr -in- Charge
M & L for taking down of existing fuel from fuel tank by any means, removing of sludge and sediments deposited inside the fuel tank by repeatedly washing by using of chemical & detergent with air compressor including rectifing of leakage if found and refixing the same in position as per direction of engineer in charge by testing all as specified and directed. cap 25-100 KVA DG Sets.
M & L for taking down of existing fuel from fuel tank by any means, removing of sludge and sediments deposited inside the fuel tank by repeatedly washing by using of chemical & detergent with air compressor including rectifing of leakage if found and refixing the same in position as per direction of engineer in charge by testing all as specified and directed. cap 125-250 KVA DG Sets.
M& L for repair and replacement of Governor card for 250 KVA DG set all as specified and directed by Engineer-in-charge. Note-: The contractor should visit site before quoting the rate for Governor card.
TRINITY CONSTRUCTION (BID ID -3076674)
DOON DIESEL SALES AND SERVICE (BID ID -3081941)
M/s badrinath Traders (BID ID -3097779)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .