Tender Value
₹35.0 L
EMD Value
₹70,020
Closing Date
11 Oct 2024, 6:00 pmClosed
GE ARMY BHUJ
BHUJ
CERTAIN BR AND EM REPAIRS REPAIRS TO PATH SHOULDERS AND OTHER MISC ITEMS AND REPAIR REPLACEMENT OF LT DISTRIBUTION LINE AC WATER COOLER OF SIYOT UNDER AGE BR II AND AGE EM OF GE ARMY BHUJ
2024_MES_670916_1
8237
Open Tender
Civil Works
Item Rate
270 days
GE ARMY BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE ARMY BHUJ
₹70,020
Yes
13 Nov 2024
3 Sept 2024
14 Oct 2024
3 Sept 2024
11 Oct 2024
16 Sept 2024
Amount
M&L for rendering 15mm thick in cement mortar (1:4) on concrete/ fair surfaces of block masonry, finished even and smooth without using extra cement with and including mixing water proofing compound as per manufacturers instructions complete all as specified and as directed. (NOTE:- Water proofing compound shall be measured and paid for separately under appropriate item of Sch "A' as supply only on requirement basis)
M&L for Preparation of new surfaces of wall including cornices plastered or unplastered surfaces by brooming down or steel wire brushing to remove dust, dirt and loose scales of cement paint and other foreign material, scrapping down, moss and efflorescent salts, washing, rubbing down and stopping of painted surface and M&L for applying comougflage pattern Two coats of cement base paint over a coat of primer incl watering and curring of surfaces adequately before and after application of cement base paint complete all as specified and directed.
M&L for Preparation of old decorated surfaces of comougflage pattern wall including cornices plastered or unplastered surfaces by brooming down or steel wire brushing to remove dust, dirt and loose scales of cement paint and other foreign material, scrapping down, moss and efflorescent salts, washing, rubbing down and stopping of painted surface and M&L for applying Two coats of cement base paint incl watering and curring of surfaces adequately before and after application of cement base paint compelete all as specified and directed.
Demolition of concrete block masonry built in cement mortar or cement lime mortar complete all as specified and as directed.
M&L for precast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6 complete 1:5:10 Type B-1 (using 20mm graded aggregate) and 12.50 mm in the ratio compelete all as specified and directed.
M&L for 10 mm thick rendering on surfaces other than fair faces of brick/concrete surfaces in CM (1:6) and finished even and smooth without using extra cement complete all as specified and directed.
M & L for applying putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed.
M&L for preparation of the newly plastered surfaces of walls & applying two coats distemper oil- emulsion , white or tinted over and including a coat of primer surfaces of wall complete all as specified and directed.
M & L for preparation of old decorated plastered or unplastered surfacesof wall including washing,rubbing down and stopping of distempered surface and applying one coat of distemper oil emulsion paint white or tinted complete all as specified and directed.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping exposed surfaces finished even and smooth using extra cement including necessary form work complete all as specified and directed.
Demolition of concrete (unreinforced) of any description and in any position not specifically provided for complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation of manholes, mass concrete etc complete all as specified and directed.
Supply only water proofing compound all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Non-skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed.
M&L for glazed ceramic tiles, coloured tiles, 450X300 x 7mm thick on vertical faces i.e.. as in skirting/dado etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles fix over and including 10 mm thick backing coat in cement mortar (1:4) complete all as specified and directed.
M & L for non skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.complete all as specified and directed.
S&F in repair PVC valve-less, syphonic action type, flushing cistern, low level, 10 litre capacity (ISI marked) white with inlet, ball valve, float and handle including brackets complete all as specified and directed.
Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 15mm dia, any grade, of any description or in any position including fittings complete all as specified and directed
Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 20mm dia, any grade, of any description or in any position including fittings complete all as specified and directed
Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 25mm dia, any grade, of any description or in any position including fittings complete all as specified and directed
M & L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting not exc 10 cm girth complete all as specified and directed.
Supplying and Laying 16mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
Supplying and Laying 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
Supplying and Laying 25mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
S&F in repair Bib tap standard of PTMT any colour high pressure screwed for iron pipe 15mm bore (Minimum weight 90 gms) complete all as specified and directed.
S&F in repair Stop valve of PTMT any colour high pressure screwed for iron pipe 15mm bore (Minimum weight 90gms) complete all as specified and directed.
S&F in repair stop valve of PTMT any colour high pressure screwed for iron pipe 20mm bore (Minimum weight 112gms) complete all as specified and directed.
S & F in repairs 15mm dia 2-in-1 bib tap with angle valves, Chromium plated crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipes or for unions complete all as specified and directed.(Note: MAKE - JAQUAR CAT PART-No. STE -107067)
S&F in repairs shower rose 100 mm dia of brass chromium plated fancy type with or without swivel joint suitable for fixing to 15mm bore GI pipe complete all as specified and directed.(Note: MAKE - JAQUAR CAT PART-No. EOS-542N)
S&F in repair health faucet spray type jet with brass jet, chromium plated, and 1.0 m long PVC flexible pipe complete all as specified and directed .(Note: MAKE -JAQUAR CAT PART-No. STE -107067)
S & F in repairs 15mm size PVC connections with PTMT nuts of length 450 mm complete all as specified and directed.
M&L in repairs 40mm dia Low density poly ethylene pipes(LDPE) of pressure rating 6 Kgf/cm2 fixed complete to wall, ceiling or in floors etc complete all as specified and directed.
S&F for Rotational moulded three layered polyethylene water storage tank(white) of 1000 liter capacity (cylindrical vertical with closed top incl float valve) hoisted and fixed in position complete all as specified and directed.
M&L for preparation of old comougflage pattern steel painted surfaces exc 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
S&F in repair of PVC cabinet size 650 x 400mm, comprising of looking glass, space for bath soap, shampoo, tooth brush and paste, handle towel rail complete all as specified and directed as approved of any of the following (Makes :- HINDWARE / CERA / NEYCER / PARRYWARE/CLASSIC)
Taking down chowkats or frame with shutters (without taking off shutters from the frame) n exc 1.5 sqm each complete all as specified and directed.
Taking down chowkats or frame with shutters (without taking off shutters from the frame) exc 1.5 sqm and n exc 4.0 Sqm each complete all as specified and directed.
Taking down shutters of any description and in any position exceeding 1 sqm & not exceeding 2 sqm each complete all as specified and directed.
S&F 2nd class hard wood factory made plain framed panelled door shutters 35mm thick (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both sides. The size of rail and stiles as per IS:1003 (Part I), Klin seasoned and chemically pressure treated complete all as specified and directed.
S&F solid PVC door frame of size 50mmX47mm made out of 5mm both side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet reinforced with M.S. Square tube, suppling & fixing in opening all as per specifications and drawing shown on sl page No 150 of SSR part II (for item-884).complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & both side prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; panelling of both side prelam PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading & jointed together with solvent cement, supply & fixing in the frame at site as per SSR specifications & diagram/product drawing shown on sl page NO 146 of SSR Part II with the size of door shutter complete all as specified and directed.
S & F Powder coated Aluminium alloy sections sliding windows with frames Series-C (20mm) and , 3 track sliding shutters duly fitted with neoprene beading, glazing clips, shutters with tinted glass 5mm thick and stainless steel wire cloth 0.36mm dia and average width of aperture 1.4mm , aluminium alloy handles etc complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples complete all as specified and directed.
S&F for butt hinges 100mm size medium weight stainless steel complete all as specified and directed.
M&L for 150mm long extructed aluminium handle fabricated type complete all as specified and directed.
S&F Aluminium anodised barrel tower bolt of extruded section 200 mm size complete all as specified and directed.
S&F stainless steel sliding door bolt with hasp and stapple (bolt type) and fixing clips of sheet cast or extruded section with fixing bolts and sliding bolt of extruded section 300mm length & dia not less than 12mm with & including 6 Nos of bolts complete all as specified and directed.
S & F butt Hinges, medium weight, stainless steel, 100 mm size complete all as specified and directed.
M & L for preparation of old painted surface of wood and wood based material any description and in any position over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F aluminium powder coated ventilator with fixed aluminium frame of size 65 x 40 x 1.98mm thick fixed in vertical position with aluminium vertical members and half portion to be provided with 4mm thick pin head glass and remaining portion to be louvered using 4mm thick pin head glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm incl necessary channel frame work, including rubber gasket and aluminium beading complete all as specified and directed.
M & L for Powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors , windows , ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
M&L for Powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc complete all as specified and directed. (Note :- Panel filling i.e.. glass, fibre sheet, board, wire mesh etc shall be measured and paid for separately.)
S&F in repairs 20mm dia powder coated decorative type curtain rod incl brackets complete all as specified and diretced.
Hacking out old broken glass (any thickness size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clip and providing and fixing new ones complete all as specified and directed.
S&F Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and including fixing at site on wooden frame/PVC frame as per specifications and drawing complete all as specified and directed.
S/F in repair 75 mm bore PVC (SWR) floor trap plain with grating incl jointing with solvent cement complete all as specified and directed.
S&F in repair PVC (SWR) gully trap 110 mm, setting and jointing with solvent cement complete all as specified and directed.
Dismantling 110 mm cast iron /PVC SWR drain pipes, jointed in cement mortar and taking out of trenches, if required (incuding fitting & fixtures) complete all as specified and directed.
Dismantling 75 mm cast iron /PVC SWR drain pipes, jointed in cement mortar and taking out of trenches, if required (incuding fitting & fixtures) complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) pipes Type B ISI marked single socketed in any length with rubber ring joints laid in trenches complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR) pipes Type B ISI marked single socketed in any length with rubber ring joints laid in trenches complete all as specified and directed.
S&F in repair PVC (SWR) bends, 110 mm bore, any radius complete all as specified and directed.
S&F in repair PVC (SWR) bends, 75 mm bore, any radius complete all as specified and directed.
Demolition of concrete block masonry built in cement mortar or cement lime mortar complete all as specified and as directed.
M&L for Pre-cast cement concrete block masonry 1:3:6 Type C1 (Using 20mm graded aggregate) with solid blocks, exc. 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth in soft/loose soil; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
M & L for plain cement concrete 1:4:8, Type D-2 (using 40mm graded aggregates) as in foundations, filling and mass concrete etc complete all as specified & as directed.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for providing precast cement concrete 1:2:4 type B1 (using 20 mm graded aggregate) in apex stone/kerb stone with plain fair faces including chamfers, weathering throating etc and set in CM 1:4 complete with joints, size and shape as approved complete all as specified and directed.
M&L for precast RCC 1:2:4 type B-1 ( using 20mm graded aggregate) as in cover slab or similar works set & jointed in CM 1:4 complete including necessary formwork complete all as specified and directed.
M&L for exterior grade, coloured, cement concrete designer chequered tiles of size 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floor etc. complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 20mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed.
M&L providing precast cement concrete rubber moulded coloured interlocking tiles with grey cement and pigment conforming to IS-15658-2006 of 80 mm thick (M-40 grade) of approved design and pattern complete all as specified and directed.
M&L for 60 mm thick paver blocks rubber moulded PCC M-35 with grey cement and pigment conforming to IS-15658-2006 of approved design and pattern complete all as specified and directed.
M&L for cutting of Bitumenous road edges to achieve straight/vertical edges to accommodate paver blocks/PCC subbase/sand Cushioning etc complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) for filling of gap between road, kerbs stone and interlocking paver block with finished fair complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in as in sub base complete all as specified and directed.
M&L for 100 mm thick PCC 1:2:4 type B2, (using 40 mm graded stone aggregate) as in floors/paving finish even and smooth without using extra cement complete all as specified and directed.
M&L for forming expansion joints,12 mm thick in concrete slab of thickness of 100 mm and filled with preformed bituminous filler and top 30 mm primed with sealing compound Grade A complete all as specified and directed.
M&L for forming contraction (Dummy) joints 65 mm deep x 10 mm wide filling with sealing compound grade A complete all as specified and directed.
M&L for aggregate for loose filling, of gauge 20 mm to 60 mm graded Spreading and levelling in layers n exc 10cm thick. complete all as specified and directed.
M&L for Sand filling under floors or in foundation icl watering and consolidation for laying interlocking tiles complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 (using 20mm graded crushed stone aggregate) as in coping, benching, holdfast, fixing of fencing post above wall etc,finished even and smooth using extra cement incl necessary form work complete all as specified and directed.
Excavating all filled and accumulated earth, rubbish, foreign material from the drain including removing excavated material n.exc 100m and depositing where directed at a level n.exc 1.5 above the starting point complete all as specified and as directed.
Taking down cement plaster on brick or stone wall including racking out joints, hacking for key scrubbing down with water etc complete all as specified & directed.
M&L for 15mm thick rendering on fair faces of brick/concrete surfaces in CM 1:4 finished even and smooth without using extra cement mixed with water proofing compound (Note :- WPC shall be measured & paid separately)
M&L for Preparation of new surfaces of wall including cornices plastered or unplastered surfaces by brooming down or steel wire brushing to remove dust, dirt and loose scales of cement paint and other foreign material, scrapping down, moss and efflorescent salts, washing, rubbing down and stopping of painted surface and M&L for applying comougflage pattern Two coats of cement base paint over a coat of primer incl watering and curring of surfaces adequately before and after application of cement base paint compelete all as specified and directed.
M&L for preparation of new concrete surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including a coat of primer complete all as specified and directed.
M&L for preparation of old painted concrete surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of New/old steel surfaces of any description over 10 cm width or girth and applying one coats of synthetic enameled paint complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
S&F mild steel rolled sections as in main and cross beams, hip and jack rafters; purlins post, where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 290 Gde E-165 complete all as specified and directed.
S&F mild steel rolled section as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc etc conforming to Fe 410 -W (GdeE- 250) quality A Fe complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and as directed
S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge / roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Taking down carefully existing unserviceable aluminum/copper point wiring (light, fan, socket or power) of any description & in any position complete including all fittings & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc including taking out and removing serviceable fittings/fixtures and making good the disturbed surface of walls, floors, ceiling etc. to match with the existing surfaces complete all as specified and directed.
M&L for point wiring for One light/fan/exhaust fan/buzzer point controlled by one,one way switch with using 1.5 Sqmm (nominal sectional area) multi stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade with and including PVC casing and caping of adequate size fixed to the surface and including PVC flush box suitable for holding modular frame and switchs of required size and modules including single core multi-stranded copper conductor 1.5 sqmm size PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit complete NOTE :- (i) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. iii) The quoted rates shall be deemed to be inclusive for provision of flush box suitable for modular fitting including base plate ,frame of suitable module specfied by Enginner-in-charge.
All as per above Item No. 101 but One light/buzzer point controlled by one; one way switch complete all as specified and directed.
All as per above Item No. 101 but One fan/exhaust fan point controlled by one, one way switch complete all as specified and directed.
All as per above Item No. 101 One 3 pin socket out let 5 amp (independent) point controlled by one; one way switch complete all as specified and directed.
All as per above Item No. 101 One 3 pin socket out let 5 amp point on the (same board) with other switches complete all as specified and directed.
All as per above item No. 101 here-in-before but with 2.5sq mm size FRLS pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board complete all as specified and directed.
S&F ceiling rose surface bakelite 63.5 x 20 mm, three terminals, complete all as specified and directed.
S&F Modular switch 1 way 6A,1 module, one way, 230 volts AC circuit complete all as specified and directed.
S&F socket outlet combination, multipurpose, three pin, 15 Amps & three pin 5 Amps controlled by one switch , modular type, 230 volts AC circuit complete all as specified and directed.
S&F Modular switch 1 way 16A,1 module, one way, 230 volts AC circuit complete all as specified and directed.
S&F modular fan regulator electronic, step type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified and directed.
Supply LED 20 W high quality indoor batten type warm light tube light fitting with PC housing and as well light application CCT 6000 K, electrical connection of three core 0.5 sqmm copper flexible connection from ceiling rose to tube light fitting and with proper square box for fitting of tube light fitting complete all as specified and directed.
Supply LED 20 W high quality indoor batten type warm light tube light fitting with PC housing and as well light application CCT 3000 K, electrical connection of three core 0.5 sqmm copper flexible connection from ceiling rose to tube light fitting and with proper square box for fitting of tube light fitting complete all as specified and directed.
S & F in replacement 10 W mirror light having indirect up down light for mirror and as well light application with CCT 6000K, including LED Bulb/Module and Electrical connection with 3 core flexible wire of appropriate size from ceiling rose to the tubelight fitting complete all as specified and directed.
S&F lamp holder PVC / Polycarbonate type with cord grip cap suitable for LED/CFL lamp fitting complete all as specified and directed.
Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & F sheet metal enclosure powder painted for MCB DB SPN 08 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed.
Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & F sheet metal enclosure powder painted for vertical type MCB DB TPN 04 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed.
Supply and fixing MCB TPN, 63 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
Supply and fixing MCB SPN, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
S&F MCB single pole, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
Taking Down Old Unserviceable Submain wiring complete including all accessories and making good the disturbed surfaces all as specified and as directed.
M & L for Sub main wiring with 2 runs of PVC insulated unsheathed multi stranded single core copper conducter 6 Sqmm drawn through PVC casing caping including accessaries with 6 sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting up ,all as directed. (Note:-2 runs of cable and one run earth wire and casing caping will be measured as one length.)
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. (NOTE:- Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’)
Supply and fix in repiar socket outlet five pin, 5 Amps, flush type, 230 volts AC circuit complete all as specified and directed.
Supply and fix switch socket outlet combination, multipurpose, three pin, 15 Amps & three pin 5 Amps controlled by one switch , flush type, 230 volts AC circuit complete all as specified and directed.
Supply and fix in repair switch flush type, 5/6 Amps, single pole, one way, 230 volts AC circuit complete all as specified and directed.
Supply and fix LED Bulb 12 Watt 5 star rating complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in hard dense soil complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in hard dense soil.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils.
M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed. Note: Punned thickness shall only be measured and paid
Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables.
S & F GI pipe, light grade, of size 50 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection .
M&L for Disconnecting, taking out, removing old existing unserviceable LT underground cable of any size all as specfied and directed
Supplying ,Laying , jointing and testing XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade of laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed.
All as per above Item No.132 here in before but of size 3.5 core 50 Sqmm complete all as specified and directed.
All as per above Item No.132 here in before but of size 4C core 16 Sqmm complete all as specified and directed.
Material and labour for bring the van mounted full automated underground cable fault locator machine at site for find out HT/LT cable fault in underground completely all as specified and directed by Engineer in Charge. (Note: (a) Fault machine,cable & T&P required shall be arranged by the contractor.)
Supply and fix in repair MCCB Thermal Magnetic release,Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 63 Amps 16 KA complete all as specified and directed.
Supply and fix in repiar MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 100 Amps 16 KA complete all as specified and directed.
M&L for earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth strip 32X6 mm by means of bolts, nuts, washerws and check nuts all shown in electrical plate No.5 of SSR Part- I connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point all as specified and testing on completion all as per directed.
Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.
(ii) Earthing strip and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule.
NOTE FOR TESTING :- (i) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge.
M&L for refreshing of incomming and all outgoing XLPE cable of any size including excavation for removing cable loop , refreshing of exsiting all cable by removing insulation ,cleaning of panel inside and ouside ,including removing old damaged lugs and fixing of suitable size lugs, PVC conncetor,dressing of all cables . nuts ,bolts,washer to all incomming and outgoing MCCB , insulating all bare conductor with insulating cable of suitable colour complete all as specified and as directed.
Maintaning of HT/LT over head lines by trimming the of tree branches touching to the HT/LT over head conductors lines upto 03 mtr away from the live conductors surrounding area complete all as directed at site complete. (Note :- cost of labours deemed to be including cutting the tree branches and depositing the tree branches 50 Mtr away from the poles or as directed at sie complete.)
Supply and erecting Prestressed concrete pole, 9.0 metreslong, 102mm x 172mm at top and l02mm x 279mm at bottom, class 10 all complete all as specfied and directed. (Note; Erection of pole should be done on hill, where manual transport and erection is only possible.)
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m in depth and not exceeding 3.0m depth for foundation, laying of cable/pipe etc or for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified & directe
M&L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) in foundation, filling and mass concrete for poles/struts etc including necessary formwork as required complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded aggregates) as in copings, kneelers, apex stones, bed plates, kerbs etc., water troughs and the like including weathering, slightly rounded for chamfered angles and throating including necessary form work complete all as specified and as directed.
Taking down carefully ceilling fans of any size, type by disconnecting the wires and dismanting blades and removing fan and blades to contractor,s workshop or site for repair/ overhauling/re winding/painting etc including re fixing after neccesary repair complete all as specified and directed.
All as per above Item No 102 here in before but for exhaust/cabin fans of any size/make complete all as specifed and as directed.
M&L for servicing/oiling and greasing of fan of any size/type by using appropriate grade of oil/grease and replacing defective parts such as bush, bearing split pin rubber bush hanging clamp capacitor including cleaning for fixing the same complete all as specified and directed. (Note|-Parts/components will be measured and paid seperately under their respective items)
M&L for rewinding of celling fan 1200mm /1400mm sweep, AC, 230 volts single phase with super enamelled copper winding wire of appropriate size including packing, insulating material soldering varnishing assembling and testing as required complete all as specified and directed.
Rewinding of exhaust fan 300mm to 450mm sweep AC 230 volts single phase with super enameled copper wire of appropriate size including packing insulating material, soldering, varnishing , assembling and testing complete all as specified and directed.
S&F bearing of celling fans for celling fans of 1200/1400mm sweep suitable for different makes /type of fans complete all as specified and directed.
S&F bushes gun metal suitable for celling fans 1200/1400mm sweep/exhaust fan 300 to 450mm sweep/cabin fan of any size complete all as specified and directed.
S&F ball bearing suitable for exhaust fan 300 to 450mm sweep of different make complete all as specified and directed.
S&F rubber reel type synthetic rubberwith 14.5mm hole suitable for hooks of celling fans complete all as specified and directed.
S&F condenser/capacitor suitable for 230 volts singls phase celling fan 1200mm/1400 sweep of approved make and quality of capacity 2.5 MFD complete all as specified and directed.
Description all as per item No 156 here - in - before but capacity 4 MFD for exhaust fan of approved make complete all as specified and directed.
Dismantling of geyser from its location 03/06/25/50Ltrs cap and making leak proof by means of welding of tanks replacement of parts, under item No 2 and one coat of primer for inner tank re-assembling, including packing of glass wool properly replacement of worn out nut bolts washers screws as reqd and re fixing after neccesary repair of complete set to work after one coat of synthetic enamelled paint complete all as specified and directed.
Supply and fixing of following items for geyser complete.(a) Apparatus plate heavy duty rubber gasket suitable for 03/06/25/50 Ltr of any size complete all as specified and directed.
(b) Geyser element 1.5 KW complete all as specified and directed. (Make :- Theata/Venus)
(c) Geyser element 2.0 KW complete all as specified and directed. (Make :- Theata/Venus)
(d) Thermostate switch ISI Marked complete all as specified and directed.
(e) Plug top 3pin 15 Amps ISI Marked complete all as specified and directed.
Dismounting, window AC 1.5/2.0 TR to the ground level, transporting to near water point in the complex, taking out the AC from outer cover, washing the unit with soap solution jet followed by clean water jet, drying, wiping, transporting back & re-fixing at original position complete all as specified and directed.
Servicing of split type AC of capacity 1.5/2.0 TR capacity of any make by washing the outdoor unit condenser coil with soap water jet followed with clean water jet and indoor unit with the help of blower, wipe and clean the unit with dry cloth complete all as specified and directed. (Note:- Cost of hiring T&P i.e. blower, pressure pump bucket hose pipe deemed to be included.)
M&L for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for :-
(a) Water coolers 40 to 150 ltrs cooling capacity complete all as specified and directed.
(b) Refrigerator of 165 to 310 ltrs capacity complete all as specified and directed.
Taking down defective /unserviceable AC rotary compressor of any make of capacity 1.5 TR and replacing with new rotary compressor of make Tecumseh, Toshiba, Mitsubishi, Hagelin refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed.
Taking down defective /unserviceable AC rotary compressor of any make of capacity 2.0 TR and replacing with new rotary compressor of make Tecumseh, Toshiba, Mitsubishi, Hagelin refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed.
Taking down defective /unserviceable AC reciprocating compressor of make Tecumseh /kirloskar /emerson of capacity 1.5 TR , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed.
Taking down defective /unserviceable AC reciprocating compressor of make Tecumseh /kirloskar /emerson of capacity 2.0 TR , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed.
M&L for checking for leakages, creating vacuum, charging of R-410 gas in the unit to the required pressure complete all as specified and directed by Engr-in-Charge for the following appliances:-
(a) Split type AC 1.5/2 Ton capacity complete all as specified and directed.
(b) Window type AC 1.5/2.0 Ton capacity complete all as specified and directed.
(c) Water coolers 40 to 150 ltrs capacity complete all as specified and directed.
(d) Refrigerator of 165 to 310 ltrs capacity complete all as specified and directed.
Supply and replace capacitors of the following capactities for ACs water coolers, refrigerators, etc complete all as specified and directed.
M&L for shifting of split type AC from one location to other location including fixing evaporator unit with gitties/fastner, cutting wall/concrete incl arrangement of T&P for laying copper tubing, positioning condensing unit, laying copper tubing incl brazing work, connecting drain pipe, making good disturbed surface complete all as specified and as directed by engineer-in-Charge. (Note- Any additional copper tubing required for the work is included in the item)
S&F in replacement of wire remote control ( micro- processor) unit suitable make of split type AC 1.5/ 2 TR complete all as specified and directed.
Supply and replace thermostats of of following :-
(a) Window type AC 1.5/2.0 Ton capacity complete all as specified and directed.
(b) Split type AC 1.5/2 Ton capacity complete all as specified and directed.
(c ) Water coolers 40 to 150 ltrs capacity complete all as specified and directed.
(d) Refrigerator of 165 to 310 ltrs capacity complete all as specified and directed.
Supply and replace condenser unit of the following appliances including making of all connectiions as specified and directed by Engr-in-charge following :-
(a) Window type AC 1.5/2.0 Ton capacity complete all as specified and directed.
(b) Split type AC 1.5/2 Ton capacity complete all as specified and directed.
(c) Water coolers 40 to 150 ltrs capacity complete all as specified and directed.
(d) Refrigerator of 165 to 310 ltrs capacity complete all as specified and directed.
Supply and replace cooling coil of following :-
(a) Window type AC 1.5/2.0 Ton capacity complete all as specified and directed.
(b) Split type AC 1.5/2 Ton capacity complete all as specified and directed.
(c) Water coolers 40 to 150 ltrs capacity complete all as specified and directed.
(d) Refrigerator of 165 to 310 ltrs capacity complete all as specified and directed.
Supply and replace condenser fan motor complete with necessary mounting bracke to and base frames for :-
(a) Window type AC of any make capactiy 1.5 Ton cap complete all as specified and directed.
(b) Water coolers of any make and cap 40 to 150 ltrs capacity complete all as specified and directed.
(c) Split type AC of any make and capcity 1.5/2 ton complete all as specified and directed.
(d) Deep freezers of any make & cap 200 to 425 ltrs capacity complete all as specified and directed.
S&F in replacement of PCB of split type AC Cap 1.5/ 2 TR as per existing make and model complete all as specified and directed.
S&F, replacement to air filters of split type AC of 1.5/2.0 TR capacity as per existing pattern complete all as specified and directed.
S&F in replacement Submersible PVC pump for desert cooler 230 volt single phase 50 HZ complete all as specified and directed. Make : Khaitan/Universal or equivalent.
S&F in replacement of fan motor copper wound for desert cooler for operation on AC single phase 230 / 250 volts 50 HZ 1440 RPM complete all as specified and directed . (Make:- Khaitan/ Victor/ Americal/ Universal)
Supply & replacement of wood wool pad ( Set of three) heavy duty for desert cooler complete all as specified and directed.
Supply & fixing in replacement of capacitor 4 mfd complete all as specified and directed (Make Usha/Universal/Epcos)
Supply & fixing in replacement desert cooler fan blades made of galvanised iron sheet of appropriate thickness complete all as specified and directed
M&L for cleaning after taking down complete body including fitting and fixtures of desert coolers of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparationand cleaning of surface for painting and applying two coats of synthetic enamenl spray paint inside and outside surfaces and applying two coats rubber seal paint inside the water tank, etc, complete all as specified and directed.
S&F in replacement of 3 Pin Top, 5 Amp for desert coolers, complete all as specified and directed.
Taking down defective /unserviceable water cooler (capacity 40 ltrs) reciprocating compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed.
Taking down defective /unserviceable refrigarator (upto capacity 260 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed.
Taking down defective /unserviceable Refrigrator (upto capacity 320 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed.
NOTES APPLICABLE TO ITEM NO.100 TO ITEM NO. 186:-
(1) The contractor shall keep all items readily available at site, which is required for urgent repair works of appliances.
(2) In case of absence of manpower without providing suitable replacement an amount of Rs 1000/- per day shall be recovered as liquidated damage per person per day from the bill.
(3) Common miscellaneous material such as screws any type, nails, washers, insulation tapes, clamps, hooks, which are required for the work the cost of which is deemed to be included in quoted rate.
(4) All tools &tackles, plants, machineries, equipment and material to carry out the work at site which is to be decided by GE (A) Bhuj shall have to be provided by the contractor at his/ her own cost. Workshop shall be setup for rewinding/ repair of ceiling fan, exhaust fan, wall mounted fan, refrigerator, deep freezer & desert cooler. Rewinding machine should be installed in workshop with the latest configuration.
(5) Contractor’s supervisor (electrical engineer) should be available at the site to supervise the works and co-ordinate with the officials.
(6) The electrician on duty round the clock will have to be available at the site service centre created by the contractor & should have mobile phone. In case of absence of electrician, Rs 500/- will be levied as penalty for each instance.
(7) The manpower shall be issued identity card after getting due verification. Uniform should be worn by the manpower having monogram of the firm.
(8) The skilled worker should be facilited with mobile phone to contact on urgent tasks & their numbers should be displayed at various places and forwarded to administration.
(9) The contractor shall ensure safety of his workers and other at site of work and shall be responsible for any consequence arising out of execution of the repair and maintenance works.
(10) The contractor shall ensure that his repair/ maintenance staff is qualified and licensed for their part of work. He shall be responsible for their conduct. The contractor shall be held responsible for any loss or damage to employees’ state insurance corporates property.
(11) All repair and maintenance related complaints shall be attended within two hoursfailing, which a recovery of Rs 500/- per event per hour shall be made from the subsequence payment of the contractor.
(12) The date of repair, unit name & serial number shall be mentioned in neat sticker in the appliances after repair.
(13) Contractor is to collect the faulty appliances from units & return them after repair within a week. No separate charges shall be given for transportation.
(14) To carryout the serving of AC, refrigerator, deep freezer & water cooler, following T&P should be brought at site (service centre):-
(i) Drilling machine for making hole in wall.
(ii) Jet spray for cleaning of indoor and outdoor units.
(iii) Vacuum cleaner
(iv) Ref mechanic tools kit
(15) It is responsibility of contractor to clean the area after repairwork of appliances. Rates are deemed to be include in his quoted rates of respective items.
(16) The same nature of complaints in same location shall be counted as one complaint in internal electrification. Job card and complaint register for entry of complaints shall be provided at his/ her own cost.
(17) The contractor provide test certificate of material to be incorporated in the work.
(18) Any of contractor persons causes damage of equipment or property of Militart station, the contactor will be solely held responsible for the cost of consequences thereof.
(19) In the event of the contract work getting delayed due to reasons attributable to the contractor, the department shall be levying the penalty at the rate of 5% per week to the maximum of 10% of the contract value.
(20) Contractor shall carry out all test. The equipments shall conform to Indian standards.
(21) Contractor shall identify the real cause of burned winding of fan motor. Winding problems that are identified should be documented. Then, winding of fan motors shall be cut/ removed completely in presence of officials. Rewinding of same shall be carried out with proper copper gauge wire.
(22) Work diary & hindrance register of maintained by the contractor. The both shall be deposited to department daily.
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
sudarshan builders (BID ID -3136312)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .