| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹13.5 LAccepted-AOC | L-1 | Accepted-AOC AOC | |
| 2 | L-2₹16.3 L+₹2.8 L (20.6%)Rejected-Finance PLOT NO 52 SIDDARTH PARK BEHIND ICE FACTORY RAVALWADI BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹16.5 L+₹2.9 L (21.7%)Rejected-Finance VILLAGE BHANADA TEH ABADASA DISTT KUTCH PIN 370645 GUJARAT | KACHCHH | GUJARAT | 370645 | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹17.6 L+₹4.1 L (30.1%)Rejected-Finance C O ABDUL GANI ISMAIL NALIYA KUTCH PIN 370655 GUJARAT | KACHCHH | GUJARAT | 370655 | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹21.2 L+₹7.7 L (56.6%)Rejected-Finance OPP RAM MANDIR NALIYA KUTCH 370655 | KACHCHH | GUJARAT | 370655 | L-5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
29 Aug 2023, 6:00 pmClosed
GE AF Naliya No 1
GE Air Force Station Naliya No 01
REPAIR REPLACEMENT OF CEILING FAN ESHAUST FAN WALL PEDESTAL FAN AT DOMESTIC AND TECHNICAL AREA AT AF STN NALIYA
2023_MES_606173_2
8896/E8
Open Tender
Civil Works
Item Rate
270 days
Naliya
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF Naliya No 01
₹30,000
Yes
7 Mar 2024
8 Aug 2023
6 Sept 2023
8 Aug 2023
29 Aug 2023
16 Aug 2023
Amount
S&F in replacement of LED 43 watt luminaire recessed mounted 2x2 suitable for armstrong/grid ceiling including electrical connectin with suitable size cooper cable two core including taking down old Unsv fittings any type by disconnecting of electrical connection etc all as directed etc all as specified and as directed.
S&F in replacement of LED edge 36 watt luminaire recessed mounted 2x2 suitable for armstrong/grid ceiling including electrical connectin with suitable size cooper cable two core including taking down old Unsv fittings any type by disconnecting of electrical connection etc all as specified and as directed.
S&F in replacement of 18 W LED recess mounting 1x1 suitablr for armsstrong/grid ceiling including electrical connection with suitable size copper cable two core including taking down old unsv fittings any typeby disconnecting of electrical connection etc all as specified and as directed.
M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition.
M&L for Spot Cheking Serviceability of ceiling fan, exhaust fan, wall mounted fan,pedestal fan,and ensure all accessories like splite pin,fan hook,rubber,clamps nut and bolt,capacitor,down rod etc and refixing the appliances after the checking/servicing or replacement of accessories,as required complete all as specified and directed. Note:-(I) The work shall be carried out in occupied quarters and the part replace will be measured under relevant items as supply only. (II) The work shall be carried on specific numbered docket issued by EIC/JE and after checking of servicability/repair,contractor shall obtained the sign of the user and return the docket for payment action. (III) All tools and plants required for the work shall be arrange by the contractor.
Taking down ceiling fan/Exhaust fan /wall monted fan/pedestal fan of any make and sweep,cleaning externally and internally. Stripping out the fans, examine the unserviceable spares/ burnt winding by testing, cleaning and lubricating bush/ bearings. Refixing the fans in same position after necessary repairs/ servicing including carring out the replacement worn out parts, body covers, screws, spilt pins nuts condensor and flexible wire copper conducter from ceiling fan to ceiling rose etc complete all as specified and as directed. Note: (i) The parts replaced will be measured under relevant item as "Supply Only" (II) All tools and plants required for the work shall be arrange by the contractor.
Removing defective winding and rewinding with new super enamelled copper wire of existing gauge and weight as per manufactures design and instructions including insulating materials and varnishing of ceiling fans of of size 1200/ 1400mm sweap of any make and re-assembling testing complete and refixing to the location including replacement of flexible copper wire from ceiling rose to ceiling fan all as directed and specified
Description all as per srl item no 7.00 here-in-before but exhaust fan of size 300/380 mm sweep.
Description all as per srl item no 7.00 here-in-before but exhaust fan of size 400/450 mm sweep.
Description all as per srl item no 7.00 here-in-before but pedestal/Wall mounted/Air circulator fan of size 400/450 mm sweep.
Supply only Rubber bush for shackle with bolt, nut and lock pin suitable for Ceiling fan 1200mm / 1400mm sweep of ceiling fan of 1200mm / 1400mm sweep,exhaust/wallmounted fans of different make required as per the makes of existing fans as required at site or in winding shop complete all as specified and directed.
Description all as per srl item no 11.00 here-in-before but PVC holder for condenser housing.
Description all as per srl item no 11.00 here-in-before but Split Pin
Description all as per srl item no 11.00 here-in-before but Ball bearing of size No 6201/6202/6203
Description all as per srl item no 11.00 here-in-before but Gun metal bush as per sample.
Supply only Condenser (capacitor) 3.15/2.5 MFD, 440 Volts, AC 50 Hz as per IS 1709 suitable for ceiling fan 1200/1400 mm sweep complete all as specified and as directed.
Supply only Condenser 4 MFD, 440 Volts, AC 50 Hz as per IS 1709 suitable for exhaust fan 300/380/450 mm sweep complete all as specified and as directed.
S&F down rod of length appx (3 Feet) by removing and refixing of any type of ceiling complete all as specified and as directed.
S&F down rod of length appx (2 Feet) by removing and refixing of any type of ceiling complete all as specified and as directed.
S&F fan hook made out of MS Flat/round bar of suitable size with nut and bolts complete all as specified and as directed.
KALIKAY ENTERPRISES
SHREE MOMAY CONSTRUCTION
S and G Construction
M/s. Shree Shakti Enterprise
GEE CEE ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .