Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC C O ABDUL GANI ISMAIL NALIYA KUTCH PIN 370655 GUJARAT | KACHCHH | GUJARAT | 370655 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹47.6 L+₹39,961.82 (0.85%)Rejected-AOC PLOT NO 52 SIDDARTH PARK BEHIND ICE FACTORY RAVALWADI BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹49.3 L+₹2.1 L (4.51%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
3 Mar 2022, 6:00 pmClosed
GE AF Naliya No 1
GE Air Force Station Naliya Kutch 370655
SPECIAL REPAIR TO PAY LOAD AND BOREWELL ADDN ALTN TO GAS BANK AT AF STN MOTHALA BHANADA UNDER GE AF NALIYA
2022_MES_504466_2
8810/E8
Open Tender
Civil Works
Item Rate
270 days
Naliya
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE AF Naliya No 1
₹88,000
Yes
22 Apr 2022
4 Feb 2022
5 Mar 2022
4 Feb 2022
3 Mar 2022
18 Feb 2022
Amount
Dismantling structural Steel work including doors, gates but excluding framed truss complete all as specified & directed.
S & F framed work as in door or gate of angle or other section with gusset plates, rail braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting also fastening and fixing complete conforming to Fe-410 -0 or Fe-310-0 complete all as specified & directed.
S & F stairs (framed ) including stringers, treades, landing, balusters, hand rail etc including cleats, brackets complete all as specified & directed.
S&F Roof trusses (framed ), trussed, purlins, crane gantries , rails and fastening and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified & directed.
S & F mild steel hold fast etc conforming to Fe-410-0 or 310-0 complete all as specified & directed.
M &L for cutting holes in brick wall for inserting hold fast etc build in CM of depth exc. half brick and n.exc one brick wall and n.exc one brick wall making good in CM (1:3) or PCC (1:2:4) type B-0 complete all as specified & directed.
Dismantling expanded metal, any thickness or mesh, fixed with steel or wood fillets n.exc 4 kg/sqm if any type of mesh complete all as specified & directed.
M & L for 4 mm dia galvanised steel wire, 150 x 100 mm mesh, made up into mattresses or cages, lapped, ired and laid in position , including closing after filling complete all as specified & directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc.. Laod bedded and pointed in any mortar completed all as specified complete all as specified & directed.
M & L machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified & directed.
M&L for precast cement concrete block masonary walling with solid blocks of PCC (1:5:8) using 20mm graded stone aggregates, n. exc 10cm in width and sett in cement plaster (1:4) including complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc 0.50 cum, in soft soil and getting out, returning , filling in and ramming earth in layers not exc 25 cm, watering and removing surplus soil to a distance not exc 50 m and making good surface complete all as specified and directed.
M & L for PCC 1:3:6 type C-2 (by using 40 mm graded stone aggregate) as in foundation filing and mass concrete complete all as specified and directed.
S & F mild steel screw bolts 5 to 10 cm long and 5 to 10 mm dia of shanks with hexagonal head at one end and screwed other with fitted nut and washers complete all as specified and directed.
M & L for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L for two coats synthetic enamel paint over a coat of red oxide promer on new steel surfaces incl preparation of surfaces over exc 10 cm width or girth complete all as specified and directed.
M & L for two coats synthetic enamel paint over a coat of red oxide promer on new steel surfaces incl preparation of surfaces not exc 10 cm width or girth complete all as specified and directed.
Taking down chowkats or frames (without taking of shutter from the frame) but exc 1.50 sqm but n.exc 4 sqm each complete all as specified and directed.
S & F in stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples/wooden beads complete all as specified and directed.
S & F aluminim door shutter not less than 1.50 mm thick of section aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips rubber neoprene packing, handles 2 Nos in each door hinges anodised aluminium snap beading screws etc including taking down door frame with shutter complete all as specified and directed.
S & F aluminium widow/ventilator fixed type with two track of sec 85.00 mm x 31.75 mm 1.50 mm thick section No 78687, 24758 shutter of sec 18 x 40 x 1.25 mm (Sec No 8663/8664/8665) with rubber gasket beading and locking arrangemet etc complete all as specified and directed. (Note: Glass shall be measured and paid separetely)
S & F aluminium anodised grill of 7 mm dia rod square , rectangular, circular or similar type of shape aperture not exc 7.00 cm in length or width fixed with H or F Channel 38 mm x 12 mm x 1.30 mm (Sec No 8778 Make Grill No 20 of Decoare or equivalent fixed in repair complete all as specified and directed.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubing down with water etc including removing debris out side MD land complete all as specified and directed.
M & L for rendering 15 mm thick on fair faces of concrete surfaces in two coats i.e (10 mm + 5 mm) 10 mm thick as backing coat in CM (1:6) and 5 mm thick as finishing coat C:M (1:4) complete all as specified and directed.
M & L for preparing newly plastered or unplastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M & L for cutting and widending existing cracks on walls not exc 10 cm in girth and then filling in CM (1:3) including making good to match with the existing finish complete all as specified and directed.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises/MD land complete all as specified and directed.
M & L for non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc screed bed or bed in layer of mortar 15 mm thick for laying floor finishers set and jointed in neat cement slurry and cement to match complete all as specified and directed.
M & L for glazed ceramic tiles in vertical serface 300 x 200 x 7 mm thick set over rendering 10 mm thick on fair faces of brick work or concrete surfaces and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified & directed.
S & F 18/19 mm thick pre-laminated particle board, inerior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination & other side balancing white lamination , fixed with screws to timber frame work.
M & L for complete removal of existing treatement on walls of any description and preparing surfaces of walls and applying two coats of 100% anti fungal paint in two coats (in approved camouflaged pattern as directed) over one coat of primer complete all as specified and directed.
M & L for preparing plastered surfaces of walls and applying two coat of 100 % acrylic anti fungal paint (in approved camoflaged pattern as directed) over one coat of primer on complete all as specified and directed.
Demolition of RCC Chajja of any description and in any position complete all as specified and directed.
M & L for framed work such as grills, grating, etc with ends of bars should and riveted or forged into spikes, framed guard bars barred iron doors ladders, framed balusters, walk ways, railling, framed work of water tanks and similar work conforming to Fe-290 gde E-165 complete all as specified and directed.
M & L for Mild Steel bars TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking bending spirally for hooping columns, hooking ends and binding with and including mild steel wire (annealed) not les than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for precast reinforced cement concrete slab (nominal mix 1:2:4 type B-1 20 mm graded aggregate for chajja complete all as specified and directed.
M & L for preparing old plastered or unplastered surfaces of ceiling and applying one coat of white wash complete all as specified and as directed
M & L for complete removal of existing treatement and applying two coats of oil bound distemper white or tinted on wall surfaces over one coat of primer over one coat of wall care putty complete all as specified and as directed
M & L 0.63 mm black, corrugated mild steel sheeting with two corrugations side lap, fixed with coatch screws and washers, in roofs, walls and cover to rolling shutter top and wall face etc complete all as specified and directed.
M & L water proofing treatment on RCC roof etc… comprising with the following operation and as specified here in below Taking down/scraping out existing old tarfelt bituminous compound including sweeping, cleaning, washing down to remove dust etc and removing debris to a distance n.exc 250 m and applying 15mm thick plastering in CM 1:3 finished even and smooth preparing and cleaningof fully dried cement plasered surface apply one coat of cold bituminous primer to the plastered surface @ 1.50 kg per sqm conforming t IS 3384-1986 and applying a layer of APP bases polmeric membrance 3 mm thick (Minimum) weight 3.50 Kg per sqm reinforce withpolyster non woven fabric (Weight not less than 160 gms/sqm shall be applied over bituminous primer as specified above application of polymeric membrance shall be by torch application. The ovelap shall be 100 mm on transverse direction and 75 mm on longitudinal direction all as speicfied and as directed
E/M PORTION
M & L for drilling of 01 No pilot/trial bore by direct rotary rig method including all T & P through any kind of strata (soil, kankar, boulder or soft or hard rock) down up to 150m depth below ground level by using 215 mm dia drilling bit including the cost of mud pit, channels etc and disposal of soil obtained to a distance not exc. 1 km away complete all as directed. Note: (i) The drilling shall be continued up to specified depth and in case sticky clay occurs in between, the drilling must be stopped and Hydrologist of GWS & SB shall be contacted & Engr-in-Charge shall be informed. Cost of this consultation shall be borne by contractor. (ii) After completion of pilot bore, the contractor shall have to arrange for electro logging of each bore (water logging test with electro logging equipment which shall be measured and paid as separate item under this schedule). Reaming work should not be started in any case without electro logging of bore.
M & L for water logging test with electro logging equipment & required machinery for ascertaining / logging aquifers encountered in bore well and arranging and defining the water availability test giving test report of Geohydrologist from Govt. approved laboratory recommending water bearing zones, TDS of water etc. complete as directed by E.I.C. Note: The contractor shall submit electro-logging result with recommended bore assembly details in duplicate for approval of GE.
M & L for development of trial/pilot bore into tube well in alluvial strata complete by direct rotary rig method down up to the depth 30 m in bore well including removal of soil obtained up to a distance n.exc 1 Km and site clearance complete for reaming upto 650 mm dia bore hole for 300mm dia pipe.
Description all as per srl item No.45 here-in-before but for depth exc 30m to 60m
Description all as per srl item No.45 here-in-before but for depth exc 60m to 90m
Description all as per srl item No.45 here-in-before but for depth exc 90m to 120m
Description all as per srl item No.45 here-in-before but for depth exc 120m to 150m for reaming upto 550mm dia bore hole for 250mm dia pipe
Supply, install, testing & commissioning of Submersible borewell pump (CED coated pump casing), electric driven 415V, 50Hz suitable for 300 mm dia borewell, Head 110 meter at 900 LPM discharge (40 HP) for column pipe of size 100 mm bore, Bronze Impeller, Stainless steel motor casing, stainless steel pump shaft, stainless steel motor shaft, SS body motor including electric connection with pump starter complete all as specified and as direced.
Supply and fix in replacement Pipe ERW Steel including specials nominal dia 300 mm as per IS 3589 (1981) thickness 5.4 mm complete all as specified and as direced.
Description all as per srl item No.51 here-in-before but of 250mm bore (Nominal bore) complete all as specified and as direced.
S & F 300 mm x 250 mm threaded MS reducing socket heavy duty suitable for borewell MS casing pipe complete all as specified and as directed.
Supply, Lowering and fixing in position 300 mm bore MS Pipe strainer 5.4 mm thickness, horizontal slotting done by CNC Machines ,slot width right from 0.2mm to 3.00mm, slot numbers designate width of openings in thousand part of an inch, suitable for depth up to 250 meter depth, socketed, trapezoidal threads conforming to IS:12818 / DIN 4925 including necessary jointing complete.
S & F MS tail piece made of 250 mm bore suitable for borewell all as specified and as directed. Make:Supreme/Finolex/Prince/Kisan/SFMC/Sintex/Jain Irrigation/Reliance.
M & L for providing pea size gravels of size 4 mm to 10 mm all around the casing pipe to entire depth from ground level as required in packing of tube well complete all as specified. Note: Gravel shall be free from impurities such as shale, mids, clay, sand, hematite etc.
M & L for developing tube well with Air compressor not less than 265 CFM capacity with adjustable length of pipe till sand free potable water upto 10 PPM is obtained including testing the tube well for three consecutive days each of 8 hours after development and determining the yield by continuously pumping for 16 hours to deterime safe pumping yield complete all as specified & directed.
S & F a pair of MS clamp made of 150 mm x 20 mm x 0.6 mtr long MS plate size as required for holding the casing pipe including drilling holes and necessary nuts, bolts, washers etc of suitable size complete all as specified & directed.
M & L for MS well cap in replacement made of 3 mm thick MS sheet suitable for 300 mm bore housing pipe incl necessary washer/gasket etc complete all as specified and as directed.
Supply and laying in replacement 110mm bore HDPE Pipes class PN 10 as column pipe, ISI marked including steel rods of applicable dia for taking up / down Borewell Pump for future maintenance etc.
Supply and Fix/Laying in replacement PVC insulated 3 core 16 sq mm Copper multi stranded PVC sheathed flexible, flat, submersible cable ISI marked and conforming to IS 694 and connecting to submersible pump and to LT panel complete all as specified & directed.
Supply and fix in replacement 100mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line complete all as specified & directed.
S & F in repair CI Butterfly valve 100 mm dia designed line pressure: class 1.6 conforming to IS 13095 complete all as specified & directed.
M & L for construction of valve chamber, size 1050x750x1000mm (internal dimension) for valve etc. with PCC foundation, block masonary walls, Plastering, PCC Coping, white washing, MS chamber cover, painting to MS cover incl Excavation and earth work in any type of soil complete all as per drg No.CEAA/TD/57 and specified as per specification given below:- (i) PCC for foundation (1:4:8) type D2 (40mm graded stone aggregate)150 mm th extended up to 150 mm beyond the outer face of block masonry. (ii) Walls of valve chamber 200 mm thick with precast cement concrete (1:5:8) (using 20mm graded stone aggregate) solid building blocks , setting in CM 1:6 complete. (iii) Internal and exposed surfaces of valve chamber both concrete and block masonry surface shall be plastered with CM (1:4), 15 mm thick finished even and smooth. (iv) 50 mm thick coping in PCC 1:3:6 type C1 over block masonry wall. (v) Entire plastered surfaces shall be treated with 3 coat of white wash. (vi) Chamber cover shall be of 3 mm thick mild steel plain black sheet with hold fast and locking arrangement. Cover shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer.
S & F in repair cast iron Non-Return sluice valve (Reflux valve), class PN 1.6, swing check type 100mm dia all as per IS 5312, flanged type with 2 Nos of 3mm thick rubber gasket joints with MS hot galvanised nuts, bolts, washers etc of suitable size and numbers complete all as specified & directed.
S & F cast iron air release valve 100 mm dia with two orifice/outlets conforming to IS 14845 flanged type with 2 Nos of 3mm thick rubber gasket joints with MS hot galvanised nuts, bolts, washers etc of suitable size and numbers complete all as specified & directed.
S & F in trenches ductile iron pipes, socket and Spigot ends, of 100mm bore, ISI marked Centrifugally Cast (Spun) Ductile Iron Pressure pipes conforming to IS:8329/2000 classification K-9 rating, suitable for push-on-joint(Rubber gasket-D jointing) with cement mortor lining inside the pipes and outside zinc coating with Bituminous finish coat as per IS:8329/2000 including rubber joints conforming IS: 5382 of 1985 complete all as specified & directed.
M & L for PCC 1:4:8 Type D-2 (40mm graded aggregate) in foundation, thrust block, filling and mass concrete complete all as specified and directed.
Supply & lay in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 120 Sqmm 3.5 core, including taking down old USNV Cable any make and type complete all as specified and directed.
Excavation in trenches n.exc 1.5 m depth and n.exc 1.5m in width, n.exc 10 sqm on plan for foundation etc and getting out in soft / loose soil complete all as specified & directed.
Returning filling in soil including spreading leveling watering & well ramming in layers n.exc 25cm thick complete all as specified and as directed.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Supply and Lay factory made un reinforced precast concrete cable cover LV Type I with flat size 250mm X 150mm X 40mm complete all as specified & directed.
M & L for providing dry river sand as in cushioning to under ground cable including punning down of sand in layer complete all as specified & directed. Note: For measurement purpose punned thickness of sand will be considered.
M & L for Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised earth lead GI strips 25 x 4 mm by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part I of 2009 & as specified or indicated and testing on completion including charcoal, salt, excation/earth work in any type of strata PCC ( 1:3:6 ) type C1, earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), cast iron frame, funnel with wire mesh,GI watering pipe of 20 mm bore medium grade and lugs, with and including GI earth wire 4 mm dia with GI protection pipe of 15 mm medium grade of length 7.5 meter, etc complete all as specified. Note: Earth strip/wire and GI protection pipe up to length 7.5m shall deemed to be included in rate of above item.
M & L for Ductile iron fittings upto 150mm dia bore size all as per relevant IS suitable for use with DI pipes such as bends (any radius, any type), tapers, double flange, double socket, tail piece, cross, y branch, collars, sockets etc all as per site requirement and as specified and as directed by Engr-in-Charge.
M & L for cutting existing DI/CI pipe of 150mm dia for branch connection of 100mm DI pipe complete all as specified and as directed by Engr-in-Charge. Note : DI specials will be measured and paid separately.
M & L for carrying Chemical analysis of Borewell water sample in any Govt / SPCB approved / NABL accredited lab & submission of Test Report. Tests to be carried out are as under:- (a) Chloride (b) Total hardness (c) Sulphate (d) Total Dissolved Solids (TDS) (e) pH (f) Turbidity in NTU (g) Inorganic matter (h) Organic matter (i) Total alkalinity (j) Total acidity’ Note: Quoted rate shall be deemed to be included collection of water sample from site
M & L for sanitary sealing of tube well with PCC (1:2:4) type B1(using 20mm graded stone aggregate ) upto and a depth of 1mtr below ground level and 0.45 mtr above ground level (square type external dimension 600mm x 600mm) around tube well casing, platform of external dimension 1200mmx1200x150mm at ground level with PCC 1:4:8 type D2 foundation (using 40mm stone aggregate) including necessary form work and supply and placing of 80mm bore light grade GI pipe, at two places each 1.5m in length for pouring of pea gravel / water and capping with screwed cap at top etc complete
M & L for strata sample collection (at every 3 mtr depth) one set in suitable box pattern, each sample strata should be produced and submitted to department. Note: (a) Scope of work under subject tender is for 02 nos of borewells and quantities mentioned here under are inclusive of 02 borewells. (b) The following information shall be furnished by the contractor on completion of the tubewell:- (i)Total depth of tubewell drilled, (ii)Strata chart of the tubewell indicating different type of soil formations met with at different depths and indicating the depth of each type of soil formation, (iii) Samples of strata collected, neatly packed and correctly marked in sample bays, (iv) Position of every joint in well assembly, (v) Method used for development, (vi) Total hours of development done, (vii) Developed discharge in L.P.S., (viii) Discharge is totally sand free or presence of sand particles is there, (ix) P.P.M. and turbidity after development, (x) Pumping water level at developed discharge, (xi) Static water level. The cost of above scope shall deemed to be included in quoted rate. (c) The tenderer shall note that the work is of a specialist nature and shall be got executed by engaging specialist bore well construction agency who have past experience of successfully executing tube well works and have all the necessary equipment. The contractor shall get the bore well agency approved in writing from the GE before execution/commencement of the work.
Supply and install air coold split unit Air Conditioners (Copper) electric driven single Phase 230 Volts of capacity of 1.5 TR indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum BEE 5 star rating complete all as specified & directed.
Supply and fixing/drawing wiring for Circuit / Submain wiring with PVC conduit of suitable size inclusive of all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories including all fixtures /fittings fixed on wall/ceiling along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed as required of 2 x 4.0 sqmm and 1 x4 sqmm as earth wire Complete all as Specified & directed.
Supply and fix Industrial exhaust fans AC single phase 230/ 240 V of size 600 mm sweep 700 revolution per minute heavy duty with blade and frame & louver of metal body material complete all as specified & directed.
Provn of making hole in block masonry/stone wall of suitable size for fixing of exhaust fan 600 mm sweep including making good surface with smoothing of surface and painting of one coat of primer and one coat of paint as per existing paint at disturbed area complete all as specified & directed.
Supply and fix in replacement industrial plug and socket with single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 20 Amps capacity complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
Material and labour for concealed conduit point wiring with single core PVC insulated and unsheathed 1100 volts grade multi-stranded copper conductor cable of size 1.5 sq. mm (Nominal area) drawn through & including PVC conduit, heavy duty (ISI marked) not less than 20 mm dia. concealed in wall, ceiling with GI saddles, GI screws, rawl plugs with all fittings including tees, junction boxes & including metal flush box and blank plate of suitable size for mounting switches, sockets & regulators & drawing continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with copper solid conductor of size 1.5 sq. mm (nominal area) complete all as specified and as directed by Engineer-in-Charge for the following :- (Note: Cost for cutting chases and making good to match the existing surface shall be deemed to be included in the quoted rate.) (a) One light point / fan point controlled by one,one way switch single pole modular type
Description all as per srl item No.88 here-in-before but One 3 pin 5 Amp socket outlet on same board
Description all as per srl item No.88 here-in-before but One 3 pin 5 Amp socket outlet on ind board
Description all as per srl item No.87 here-in-before but with 2.5 sqmm multi-stranded copper conductor cable with 1.5 sqmm earth wire for one 6 pin socket outlet 5/15 Amps on independent boared all as specified and as directed.
Supply and fix modular Switch , 5/6 Amps, Single Pole, one way, 230 Volts complete all as directed.
Supply and fix modular Switch socket out let ,multi purpose,3 pin ,5/6 Amps,flush type,230/ volts complete all as directed.
Supply and fix modular Switch socket out let ,multi purpose,6 pin ,5/15Amps,flush type,230/ volts complete all as directed.
Supply and fix Ceiling rose,surface,bakelite,65 x 50mm,three terminals complete all as specified and all as directed.
Material and labour for concealed PVC conduit submain wiring with 2 core PVC insulated and unsheathed 1100 volts grade multi-stranded copper conductor cable of size 2.5 sq. mm (Nominal area) drawn through & including non-metallic rigid PVC conduit, heavy duty (ISI marked) not less than 25 mm dia. concealed in wall, ceiling with GI saddles, GI screws, rawl plugs with all fittings including tees, junction boxes continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with copper solid conductor of size 1x1.5 sq. mm (nominal area) complete all as specified and as directed by Engineer-in-Charge for the following :- (Note: Cost for cutting chases and making good to match the existing surface shall be deemed to be included in the quoted rate.)
Material and labour for concealed PVC conduit submain wiring with 4 core PVC insulated and unsheathed 1100 volts grade multi-stranded copper conductor cable of size 10 sq. mm (Nominal area) drawn through & including non-metallic rigid PVC conduit, heavy duty (ISI marked) not less than 25 mm dia. concealed in wall, ceiling with GI saddles, GI screws, rawl plugs with all fittings including tees, junction boxes drawing continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with copper solid conductor of size 2x6 sq. mm (nominal area) complete all as specified and as directed by Engineer-in-Charge for the following :- (Note: Cost for cutting chases and making good to match the existing surface shall be deemed to be included in the quoted rate.)
S&F in replacemet Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB of capacity 63 Amps all as directed by EIC.
Supply and fix in replacemet LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified & directed.
Supply and fix in replacemet LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified & directed.
Supply & fix in replacemet LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed.
Taking down carefully of Ducted Split AC unit 11 TR with Scroll Compressor, Microprosser based, LCD based remote control unit with ODU - 02 No. in Paylod Bldg left Side and right side and refixing at ground floor with the help of angle iron frame including wiring, Ref gas R-22 charging (if less), copper piping and connected wiring/cabling etc commisioning and testing complete including internal ducting minor repair and maintenance . Make:- Blue Star, Model: DSA1321R1.
KALIKAY ENTERPRISES
baghela construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .