Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹19.0 L
EMD Value
₹37,920
Closing Date
4 Dec 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Improving the aesthetic and livability of Baramulla town by installation of laser-cut designer pole lights, high mast lights, graffiti and wall painting, and installations of twin road side dustbins B.W.O Supply, Installation, Testing and Commissioni
2025_PWDJK_296180_1
NIT No.199/2025-26 Dt/21/11/2025
Open Tender
Electrical Works
Percentage
30 days
Baramulla
Please refer Tender documents.
4 documents required · 4 mandatory
₹800
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹37,920
24 Nov 2025
24 Nov 2025
5 Dec 2025
24 Nov 2025
4 Dec 2025
24 Nov 2025
Part A: Supply and installation of Laser-cut Designed Poles
SITC of ISI marked Lazer Cut decorative outdoor LED light fixture post, complete with mild steel pole and integrated luminaire housing suitable for pathway/park illumination, including all accessories as required for proper installation, operation and commissioning. Technical Specifications: Material: Mild Steel pole and luminaire housing. Pole Height: Approx. 3.45 m (overall) with 574 mm luminaire head. Pole Size: 220 mm square with decorative perforation design. Base Plate: 350×350 mm with 4 nos. Ø18.5 mm holes on 282 mm PCD. Coating System: Shot blasting pre-treatment, epoxy primer, and UV-resistant PU/polyester powder coating. Light Source: High power, high efficiency LED chips mounted on MC PCB. Heat Sink: Aluminium heat sink with thermal paste for effective heat transfer. Protection: IP65 (optical area) with silicon rubber gasket sealing system; IK06 impact protection. Electrical Parameters: LED Wattage: 40 W (perforation) / 4×36 W (luminaire) Rated Voltage: 230 V AC, 50 Hz Power Factor: >0.95 THD: <10% Surge Protection: 4 kV driver with 10 kV SPD CCT: 5700 K (as approved by Engineer-in-charge) Mains Current: <1 A Driver: High-efficiency LED driver pre-wired up to terminal block in junction box. Mounting: On suitable RCC foundation with necessary anchor bolts, nuts, and washers (foundation bolts included in scope). Ingress Protection: IP65 rated optical assembly with silicon gasket sealing. Complete with internal wiring upto pole box. Make as directed by Engineer in charge. The job/ contract includes 03 years replacement warranty for lighting fixtures after DLP (from date of successful completion of work)
Supply/Laying/Connecting and Commissioning of 35 sq.mm 2-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/Eq. Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution)
Supply/Laying/Connecting and Commissioning of 16 sq.mm 2-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/Eq. Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution)
Supply, installation, testing and commissioning of pole-mounted weatherproof pole box fabricated from 1.6 mm thick CRCA sheet steel, duly powder-coated for outdoor use, suitable for mounting on laser-cut decorative poles using stainless steel clamps and fasteners.The pole box shall be provided with a hinged, lockable, and gasketed front door to ensure IP65 protection against dust and moisture. It shall be prewired with suitable copper flexible wires, MCB (16 A SP), 16 A connector strip, and cable glands for loop-in loop-out cable termination.The box shall be compact, rust-resistant, and aesthetically matching the pole design, complete in all respects as per engineer-in-charge directions.
Supply/ installation/testing and commissioning of CPRI Approved (IS/IEC:61439) panel outdoor type , Mian Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel and grouted in concrete .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices (1) Normal Incoming 100 Amp DP MCB 10 kA with thermo magnetic adjustable based of Legrand / Siemens/ ABB /Schinder /L&T/Havells make = 1 no 150 Amp SPN Bus bar Al Strips = 1 Set Outgoing: 63 Amp DP = 2 No. for Supply to the Lights
Part B: Supply and Installation of High Mast Lights
Supply/Erection/Installation/Testing and Commissioning with transpotation at site of polygonal shape 12.5 mtr High mast pole (BPP/Utkarsh/Bajaj/Havells or Equivalent make) with its accessories. Mast shaft shall be in two section, made from H.T. Steel of grade BSEN10025,S355 or Equivalent hot dip galvanised and suitable for wind speed 180 km/hr as per IS 875. It should also included acc. for hight mast including head fame, two continuous steel wire rope 6mm dia ( Grade AISI 316), tailing cable, double drum winch galvanised lantern carriage arrangement suitable for 06 No. luminaries installation symmetrically and its control gear box, 01 HP motor Single Phase, manual operating handle, motor mounting plate, L staper , Lightening arrester , Junction box, including foundation acc. the mast shall have an integral power tools installed inside the base compartment for its operation. Luminaries wiring materials including in the mast supply price. Technical Specification. Bottom 360 mm, top- 150 mm thick , 3mm Top section & Bottom Section 4mm - 2No.,Baseplate 540 mm dia, baseplate thickness- 25 mm. foundation bolt size 30 mm dia Bolt length 850 mm, No. of hole 06 No. Foundation bolt 06 No. Wire rope 6mm SS 304 grade (Full Specification Enclosed)
Construction of suitable shallow foundation b.w.o of Providing and laying of ( 5ʹ x 5ʹ x 6ʹ) bed underground foundation including soling150mm,mudmat 100mm in 1:4:8 mix and placing of RCC and in position specified grade of reinforced cement concrete including curing ,cost of centering, shuttering, finishing and reinforcement, with 1:1½:3 (1 cement:1½ coarse sand :3 graded crushed stone aggregate 20 mm nominal size) approved by site incharge.
Design/Supply/Fixing/Testing and Commissioning of Single door having 1.5′x2′x9′′ width of sheet metal painted vermi rain proof and having stand of 50x50x6mm angle iron of height 3 feet above ground, grouted in cement concrete block of 1:1.5:3 ratio 12" depth and having 2"dia G.1 loop in - loop out pipe for in/out of cables/wires. Panel duly designed with Single door glanded slopped top cover, lockable and the panel having 2 No. of 100 Amp bus bars & din bars for mounting of DP//MCB. LTMS feeder control Panel Providing the following component (switching acc.) inside the Panel including internal wiring & Suitable No. of Thimbles all. 1) 63 A DP 1 No. 2) 240 V contractor- 1 No. 3) By pass switch- 1 No. 4) outlet Terminal - 2 No. 5) Starter for motor operation (Forward and Reverse direction )- 1 No. 6) 32 A DP -1 No.7) 03KVA Single Phase Digital Stabilizer Housed in same Panel.
Supply/Laying/Testing and Commissioning of ISI marked or as directed EIC of 200 Watt. LED with 160-245 volt operating voltage with glass reflector,drivers,Surge Protector device and holding bracket and anchor/holder as per site requirement on approval of site Incharge fixture complete in all respects including 3x2.5mn sq. service connection wire. The job includes AMC for lighting fixtures for a period of three years after successful commissioning of work
Supply & Fixing of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 3 mtr long through GI Strip (25x3)mm
Supply/Laying/Excavation/Testing and Commissioning of 2 Core 16 mm sq. Al armored PVC cable Havells/Polycab or Equivalent Make. Including supply/laying of HDPE Pipe of 01 inches dia. The job includes excavation of soil, back filling, ramming and spreading of warning tape at 300mm depth and disposal of excess soil/debris at convenient location. Including Road cut wherever required and refilling of same with cement concrete.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.05 MB
BOQ_959423.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .