Loading…
Loading…
Tender ID
Tender Value
Refer Docs
EMD Value
₹6,281
Closing Date
11 Feb 2026, 2:00 pmClosed
Assistant Executive Engineer
PWD Electrical Sub Division, Thalassery
DEPOSIT-SITC of UPS at Revenue Offices - Taluk Office Payyanur - SITC of 5 kVA UPS at Taluk Office Payyanur-General Electrical Work
2026_PWD_833598_1
PWD/BLDG/TR/4757/2024_6_39_37
Open Tender
Electrical Works
Item Rate
90 days
Taliparamba
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
₹6,281
4 Feb 2026
4 Feb 2026
13 Feb 2026
4 Feb 2026
11 Feb 2026
4 Feb 2026
SITC of UPS
OD292501/2025-2026:Supply Installation and testing and commissioning of 5 kVA online UPS pure sinewave with 120 min backup with tubular C10 battery with minimum VAH of 9600. a) 1 ph to1 ph with by pass arrangement, b) Input pf > 0.95 @ full load, c) Output pf : >.95 d) Input voltage range : 160V -280V with cut off e) THD .9 % g) Ambient Temperature : 0-40°C h) Generator Compatibility available. i) Pure sine wave. j) Battery over charge & under charge cut off. k) Bypass arrangement. i) EN/IEC620401 for General Safety compatibility j) LED/LCD Display with digital indications of Input V & A, output V & A, Battery charge, Temperature, frequency q) Approved UPS make : APC/Delta/Numeric, r) Approved C10 rated battery make:-Exide/Quanta/Amaron, s) Architecture Tower type only (rack mountable not acceptable. t)Marking CE, BIS, ROHS u) All certificates copy to be submitted. v)Three year warranty. Battery rack : Painted MS angle iron rack Suitable for the battery supplied.
OD157023/2025-2026:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 40 amps 240 volts "Two pole isolator complete with connections, testing and commissioning etc. as required.
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.2:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and netural
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
90.10.1.6:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
viewnit.pdf
Tender Documents • 0.02 MB
viewsbd.pdf
Tender Documents • 2.19 MB
mom.pdf
Other Document • 0.26 MB
specificcondition.pdf
Additional Documents • 0.34 MB
BOQ_1401910.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .