Assistant Executive Engineer
PWD Electrical Subdivision Malappuram
DEPOSIT- SITC of 3kVA/72VDC UPS system with 6 Batteries for replacement of non functional UPS and batteries at the Judicial First Class Magistrate Court-1, Tirur-UPS work under Buy back scheme-General Electrical Work
2026_PWD_880946_1
ELSDM-90/2026-27
Open Tender
Electrical Works
Percentage
180 days
Tirur
Please refer Tender documents.
11 documents required · 11 mandatory
₹555
₹3,107
17 Oct 2026
17 Oct 2026
27 Oct 2026
17 Oct 2026
24 Oct 2026
17 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Inverter System | |||||
| 1.001 | OD50635/2026-2027:Supply, Installation and commissioning of 3 KVA/72VDC Pure sine wave UPS the following specification. Capacity 3 KVA, UPS, Nominal input voltage 170 - 270 VAC, Single Phase Input Single Phase output, Nominal Input frequency 50 HZ +/_ 2Hz, Nominal output voltage 230 V AC Single phase, Output voltage regulation +/-1%, Manual Bypass Facility, Nominal output frequency 50 Hz, Output frequency tolerance +/-1%, Ventilation Forced Air cooled, LED/LCD Display for Mains on, Inverter on, Battery Low, Over Load, Trip, Load Percentage, Common Alarm Battery low, Over load with 6 nos of 12V/100Ah Tall Tubular Battery with Battery Rack and accessories. (make UPS Hykon, Luminous, Zenster, Delta Batttery Exide, Hykon, Luminous ) including buy back old inverter with battery (Buy back value Rs 5800/-) | 1 | each | 1,02,789.76 | ₹1,02,789.76 |
| 1.002 | OD50643/2026-2027:Supplying and fixing 4P sheet steel enclosure on surface/ recess suitable for fixing 4Pole Isolator, MCB, RCCB with connections, testing and commissioning etc. as required. | 1 | each | 699.73 | ₹699.73 |
| 1.003 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 1 | each | 459.78 | ₹459.78 |
| 1.004 | OD50641/2026-2027:Supply Conveyance, installation, testing and commissioning of 40A, double pole, single phase 240 volts, MCB type change over switch in the existing MCB DB complete with connections. | 1 | each | 2,119.54 | ₹2,119.54 |
| 1.005 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | 2 | each | 270.65 | ₹541.3 |
| 1.006 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | 50 | metre | 135.72 | ₹6,786 |
| 1.007 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm | 50 | metre | 217.78 | ₹10,889 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1498369.xls
BOQ • 0.31 MB
viewsbd.pdf
Tender Documents • 1.63 MB
List.pdf
Other Document • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .