Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.1 LAccepted-AOC | ₹24.1 L | 1 | Accepted-AOC awarded |
| 2 | 2₹24.2 L+₹13,324 (0.55%)Rejected-Finance NAIN BHAWAN BALVEER COLONY NEAR HOTEL BALSONS URBAN ESTATEB BYE PASS ROED PATIALA DISTT PATIALA | ₹24.2 L+₹13,324 (0.55%) | 2 | Rejected-Finance high bidder |
| Sl No | Description | Qty | Unit | APEX CONSTRUCTIONS L1 | GULADI INFRA PRIVATE LIMITED L2 |
|---|---|---|---|---|---|
| 1.00 | Dismantling brick work tile, masonry or tile lining in cement. | 16.54 | cum | 718.49 ₹11,883.82 | 400 ₹6,616 Lowest |
| 2.00 | Dismantling Reinforced Cement Concrete. | 3.63 | cum | 2,321.91 ₹8,428.53 | 2,000 ₹7,260 Lowest |
| 3.00 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. | 94.33 | cum | 73.4 ₹6,923.82 | 50 ₹4,716.5 Lowest |
| 4.00 | Excavation of Soil using Hyraulic Excavator and hydraulic Tractor Trolly I/C cutting and loading in Trolly and transporting to the embankment locations inlcuding all lifts and leads, excluding royality. Lead 3.00km (Rural Reach). | 821 | cum | 132.98 ₹1,09,176.58 | 50 ₹41,050 Lowest |
| 5.00 | Rehandling of Earth work. | 732.64 | cum | 35.82 ₹26,243.16 | 20 ₹14,652.8 Lowest |
| 6.00 | Plain cement concrete in sub-structure complete as per drawing and Technical Specifications. For PCC M-15 Grade. Using Batching Plant, Transit Mixer and Concrete Pump, i/c shuttering and vibrating etc but excluding steel reinforcement complete in all respect. | 21.16 | cum | 5,746.28 ₹1,21,591.28 | 5,500 ₹1,16,380 Lowest |
| 7.00 | Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications for RCC M-30 grade, Using Batching Plant, Transit Mixer and Concrete Pump, i/c shuttering and vibrating etc but excluding steel reinforcement complete in all respect. | 19.61 | cum | 6,300 ₹1,23,543 Lowest | 7,000 ₹1,37,270 |
| 8.00 | Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications for RCC M-25 grade, Using Batching Plant, Transit Mixer and Concrete Pump, i/c shuttering and vibrating etc but excluding steel reinforcement complete in all respect. | 108.92 | cum | 6,250 ₹6,80,750 Lowest | 6,900 ₹7,51,548 |
| 9.00 | Furnishing and Placing Reinforced cement concrete in super- structure as per drawing and Technical Specification for RCC M-40 grade for anti crash barrier, Using Batching Plant, Transit Mixer and Concrete Pump, i/c shuttering and vibrating etc but excluding steel reinforcement complete in all respect. | 11.18 | cum | 6,681.24 ₹74,696.26 Lowest | 7,000 ₹78,260 |
| 10.00 | Water Bound Macadam Grading I (without screening for low volume Roads/undersigned Providing, laying, spreading and compacting stone aggregates of Grading I towater bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheeled roller 8-10 tonnes instages to proper grade and camber, applying and brooming requisite typeof binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the requireddensity completeas per technical specifications | 29.7 | cum | 1,564.16 ₹46,455.55 | 1,000 ₹29,700 Lowest |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
28 Feb 2026, 2:00 pmClosed
Executive Engineer
Faridkot Canal and GW Division Faridkot
Estimate for Reconstructing Bridge at Rd 17160 of Manuke Disty.
2026_WR_160293_1
Estimate for Reconstructing Bridge at Rd 17160 of Manuke Disty.
Open Tender
Repair and Maintenance Services
Item Rate
40 days
JAGROAN
Pre Qualification Details
2 documents required · 2 mandatory
₹500
Yes
₹46,000
Yes
Faridkot
13 May 2026
14 Feb 2026
28 Feb 2026
14 Feb 2026
28 Feb 2026
14 Feb 2026
20 Feb 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Faridkot Canal Division, Faridkot
Name of Work: Estimate for Reconstructing Bridge at R.D. 17160 of Manuke Disty.
Contract No: 01639-250059
Name of the Bidder/ Bidding Firm / Company :
Sl. No. C.S.R Item No./Item Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
Dismantling brick work tile, masonry or tile lining in cement. cum Excess(+) Full Conversion INR
Dismantling Reinforced Cement Concrete. cum Excess(+) Full Conversion INR
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. cum Excess(+) Full Conversion INR
Excavation of Soil using Hyraulic Excavator and hydraulic Tractor Trolly I/C cutting and loading in Trolly and transporting to the embankment locations inlcuding all lifts and leads, excluding royality. Lead 3.00km (Rural Reach). cum Excess(+) Full Conversion INR
Rehandling of Earth work. cum Excess(+) Full Conversion INR
Plain cement concrete in sub-structure complete as per drawing and Technical Specifications. For PCC M-15 Grade. Using Batching Plant, Transit Mixer and Concrete Pump, i/c shuttering and vibrating etc but excluding steel reinforcement complete in all respect. cum Excess(+) Full Conversion INR
Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications for RCC M-30 grade, Using Batching Plant, Transit Mixer and Concrete Pump, i/c shuttering and vibrating etc but excluding steel reinforcement complete in all respect. cum Excess(+) Full Conversion INR
Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications for RCC M-25 grade, Using Batching Plant, Transit Mixer and Concrete Pump, i/c shuttering and vibrating etc but excluding steel reinforcement complete in all respect. cum Excess(+) Full Conversion INR
Furnishing and Placing Reinforced cement concrete in super- structure as per drawing and Technical Specification for RCC M-40 grade for anti crash barrier, Using Batching Plant, Transit Mixer and Concrete Pump, i/c shuttering and vibrating etc but excluding steel reinforcement complete in all respect. cum Excess(+) Full Conversion INR
Water Bound Macadam Grading I (without screening for low volume Roads/undersigned Providing, laying, spreading and compacting stone aggregates of Grading I towater bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheeled roller 8-10 tonnes instages to proper grade and camber, applying and brooming requisite typeof binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the requireddensity completeas per technical specifications cum Excess(+) Full Conversion INR
Water Bound Macadam Grading II Providing, laying, spreading and compacting stone aggregates of Grading II towater bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheeled roller 8-10 tonnes instages to propergradeandcamber, applying and brooming requisite type of screening/binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications cum Excess(+) Full Conversion INR
Laying First Class Dry Brick on edge flooring or paving inordinary bonded courses or inherring bond or other special courses/bond with rough dressing of soil, final dressing of earth to give level surface and camber. Al joints shall be thoroughly filled/grouted with dry sand, applied to a thickness of not less than 20mm over the surface of flooring and brushed into the joints, sqm Excess(+) Full Conversion INR
Providing and filling joint sealing compound with coarse sand and 6 percent bitumen by weight complete as per drawings and technical clause 2605 of MORT&H specifications. M Excess(+) Full Conversion INR
Providing & fixing 25 mm thick and 250 mm wide compressible fiber board in expansion joint complete as per drawing and technical clause 2605 of MORT&H specifications. M Excess(+) Full Conversion INR
Supplying, fitting and placing HYSD bar reinforcement in sub- structure complete as per drawing and Technical Specifications. mt Excess(+) Full Conversion INR
Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm. sqm Excess(+) Full Conversion INR
Supplying Direction/Diversion Plate 900x300 mm rectangular with high intensity microprismatic grade retro reflective sheeting Type IV. Nos. Excess(+) Full Conversion INR
Providing and fixing drainage spout complete as per drawing and Technical specification. Nos. Excess(+) Full Conversion INR
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 110mm o/d PVC pipe of 2.5 Kgf. /sqcm M Excess(+) Full Conversion INR
Supplying and fixing of single mould twin shank reflective road studs made out of poly carbonate/ABS moulded body and reflective panels with micro prismatic lens or lass Beeds capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values shall be as given in the detailed specifications and the product shall conform to ASTM D4280. Nos. Excess(+) Full Conversion INR
Cautionary sign board 900x900x900mm triangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 as per CSR 24.44 (ai) Nos. Excess(+) Full Conversion INR
Mandatory sign board 900mm circular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. Nos. Excess(+) Full Conversion INR
Hazard Marker sign board 300x900mm rectangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 09 and IRC 67 2012, Nos. Excess(+) Full Conversion INR
Preaparing watering and ramming surface for laying concrete, for irrigation channels horizontally. 151.25 sqm Excess(+) Full Conversion INR
Extra for laying eathwork as per specifications for compaction in 20 cm layer and dressing including cost of rolling and watering as per specifications. 238.75 cum Excess(+) Full Conversion INR
Water Arrangements. Job Excess(+) Full Conversion INR
Any other Item Nos Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.63 MB
Tendernotice_2.pdf
PDF • 0.58 MB
BOQ_325412.xls
BOQ • 0.29 MB
corrigendumchangeitem17160manuke.pdf
PDF • 1.97 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .