| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L1 | Accepted-AOC LOWEST TENDER | |
| 2 | L2₹31.9 L+₹1.6 L (5.23%)Rejected-Finance H NO 8 9 29 ASOKE NAGAR OLD GAJUWAKA VIZAG 530028 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530028 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹33.0 L+₹2.7 L (8.79%)Rejected-Finance D NO 38 22 40 NEAR LAKSHMI NARASHIMA THEATER 104 AREA VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹34.4 L+₹4.1 L (13.4%)Rejected-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹34.8 L+₹4.5 L (14.9%)Rejected-Finance NEAR NEELAMMA VEPACHETTU ASSAM GARDENS VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
19 Jun 2020, 6:00 pmClosed
GE UTILITY II VISAKHAPATNAM
GE UTILITY II 104 Area Industrial Estate Post Visakhapatnam 530007
OPERATION AND MAINTENANCE OF FRESH WATER PUMP HOUSE, CONTROLLING VALVES, WATER SUPPLY DISTRIBUTION NETWORK AND CONNECTED ITEMS IN RESIDENTIAL AREAS OF NAVAL BASE AT THE AOR OF AGE E/M NO.I OF GE (UTILITY-II) VISAKHAPATNAM
2020_MES_342720_1
8699
Open Tender
Electrical Maintenance Service
Item Rate
330 days
GE UTILITY II VISAKHAPATNAM
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE UTILITY II VISAKHAPATNAM
₹99,000
Yes
11 Jul 2020
30 May 2020
20 Jun 2020
30 May 2020
19 Jun 2020
13 Jun 2020
Amount
Operation and maintenance of fresh water pump house consisting of pump sets, LT panel boards, under ground sumps, pumping lines, OHT's at Naval Park round the clock in 3 shifts of 08 hours each including sundays and holidays complete all as specified and directed by Engineer-in -Charge.
Manpower :- One skilled Operator (FGM) per shift. Shift timings:- I st shift - 0600 Hrs to 1400 Hrs II nd shift - 1400 Hrs to 2200 Hrs III rd shift - 2200 Hrs to 0600 Hrs
Details of Equipments/ plants :- (a) 60 HP centrifugal pumpset - 02 Nos (b) 50 HP centrifugal pumpset - 02 Nos (c) Vacuum pump - 02 Nos (d) Submersible pump - 01 No (e) LT panel board - 01 No (f) 1.5 Lakh Gallons capacity UG sump - 1 No (g) 0.50 Lakh Gallons capacity UG sump - 1 No. (h) Suction and discharge valves
Note: (i)n The contractor is fully responsible for the smooth and trouble free operation and timely pumping of water. (ii) The operator shall check and monitor the pumping of water from Booster pump house (Main) to Naval Park. (iii) In case of any abnormal delay in incoming pumping, the operator shall inform the matter to concerned JE or AGE E/M for further orders. (iv) The unit rate is deemed to include the following (a) Maintaining log books, record of repairs/ replacement of perished/ unserviceable, minor adjustments, minor repairs of all accessoried cleaning up keeping of plant & surroundings area neat and clean.
(b) one emergency light and necessary tools should be available in a tool box with operator for smooth functioning of installations. (c) Minor repairs like replacement of gland ropes of the pumps & valves, cleaning / adjustments of starter contractors, replacement of cable lugs inside panel / motor terminals, cleaning and tightening of incoming / outgoing cable lugs of MCCB / relays/ starters, greasing of pump /motor bearings etc.
Operation and maintenance of water supply distribution system of Naval Park and Amzari Park including pumping main valves / Building raising Valves and confirming the water in overhead tanks etc., complete for ensuring water supply to users in 2 shifts of 08 hours each including sundays and holidays complete all as specified and directed by Engineer-in -Charge.
Manpower :- One Valve (Semi- Skilled) Operator per shift. Shift timings:- I st shift - 0600 Hrs to 1400 Hrs II nd shift - 1400 Hrs to 2200 Hrs
Labour for attending GI pipe line complaints (break downs) in buildings upto fourth storey, terrace and plain area for pipe of size 15 mm to 80 mm dia including cutting and threading of pipes as per site requirement complete all as specified and directed by Engr-in-Charge. Note: GI Pipe and fittings shall be measured and paid separately under relevent items.
Labour for attending GI pipe line complaints (break downs) in buildings fifth to eigth storey including terrace for pipe of size 20 mm to 50 mm dia including cutting and threading of pipes as per site requirement including necessary scaffolding and safety measures complete all as specified and directed by Engr-in-Charge. Note: GI Pipe and fittings shall be measured and paid separately under relevent items.
All as per SI item No.4. above but nine to twelveth storey
Supply only GI tubing medium grade of following sizes Note: The Quoted rates shall be deemed to include GI sockets and GI nipple as required at site.
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply & replace 100 mm dia GI tubes medium grade with all fittings fixed to wall and ceilings or laid in floors including necessary scaffolding complete all as specified and directed.
Supply and replacement of 25 mm dia high density polythene pipe (HDPE) of pressure rating 6 Kg/ Sqcm ,including making leak proof joints complete all as specified and directed by Engineer-in-Charge
All as per Sl. Item No.8 above but of size 40 mm dia
All as per Sl. Item No.8 above but of size 50 mm dia
Supply and replace 2000 litres capacity Rotational moulded polyethylene three layer water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position as per site requirement as specified in SSR Part I complete all as directed
All as per Sl. Item No.11 above but of 5000 litres capacity
S&F 20 mm (outer dia) 3-layer PP-R (Polypropylene random copolymer) concealed SDR 7.4 Stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings fixed to walls, ceilings etc, complete including taking down old unserviceable GI pipe all as specified and directed by Engineer-in-charge:
All as per SL item No.13 above but of size 40 mm (outer dia)
All as per SL item No.13 above but of size 50 mm (outer dia)
All as per SL item No.13 above but of size 75 mm (outer dia)
Supply and fix 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to iron pipe complete including taking down old unserviceable all as specified and directed by Engr-in-Charge.
All as per SL item No.17 above but of size 25 mm dia.
All as per SL item No.17 above but of size 40 mm dia.
All as per SL item No.17 above but of size 50 mm dia.
All as per SL item No.17 above but of size 80 mm dia.
Supply and replace PP-R (Polypropylene random copolymer) gate valve (brass insert) 25 mm dia complete all as specified and directed.
All as per SL item No.22 above but of size 40 mm (outer dia)
All as per SL item No.22 above but of size 50 mm (outer dia)
M&L for maintenance of diesel Engine connected with DG Set 320 KVA for 'B' check as per recomendation of manufacturers instructions including replacement of filters, accessories like fuel filter with ring, Air filter and ring , super bypass filter element , 'O' Ring seal, Oil filter and engine Oil complete all as specified and directed by Engr-in-charge.
All as per SL item No.25 above but 110 BHP capacity Diesel driven pump set
Supply and filling Engine oil 15 W 40 Grade Castrol CRB for topping up (including draining out old oil from Gen Set) complete all as specified and directed. Make : Servo/ Valvoline/ HPCL
Supply and replace 200 mm bore CI non return valve with by pass arrangement with necessary rubber gasket, nuts, bolts, and washers etc., complete all as specified and directed.
All as per SL item No.28 above but of size 150 mm bore
All as per SL item No.28 above but of size 100 mm bore
All as per SL item No.28 above but of size 80 mm bore
Supply and replace CI sluice valves (Raising type) PN 1.6 flanged end of size 80 mm bore for complete with iron wheel head and steel spindle including new flanged rubber joint, blts, nuts and washers etc. complete all as specified and directed by Engineer -in-charge.
All as per SL item No.32 hereinbefore but 100 mm dia
All as per SL item No.32 hereinbefore but 150 mm dia
All as per SL item No.32 hereinbefore but 200 mm dia
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth and getting out soft / loose soil for laying of cables, pipes etc, complete all as specified and directed by Engr-in- Charge.
Returning filling in, including spreading levelling watering and well ramming in layers n.exc. 25 cm thick complete all as specified and directed
Removing excavated soil to a distance n.exc. 50 m distance and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed by Engr-in- Charge.
M & L Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint. complete all as specified and as directed.
Labour only for attending break down of CI pipe pipe line bursting / cracks and including cleaning / removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes, CI / DI Collar / mechanical Joints etc as per site requirement, testing for leakages of lead joints, testing and necessary dewatering complete all as specified and directed by Engr-in-Charge, for the following sizes:- Note 1 :- The quoted rate is deemed to be include the following:- (i) Arrangement of suitable Pump sets for dewatering at the time of attending break down. (ii) Necessary labour/trade men for attending break down. (iii) Labour element required for fixing CI/DI/MS pipes, specials, fittings etc. Note 2 :- Earth work, Lead joints, Supply only CI pipes, specials, fittings will be measured and paid seperately under relevant items.
200 mm bore pipe
150 mm bore pipe
100 mm bore pipe
80 mm bore pipe
Supply only CI pipes with spigot and socket ends centrifugally cast , Class 'B' of size 200 dia.
All as per SL. Item No.41 above but of 150 mm bore
All as per SL. Item No.41 above but of 100 mm bore
All as per SL. Item No.41 above but of 80 mm bore
Supply only DI K9 water supply pipe lines of size 200 mm bore with spigot and socket ends complete
All as per SL. Item No.45 above but of 150 mm bore
All as per SL. Item No.45 above but of 100 mm bore
Supply only MS ERW pipe heavy grade pipe 200 mm bore MS pipe, 6.30 mm thick
All as per SL. Item No.48 above but of 150 mm bore 5.40 mm thick
All as per SL. Item No.48 above but of 100 mm bore 4.80 mm thick
All as per SL. Item No.48 above but of 80 mm bore 4.80 mm thick NOTE for SI No. 41 to 51: (i) Labour required for fixing of CI/DI/MS pipe is included in SL item No. 40.
Material and labour for run lead joint for spigot and socket pipes (CI/DI) and fittings of size 80 mm complete all as specified and directed by Engr-in-Charge.
All as per Sl. Item No.52 above but of size 100 mm bore.
All as per Sl. Item No.52 above but of size 150 mm bore.
All as per Sl. Item No.52 above but of size 200 mm bore.
lakshmi Engineering Works
AYYAPPA CONSTRUCTIONS
GVR CONSTRUCTIONS
Bhuvaneswari Electrical Works
M/S EVEREST INFRA
SRIESWARI ENTERPRISES
Prasad and Suresh Constructions
Sri Surya Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .