Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC | ₹3.9 L | L1 | Accepted-AOC Please see AOC uploaded |
| 2 | L2₹4.4 L+₹51,738.47 (13.3%)Rejected-AOC | ₹4.4 L+₹51,738.47 (13.3%) | L2 | Rejected-AOC Please see AOC uploaded |
| 3 | L3₹4.5 L+₹60,335.37 (15.5%)Rejected-AOC | ₹4.5 L+₹60,335.37 (15.5%) | L3 | Rejected-AOC Please see AOC uploaded |
| 4 | L4₹5.1 L+₹1.2 L (31.9%)Rejected-AOC | ₹5.1 L+₹1.2 L (31.9%) | L4 | Rejected-AOC Please see AOC uploaded |
| 5 | L5₹6.8 L+₹2.9 L (74.4%)Rejected-AOC | ₹6.8 L+₹2.9 L (74.4%) | L5 | Rejected-AOC Please see AOC uploaded |
Tender Value
₹4.9 L
EMD Value
₹9,801
Closing Date
15 Jun 2020, 3:00 pmClosed
Director Dte of Lighthouses and Lightships Vsp
Directorate of Lighthouses and Lightships, Deep Bhavan, Port Residential Area, Saligrampuram, Visakhapatnam 530024
Re-wiring of Inspection Quarters, Staff Quarters Santapalli Lighthouse
2020_DGLL_561699_1
VSP/VII(05)/13 Equip Santapalli LH Vol-III
Open Tender
Electrical Works
Works
45 days
Santapalli Lighthouse, Chintapalli(Post) Via.Poosa
EMD and Tender fee
6 documents required · 6 mandatory
₹500
Yes
Director Dte of Lighthouses and Lightships
₹9,801
Yes
Deep Bhavan Visakhapatnam
31 Aug 2020
29 May 2020
16 Jun 2020
29 May 2020
15 Jun 2020
29 May 2020
4 Jun 2020
Electrical Items :
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required 1 or 2 Module (75mm * 75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mm * 75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mm * 75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (125mm * 125mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mm * 125mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.12 Module (200mmX150mm)
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Bell push
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm Sweep.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. mm
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted\ including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 6A to 32A
Supplying and fixing following rating, double pole, 240 V, isolator in the commissioning etc. as required. existing MCB DB complete with connections, testing and Commissioning 40 A
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supply of Indoor Industrial Tube Light Battens, with LED Tube (inclusive), LED Batten with Essential 4' 22W LED tube. (refer Sl No.9 for installation)
Supply of Bulk Head Luminaries IP65/66/67 IK09/10 LED Light source (inclusive) with integrated LED source. (refer Sl No.9 for installation)
Supply of LED LAMP 12W(Base B22 12-Watt LED Bulb)dimmable Master LED Glass Bulb (refer Sl No.9 for installation)
Supply of Wall Mounting Luminaries, 7W Full Glass LED lamp B22/E27 (Non Dimmable) (refer Sl No.9 for installation)
Supply of Exhaust Fan, 230mm sweep, PVC
Supply of Ceiling Fan, Electro-phoretic lacquered/ Electroplated surface for anti-rusting, High speed fan with wider tip blade for effective air circulation with Sweep 1200mm and Hight performance even at low voltage. (refer Sl No.8 for installation)
Supply and installation of Energy Meter Box for keeping energy meter and 32 A cut outs
Supply of Bare Copper wire, 8 SWG earth wire
Labour charge for laying 8 SWG wire from Earth bit to Distribution box through pvc pipe with clamp.
Labour charge for UG cable laying and termination and digging trenches 1ft wide x 2ft depth, laying of UG Cable and covering of UG Cable with bricks and covering of the trenches (Rocky area).
Supply of UG cable 4 Sqmm 2 core copper armoured cable 1.1 KV grade XLPE Insulated (From Power house to IQ) (refer Sl.No.28 for Laying of cable)
Miscellaneous items for the purchase of screws, Bolts, Nuts & Washers, drill bits, cable ties, PVC bends, PVC tees, wire strippers, steel spring, cutting wheels, cable glands, pvc junctions boxes etc.,
Rock cutting charges for concealed wiring Due to that buildings constructed by rock stone.
Transportation charge to Santapalli LH
SRINIVASA CONSTRUCTIONS
RADIANTTECHNOLOGIES
SAI KRISHNA ASSOCIATES
M/s. D ARJUNA RAO Engineering Works
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .