Officer-in-Charge, FMU(V)
Fleet Maintenance Unit, C/o Fleet Mail Office, Naval Dockyard, Visakhapatnam
RC for undertaking repairs/maintenance of IPMS/ IMCS system fitted onboard IN Ship Jyoti
2022_NAVY_499264_1
PC/301/IPMS/IMCS JYOTI DATED 04 JAN 2022
Single
Marine Services
Buy
1095 days
Fleet Maintenance Unit, Visakhapatnam
As per RFP
4 documents required · 4 mandatory
₹0
Exempted
12 Jan 2022
4 Jan 2022
12 Jan 2022
4 Jan 2022
11 Jan 2022
4 Jan 2022
4 Jan 2022 - 11 Jan 2022
180 days
Amount
First Year
Services
TA1-Ц [TANGENT MAIN PANEL] - MCR
Carryout calibration/ health checks of all components (incl output power module, indication lamps, insulation meter and MCCBs) and carry out functional checks for satisfactory operation. Repair as necessary.
Carryout operational checks of warning and alarm messages on state of devices and networking equipment of the system. Repair as necessary.
Carryout interface check with CO1, CO1-1, CЛT1-1, CЛT1-2, YCO1-1, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
TA1-1-Ц [TANGENT RESERVE PANEL] - MCR
Carryout calibration/ health checks of all components (incl output power module, indication lamps, insulation meter and MCCBs) and carry out functional checks for satisfactory operation. Repair as necessary.
Carryout checking of warning and alarm messages on state of devices and networking equipment of the system. Repair as necessary.
Carryout interface checks with CO1, CO1-1, CЛT1-1, CЛT1-2, YCO1-1, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
CO-1 [MAIN CONTROL CONSOLE] - MCR
Carryout health status checks.
Carryout functional checks of all parameters of ITMFS in respective video frames for identification of defects.
Carryout diagnostic checks of AWS, EWS and communications lines. Repair as necessary.
Carryout diagnostic check of RS20 Commutator switch, Repair as necessary.
Ca14.rryout interface checks with CO1, CO1-1, CЛT1-1, CЛT1-2, YCO1-1, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
CO1-1 [RESERVE CONTROL CONSOLE] - MCR
Carryout health status checks.
Carryout functional checks of all parameters of ITMFS in respective video frames for identification of defects.
Carryout diagnostic checks of AWS, EWS and communications lines. Repair as necessary.
Carryout diagnostic check of RS20 Commutator switch, Repair as necessary.
Carryout interface checks with CO1, CO1-1, CЛT1-1, CЛT1-2, YCO1-1, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
CЛT1-1 [SHIPKA PANEL] - MCR
Carryout health status checks.
Carryout diagnostic checks of AWS, EWS and communications lines. Repair as necessary.
Carryout calibration/ health checks of voltage converters and output channels. Repair as necessary.
Carryout Serviceability / diagnostic checks of the following devices. Repair as necessary. (Serial a - u)
a) BMX CPS 3020
b) BMX CRA 31210
c) BMX DDI 1602
d) BMX DDI 6402К
e) BMX DDO 6402К
f) BMX АМI 0810
g) BMX АRT 0814
h) BMX NOM 200 Communication Modules
j) 140 CPS 21400 Chassis
k) 67260 Processor Modules
l) 140 NOE 77101 Communication Modules
m) 140 NOE 31200 Interface Modules
n) RS20 Commutator Switch
o) 7514U – Multiplexers
p) КТ1 Timer Relay
q) Device CЗK
r) Device OAПC
s) Device OAПC1
t) Cooling Fans
u) Thermal adjustment sensor for cooling fans
Carryout interface checks with CO1, CO1-1, CЛT1-2, YCO1-1, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
Carryout calibration and in-situ functional checks of following sensors satisfactory operation: (Serial a - f)
a) Temperature Sensors fitted on Main Engine (18 nos.)
b) Temperature Sensors others (45 nos)
c) Pressure transmitter fitted in Main Engine (04 nos.)
d) Pressure transmitter others (17 nos.)
e) Level sensor (01 no.)
f)Temperature Sensors capillary
CЛT1-2 [NAROCH PANEL] - MCR
Carryout health status checks.
Carryout operational checks of AWS, EWS and communications lines. Repair as necessary.
Carryout calibration/ health checks of voltage converters and output channels. Repair as necessary.
Carryout serviceability/ diagnostic checks of the following device. Repair as necessary. (Serial a - p)
a) BMX CPS 3020
b) BMX CRA 31210
c) BMX DDI 1602,
d) BMX DDI 6402К,
e) BMX DDO 6402К,
f) BMX АМI 0810,
g) BMX АRT 0814
h) BMX NOM 200 Communication Modules
j) 140 CPS 21400 Chassis
k) 67260 Processor Modules
l) 140 NOE 77101 Communication Modules
m) 140 NOE 31200 Interface Modules
n) RS20 Commutator Switch
o) Device YCO1-3
p) Cooling Fans (A5 and A24)
p) Thermal adjustment sensor for cooling fans
Carryout interface checks with CO1, CO1-1, CЛT1-1, YCO1-1, YCO1-2 and ЗГР 4Ц. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
Carryout calibration and in-situ functional checks of following sensors satisfactory operation: (Serial a - e)
a) Pressure Sensors (11 nos.)
b) Pressure Transmitter(03 nos.)
a) Capacitive Level Sensor (07 nos.)
b) Level Sensor (34 nos.)
e) Thermo Couple Fitted in Main Engine (07 Nos)
УСО1-1 [PRIBOY PANEL] - MCR
Carryout health status checks.
Carryout operational checks of AWS, EWS and communications lines. Repair as necessary.
Carryout calibration/ health checks of voltage converters and output channels. Repair as necessary.
Carryout serviceability/ diagnostic checks of the following device. Repair as necessary. (Serial a - j)
a) BMX CPS 3020
b) BMX DDI 1602
c) BMX DDI 6402К
d) BMX DDO 6402К
e) BMX АМI 0810
f) BMX АRT 0814
g) BMX NOM 200 Communication Modules
h) Cooling Fans
j) Thermal adjustment sensor for cooling fans
Carryout interface checks with CO1, CO1-1, CЛT1-1, CЛT1-2, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
Carryout calibration and in-situ functional checks of following sensors satisfactory operation: (Serial a - g)
a) Pressure Sensors Main Engine (13 nos)
b) Pressure Sensors Others (21 nos)
c) PressureTransmitter Main Engine (206 nos)
d) Differential Pressure Sensor Main Engine (03 nos)
e) Limit Switch (02 nos)
f) Level Sensor (30 nos)
g) Capacitive Lever Sensor (07 nos)
УСО1-2 [IZHORA PANEL] - MCR
Carryout health status checks.
Carryout operational checks of AWS, EWS and communications lines. Repair as necessary.
Carryout calibration/ health checks of voltage converters and output channels. Repair as necessary.
Carryout serviceability/ diagnostic checks of the following device. Repair as necessary. (Serial a - j)
a) BMX CPS 3020
b) BMX DDI 1602
c) BMX DDI 6402К
d) BMX DDO 6402К
e) BMX АМI 0810
f) BMX АRT 0814
g) BMX NOM 200 Communication Modules
h) Cooling Fans (A5 and A24)
j) Thermal adjustment sensor for cooling fans
Carryout serviceability/ diagnostic checks of Intelligent Relay Zelio SR3.
Carryout serviceability/ diagnostic checks of device PPM3 - Power Plant Control and Protection System. Repair as necessary.
Carryout functional checks of PPM-3 in following modes: (Serial a - e)
a) Auto Control Mode. [Automatic Start/ Stop of DGs depending on the load in accordance with predefined start up priorities.
b) Semi-Auto Control Mode: [Remote operation of Start/ Stop commands to respective DGs and Switching ON/ OFF of generator circuit-breakers.
c) Automatic Synchronization: Automatic paralleling of DGs.
d) Automatic Power Distribution: Automatic sharing of load between the DGs.
e) Switching “OFF” of Insignificant Consumers Groups: As per predefined priorities.
Carryout interface checks with CO1, CO1-1, CЛT1-1, CЛT1-2 and YCO1-1. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
UPS [UNINTERRUPTED POWER SUPPLY] - MCR
Carryout health status checks.
Carryout battery cycling test as per procedure laid down in operation manual of the UPS.
Carry out serviceability checks/ load trails of UPS as per the procedure laid down in operation manual of the UPS/ Maintops.
carry out replacement of battery below 80% capacity . New battery are to be provided by the customer.(total 128 batteries)
3TP -4LI (Grom- (M/E control device) - MCR
Carryout health status checks.
carry out dioganostic checks of AWS, EWS and communication lines. Repair as necessory.
Carryout calibration/ health checks of voltage converters and output channels. Repair as necessary.
Carryout serviceability/ diagnostic checks of the following device. Repair as necessary. (Serial a - g)
a) communication module BMXNOM 0200
b) Module BMX DDI 6402K, BMX DDO 6402K
c) Analog output Module BMX AMO 0210
d) Power Modules BMX CPS 3020
e) Processor Modules BMX NOM 2020
f) Pulse counting Module BMX EHC 0800
g) Converters MINI-PS-12-24DC/5-15DC/2
Carryout inter face Checks with 3TP-MT-MO, 3TP-1.1LI, 3TP-MT-LI,TTY, and ICS Zalive- SF. Repairs as necessory
Carryout functional checks of interface channels (Ethernet and RS-485) and associate interface unit / Controller for serviveabilitiy and optimum data transfer. Repair as necessary.
Carryout operational checks and calibration of power outputs mdules of 24VDC 5 Amp. Repair as necessary.
Carry out checks/ adjustment and calibration of all Interlocks/ warning signal of following by simulation and undertaken rectification of observed defects.
a) Control Air Fault .
b)Starting Air Fault .
c) Engine Slow Down .
d) Engine Shut Down .
e) Protection OFF.
f) EOT Fault .
g) No Battery Supply.
h) Start Fail .
j) Stop Fail.
k) Emergency Stop Fail .
Carryout calibration and in-situ functional checks of following sensors satisfactory operation:
a) Temperature cutouts - Min Engine [ Total =12 nos]
b) Pressure cutouts - Main Engine [Total =11 nos]
c) Flow Sensor -Main Engine [Total =06 nos ]
d) Limit Switches - Min Engine [Total =03 nos]
3TP-MT-UNY - MCR
Carryout health status checks .
Carry out functional checks of communication lines. Repair as necessary.
3TP-1.1U[M/E CONTROL DEVICE] - BRIDGE
Carryout health status checks.
Carryout diagnostics checks of AWS , EWS and communications lines. Repair as necessary.
Carryout calibration and in-situ functional checks of following sensors satisfactory operation: (Serial a - d)
a) Modules BMXDDI 6402K, BMXDDO 6402K
b) Communication module BMX NOM 0200
c)Power Module BMX CPS 3020
d) Processor module BMX NOM 3020
Carry out interface checks with 3TP-U , 3TP-MY-JI, and 3TP-MT-II. Repair as necessary.
3TP-MT-JI - PORT BRIDGE WING
Carryout health status checks.
[EOT] - PORT BRIDGE WING
Carry out functional checks of communication lines. Repair as necessary.
3TP-MT-JI - STBD BRIDGE WING
Carryout health status checks.
[EOT] - STBD BRIDGE WING
Carry out functional checks of communication lines. Repair as necessary.
3TP-MT-MO [EOT] - ENGINE ROOM
Carryout health status checks.
Carry out functional checks of communication lines. Repair as necessary.
RPM INDICATORS - DIFFERENT LOCATION
Carryout health status checks. Repair as necessary.
RPM FREQUENCY CONVERTORS - ENGINE ROOM
Carryout health status checks.
Carryout testing and calibration of RPM frequency convertor and indicators, as per prescribed methods .
RPM SENSORS - ENGINE ROOM
Carryout health status checks.
Carryout functional checks of the device, inspecton of pick-up heads, state of the cables entering and leaving the device for any abnormality.Repair as necessary.
Spares
ICS "Zaliv-SF
Fuse link ВП2Б-1 0.25 A
Fuse link ВП2Б-1 0.5 A
Fuse link ВГ12Б-1 1.0 A
Fuse link ВП2Б-1 2.0 A
Fuse link ВП2Б-14.0А
Fuse link ВП2Б-1 5.0 A
Fuse link ВП2Б-1 6.3 A
Resistor C2-29B-0.25-120к0м+-0.1 %-1.0-A
Resistor с2-29в-0.25-200к0м+-0.1 %-1.0-A
Contact unit LAD T2
Fan SK 3238.600 comprising:
Plug RJ45 09 45 151 1100
PlugRJ45 09 45 151 1520
Breaker E202/25g 2CDE 282 001 R1025
Automatic circuit breaker S 202 M-C 10 2CDS 272 001 R0104
Automatic circuit breaker S 202 M-C 16 2CDS 272 001 R0164
Automatic circuit breaker S 202 M-C 20 2CDS 272 001 R0204
Automatic circuit breaker S 202 M-C 6 2CDS 272 001 R0064
Automatic circuit breaker S 202 M-C 63 2CDS 272 001 R0634
Automatic circuit breaker S 202 M-C 1 2CDS 272 001 R0014
Automatic circuit breaker S 202 M-D 3 2CDS 272 001 R0031
Temperature sensor SK3110.000
Buzzer 14-810.902
Buzzer 14-810.918
Indicator 61-0000.02
Indicator 704.006.218
Indicator 704.006.518
MODBUS M4700-80
Power supply QUINT-PS/1AC/24DC/10 2866763
Cable LN 00 00 00 00000 D2.0000.0
Cable Patch Cord SCQ3-8P8C4
Cable SR2 USB01
Cable TSXCRJMD 25
CableUSB2.0 (A-B) 1.8 USB2.0-AM-BM
Memory card TSX MRP F008M
Keyboard KSMX 106 B0007-W-MC1
Terminal 280-681
Terminal 280-684
Terminal 280-901
Terminal 280-903
Terminal 281-901
Terminal 281-903
Terminal 281-907
Terminal 283-901
Terminal UDK 4-DUR 2775207
Two-level terminal 280-520
Terminal with diode 281-665/281-400
Terminal with fuse 281-611/281-417
Terminal with fuse 281-611/281-541
Terminal with breaker 282-697
Three-level terminal 280-549
Button 61-1100.0
Button 704.011.018
Switch RS20-0800M4M4SDHE
Auxiliary contact S2C-H10 2CDS 200 970 R002
Auxiliary Signalling contact S2C-S/H6R
Contactor LCI D32M7
Controller TWD LCDA 24DRF
Module 140 CPS 214 00
Module 140 NOE711 01
Module 99.02.3.000.00
Module BMX ART 0814
Module BMX DDI 1602
Module BMX DDI 6402K
Module BMX DDO 6402K
Module SR3 B262BD
Module SR3 XT101BD
Analog input module BMX AMI 0810
Discrete output module TM2 DRA 16RT
Communication module 140 CRP 312 00
Communication module BMX CRA 31210
Communication module BMX NOV 0200
Power module BMX CPS 3020
Processor module 140 CPU 672 60
LED module DL2EDB1SB
Switching element 61-8430.22
Switching element 61-8490.22
Switching element 704.911.1
Jumper 095.18
Jumper 280-402
Converter 281-402
Converter TSX CUSB 485
Temperature measuring converter MACX MCR-EX-SL-TC-I-NC 2685586
Insulation measuring and monitoring device AAL-11Q96. 220-0 k Ohm. 24 VDC
Insulation measuring and monitoring device AAL-11Q96. 380-0 k Ohm. 24 VDC
Relay 40.51.8.230.0000
Relay 40.52.9.024.0000
Relay CAD-32P7
Socket 95.05
Socket SZ 2506.100
Emergency sound signalling device A112N DC24R
Xenon emergency signalling device LI01 DC24 S G G
Xenon emergency signalling device L101 DC24 S G R
Xenon emergency signalling device LI01 DC24 S G Y
Electric power station control And protection system PPM3 DG-H2-F1-1-0-0
Insulation resistance monitoring device IR125Y-4
Insulation resistance monitoring device IR425-D4-2
Chassis 140XBP006 00
Chassis BMX XBP 0800
Printer
Pressure Sensor (GT-300C 3G4V)
Pressure Transmitter (GT-300c 3G6v)
Temperature Sensor (MB1186SJ)
RTD Tempure Sensor (MN 52E 80U)
Temperature Sensor (MN 524t125U)
Temperature Sensor (MN 524t250U)
Temperature Sensor (MB286T80U)
Temperature Sensor (MN 524t150U)
Pressure Sensor (GT-300C 3G40V)
Pressure Sensor (GT-300C 3G1.6V)
Pressure Sensor (GT-300C 3G2.5V)
Pressure Sensor (GT-300C 3G10V)
Pressure Sensor (GT-300C 3G25V)
Temperature Control Sensor (MB 286 SM)
RTD Tempure Sensor (MB 286 150U)
RTD Tempure Sensor (MB 524E 150U)
Temperature Sensor (MB286SU)
Temperature Sensor (MB640S250K-F)
Temperature Sensor (MN524S-U)
Pressure Sensor- KPS 35
Pressure Sensor-RT1
Pressure Sensor-RT5
Pressure Sensor-RT116
Pressure Sensor-RT117
Pressure Sensor-RT108
Pressure Sensor-RT101
Pressure Sensor-RT107
Pressure Sensor-RT262A
Level Sensor- A01041
Level Sensor- A01140
Flow Sensor -SO1D (A01041)
Capacitavie Level Sensor -AL C810
Capillary Sensor HMV70
Boiler Water Level Meter (Differential Pressure Transmeter) 205CD1A02A1AH2B7D4DFQ4
RCS "Grom-C
Button K02-19
Button K02-23
Button K02-27
Button K02-29
Button K02-33
Indicator И02-00
Indicator И02-01
Indicator И02-06
Indicator И17-00
Indicator И17-01
Module МНИ-008
Module МНИ-009
Module МНИ-010
Fuse Link ВП2Б-1 0.5 A
Fuse Link ВП2Б-1 2.0 A
Module M Д4-200-1.5 УХЛЗ
Segment display module MOC-112-000
Converter АЦПВТ- 14С-02И-485
Resistor C2-29B-0.25-1200м+-0 1%1.0-A
Fan SK3238.600
Plug MSTBVK 2.5/20-GF-5.08 1803138
Automatic circuit breaker S 202 M-C 10 2CDS 272 001 R0104
Automatic circuit breaker S 202 M-D 3 2CDS 272 001 R0031
Temperature sensor SK 3110.000
Dimmer DM-107
Buzzer 14-810.902
Buzzer 14-810.918
Indicator 704.006.218
Indicator 704.006.518
Power source QUINT-PS/1AC/24DC/10 2866763
Cable BMX FCW 303
Button 84-1201.7
Auxiliary contact S2C-H10 2CDS 200 970 R0002
Cover 84-9103.7
Cover BMX XEM010
Module 99.02.9.024.99
Module BMX AMD 0210
Module BMX DDI 6402K
Module BMX DDO 6402K
Module BMX EHC 0800
Communication module BMX NOM 0200
Power module BMX CPS 3020
Processor module BMX P34 2020
Switching element 84-8511.2620
Switching element 84-8511.4620
Switching element 84-8511.5620
Switching element 84-8511.9620
Direct current converter MINI-PS-12-24DC/5-15DC/2 2320018
Electro pneumatic converter 550-AHA
Relay 40.52.9.024.0000
SocketMSTB 2.5/20-STF-5.08 1778166
Socket SZ 2506.100
Chassis BMX XBP 0800
Second Year
Services
TA1-Ц [TANGENT MAIN PANEL] - MCR
Carryout calibration/ health checks of all components (incl output power module, indication lamps, insulation meter and MCCBs) and carry out functional checks for satisfactory operation. Repair as necessary.
Carryout operational checks of warning and alarm messages on state of devices and networking equipment of the system. Repair as necessary.
Carryout interface check with CO1, CO1-1, CЛT1-1, CЛT1-2, YCO1-1, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
TA1-1-Ц [TANGENT RESERVE PANEL] - MCR
Carryout calibration/ health checks of all components (incl output power module, indication lamps, insulation meter and MCCBs) and carry out functional checks for satisfactory operation. Repair as necessary.
Carryout checking of warning and alarm messages on state of devices and networking equipment of the system. Repair as necessary.
Carryout interface checks with CO1, CO1-1, CЛT1-1, CЛT1-2, YCO1-1, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
CO-1 [MAIN CONTROL CONSOLE] - MCR
Carryout health status checks.
Carryout functional checks of all parameters of ITMFS in respective video frames for identification of defects.
Carryout diagnostic checks of AWS, EWS and communications lines. Repair as necessary.
Carryout diagnostic check of RS20 Commutator switch, Repair as necessary.
Ca14.rryout interface checks with CO1, CO1-1, CЛT1-1, CЛT1-2, YCO1-1, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
CO1-1 [RESERVE CONTROL CONSOLE] - MCR
Carryout health status checks.
Carryout functional checks of all parameters of ITMFS in respective video frames for identification of defects.
Carryout diagnostic checks of AWS, EWS and communications lines. Repair as necessary.
Carryout diagnostic check of RS20 Commutator switch, Repair as necessary.
Carryout interface checks with CO1, CO1-1, CЛT1-1, CЛT1-2, YCO1-1, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
CЛT1-1 [SHIPKA PANEL] - MCR
Carryout health status checks.
Carryout diagnostic checks of AWS, EWS and communications lines. Repair as necessary.
Carryout calibration/ health checks of voltage converters and output channels. Repair as necessary.
Carryout Serviceability / diagnostic checks of the following devices. Repair as necessary. (Serial a - u)
a) BMX CPS 3020
b) BMX CRA 31210
c) BMX DDI 1602
d) BMX DDI 6402К
e) BMX DDO 6402К
f) BMX АМI 0810
g) BMX АRT 0814
h) BMX NOM 200 Communication Modules
j) 140 CPS 21400 Chassis
k) 67260 Processor Modules
l) 140 NOE 77101 Communication Modules
m) 140 NOE 31200 Interface Modules
n) RS20 Commutator Switch
o) 7514U – Multiplexers
p) КТ1 Timer Relay
q) Device CЗK
r) Device OAПC
s) Device OAПC1
t) Cooling Fans
u) Thermal adjustment sensor for cooling fans
Carryout interface checks with CO1, CO1-1, CЛT1-2, YCO1-1, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
Carryout calibration and in-situ functional checks of following sensors satisfactory operation: (Serial a - f)
a) Temperature Sensors fitted on Main Engine (18 nos.)
b) Temperature Sensors others (45 nos)
c) Pressure transmitter fitted in Main Engine (04 nos.)
d) Pressure transmitter others (17 nos.)
e) Level sensor (01 no.)
f)Temperature Sensors capillary
CЛT1-2 [NAROCH PANEL] - MCR
Carryout health status checks.
Carryout operational checks of AWS, EWS and communications lines. Repair as necessary.
Carryout calibration/ health checks of voltage converters and output channels. Repair as necessary.
Carryout serviceability/ diagnostic checks of the following device. Repair as necessary. (Serial a - p)
a) BMX CPS 3020
b) BMX CRA 31210
c) BMX DDI 1602,
d) BMX DDI 6402К,
e) BMX DDO 6402К,
f) BMX АМI 0810,
g) BMX АRT 0814
h) BMX NOM 200 Communication Modules
j) 140 CPS 21400 Chassis
k) 67260 Processor Modules
l) 140 NOE 77101 Communication Modules
m) 140 NOE 31200 Interface Modules
n) RS20 Commutator Switch
o) Device YCO1-3
p) Cooling Fans (A5 and A24)
p) Thermal adjustment sensor for cooling fans
Carryout interface checks with CO1, CO1-1, CЛT1-1, YCO1-1, YCO1-2 and ЗГР 4Ц. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
Carryout calibration and in-situ functional checks of following sensors satisfactory operation: (Serial a - e)
a) Pressure Sensors (11 nos.)
b) Pressure Transmitter(03 nos.)
a) Capacitive Level Sensor (07 nos.)
b) Level Sensor (34 nos.)
e) Thermo Couple Fitted in Main Engine (07 Nos)
УСО1-1 [PRIBOY PANEL] - MCR
Carryout health status checks.
Carryout operational checks of AWS, EWS and communications lines. Repair as necessary.
Carryout calibration/ health checks of voltage converters and output channels. Repair as necessary.
Carryout serviceability/ diagnostic checks of the following device. Repair as necessary. (Serial a - j)
a) BMX CPS 3020
b) BMX DDI 1602
c) BMX DDI 6402К
d) BMX DDO 6402К
e) BMX АМI 0810
f) BMX АRT 0814
g) BMX NOM 200 Communication Modules
h) Cooling Fans
j) Thermal adjustment sensor for cooling fans
Carryout interface checks with CO1, CO1-1, CЛT1-1, CЛT1-2, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
Carryout calibration and in-situ functional checks of following sensors satisfactory operation: (Serial a - g)
a) Pressure Sensors Main Engine (13 nos)
b) Pressure Sensors Others (21 nos)
c) PressureTransmitter Main Engine (206 nos)
d) Differential Pressure Sensor Main Engine (03 nos)
e) Limit Switch (02 nos)
f) Level Sensor (30 nos)
g) Capacitive Lever Sensor (07 nos)
УСО1-2 [IZHORA PANEL] - MCR
Carryout health status checks.
Carryout operational checks of AWS, EWS and communications lines. Repair as necessary.
Carryout calibration/ health checks of voltage converters and output channels. Repair as necessary.
Carryout serviceability/ diagnostic checks of the following device. Repair as necessary. (Serial a - j)
a) BMX CPS 3020
b) BMX DDI 1602
c) BMX DDI 6402К
d) BMX DDO 6402К
e) BMX АМI 0810
f) BMX АRT 0814
g) BMX NOM 200 Communication Modules
h) Cooling Fans (A5 and A24)
j) Thermal adjustment sensor for cooling fans
Carryout serviceability/ diagnostic checks of Intelligent Relay Zelio SR3.
Carryout serviceability/ diagnostic checks of device PPM3 - Power Plant Control and Protection System. Repair as necessary.
Carryout functional checks of PPM-3 in following modes: (Serial a - e)
a) Auto Control Mode. [Automatic Start/ Stop of DGs depending on the load in accordance with predefined start up priorities.
b) Semi-Auto Control Mode: [Remote operation of Start/ Stop commands to respective DGs and Switching ON/ OFF of generator circuit-breakers.
c) Automatic Synchronization: Automatic paralleling of DGs.
d) Automatic Power Distribution: Automatic sharing of load between the DGs.
e) Switching “OFF” of Insignificant Consumers Groups: As per predefined priorities.
Carryout interface checks with CO1, CO1-1, CЛT1-1, CЛT1-2 and YCO1-1. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
UPS [UNINTERRUPTED POWER SUPPLY] - MCR
Carryout health status checks.
Carryout battery cycling test as per procedure laid down in operation manual of the UPS.
Carry out serviceability checks/ load trails of UPS as per the procedure laid down in operation manual of the UPS/ Maintops.
carry out replacement of battery below 80% capacity . New battery are to be provided by the customer.(total 128 batteries)
3TP -4LI (Grom- (M/E control device) - MCR
Carryout health status checks.
carry out dioganostic checks of AWS, EWS and communication lines. Repair as necessory.
Carryout calibration/ health checks of voltage converters and output channels. Repair as necessary.
Carryout serviceability/ diagnostic checks of the following device. Repair as necessary. (Serial a - g)
a) communication module BMXNOM 0200
b) Module BMX DDI 6402K, BMX DDO 6402K
c) Analog output Module BMX AMO 0210
d) Power Modules BMX CPS 3020
e) Processor Modules BMX NOM 2020
f) Pulse counting Module BMX EHC 0800
g) Converters MINI-PS-12-24DC/5-15DC/2
Carryout inter face Checks with 3TP-MT-MO, 3TP-1.1LI, 3TP-MT-LI,TTY, and ICS Zalive- SF. Repairs as necessory
Carryout functional checks of interface channels (Ethernet and RS-485) and associate interface unit / Controller for serviveabilitiy and optimum data transfer. Repair as necessary.
Carryout operational checks and calibration of power outputs mdules of 24VDC 5 Amp. Repair as necessary.
Carry out checks/ adjustment and calibration of all Interlocks/ warning signal of following by simulation and undertaken rectification of observed defects.
a) Control Air Fault .
b)Starting Air Fault .
c) Engine Slow Down .
d) Engine Shut Down .
e) Protection OFF.
f) EOT Fault .
g) No Battery Supply.
h) Start Fail .
j) Stop Fail.
k) Emergency Stop Fail .
Carryout calibration and in-situ functional checks of following sensors satisfactory operation:
a) Temperature cutouts - Min Engine [ Total =12 nos]
b) Pressure cutouts - Main Engine [Total =11 nos]
c) Flow Sensor -Main Engine [Total =06 nos ]
d) Limit Switches - Min Engine [Total =03 nos]
3TP-MT-UNY - MCR
Carryout health status checks .
Carry out functional checks of communication lines. Repair as necessary.
3TP-1.1U[M/E CONTROL DEVICE] - BRIDGE
Carryout health status checks.
Carryout diagnostics checks of AWS , EWS and communications lines. Repair as necessary.
Carryout calibration and in-situ functional checks of following sensors satisfactory operation: (Serial a - d)
a) Modules BMXDDI 6402K, BMXDDO 6402K
b) Communication module BMX NOM 0200
c)Power Module BMX CPS 3020
d) Processor module BMX NOM 3020
Carry out interface checks with 3TP-U , 3TP-MY-JI, and 3TP-MT-II. Repair as necessary.
3TP-MT-JI - PORT BRIDGE WING
Carryout health status checks.
[EOT] - PORT BRIDGE WING
Carry out functional checks of communication lines. Repair as necessary.
3TP-MT-JI - STBD BRIDGE WING
Carryout health status checks.
[EOT] - STBD BRIDGE WING
Carry out functional checks of communication lines. Repair as necessary.
3TP-MT-MO [EOT] - ENGINE ROOM
Carryout health status checks.
Carry out functional checks of communication lines. Repair as necessary.
RPM INDICATORS - DIFFERENT LOCATION
Carryout health status checks. Repair as necessary.
RPM FREQUENCY CONVERTORS - ENGINE ROOM
Carryout health status checks.
Carryout testing and calibration of RPM frequency convertor and indicators, as per prescribed methods .
RPM SENSORS - ENGINE ROOM
Carryout health status checks.
Carryout functional checks of the device, inspecton of pick-up heads, state of the cables entering and leaving the device for any abnormality.Repair as necessary.
Spares
ICS "Zaliv-SF
Fuse link ВП2Б-1 0.25 A
Fuse link ВП2Б-1 0.5 A
Fuse link ВГ12Б-1 1.0 A
Fuse link ВП2Б-1 2.0 A
Fuse link ВП2Б-14.0А
Fuse link ВП2Б-1 5.0 A
Fuse link ВП2Б-1 6.3 A
Resistor C2-29B-0.25-120к0м+-0.1 %-1.0-A
Resistor с2-29в-0.25-200к0м+-0.1 %-1.0-A
Contact unit LAD T2
Fan SK 3238.600 comprising:
Plug RJ45 09 45 151 1100
PlugRJ45 09 45 151 1520
Breaker E202/25g 2CDE 282 001 R1025
Automatic circuit breaker S 202 M-C 10 2CDS 272 001 R0104
Automatic circuit breaker S 202 M-C 16 2CDS 272 001 R0164
Automatic circuit breaker S 202 M-C 20 2CDS 272 001 R0204
Automatic circuit breaker S 202 M-C 6 2CDS 272 001 R0064
Automatic circuit breaker S 202 M-C 63 2CDS 272 001 R0634
Automatic circuit breaker S 202 M-C 1 2CDS 272 001 R0014
Automatic circuit breaker S 202 M-D 3 2CDS 272 001 R0031
Temperature sensor SK3110.000
Buzzer 14-810.902
Buzzer 14-810.918
Indicator 61-0000.02
Indicator 704.006.218
Indicator 704.006.518
MODBUS M4700-80
Power supply QUINT-PS/1AC/24DC/10 2866763
Cable LN 00 00 00 00000 D2.0000.0
Cable Patch Cord SCQ3-8P8C4
Cable SR2 USB01
Cable TSXCRJMD 25
CableUSB2.0 (A-B) 1.8 USB2.0-AM-BM
Memory card TSX MRP F008M
Keyboard KSMX 106 B0007-W-MC1
Terminal 280-681
Terminal 280-684
Terminal 280-901
Terminal 280-903
Terminal 281-901
Terminal 281-903
Terminal 281-907
Terminal 283-901
Terminal UDK 4-DUR 2775207
Two-level terminal 280-520
Terminal with diode 281-665/281-400
Terminal with fuse 281-611/281-417
Terminal with fuse 281-611/281-541
Terminal with breaker 282-697
Three-level terminal 280-549
Button 61-1100.0
Button 704.011.018
Switch RS20-0800M4M4SDHE
Auxiliary contact S2C-H10 2CDS 200 970 R002
Auxiliary Signalling contact S2C-S/H6R
Contactor LCI D32M7
Controller TWD LCDA 24DRF
Module 140 CPS 214 00
Module 140 NOE711 01
Module 99.02.3.000.00
Module BMX ART 0814
Module BMX DDI 1602
Module BMX DDI 6402K
Module BMX DDO 6402K
Module SR3 B262BD
Module SR3 XT101BD
Analog input module BMX AMI 0810
Discrete output module TM2 DRA 16RT
Communication module 140 CRP 312 00
Communication module BMX CRA 31210
Communication module BMX NOV 0200
Power module BMX CPS 3020
Processor module 140 CPU 672 60
LED module DL2EDB1SB
Switching element 61-8430.22
Switching element 61-8490.22
Switching element 704.911.1
Jumper 095.18
Jumper 280-402
Converter 281-402
Converter TSX CUSB 485
Temperature measuring converter MACX MCR-EX-SL-TC-I-NC 2685586
Insulation measuring and monitoring device AAL-11Q96. 220-0 k Ohm. 24 VDC
Insulation measuring and monitoring device AAL-11Q96. 380-0 k Ohm. 24 VDC
Relay 40.51.8.230.0000
Relay 40.52.9.024.0000
Relay CAD-32P7
Socket 95.05
Socket SZ 2506.100
Emergency sound signalling device A112N DC24R
Xenon emergency signalling device LI01 DC24 S G G
Xenon emergency signalling device L101 DC24 S G R
Xenon emergency signalling device LI01 DC24 S G Y
Electric power station control And protection system PPM3 DG-H2-F1-1-0-0
Insulation resistance monitoring device IR125Y-4
Insulation resistance monitoring device IR425-D4-2
Chassis 140XBP006 00
Chassis BMX XBP 0800
Printer
Pressure Sensor (GT-300C 3G4V)
Pressure Transmitter (GT-300c 3G6v)
Temperature Sensor (MB1186SJ)
RTD Tempure Sensor (MN 52E 80U)
Temperature Sensor (MN 524t125U)
Temperature Sensor (MN 524t250U)
Temperature Sensor (MB286T80U)
Temperature Sensor (MN 524t150U)
Pressure Sensor (GT-300C 3G40V)
Pressure Sensor (GT-300C 3G1.6V)
Pressure Sensor (GT-300C 3G2.5V)
Pressure Sensor (GT-300C 3G10V)
Pressure Sensor (GT-300C 3G25V)
Temperature Control Sensor (MB 286 SM)
RTD Tempure Sensor (MB 286 150U)
RTD Tempure Sensor (MB 524E 150U)
Temperature Sensor (MB286SU)
Temperature Sensor (MB640S250K-F)
Temperature Sensor (MN524S-U)
Pressure Sensor- KPS 35
Pressure Sensor-RT1
Pressure Sensor-RT5
Pressure Sensor-RT116
Pressure Sensor-RT117
Pressure Sensor-RT108
Pressure Sensor-RT101
Pressure Sensor-RT107
Pressure Sensor-RT262A
Level Sensor- A01041
Level Sensor- A01140
Flow Sensor -SO1D (A01041)
Capacitavie Level Sensor -AL C810
Capillary Sensor HMV70
Boiler Water Level Meter (Differential Pressure Transmeter) 205CD1A02A1AH2B7D4DFQ4
RCS "Grom-C
Button K02-19
Button K02-23
Button K02-27
Button K02-29
Button K02-33
Indicator И02-00
Indicator И02-01
Indicator И02-06
Indicator И17-00
Indicator И17-01
Module МНИ-008
Module МНИ-009
Module МНИ-010
Fuse Link ВП2Б-1 0.5 A
Fuse Link ВП2Б-1 2.0 A
Module M Д4-200-1.5 УХЛЗ
Segment display module MOC-112-000
Converter АЦПВТ- 14С-02И-485
Resistor C2-29B-0.25-1200м+-0 1%1.0-A
Fan SK3238.600
Plug MSTBVK 2.5/20-GF-5.08 1803138
Automatic circuit breaker S 202 M-C 10 2CDS 272 001 R0104
Automatic circuit breaker S 202 M-D 3 2CDS 272 001 R0031
Temperature sensor SK 3110.000
Dimmer DM-107
Buzzer 14-810.902
Buzzer 14-810.918
Indicator 704.006.218
Indicator 704.006.518
Power source QUINT-PS/1AC/24DC/10 2866763
Cable BMX FCW 303
Button 84-1201.7
Auxiliary contact S2C-H10 2CDS 200 970 R0002
Cover 84-9103.7
Cover BMX XEM010
Module 99.02.9.024.99
Module BMX AMD 0210
Module BMX DDI 6402K
Module BMX DDO 6402K
Module BMX EHC 0800
Communication module BMX NOM 0200
Power module BMX CPS 3020
Processor module BMX P34 2020
Switching element 84-8511.2620
Switching element 84-8511.4620
Switching element 84-8511.5620
Switching element 84-8511.9620
Direct current converter MINI-PS-12-24DC/5-15DC/2 2320018
Electro pneumatic converter 550-AHA
Relay 40.52.9.024.0000
SocketMSTB 2.5/20-STF-5.08 1778166
Socket SZ 2506.100
Chassis BMX XBP 0800
Third Year
Services
TA1-Ц [TANGENT MAIN PANEL] - MCR
Carryout calibration/ health checks of all components (incl output power module, indication lamps, insulation meter and MCCBs) and carry out functional checks for satisfactory operation. Repair as necessary.
Carryout operational checks of warning and alarm messages on state of devices and networking equipment of the system. Repair as necessary.
Carryout interface check with CO1, CO1-1, CЛT1-1, CЛT1-2, YCO1-1, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
TA1-1-Ц [TANGENT RESERVE PANEL] - MCR
Carryout calibration/ health checks of all components (incl output power module, indication lamps, insulation meter and MCCBs) and carry out functional checks for satisfactory operation. Repair as necessary.
Carryout checking of warning and alarm messages on state of devices and networking equipment of the system. Repair as necessary.
Carryout interface checks with CO1, CO1-1, CЛT1-1, CЛT1-2, YCO1-1, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
CO-1 [MAIN CONTROL CONSOLE] - MCR
Carryout health status checks.
Carryout functional checks of all parameters of ITMFS in respective video frames for identification of defects.
Carryout diagnostic checks of AWS, EWS and communications lines. Repair as necessary.
Carryout diagnostic check of RS20 Commutator switch, Repair as necessary.
Ca14.rryout interface checks with CO1, CO1-1, CЛT1-1, CЛT1-2, YCO1-1, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
CO1-1 [RESERVE CONTROL CONSOLE] - MCR
Carryout health status checks.
Carryout functional checks of all parameters of ITMFS in respective video frames for identification of defects.
Carryout diagnostic checks of AWS, EWS and communications lines. Repair as necessary.
Carryout diagnostic check of RS20 Commutator switch, Repair as necessary.
Carryout interface checks with CO1, CO1-1, CЛT1-1, CЛT1-2, YCO1-1, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
CЛT1-1 [SHIPKA PANEL] - MCR
Carryout health status checks.
Carryout diagnostic checks of AWS, EWS and communications lines. Repair as necessary.
Carryout calibration/ health checks of voltage converters and output channels. Repair as necessary.
Carryout Serviceability / diagnostic checks of the following devices. Repair as necessary. (Serial a - u)
a) BMX CPS 3020
b) BMX CRA 31210
c) BMX DDI 1602
d) BMX DDI 6402К
e) BMX DDO 6402К
f) BMX АМI 0810
g) BMX АRT 0814
h) BMX NOM 200 Communication Modules
j) 140 CPS 21400 Chassis
k) 67260 Processor Modules
l) 140 NOE 77101 Communication Modules
m) 140 NOE 31200 Interface Modules
n) RS20 Commutator Switch
o) 7514U – Multiplexers
p) КТ1 Timer Relay
q) Device CЗK
r) Device OAПC
s) Device OAПC1
t) Cooling Fans
u) Thermal adjustment sensor for cooling fans
Carryout interface checks with CO1, CO1-1, CЛT1-2, YCO1-1, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
Carryout calibration and in-situ functional checks of following sensors satisfactory operation: (Serial a - f)
a) Temperature Sensors fitted on Main Engine (18 nos.)
b) Temperature Sensors others (45 nos)
c) Pressure transmitter fitted in Main Engine (04 nos.)
d) Pressure transmitter others (17 nos.)
e) Level sensor (01 no.)
f)Temperature Sensors capillary
CЛT1-2 [NAROCH PANEL] - MCR
Carryout health status checks.
Carryout operational checks of AWS, EWS and communications lines. Repair as necessary.
Carryout calibration/ health checks of voltage converters and output channels. Repair as necessary.
Carryout serviceability/ diagnostic checks of the following device. Repair as necessary. (Serial a - p)
a) BMX CPS 3020
b) BMX CRA 31210
c) BMX DDI 1602,
d) BMX DDI 6402К,
e) BMX DDO 6402К,
f) BMX АМI 0810,
g) BMX АRT 0814
h) BMX NOM 200 Communication Modules
j) 140 CPS 21400 Chassis
k) 67260 Processor Modules
l) 140 NOE 77101 Communication Modules
m) 140 NOE 31200 Interface Modules
n) RS20 Commutator Switch
o) Device YCO1-3
p) Cooling Fans (A5 and A24)
p) Thermal adjustment sensor for cooling fans
Carryout interface checks with CO1, CO1-1, CЛT1-1, YCO1-1, YCO1-2 and ЗГР 4Ц. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
Carryout calibration and in-situ functional checks of following sensors satisfactory operation: (Serial a - e)
a) Pressure Sensors (11 nos.)
b) Pressure Transmitter(03 nos.)
a) Capacitive Level Sensor (07 nos.)
b) Level Sensor (34 nos.)
e) Thermo Couple Fitted in Main Engine (07 Nos)
УСО1-1 [PRIBOY PANEL] - MCR
Carryout health status checks.
Carryout operational checks of AWS, EWS and communications lines. Repair as necessary.
Carryout calibration/ health checks of voltage converters and output channels. Repair as necessary.
Carryout serviceability/ diagnostic checks of the following device. Repair as necessary. (Serial a - j)
a) BMX CPS 3020
b) BMX DDI 1602
c) BMX DDI 6402К
d) BMX DDO 6402К
e) BMX АМI 0810
f) BMX АRT 0814
g) BMX NOM 200 Communication Modules
h) Cooling Fans
j) Thermal adjustment sensor for cooling fans
Carryout interface checks with CO1, CO1-1, CЛT1-1, CЛT1-2, YCO1-2, and ЗГР 4Ц. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
Carryout calibration and in-situ functional checks of following sensors satisfactory operation: (Serial a - g)
a) Pressure Sensors Main Engine (13 nos)
b) Pressure Sensors Others (21 nos)
c) PressureTransmitter Main Engine (206 nos)
d) Differential Pressure Sensor Main Engine (03 nos)
e) Limit Switch (02 nos)
f) Level Sensor (30 nos)
g) Capacitive Lever Sensor (07 nos)
УСО1-2 [IZHORA PANEL] - MCR
Carryout health status checks.
Carryout operational checks of AWS, EWS and communications lines. Repair as necessary.
Carryout calibration/ health checks of voltage converters and output channels. Repair as necessary.
Carryout serviceability/ diagnostic checks of the following device. Repair as necessary. (Serial a - j)
a) BMX CPS 3020
b) BMX DDI 1602
c) BMX DDI 6402К
d) BMX DDO 6402К
e) BMX АМI 0810
f) BMX АRT 0814
g) BMX NOM 200 Communication Modules
h) Cooling Fans (A5 and A24)
j) Thermal adjustment sensor for cooling fans
Carryout serviceability/ diagnostic checks of Intelligent Relay Zelio SR3.
Carryout serviceability/ diagnostic checks of device PPM3 - Power Plant Control and Protection System. Repair as necessary.
Carryout functional checks of PPM-3 in following modes: (Serial a - e)
a) Auto Control Mode. [Automatic Start/ Stop of DGs depending on the load in accordance with predefined start up priorities.
b) Semi-Auto Control Mode: [Remote operation of Start/ Stop commands to respective DGs and Switching ON/ OFF of generator circuit-breakers.
c) Automatic Synchronization: Automatic paralleling of DGs.
d) Automatic Power Distribution: Automatic sharing of load between the DGs.
e) Switching “OFF” of Insignificant Consumers Groups: As per predefined priorities.
Carryout interface checks with CO1, CO1-1, CЛT1-1, CЛT1-2 and YCO1-1. Repair as necessary.
Carryout functional checks of interface channels [Ethernet and RS-485] and associated interface units/ controllers for serviceability and optimum data transfer, Repair as necessary.
Carryout operational checks and calibration of power output modules of 24VDC 5 Amp. Repair as necessary.
UPS [UNINTERRUPTED POWER SUPPLY] - MCR
Carryout health status checks.
Carryout battery cycling test as per procedure laid down in operation manual of the UPS.
Carry out serviceability checks/ load trails of UPS as per the procedure laid down in operation manual of the UPS/ Maintops.
carry out replacement of battery below 80% capacity . New battery are to be provided by the customer.(total 128 batteries)
3TP -4LI (Grom- (M/E control device) - MCR
Carryout health status checks.
carry out dioganostic checks of AWS, EWS and communication lines. Repair as necessory.
Carryout calibration/ health checks of voltage converters and output channels. Repair as necessary.
Carryout serviceability/ diagnostic checks of the following device. Repair as necessary. (Serial a - g)
a) communication module BMXNOM 0200
b) Module BMX DDI 6402K, BMX DDO 6402K
c) Analog output Module BMX AMO 0210
d) Power Modules BMX CPS 3020
e) Processor Modules BMX NOM 2020
f) Pulse counting Module BMX EHC 0800
g) Converters MINI-PS-12-24DC/5-15DC/2
Carryout inter face Checks with 3TP-MT-MO, 3TP-1.1LI, 3TP-MT-LI,TTY, and ICS Zalive- SF. Repairs as necessory
Carryout functional checks of interface channels (Ethernet and RS-485) and associate interface unit / Controller for serviveabilitiy and optimum data transfer. Repair as necessary.
Carryout operational checks and calibration of power outputs mdules of 24VDC 5 Amp. Repair as necessary.
Carry out checks/ adjustment and calibration of all Interlocks/ warning signal of following by simulation and undertaken rectification of observed defects.
a) Control Air Fault .
b)Starting Air Fault .
c) Engine Slow Down .
d) Engine Shut Down .
e) Protection OFF.
f) EOT Fault .
g) No Battery Supply.
h) Start Fail .
j) Stop Fail.
k) Emergency Stop Fail .
Carryout calibration and in-situ functional checks of following sensors satisfactory operation:
a) Temperature cutouts - Min Engine [ Total =12 nos]
b) Pressure cutouts - Main Engine [Total =11 nos]
c) Flow Sensor -Main Engine [Total =06 nos ]
d) Limit Switches - Min Engine [Total =03 nos]
3TP-MT-UNY - MCR
Carryout health status checks .
Carry out functional checks of communication lines. Repair as necessary.
3TP-1.1U[M/E CONTROL DEVICE] - BRIDGE
Carryout health status checks.
Carryout diagnostics checks of AWS , EWS and communications lines. Repair as necessary.
Carryout calibration and in-situ functional checks of following sensors satisfactory operation: (Serial a - d)
a) Modules BMXDDI 6402K, BMXDDO 6402K
b) Communication module BMX NOM 0200
c)Power Module BMX CPS 3020
d) Processor module BMX NOM 3020
Carry out interface checks with 3TP-U , 3TP-MY-JI, and 3TP-MT-II. Repair as necessary.
3TP-MT-JI - PORT BRIDGE WING
Carryout health status checks.
[EOT] - PORT BRIDGE WING
Carry out functional checks of communication lines. Repair as necessary.
3TP-MT-JI - STBD BRIDGE WING
Carryout health status checks.
[EOT] - STBD BRIDGE WING
Carry out functional checks of communication lines. Repair as necessary.
3TP-MT-MO [EOT] - ENGINE ROOM
Carryout health status checks.
Carry out functional checks of communication lines. Repair as necessary.
RPM INDICATORS - DIFFERENT LOCATION
Carryout health status checks. Repair as necessary.
RPM FREQUENCY CONVERTORS - ENGINE ROOM
Carryout health status checks.
Carryout testing and calibration of RPM frequency convertor and indicators, as per prescribed methods .
RPM SENSORS - ENGINE ROOM
Carryout health status checks.
Carryout functional checks of the device, inspecton of pick-up heads, state of the cables entering and leaving the device for any abnormality.Repair as necessary.
Spares
ICS "Zaliv-SF
Fuse link ВП2Б-1 0.25 A
Fuse link ВП2Б-1 0.5 A
Fuse link ВГ12Б-1 1.0 A
Fuse link ВП2Б-1 2.0 A
Fuse link ВП2Б-14.0А
Fuse link ВП2Б-1 5.0 A
Fuse link ВП2Б-1 6.3 A
Resistor C2-29B-0.25-120к0м+-0.1 %-1.0-A
Resistor с2-29в-0.25-200к0м+-0.1 %-1.0-A
Contact unit LAD T2
Fan SK 3238.600 comprising:
Plug RJ45 09 45 151 1100
PlugRJ45 09 45 151 1520
Breaker E202/25g 2CDE 282 001 R1025
Automatic circuit breaker S 202 M-C 10 2CDS 272 001 R0104
Automatic circuit breaker S 202 M-C 16 2CDS 272 001 R0164
Automatic circuit breaker S 202 M-C 20 2CDS 272 001 R0204
Automatic circuit breaker S 202 M-C 6 2CDS 272 001 R0064
Automatic circuit breaker S 202 M-C 63 2CDS 272 001 R0634
Automatic circuit breaker S 202 M-C 1 2CDS 272 001 R0014
Automatic circuit breaker S 202 M-D 3 2CDS 272 001 R0031
Temperature sensor SK3110.000
Buzzer 14-810.902
Buzzer 14-810.918
Indicator 61-0000.02
Indicator 704.006.218
Indicator 704.006.518
MODBUS M4700-80
Power supply QUINT-PS/1AC/24DC/10 2866763
Cable LN 00 00 00 00000 D2.0000.0
Cable Patch Cord SCQ3-8P8C4
Cable SR2 USB01
Cable TSXCRJMD 25
CableUSB2.0 (A-B) 1.8 USB2.0-AM-BM
Memory card TSX MRP F008M
Keyboard KSMX 106 B0007-W-MC1
Terminal 280-681
Terminal 280-684
Terminal 280-901
Terminal 280-903
Terminal 281-901
Terminal 281-903
Terminal 281-907
Terminal 283-901
Terminal UDK 4-DUR 2775207
Two-level terminal 280-520
Terminal with diode 281-665/281-400
Terminal with fuse 281-611/281-417
Terminal with fuse 281-611/281-541
Terminal with breaker 282-697
Three-level terminal 280-549
Button 61-1100.0
Button 704.011.018
Switch RS20-0800M4M4SDHE
Auxiliary contact S2C-H10 2CDS 200 970 R002
Auxiliary Signalling contact S2C-S/H6R
Contactor LCI D32M7
Controller TWD LCDA 24DRF
Module 140 CPS 214 00
Module 140 NOE711 01
Module 99.02.3.000.00
Module BMX ART 0814
Module BMX DDI 1602
Module BMX DDI 6402K
Module BMX DDO 6402K
Module SR3 B262BD
Module SR3 XT101BD
Analog input module BMX AMI 0810
Discrete output module TM2 DRA 16RT
Communication module 140 CRP 312 00
Communication module BMX CRA 31210
Communication module BMX NOV 0200
Power module BMX CPS 3020
Processor module 140 CPU 672 60
LED module DL2EDB1SB
Switching element 61-8430.22
Switching element 61-8490.22
Switching element 704.911.1
Jumper 095.18
Jumper 280-402
Converter 281-402
Converter TSX CUSB 485
Temperature measuring converter MACX MCR-EX-SL-TC-I-NC 2685586
Insulation measuring and monitoring device AAL-11Q96. 220-0 k Ohm. 24 VDC
Insulation measuring and monitoring device AAL-11Q96. 380-0 k Ohm. 24 VDC
Relay 40.51.8.230.0000
Relay 40.52.9.024.0000
Relay CAD-32P7
Socket 95.05
Socket SZ 2506.100
Emergency sound signalling device A112N DC24R
Xenon emergency signalling device LI01 DC24 S G G
Xenon emergency signalling device L101 DC24 S G R
Xenon emergency signalling device LI01 DC24 S G Y
Electric power station control And protection system PPM3 DG-H2-F1-1-0-0
Insulation resistance monitoring device IR125Y-4
Insulation resistance monitoring device IR425-D4-2
Chassis 140XBP006 00
Chassis BMX XBP 0800
Printer
Pressure Sensor (GT-300C 3G4V)
Pressure Transmitter (GT-300c 3G6v)
Temperature Sensor (MB1186SJ)
RTD Tempure Sensor (MN 52E 80U)
Temperature Sensor (MN 524t125U)
Temperature Sensor (MN 524t250U)
Temperature Sensor (MB286T80U)
Temperature Sensor (MN 524t150U)
Pressure Sensor (GT-300C 3G40V)
Pressure Sensor (GT-300C 3G1.6V)
Pressure Sensor (GT-300C 3G2.5V)
Pressure Sensor (GT-300C 3G10V)
Pressure Sensor (GT-300C 3G25V)
Temperature Control Sensor (MB 286 SM)
RTD Tempure Sensor (MB 286 150U)
RTD Tempure Sensor (MB 524E 150U)
Temperature Sensor (MB286SU)
Temperature Sensor (MB640S250K-F)
Temperature Sensor (MN524S-U)
Pressure Sensor- KPS 35
Pressure Sensor-RT1
Pressure Sensor-RT5
Pressure Sensor-RT116
Pressure Sensor-RT117
Pressure Sensor-RT108
Pressure Sensor-RT101
Pressure Sensor-RT107
Pressure Sensor-RT262A
Level Sensor- A01041
Level Sensor- A01140
Flow Sensor -SO1D (A01041)
Capacitavie Level Sensor -AL C810
Capillary Sensor HMV70
Boiler Water Level Meter (Differential Pressure Transmeter) 205CD1A02A1AH2B7D4DFQ4
RCS "Grom-C
Button K02-19
Button K02-23
Button K02-27
Button K02-29
Button K02-33
Indicator И02-00
Indicator И02-01
Indicator И02-06
Indicator И17-00
Indicator И17-01
Module МНИ-008
Module МНИ-009
Module МНИ-010
Fuse Link ВП2Б-1 0.5 A
Fuse Link ВП2Б-1 2.0 A
Module M Д4-200-1.5 УХЛЗ
Segment display module MOC-112-000
Converter АЦПВТ- 14С-02И-485
Resistor C2-29B-0.25-1200м+-0 1%1.0-A
Fan SK3238.600
Plug MSTBVK 2.5/20-GF-5.08 1803138
Automatic circuit breaker S 202 M-C 10 2CDS 272 001 R0104
Automatic circuit breaker S 202 M-D 3 2CDS 272 001 R0031
Temperature sensor SK 3110.000
Dimmer DM-107
Buzzer 14-810.902
Buzzer 14-810.918
Indicator 704.006.218
Indicator 704.006.518
Power source QUINT-PS/1AC/24DC/10 2866763
Cable BMX FCW 303
Button 84-1201.7
Auxiliary contact S2C-H10 2CDS 200 970 R0002
Cover 84-9103.7
Cover BMX XEM010
Module 99.02.9.024.99
Module BMX AMD 0210
Module BMX DDI 6402K
Module BMX DDO 6402K
Module BMX EHC 0800
Communication module BMX NOM 0200
Power module BMX CPS 3020
Processor module BMX P34 2020
Switching element 84-8511.2620
Switching element 84-8511.4620
Switching element 84-8511.5620
Switching element 84-8511.9620
Direct current converter MINI-PS-12-24DC/5-15DC/2 2320018
Electro pneumatic converter 550-AHA
Relay 40.52.9.024.0000
SocketMSTB 2.5/20-STF-5.08 1778166
Socket SZ 2506.100
Chassis BMX XBP 0800
stage.html
html • 0.02 MB
finance_557634.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .