Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance A 183 TTC INDUSTRIAL AREA KHAIRANE MIDC THANE BELAPUR ROAD NAVI MUMBAI THANE MAHARASHTRA 400705 | THANE | MAHARASHTRA | 400705 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical Technically Unsuitable |
| 5 | Rejected-Technical | Rejected-Technical Commercially Unsuitable |
Tender Value
Refer Docs
Closing Date
16 May 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Manager SRC-Com
Hindustan Shipyard Limited Gandhigram SR Complex Visakhapatnam 530 005
Servicing of Main Switch Board and Emergency Switch Board on MV Vishva Ekta
2022_HSL_89909_1
20 / 22007 / MSB and ESB / 015 / 2022-23
Open Tender
Miscellaneous Services
Service
20 days
HSL Visakhapatnam
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
Exempted
3 Jun 2022
6 May 2022
16 May 2022
6 May 2022
16 May 2022
6 May 2022
120 days
Amount
SPARES WHERE EVER MENTIONED AS SHIP SUPPLY WILL BE SUPPLIED BY SHIP, VENDOR NEED NOT CONSIDER FOR THAT SPARES IN THEIR QUOTATION.
AMMETERS FOR THE FOLLOWING MACHINERIES TO CALIBRATE; ERRORS TO BE RECTIFIED & CERTIFICATES TO SUBMIT.
MAIN AIR COMPRESSOR : 0-150 AMP
M.E. AUX. BLOWERS : 0-450 AMP
ME L.O P/P : 0-300AMP
MAIN BALLAST P/PS : 0-500 AMP
E/R VENT FANS: 0- 80 AMP
STEERING MOTORS : 0-160 AMP
EMCY E.R. VENT FAN: 0-80AMP
WINDLASS :0-600 AMP
MOORING :0-600 AMP
M/E JCW P/PS:0-100 AMP
EMCY FIRE P/P MOTOR:0-200 AMP
HFO PURIFIER:0-40A
LO PURIFIER;0-30A
LO PURIFIER FEED PUMP:0-6A
TURNING GEAR MOTOR : 0-30 AMP
WATER MIST MOTOR : 0-150 AMP
ACCOMODATION A.C BLOWER MOTOR : 0-150AMP
ACCOMODATION A.C. COMPRESSOR MOTOR : digitel
HYDRUALIC PUMP HATCH COVER PANEL : 0-300 AMP
HFO TRANSFER PUMP:0-30A
FIRE & BILGE G.S. P/P MOTOR : 0-300 AMP
COOLING S.W. P/P MOTOR : 0-300 AMP
M.D.O TRANSFER P/P MOTOR : 0-60 AMP
L.T.C.F.W P/P MOTOR : 0-300 AMP
JACKET WATER PREHEATER MOTOR;0-15AMP
FREEFALL LIFEBOAT 0-50 AMP
F.O. SUPPLY PUMP 0-15 AMP
F.O. CIRCULATING PUMP 0-20 AMP
FEED WATER PUMP FOR BOILER 0-60 AMP
F.W.G EJECTOR PUMP 0-150 AMP
DISTILLATE PUMP 0-15 AMP
SHAFT POTENTIAL m VOLTMETER 0-50 AMP/0-250
BURNER MOTOR 0-10 AMP
A/E #2 LUBE OIL PRIMING PUMP 0-6 AMP
LO TRANSFER PUMP:0-15A
TACHOMETERS FOR MAIN ENGINE AND ALL THREE AUX.ENGINES TO BE CALIBERATED AND ERRORS TO BE RECTIFIED/ADJUSTED AND CERTIFCATION TO BE DONE FOR FOLLOWING NOS OF TACHOMETERS
a) M.E:2 NOS(IN ECR) + 4 NOS(IN BRIDGE) 150-0-150 RPM
QUOTE FOR INSTALLATION OF NEW TACHOMETERS OF EACH TYPE IN CASE THESE ARE FOUND BEYOND REPAIR.
E21058: ITEM:MAIN SWITCHBOARD AND EMERGENCY SWITCH BOARD MAKE : KTE CO. LTD BUSAN KOREA TYPE: DEAD FRONT SELF SUPPORTING; MACH. NO : M0291-09
BOTH MAIN & EMERGENCY SWITCH BOARDS TO BE THOROUGHLY CLEANED USING DRY AIR AND ELECTRIC CLEANER (CONSUMABLES VENDOR SUPPLY).
IF ANY OF THE PANEL/CIRCUIT INSULATION FOUND POOR INSULATOR TO BE REMOVED RENEWED BY SPARES( MATERIAL SHIP SUPPLY)
TO CARRY OUT SERVICING AND CALIBRATION OF FOLLOWING MSB METERS AND CERTICATE TO BE ISSUED :
a) AMMETER
b) VOLTMETER
c) WATTMETER
d) INSULATION METER
e) FREQUENCY METER
f) DUAL VOLTMETER
g)DUAL FREQUENCY METER
h)POWER FACTOR METER
TIGHTNESS OF ELECTRICAL CONNECTIONS & ALL NUTS & BOLTS IN M.S.B TO CHECK & TIGHTEN
ALL SWITCHBOARD SAFETIES TO BE TESTED AND SHOWN IN OPERATION AFTER CLEANING OF SWITCHBOARD.--REVERSE POWER TRIP;UNDERVOLTAGE; OVERCURRENT; SHORT CURCUIT;PREFERENTIAL TRIP;LOW INSULATION
ALL ALTERNATORS AUTO STARTING SYSTEM/STANDBY STARTING SYSTEM TO BE CHECKED AND REPAIRED.
ALL THREE GENERATORS PARALLEL OPERATION TO BE CHECKED IF NECESSARY AND ANY ADJUSTMENT ON AVR TO BE CORRECTED IF REQUIRED.
EMERGENCY GENERATOR AUTO OPERATION TO BE CHECKED AND RECTIFY THE SAME.
SERVICING AND CALIBRATION OF 5 NO’S AIR CICUIT BREAKERS ( FOUR OF MAIN SWITCH BOARD AND ONE IN EMERGENCY SWITCH BOARD) ONLY 03 NOS TO BE CARRIED OUT AS PER SHIP STAFF REQUIREMENT.
INSULATION OF MSB & ESB TO BE CHECKED BEFORE AND AFTER THE CLEANING TO BE RECORDED AND SUBMIT TO HSL/SS. BOTH 440 V, 220 V AND 24V DC INSULATION TO IMPROVE.
ALTERNATOR NO. 1 AND 3 ACB'S PREFERENTIAL TRIP (PT1 AND PT2) OCCURS OCCASIONALLY .SAME TO BE RECTIFIED.
BOTH MAIN AND EMERGENCY 230 V DB AND 24 V DC PANEL INSULATION RESISTANCE TO BE CHECKED IMPROVE IF LOW INSULATION RECTIFY DEFECT AND RECORD TO SUBMIT.
SRI VINAYAKA MARINE SERVICES
Goltens India Private Limited
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .