Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-Finance | ₹17.1 L | L1 | Accepted-Finance Selected |
| 2 | L2₹21.3 LAccepted-Finance | ₹21.3 L | L2 | Accepted-Finance Selected |
| 3 | L3₹21.8 LAccepted-Finance 44 DDA MARKET PUNJABI BASTI ARUNA NAGAR MAJNU KA TILLA DELHI 110054 | CENTRAL DELHI | DELHI | 110054 | ₹21.8 L | L3 | Accepted-Finance Selected |
| 4 | L4₹35.2 LAccepted-Finance GROUND FLOOR G 1154 A MANSAROVAR PARK SHAHDARA DELHI 110032 | SHAHDARA | DELHI | 110032 | ₹35.2 L | L4 | Accepted-Finance Selected |
Tender Value
₹35.6 L
EMD Value
₹71,108
Closing Date
27 Jan 2026, 12:00 pmClosed
Executive Engineer (E)
O/o EE(E) PWD EMD M-351, R.No.185, Old Sectt Delhi
RMO E and M Services at Delhi Vidhan Sabha, Old Sectt., Delhi (Sh- Repairing/ Rewiring of Light/ Fan Point and other Misc. Work).
2026_PWD_285191_1
107/2025-26/EMD M-351/EE(E)
Open Tender
Miscellaneous Services
365 days
Delhi Vidhan Sabha
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹71,108
27 Jan 2026
19 Jan 2026
27 Jan 2026
19 Jan 2026
27 Jan 2026
19 Jan 2026
Routine maintenance and attending day to day complaints of electrical installations and compound lights/ street lights/ security lights including repairing the wiring and light fixtures complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register and on online complaint management system, testing the insulation resistance, earth resistance etc. and providing assistance to the Engineer-in-charge during breakdown maintenance complete with replacement of worn-out parts (To be issued by the department on complaint basis but electrical tapes, T&P required for replacement of defective electrical parts and tools, safety equipment’s for deployed labour and stationary items such as logbooks, complaint registers, worker diary, Biometric attendance system will be provided by the contractor the rates deemed to be include in the tender nothing extra will be paid on account of these) including running maintenance & operation and general upkeep of various capacity drinking water supply pump sets along with sluice/ gate valves etc. to fill up over head water tank for timely delivery of water supply and carrying out the daily drill comprising of cleaning of pump house and maintaining log book for above installation and running maintenance & operation and general upkeep & cleaning of LT Panels alongwith allied accessories for maintaining essential power supply, as and when required, on account of failure of main electrical power supply/ load shedding including periodical checking of DG set for their proper functioning alongwith minor repair works, as and when required and recording reading in log book as and when required, keeping the entire installation on functional mode by deploying staff as per terms & conditions attached. i) Technical Assistant (Diploma/B.Tech) = 1No ii) Wireman Cum Operator = 3 Nos. iii) Khallasi = 3 Nos.
During maintenance Providing and replacement of following electrical accessories suitable for existing different type fitting/switch box etc. i/c dismantling & buyback of old existing material complete as required. (Labour already included in Item No. Part-I/01)
1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
5/6 amps, one way modular switch, ISI marked
15/16 amps, one way modular switch, ISI marked
3 pin 5/6 amps modular socket outlet, ISI marked
6 pin 15/16 amps modular socket outlet, ISI marked
Modular bell push, ISI marked
Stepped type Modular Fan regulator (2 module)
Call bell/ buzzer, single phase
6 amps. to 32 amps. ratings , SPN MCB, “C” curve, 10 KA breaking capacity
6 amps. to 32 amps. ratings , TP MCB, “C” curve, 10 KA breaking capacity
6 amps. to 32 amps. ratings , TPN MCB, “C” curve 10 KA breaking capacity
6 amps. to 32 amps. ratings , DP MCB, “C” curve 10 KA breaking capacity
Single pole, blanking plate
40 amps., 2 pole isolator
63 amps., 2 pole isolator
100 amps., 4 pole isolator
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferable mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supplying, Installation, Testing and Commissioning of 380 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd.
Supplying, Installation, Testing and Commissioning of 300 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd.
Supplying, Installation, Testing and Commissioning of 200 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd.
Supplying, Installation, Testing and Commissioning of 250 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd.
Supplying, Installation, Testing and Commissioning of 400 mm Sweep wall Fan suitable for 230 V 50 Hz Ac Supply complete with all accessories on existing wall etc. complete as required.
Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminum Body including trim .
S.I.T.C of 6-10 W LED bulkhead fitting made out of CRCA sheet duly power coated/Cast Aluminum body, confirming to IP66, suitable for operation on 240 V, 50 Hz AC Supply having power factor ≥ 0.90, complete i/c making connection, testing and commissioning etc complete as reqd. (Note:- Contractor shall submit 5 Years guarantee certificate of respective manufacturer along with the fitting).
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
S.I.T.C of following LED Post Top Lantern fitting made out of CRCA sheet, duly powder coated /Aluminium body, confirming to IP - 66, suitable for operation on 150 V to 270 V,(5500 to 6500K), 50 Hz AC Supply, having power factor ≥ 0.95, CRI > 80, Luminaries efficacy ≥ 80 lumen/watt , Driver efficiency > 85%, 10 kv surge protection, L-70 Life 50,000 burning hours. complete i/c dismentaling of existing fitting if any, connection, etc complete as reqd. (Note:- Contractor shall submit 5 Years gurantee certificate of respective manufacturer along with the fitting).
Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink\ of aluminium housing such that LED junction temperature shall not rise above 90°C).
Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
Supplying, Installation, Testing & Commissioning of SMC pole Box of size 250mm x 200mm x 105mm with hinged cover on surface/ recess/pole complete with aluminium connector strip - 2 Nos, MS Clamp - 2 Nos., 6-32amp. C series SPMCB- 1 No., having IP: 66 protection connection etc. as reqd.
Supplying, Installation, Testing & Commissioning of Oil heater of following size with 3 Heat Setting DUO Tech PTC & OFR (Black), Cord storage and rear safety cover, Frequency (hertz): AC 50 Hz. Power input : 230 V, Over heat protection and tilt over switch for safety, Thermostatic heat control, quick heating with PTC fan and castor wheels for easy mobility 3 power settings 1000/1500/2500 watts and an additional 400 watts ( Heater + Fan) etc. complete as reqd.
OFR 9 wave fin 2400 watt
Supplying, Installation, Testing & Commissioning of Blower/Heat Convector 1500 to 2000-Watt Room Heater with Over Heat Protection Meant for Spot Heating with three heating positions - 665/ 1330/2000 watts, Two fan speed,Twin turbo design for better heating Safety thermal cut out and portable etc. complete as reqd.
Supplying, Installation, Testing & Commissioning of Double road Quartz Heater 800-Watt Room Heater with Over Heat Protection Meant for Spot Heating with two heating positions, etc. complete as reqd.
Supplying, installation, testing & commissioning of following capacity water storage vertical /horizontal type geyser working on 230 +/- 10 V single phase 50 Hz Frequency, tank with altra thick super cold rolled steel plates, puff insolation, rated pressure: 8 bar, Temperature range 75 degree C, heating indicator, temperature setting: manual, power consumption: min 2 kw i/c Thermostate, Thermal cut off, mltifactional sefety valve complete with necessary accessories & flexible heavy duty pvc connection of sutiable length (2 Nos.) and 25 amp plug top etc, as reqd.
25 ltrs. Rating Minimum 4 star
Supplying & Laying of one number XLPE / PVC insulated PVC sheathed armoured aluminium conductor UG cable of 1.1 KV grade Conforming to IS 7098/1988 with upto date amendment of following size in existing pipe/duct/trench/open duct etc. as required
3 X 10 Sqmm
3.5X 35 Sqmm
3.5 X 50 Sqmm
3.5 X 70 Sqmm
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group C
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
Group C
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
3 Module (100 mmX75 mm)
6 Module (200 mmX75 mm)
8 Module (125 mmX125 mm)
12 Module (200 mmX150 mm)
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way (4 + 12), Double door
8 way (4 + 24), Double door
12 way (4 + 36), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) i) 8 way , Double door
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
For 8 way, Double door SPN MCBDB
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required
1 Run of cable
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3 X 10 sq. mm (22mm)
3½ X 35 sq. mm (32mm)
3½ X 50 sq. mm (35mm)
3½ X 70 sq. mm (38mm)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.01 MB
107DaytoDayMaintRepairingRewiringpointsothermiscwork.pdf
Tender Documents • 3.00 MB
BOQ_377264.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid