Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹10.5 L
EMD Value
₹20,964
Closing Date
27 Oct 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Construction of 10 roomed double storey Building at HS Saidpora Baramulla B.Q.O Electric work
2025_PWDJK_292356_1
NIT No.146/2025-26 Dt/16/10/2025
Open Tender
Electrical Works
Percentage
Baramulla
Please refer Tender documents.
4 documents required · 4 mandatory
₹600
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹20,964
16 Oct 2025
16 Oct 2025
28 Oct 2025
16 Oct 2025
27 Oct 2025
16 Oct 2025
Wiring for light point / exhaust fan point with (P+N) 2X1.5 sq.mm FRLS-H ( Polycab/ Havells/Finolex/ eqt make as approved by site engineer),PVC insulated copper conductor single core cable in surface / recessed Conduits (Anchor/polycab/Ravindra/equivalent make as approved by site engineer) , with 6Amp .modular switch (Anchor roma urban/legrand/SSK NV/equivalent make as approved by site engineer), modular plate, cover in front and suitable GI box (Excld. G.I Box laid earlier )etc of approved quality and make ISO/IEC Certified (quality of wire shall be approved before execution of wok by SITE In-charge Engineer strictly as required) job including cost of Circuit Wire in 2.5Sqmm Multi strand Copper wire from Switch board to D.B complete. excluding cost of Conduits
Wiring for Ceiling fan point with P+N) 2X 1.5 sq.mm FRLS-H ( Polycab/Havells/Finolex/eqt make as approved by site engineer,PVC insulated Copper conductor single core cable in surface / recessed Conduits , 1No. 6Amp .modular switch(Anchor roma urban/legrand/SSK NV/equivalent make as approved by site engineer), modular plate, and suitable GI box(Excld. G.I Box laid earlier ) , Two Module Stepped Type Electronic Fan Regulator of approved quality and make ISO/IEC Certified (wire shall be approved before execution of wok by SITE In-charge Engineer strictly as required) including cost of Circuit Wire in 2.5Sqmm Multi strand Copper wire complete
Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H ( Polycab/Havells/Finolex/eqt make as approved by site engineer)PVCInsulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Anchor/polycab/Ravindra/equivalent make as approved by site engineer) along with 1 x 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop Earthing of approved quality and ISI marked as required. With . 1NO. 16Amp .Modular switch(Anchor roma urban/legrand/SSK NV/equivalent make as approved by site engineer), Modular 1NO.3-PIN . 16 Amp. Socket , Modular plate, cover and suitable GI box (Excld. G.I Box laid earlier )etc as required .
Wiring for 6Amp Plug with(P+N+E) 3 x 2.5 sq.mm FRLS PVC ,Polycab/Havells/Finolex/eqt make as approved by site engineer) Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit along with 1 x 2.5 sq.mm FRLS, Polycab /Havells/ Finolex/ eqt make as approved by site engineer) PVC Insulated copper conductor single core cable for loop Earthing of approved quality and ISI marked as required. with ,2No.6Amp .Modular switch(Anchor roma urban/legrand/SSK NV/equivalent make as approved by site engineer), 2, 2NO. Modular 6 Amp. 5-PIN Socket ,6-8 Module Modular gride plate, cover and suitable GI box etc (Excld. G.I Box laid earlier )as required (wire shall be approved before execution of wok by SITE In-charge Engineer strictly , connections etc. as required.) complete excluding cost of Conduits
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/ Recessed medium class PVC conduit as required. (wire shall be approved before execution of wok by SITE In-charge Engineer strictly .
2X 10sq. MM+ 1 X 10 sq. MM (Phase +N+E) Power point Sub main in One runFrom Main Panel to .Distribution boards(Polycab/Havells/Finolex/eqt make )
2 X 6SQ.MM + 1 X 6. SQ.MM [Phase +N+E) For Lighting/Inverter Sub main in one run from Main Panel to Distribution board(Polycab/Havells/Finolex/eqt make)
2 X 4SQ.MM + 1 X 4. SQ.MM [Phase +N+E) For AC, Sub main in one run from Main Panel to Distribution board(Polycab/Havells/Finolex/eqt make)
Supplying and fixing of 6Amp to 32Amp Rating ,240v, *C* Curve Miniature Circuit Breaker suitable for inductive load of following poles in existing DB . Complete with connections ,testing and commissioning etc as required
SINGLE POLE (6-32Amp) Legrand /Havells or L&T /Schneider/ABB/ eq. make to be approved by EIC
Supplying and fixing following rating, Double pole, (P +N) 240 V, C* Curve MCB in the existing MCB DB complete with connections, testing and commissioning etc. as reqd.
40Amp. Legrand /Havells or L&T /Schneider/ABB/Siemens/ eq. make to be approved by EIC
63Amp. Legrand /Havells or L&T /Schneider/ABB/ Siemens/ eq. make to be approved by EIC
Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board,( Havell/ legrand/ Shinider/SSK make/ eq. make to be approved by EIC) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
6 way, Double door
4 way, Double door
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 2OMM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job
Supply installation testing and commissioning of 18 W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India authorised lab . The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips or Havel's or Wipro or Jaguar or Surya or Veto or Panasonic or H.G or LUKEER make / eq. make to be approved by EIC
Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells/Polycab/ LUKER USA / eq. make to be approved by EIC
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supply, laying, Connecting and Commissioning of 70sq mm 3.5 core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havel’s /with required size of thimbles dully crimped with hydraulic crimping tool including p/ fixing of saddles /clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench
Supply, installation, testing& Commissioning of Bulk Head Fittings of Havel's RUGBY Model HAVEL'S BULK HEAD Fittings with 12watt LED Bulb of Philips or Havel’s / eq. make to be approved by EIC
Providing , Laying of 25 mm dia./32mm dia 2mm thick PVC Unbreakable conduits including cost other accessories like bends ,Deep Junction Boxes ,Surface junctions etc complete [ FOR Sub mains & Downs, if needed at site ]
25mmdia.
Supplying, Installation, Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical fires
Supply installation testing and commissioning of Sine Wave Inverter Capacity 5 KVA 48 V, Rated Power 4800 W,Supports 04 No of batteries each 200Ah 12 V ,24 Month Warranty Safe for sensitive appliances with Sine wave out-put, Inverter should run heavy loads like AC, Geyser, Photocopiers, Auto over-load handling capacity Installation and maintenance friendly Offers high quality and reliable power back-up solution for office and homes ,MCB for protection from Input mains,Bypass switch for supplying output directly from grid in case of Home UPS fault.Noiseless Operations with the help of low harmonic distortion, Intuitive Display to easily understand status of mains availability, battery status, etc.Comprehensive protection against short-circuit, reverse polarity, battery over-charge, deep-discharge etc.Adaptive Battery charging control system technology (ABCC) ensures faster battery charging and enhances battery life by around 70%.Supports a wide battery range, i.e. Flat Plate, Tubular & VRLA (SMF).praffered make Luminous/ Microtek/Exide/ eq. make to be approved by EIC. the job also includes 4 No. trollies for housing 4 No battries and inverter.
Supplying, Installation, Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.05 MB
BOQ_942960.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .