Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹2.2 Cr
EMD Value
₹2.2 L
Closing Date
30 Oct 2026, 5:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
ACE PH DIVISION BHABANIPATANA
RAILWAY STATION ROAD PARAMANANDPUR
Construction of SubDivisional Office Building SDO JE quarter along with other ancillary work at Nuapada
2026_PHEO_143891_1
SEPHDBHPT 41 of 2026-27 Dt. 03.10.2026
Open Tender
Civil Works - Buildings
Percentage
180 days
NUAP ADA
RELEVANT DOCUMENTS AS PER DTCN
2 documents required · 2 mandatory
₹10,000
₹2.2 L
Yes
16 Oct 2026
16 Oct 2026
31 Oct 2026
16 Oct 2026
30 Oct 2026
16 Oct 2026
16 Oct 2026 - 26 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Construction of Office Building of SDO at Nuapada.
Soil testing,design, drawing construction of single storey with three storyed foundation (GF) for Non-residential Building including all cost of labour, materials, transportation etc. all complete, as per direction of Engineer-in-charge. (As per works department office Memorandum No: 1951 / 30.01.2024) Plinth area for Construction of office Building of SDO | 200 | Sqm. | 25,062 | ₹50,12,400 |
| 2 | Supplying, fitting,& fixing Vitrified tile flooring in floors treads or steps and landing forNon-residential Building including all cost of labour, materials, transportation etc. all complete, as per direction of Engineer-in-charge.(As per works department office Memorandum No: 1951 / 30.01.2024) | 230 | Sqm. | 1,065 | ₹2,44,950 |
| 3 | Supply of Elegant look 60 W (+/-10%) AIO LED Solar Street lights having extruded aluminum housing, 180Wp or more Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 78 Ah or more LiFePO4 battery (BIS certified), BMS, MPPT charge controller, PIR sensor to provide 2 days (24 hrs.) back up. The luminaire is having IP 65 protection for critical components, IK 07 and having lumen output of > 10000 lumen and having minimum lumen efficacy >160 Im/w) as per LM 79 report third party NABL lab to justify the lumen output & lumen efficacy. Lenses should be provided on the LED chip for better lighting distribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party NABL lab reports to justify the lumen efficacy, luminaire output, IK 07 and IP 65 protection. The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole. The Solar Street light and solar panel having capacity of 180 Wp or more must be designed to take the wind load at 180 KM/HR wind speed (As per wind load test report). The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales service will be provided through their toll-free base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredited laboratory. The following test reports must be submitted for the technical acceptance of the products. 1.LM 79 REPORT (Third party NABL lab only), 2. IK 07 (Report of Third party NABL lab only for any wattage of AIO solar light), 3. IP 65 (Report of Third party NABL lab only, 4. Wind load test report of AIO Street light having 180 Wp or more capacity Solar Mono Panel suitable for 180 KM/Hr wind Speed. The AIO solar street light must complies to the following: 1. EN50530- MPPT Efficiency, 2. IEC61547, 3. IEC61000-3-2 - EMC, 4. IЕC 60598-2-3,5. IEC 62109-1, (The necessary test reports of third party NABL lab against the above must be submitted for any wattage of AIO Solar street lights for acceptance of product/TDS approval prior to start of the work. All the test reports must be in the name of solar lighting company) Make- (Philips/Panasonic/Wipro/Crompton/Bajaj/Havells or equivalent). NB: The cost includes 5 years of the product in case of any defect. CMC including repair/ Maintenance/ replacement | 4 | Nos | 64,950 | ₹2,59,800 |
| 4 | Supply of 8 mtr long hot dip galvanized Octagonal pole having base dia of 155 mm and top dia of 70 mm and plate thick ness of 4 mm or more. complete with base plate and 4 nos. Type En 8 grade foundation bolts to withstand 180 KM/HR or more wind speed considering the weight & dimension of 1 nos 60 W AIO Solar light to be fitted in the pole at two different heights (One light on Pole Top and second light on the differential bracket) (Make - Bajaj/RR Ispat Nalmont/Utkarsh or equivalent) | 4 | Nos | 22,500 | ₹90,000 |
| 5 | Construction of RCC foundation by using M20gradeRCC and Fe415 grade reinforcement in the foundation by considering the SBC as 10 T per sq mtr and fixing 4 nos. EN8 grade foundation bolts in that foundation for installation of pole with solar lighten that foundation. The work shall be executed as per the instruction of EIC. | 4 | Nos | 7,500 | ₹30,000 |
| 6 | Construction of Compound Wall of 210 mtr.Length Providing, fitting and fixing of 2'.0" dia concertina Helix Coil with Y angle over the boundary to prevent unwanted intrusion inside Office Building including all cost of labour, materials, transportation etc. all complete, as per direction of Engineer-in-charge. | 345 | Mtr. | 14,425.65 | ₹49,76,849.25 |
| 7 | Construction of Approach Road of 25 mtr.Length Providing, and laying of 80mm thick factory made cement concrete interlocking paver block of M 40 grade inside Office Building Campus including all cost of labour, materials, transportation etc. all complete, as per direction of Engineer-in-charge. | 25 | Mtr. | 2,679.29 | ₹66,982.25 |
| 8 | Construction of RCC Framed Portico of 4m x4 mtr.size inside Office Building Campus including all cost of labour, materials, transportation etc. all complete, as per direction of Engineer-in-charge. | 16 | Sqm. | 10,706 | ₹1,71,296 |
| 9 | Construction of Two-Wheeler Parking of 30 Sqmtr.size inside Office Building Campus including all cost of labour, materials, transportation etc. all complete, as per direction of Engineer-in-charge. | 30 | Sqm. | 2,719 | ₹81,570 |
| 10 | Supply, Installation, Testing and Commissioning of 5KW Hybrid Solar PV Power System with Battery Storage for Office Building. | 5 | Kwp | 90,270 | ₹4,51,350 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.16 MB
BOQ_614613.xls
BOQ • 0.43 MB
DTCN.pdf
Tender Documents • 2.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .