SRI DURGA MALLESWARA SWAMY VARLA DEVASTHANAM, INDRAKEELADRI, VIJAYAWADA
VIJAYAWADA
Providing Specialized Waterproofing Treatment Works to the Roofs of Mallikarjuna Mahamandapam Building.
959894
Nit No.03/EE/2026-27, Dated:09-07-2026
OPEN - NCB
Civil Works
NTR, ANDHRA PRADESH
19 documents required · 19 mandatory
₹3,953
₹1.1 L
10 Jul 2026
10 Jul 2026
10 Jul 2026
CLEANING OF THE SURFACE : For Waterproofing treatment If the surface is sound & hard condition, the surface must be clean and sound duly removing of existing treatments clean from dirt, dust and other contaminations by power grinding wire brushing, air blower & jet water cleaning.
SPECIALISED POLYURETHANE SEALANT TREATMENT : a). Making ‘’U” Groove (width and depth of 6mm x 6mm) b). Filling of the groove with polyurethane sealant:
FIVE LAYER SYSTEM OF POLYUREA POLYURETHANE WATERPROOFING TREATMENT TO THE TERRACE Supplying & applying of Solvent Free, 100% solids, Two Component (ASTM D 16, Type V). Polyurea (0.5mm) + Polyurethane (0.7mm) + Aliphatic Coating (0.3mm) System, Non-Tar Extended, Total System Thickness of 1.5mm (excluding primer) of polyura/ polyurethane based Armstrong's -RAINPROOF PWR 690 (Formerly known as RAINPROOF PHB 660) of Armstrong Chemicals - polyurea / polyurethane based membrane water proofing system of make - PMCC/Watershield Technologies / Fosroc. The treatment system has to form a tough durable film, highly resistant to mechanical damage and totally impervious to water immersion. Product shall not emit any Volatile Organic Compounds (VOC) or Odour and will be totally environment friendly. I) SYSTEM COMPOSITION : a). Damp Tolerant, Solvent Free Penetrating Primer - Armstrong's - RAINPROOF WP(Armstrong Chemicals/PMCC/ Watershield Technologies/ Fosroc ) 0.15 mm nominal WFT as a first layer and Laying of 45 GSM fibre mesh suggested as a 2nd layer b). Solvent Free Polyurea (0.5mm) + Polyurethane (0.7mm) + Aliphatic Coating (0.3mm) = 1.5 mm Nominal DFT - Armstrong's -RAINPROOF PWR 690 (Formerly known as RAIPROOF PHB 660 ) of Armstrong Chemicals/PMCC/ Watershield Technologies /Fosroc (Total system thickness) excluding primer. c). Stripe coat of 1mm thick of Armstrong's -RAINPROOF PWR 690( Formerly known as RAIPROOF PHB 660 ) of Armstrong Chemicals/PMCC/ Watershield Technologies /Fosroc shall be applied in parapet to floor joint portions only. RAINPROOF PWR 690 of Armstrong Chemicals /PMCC/ Watershield Technologies /Fosroc suggested in two coats as a Third & Fourth layer on the 2nd layer of Fibre mesh. II). SUPPLY: Liquid coating materials will be supplied with original manufacturer's Material Test Certificate (MTC) showing residual shelf life. Material will be in original airtight, sealed drums without any damage or leak. Only approved makes shall be purchased. III). PERFORMANCE PROPERTIES : a). Adhesion (ASTM D 4541) > 380PSI, Tensile Strength of the Concrete with 90% or more break within the concrete matrix b). Tensile Strength (ASTM D 412) > 29/20 MPa c). Elongation @ Break (ASTM D 412) > 700%/>125% d). Crack Bridging 10/2.54 mm e). Hardness (ASTM D 2240) > 42/>64 Shore D f). Water Absorption (ASTM D 570, Para 7.4, Long Term Immersion) < 1.50% g). Chemical Resistance to 30%NaOH (ASTM D543,30-day immersion). Weight Gain <1.5% h). Certified Potable Water Safe as per US FDA 175.300 by CFTRI (Only for water tank, swimming pool applications). IV). APPLICATION PROCEDURE : Strictly follow manufacturer's application instructions and provide a copy in advance to Engineer In charge to ensure compliance. Application will involve cleaning surface thoroughly with high pressure water jet, drying and application of primer and topcoat by paint rollers. Ratio of the two components (Resin : Activator) must be strictly ensured as per design. Use pre-measured packaging as far as possible. Cracks will be treated with elastomeric polyurethane sealant - ROOFEXSEAL PU of Armstrong Chemicals/ PMCC /Watershield Technologies /Fosroc coat prior to coating application. V). COVERING: This type of product has very high mechanical resistance to mechanical damage as well as UV and Sunlight and protection by Screed, Tiles, etc., is not necessary. However, the coated surface may be covered with tile/ stone, etc., for aesthetic purposes and drain board/ geotextile/ soil/ grass Note : Ensure Substrate is strong enough to receive Polyurea/ Polyurethane Aliphatic coating. (VI). TOP COAТ : Supply & apply of two coats of Single component polyurethane highly elastomeric heat resistant and waterproof coating with - RAINPROOF PU 400 (Armstrong Chemicals ) diluting with 10% of water (Armstrong Chemicals / PMCC/Watershield Technologies /Fosroc) having tensile strength of 17.6 Mpa, Hardness of 60 shore D. SRI Index (ASTM C 1459-16) of Topcoat 110 & reduce rooftop surface temperature by as much as 13 °C, after sufficient surface preparation as a final & 5th layer.
Expansion Joints SURFACE PREPARATION : Prepration of the surface: For existing expansion joint treatment Chipping of the exisiting treatments over the expansion joints concrete/ brick masonry with pneumatic power chiseling equipment and until to ahcieve the hard mother concrete surface. Chipping and removing of existing bituminous mastic boad upto 25mm deep. Duly removing of debris, cleaning of the surface from dirt, dust and other foreign matters.(BMT-H.77-SSR-2025-26)
SPEICIALISED POLYSULPHIDE SEALANT TREATMENT TO THE EXPANSION JOINTS ON TERRACE : ( 25mm X 25mm ) a]. Application of one coat of Latex based styrene butadiene rubber bonding agent – ROOFBOND SBR / ZORIBOND SBR / WATERSHIELD SBR (Armstrong / PMCC / Watershield Technologies/ Fosroc) mixing with cement as per manufacturers specifications. b]. Providing and application of Acrylic Polymer modified reinstatement mortar systems with – ROOFCRETE AR Systems / ZORICRETE CMG / WATERSHIELD ARM (Armstrong / PMCC/ Watershield Technologies/ Fosroc) to finish the damaged edges of joint and making the groove. c]. Providing and fixing of masking tape on top of the joint both sides d]. Providing and fixing of Backup support material of Polyethelene foam to leave the depth of 25mm on the joint e]. Providing and application of one coat of polysulphide primer – ROOFEXSEAL PRIMER /ZORISEAL PRIMER / WATERSHIELD PRIMER ( Armstrong / PMCC / Watershield Technologies/ Fosroc) on inner edges of joint. f]. Providing and application of Two part Polysulphide sealant -- ROOFEXSEAL PS / ZORISEAL PS / WATERSHIELD PS (Armstrong / PMCC / Watershield Technologies/ Fosroc) to a width of 25mm and 25mm depth with putty knife and neat finish. g]. Removing of masking tape and providing and application of two coats of Acrylic elastomeric cementitious coating with - ROOFCOAT / ZORICOAT /MOISTSHIELD PC (Armstrong /PMCC /Watershield Technologies / Fosroc ) .
SPECIALISED LIQUID CONCENTRATED MICRONISED SCREED CONCRETE TREATMENT TO THE TERRACE : (1' Width & 8" depth on both sides of the expansion joints ) : (a). Providing and laying of acrylic polymer bonding agent - ROOFBOND PB /ZORIBOND PB / WATERSHIELD BOND PB ( Armstrong / PMCC/ Watershield Technologies / Fosroc ) mixing with cement as per manufacturers specifications. (b). On wet Condition after the bond coat application immediately, providing and laying of screed concrete at 1:2:4 ratio by using 6mm metal mixing with liquid concentrated micronised concrete treatment with – CONPROOF 500 / ZOORIBLUEPLAST (Armstrong) / WATERSHIELD BLUEPLAST / Fosroc @ 500ml Per bag of 50 Kgs cement at an average thickness of 40mm and maintain the proper slope. (c). After the screed concrete, providing and laying of cement plastering at 1:4 ratio mixing with liquid concentrated micronised concrete treatment with – CONPROOF 500 / ZOORIBLUEPLAST (Armstrong) / WATERSHIELD BLUEPLAST / Fosroc @ 500ml Per bag of 50 Kgs cement at an average thickness of 12mm with neat finish.
(5). SUPPLY AND FIXING OF ALUMINUM SHEET OVER THE EXPANSION JOINTS ON TERRACE : [a]. Supply and Fixing of 1mm thickness Aluminum Sheet to the width of (1 feet) fixing with screws fitting to cover the top side of the expansion joint treatment. [b]. After fixing the aluminum sheet sealing the edges and screw fittings with Acrylic Caulking compound with - WONDERSEAL XL / ZORISEAL XL /WATERSHIELD XL (Armstrong / PMCC / Watershield Technologies / Fosroc ).
SPECIALISED WATER PROOFING TREATMENT TO BATH ROOM / TOILETS SPECIALISED ACRYLIC POLYMER GROUTING TREATMENT TO THE BATHROOM / TOILETS : a. Drilling of holes with power drilling machine to the required depth (12 to 14mm dia holes ) b. Fixing of rubber nozzles with cement and quick setting, rapid hardening compound putty- RAPIDSTRONG QS (Armstrong) / ZORIRAPIDR (PMCC) / WATERSHIELD QK SET (Watershield Technologies) / Fosroc. c. Grouting of holes with 140 PSI grout pump mixing with Specialised Free flow, Non-shrink polymer grout additive - RAPIDSTRONG GROUT PB(Armstrong) /ZORIGROUT PB (PMCC ) / WATERSHIELD GROUT PR (Watershield Technologies) / Fosroc. d. After completion of grouting, remove the rubber nozzles e. Later, sealing of the hole with polymer cement putty - ROOFCRETE AR System (Armstrong ) / ZORICRETE CMG (PMCC ) / MOISTSHIELD CCAR (Watershield Technologies) / Fosroc
SPECIALISED WATERPROOF COATING TREATMENT WITH FOOD NEUTRAL GRADE WATER THINNABLE EPOXY TO THE BATHROOM / TOILET : (a). Cleaning of the surface from dirt, dust and other contaminations. (b). Supply and application of one coat of Water thinnable Food neutral grade epoxy waterproof coating treatment with - CONPROOF EP (Armstrong Chemicals ) / PMCC/ Watershield Technologies / Fosroc as per directions of the specifications.
SPECIALISED ACRYLIC POLYMER IMPERVIOUS COATING TREATMENT : [1]. After the one coat of epoxy coat application, providing and laying of Two component Acrylic Polymer modified reinstatement mortar systems – ROOFCRETE AR SYSTEMS /ZORICRETE CMG / MOISTSHIELD CCAR (Armstrong / PMCC/Watershield Technologies / Fosroc ) at an average thickness of 20mm with neat finish.
Water Proofing to Toilets / Bath Rooms / Wash Rooms SPECIALISED HIGH STRENGTH FIBRE REINFORCED CRYSTALLINE POLYURETHANE BASED ELASTOMERIC WATERPROOF COATING TREATMENT TO THE TERRACE : CONPROOF PFC 5 LAYER (Armstrong / PMCC/ Watershield Technologies / Fosroc ) a) Cleaning of the surface from dirt, dust and other contaminations. b) Take high power high bond PU blended penetrative crystalline single component coating - CONPROOF PFC Or Equivalent Ist layer and mix with required water, and apply asa slurry coat directly on the cleaned surface at an average coverage of 1 Sqm per Kg penetrate in to the cracks and disturbed surface to stabilize the area. c) On wet condition of the applied slurry coat place AFM 40/ 50 GSM mesh properly as a 2nd layer with overlapping of the mat 5-10 cm. And allow the treatment for drying. d) Take high power high bond polyurethane based fibre reinforced two component coating - CONPROOF PFC Or Equivalent 3rd Layer Part -1 -1 Kg with Part - 2 : 2 Kgs and mix with required water, and apply as a third layer directly on layed of fibre mesh at an average coverage of 1 Sqm per Kg mix to penetrate into the fibre mesh. e) 4th layer take high power, high bond polyurethane based crystalline two component coating –CONPROOF PFC Or Equivalent 4th Layer Part 1 - 1 Kg with Part-2 : 2 Kgs and mix with required water, and apply as a 4th layer directly on the 3rd layer at an average coverage of 1 Sqm per Kg mix.
SPECIALISED ACRYLIC POLYMER SCREED CONCRETE TREATMENT TO THE BATHROOM / TOIELTS : [a]. Application of one coat of Latex based Acrylic polymer bonding agent – ROOFBOND SBR / ZORIBOND SBR/ WATERSHIELD SBR( Armstrong/PMCC /Watershield Technologies / Fosroc) mixing with cement as per manufacturers specifications at a consumption rate of 300 Grams per Sqm area. [b]. After the bond coat application, Providing and Laying of polymer screed concrete mixing 12mm down graded metal and providing and laying of Two component Acrylic Polymer modified reinstatement mortar ystems – ROOFCRETE AR Systems /ZORICRETE CMG/ WATERSHIELD CCAR (Armstrong / PMCC/ Watershield Technologies / Fosroc) at an average thickness of 75mm with neat finish.
PROVIDING & FIXING OF OUTLET PIPES : a. Making 3" hole with breaker b. Fixing of 1 ¼" pipe PVC. c. Fixing of pipe with Two component Acrylic Polymer modified reinstatement mortar systems – ROOFCRETE AR /ZORICRETE CMG/ MOISTSHIELD CCAR (Armstrong / PMCC / Watershield Technologies / Fosroc )
SUPPLY AND APPLICATION MULTI PURPOSE HIGHLY SOLID, POLYMER MODIFIED CEMENTITIOUS TILE ADHESIVE : (1). Cleaning of the surface . (2). Laying of the tiles with multi purpose highly solid, polymer modified cementitious tile adhesive - TILEX HI -GRIP 490 / ZORITILE GRIP / WATERSHIELD TILE GRIP (Armstrong / PMCC / ( Watershield Technologies) / Fosroc
SPECIALIZED TILE JOINTS FILLING TO THE BATHROOM / TOILETS : Providing and fixing flooring with full depth jointing and pointing to the Vitrified/ Ceramic Tile flooring in specified thick for tiles of any sizes with epoxy emulsion grout/ synthetic / resin adhesive in width of 3-5 mm with Nylon spacers excluding cost of tiles.(BMT-C.34-SSR-2025-26)
Supplying and fixing of 4" (101.6mm) multi floor trap with jali - UPVC/SWR pipe fittings (Prince/Sudhakar/Kisan/Supreme or any other ISI Brand) as per site requirements with standard practice for all floors including cost and conveyance of all materials to site, labour charges ,etc., complete for finished item of work.
Supplying and fixing 110 MM dia UV Resistant UPVC SWR Plain bend 87.50 Per ISI Standards, including cost and conveyance of All materials to site.labour etc., complete for finished item of work.
Supplying and fixing 75 MM dia UV Resistant UPVC SWR Plain bend 87.50 Per ISI Standards, including cost and conveyance of All materials to site. Labour etc., complete for finished item of work.
Supplying and fixing 110 MM dia UV Resistant UPVC SWR Single TEE as per ISI standards including cost and conveyance of all materials to site, labour etc., complete for finished item of work.
Supplying and fixing 110 MM dia UV Resistant UPVC SWR Double TEE as per ISI standards including cost and conveyance of all materials to site, labour etc., complete for finished item of work.
Supplying and fixing of SWR PVC pipes (Prince/Sudhakar/Kisan/Supreme or any ISI brand) 4 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges, complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326)
SPECIALISED STRUCTURAL REPAIRS TO THE BEAMS WITH JOCKETING SYSTEM (1). SCAFFOLDING : ( 5th & 6th floor ) Providing erection and dismantling of scaffolding for Structural repairs to the Beams with Jocketing System including the cost of ropes and labour charges complete on hire basis.
CHIPPING : BEAMS Chipping with pneumatic power chiseling equipment and until to ahcieve the hard mother concrete surface for the surface which is detoriated or damage/ existing tiles or block laying. Duly removing of debris, cleaning of the surface from dirt, dust and other foreign matters & water jet cleaning. (BMT-H.68.B-SSR-2025-26)
PROVIDING SHUTTERING SUPPORTS TO THE BEAMS
SPECIALIZED ANCHORING OF SHEAR CONNECTORS WITH HIGH STRENGTH POLYESTER RESIN ANCHOR GROUT TREATMENT TO THE BEAMS : [a]. Drilling of holes with required depth. [b]. Cleaned with compressed air and water jet. [c]. Providing and anchoring of ‘L’ shaped 8mm dia shear connectors fixing with – High strength, Polyester Resin Anchor grout compound –RAPIDSTRONG GROUT AG / ZORIFIX / WATERSHIELD AG ( Armstrong / PMCC/Watershield Technologies/ Fosroc) which produces an compressive strength of 75 N/mm2 and to resist against fresh and salt water.
SUPPLY OF STEEL REINFORCEMENT BARS
FABRICATION OF STEEL REINFORCEMENT : [a]. Labour charges for FABRICATION OF STEEL REINFORCEMENT and placed in Position and tack welded to the shear connectors.
SPECIALISED ZICH RICH PRIMER COATING TREATMENT TO THE EXPOSED REINFORCEMENT BARS : a). Cleaning of the surface from dirt, dust and other contaminations. b). Removing of loose scales of corrosion and cleaning of the surface with emery paper and wire brushes. c). Application of one coat of zinch rich primer coating -ALSTRONG ZP 777 /ZORIGUARD ZP / WATERSHIELD ZP (Armstrong / PMCC/Watershield Technologies/ Fosroc) to the exposed reinforcement bars.
SPECIALISED EPOXY BONDING AGENT TREATMENT TO THE BEAMS : a). Applying one coat of Epoxy Bonding agent as a bond coat with – - ROOFBOND EP / ZORIBOND EP / WATERSHIELD EP (Armstrong / PMCC/Watershield Technologies/ Fosroc) mixing with epoxy resin and hardener as per manufacturers specification, prior to concreting.
SPECIALISED EPOXY BONDING AGENT TREATMENT TO THE BEAMS : a). Applying one coat of Epoxy Bonding agent as a bond coat with – - ROOFBOND EP / ZORIBOND EP / WATERSHIELD EP (Armstrong / PMCC/Watershield Technologies/ Fosroc) mixing with epoxy resin and hardener as per manufacturers specification, prior to concreting.
STRUCTURAL EPOXY GROUTING TREATMENT TO THE BEAMS : Structural strengthening with Epoxy Injection Grout: Providing and grouting with Two component low viscous moisture insensitive Epoxy Injection Grout with - (RAPIDSTRONG GROUT EP of Armstrong Chemicals / PMCC / Watershield Technologies / Fosroc ) to Strengthen the structure at concrete cracks. The material having mixing ratio of 1:0.5 {Base: Hardener) by weight at the rate of 0.50 kgs., per nozzle which gives compressive strength of 70N/mm2 in 7 days as per BS6319 part 2- flexural strength of 30N/mm2 in 7 days as per BS6319 part-3- Tensile strength of 15N/mm2 in 7 days as per BS6319 part 7 epoxy resin based injection grout meets the requirement of BS 6319 & ASTM C 861. the finished cost to include surface preparation fixing of non-return valve injection packers at concrete cracks seal the nozzles with instant leak plug 0.2 kg/nozzle. all the application procedure shall be as per the direction of the Engineer-in-charge.
STRUCTURAL REPAIRS TO THE CEILING SCAFFOLDING : Scaffolding on hire charges basis for “Structural repairs to the necessary area”
SPECIALISED ACRYLIC POLYMER MODIFIED REINSTATEMENT MORTAR PLASTERING TO THE CEILING : a). Chipping of existing deteriorated , loose particles of concrete. b). Removing of loose particles. c). Cleaning of the surface from dirt, dust and other contaminations. d). Application of one coat of zinch rich primer coating - ALSTRONG ZP 777 / ZORIGUARD ZP / WATERSHIELD ZP / Fosroc (Armstrong / PMCC / Watershield Technologies/ Fosroc). e). Application of one coat of Latex based acrylic polymer bonding agent - ROOFBOND SBR / ZORIBOND SBR / WATERSHIELD SBR (Armstrong/PMCC/Watershield Technologies/ Fosroc ) mixing with cement as per manufacturers specifications. f). After the bond coat application, Providing and laying of polymer screed concrete - ROOFCRETE AR SYSTEMS /ZORICRETE CMG /MOISTSHIELD CCAR (Armstrong / PMCC/ Watershield Technologies/ Fosroc) at an average thickness of 40mm. g). After the screed concrete treatment, Providing and laying of polymer cement mortar plastering - ROOFCRETE AR SYSTEMS /ZORICRETE CMG /MOISTSHIELD CCAR (Armstrong / PMCC/ Watersshield Technologies/ Fosroc ) at an average thickness of 12mm with neat finish. g). Immediately after mortar application, Providing and applying one coat of concrete curing agent - ROOFEXCURE WB / ZORICURE WB / WATERSHIELD WB (Armstrong /PMCC/Watershield Technologies / Fosroc ).
STRUCTURAL EPOXY GROUTING TREATMENT TO THE CEILING : Structural strengthening with Epoxy Injection Grout: Providing and grouting with Two component low viscous moisture insensitive Epoxy Injection Grout with - (RAPIDSTRONG GROUT EP of Armstrong Chemicals / PMCC / Watershield Technologies / Fosroc ) to Strengthen the structure at concrete cracks. The material having mixing ratio of 1:0.5 {Base: Hardener) by weight at the rate of 0.50 kgs., per nozzle which gives compressive strength of 70N/mm2 in 7 days as per BS6319 part 2- flexural strength of 30N/mm2 in 7 days as per BS6319 part-3- Tensile strength of 15N/mm2 in 7 days as per BS6319 part 7 epoxy resin based injection grout meets the requirement of BS 6319 & ASTM C 861. the finished cost to include surface preparation fixing of non-return valve injection packers at concrete cracks seal the nozzles with instant leak plug 0.2 kg/nozzle. all the application procedure shall be as per the direction of the Engineer in charge.
WATERPROOFING TREATMENT TO THE BALCONIES SPECIALISED WATERPROOF COATING TREATMENT WITH FOOD NEUTRAL GRADE WATER THINNABLE EPOXY TO THE BALCONY AREA : (a). Cleaning of the surface from dirt, dust and other contaminations. (b). Supply and application of one coat of Water thinnable Food neutral grade epoxy waterproof coating treatment with - CONPROOF EP (Armstrong Chemicals ) / PMCC/ Watershield Technologies / Fosroc as per directions of the specifications.
SPECIALISED ACRYLIC POLYMER SCREED CONCRETE TREATMENT TO THE BALCONY : [a]. Application of one coat of Latex based Acrylic polymer bonding agent – ROOFBOND SBR / ZORIBOND SBR/ WATERSHIELD SBR( Armstrong/PMCC /Watershield Technologies / Fosroc) mixing with cement as per manufacturers specifications at a consumption rate of 300 Grams per Sqm area. [b]. After the bond coat application, Providing and Laying of polymer screed concrete mixing 12mm down graded metal and providing and laying of Two component Acrylic Polymer modified reinstatement mortar ystems – ROOFCRETE AR Systems /ZORICRETE CMG/ WATERSHIELD CCAR (Armstrong / PMCC/ Watershield Technologies / Fosroc) at an average thickness of 75mm with neat finish.
Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges ,etc., complete (Wash room Flooring)
Conveyance of debris to a lead of 14km including all the labour charges , Complete for finished item of work
Providing dadooing to walls with Supply of screen printed glazed full body porcelain wall tiles of size 300 x600 mm with any type of design texturesuch as marble finish, wooden,bamboo,stone finishes etc.,scratch less,stainfree and thickness between 6-8 mm 1stquality conforming to IS:13711,IS:13712,IS:13630 (Parts1to15) of any colour and finish in all shades and designs as approved by the Engineer-in-charge set over base coat of CM(1:3) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete excluding seigniorage charges etc., complete for finished item of work. Ground Floor.
Providing dadooing to walls with Supply of screen printed glazed full body porcelain wall tiles of size 300 x600 mm with any type of design texturesuch as marble finish, wooden,bamboo,stone finishes etc.,scratch less,stainfree and thickness between 6-8 mm 1stquality conforming to IS:13711,IS:13712,IS:13630 (Parts1to15) of any colour and finish in all shades and designs as approved by the Engineer-in-charge set over base coat of CM(1:3) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete excluding seigniorage charges etc., complete for finished item of work. First Floor.
Providing dadooing to walls with Supply of screen printed glazed full body porcelain wall tiles of size 300 x600 mm with any type of design texturesuch as marble finish, wooden,bamboo,stone finishes etc.,scratch less,stainfree and thickness between 6-8 mm 1stquality conforming to IS:13711,IS:13712,IS:13630 (Parts1to15) of any colour and finish in all shades and designs as approved by the Engineer-in-charge set over base coat of CM(1:3) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete excluding seigniorage charges etc., complete for finished item of work. 2nd Floor.
Providing dadooing to walls with Supply of screen printed glazed full body porcelain wall tiles of size 300 x600 mm with any type of design texturesuch as marble finish, wooden,bamboo,stone finishes etc.,scratch less,stainfree and thickness between 6-8 mm 1stquality conforming to IS:13711,IS:13712,IS:13630 (Parts1to15) of any colour and finish in all shades and designs as approved by the Engineer-in-charge set over base coat of CM(1:3) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete excluding seigniorage charges etc., complete for finished item of work. 3rd Floor.
Providing dadooing to walls with Supply of screen printed glazed full body porcelain wall tiles of size 300 x600 mm with any type of design texturesuch as marble finish, wooden,bamboo,stone finishes etc.,scratch less,stainfree and thickness between 6-8 mm 1stquality conforming to IS:13711,IS:13712,IS:13630 (Parts1to15) of any colour and finish in all shades and designs as approved by the Engineer-in-charge set over base coat of CM(1:3) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete excluding seigniorage charges etc., complete for finished item of work. 4th Floor.
Providing dadooing to walls with Supply of screen printed glazed full body porcelain wall tiles of size 300 x600 mm with any type of design texturesuch as marble finish, wooden,bamboo,stone finishes etc.,scratch less,stainfree and thickness between 6-8 mm 1stquality conforming to IS:13711,IS:13712,IS:13630 (Parts1to15) of any colour and finish in all shades and designs as approved by the Engineer-in-charge set over base coat of CM(1:3) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete excluding seigniorage charges etc., complete for finished item of work. 5th Floor.
Providing dadooing to walls with Supply of screen printed glazed full body porcelain wall tiles of size 300 x600 mm with any type of design texturesuch as marble finish, wooden,bamboo,stone finishes etc.,scratch less,stainfree and thickness between 6-8 mm 1stquality conforming to IS:13711,IS:13712,IS:13630 (Parts1to15) of any colour and finish in all shades and designs as approved by the Engineer-in-charge set over base coat of CM(1:3) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete excluding seigniorage charges etc., complete for finished item of work. 6th Floor.
Providing dadooing to walls with Supply of screen printed glazed full body porcelain wall tiles of size 300 x600 mm with any type of design texturesuch as marble finish, wooden,bamboo,stone finishes etc.,scratch less,stainfree and thickness between 6-8 mm 1stquality conforming to IS:13711,IS:13712,IS:13630 (Parts1to15) of any colour and finish in all shades and designs as approved by the Engineer-in-charge set over base coat of CM(1:3) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete excluding seigniorage charges etc., complete for finished item of work. 7th Floor.
Flooring with Non-skid red or white full body Ceramic floor tiles of Size 300 mm x 300mm and thickness between 7-8 mm and 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts1to15) of any colour and finish in all shades and designs 7.30mm thick , 1st quality and of size as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand , water and tiles etc., and complete for finished item of work. (APSS No.701 & 707) Ground floor
Flooring with Non-skid red or white full body Ceramic floor tiles of Size 300 mm x 300mm and thickness between 7-8 mm and 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts1to15) of any colour and finish in all shades and designs 7.30mm thick , 1st quality and of size as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand , water and tiles etc., and complete for finished item of work. (APSS No.701 & 707) 1st floor
Flooring with Non-skid red or white full body Ceramic floor tiles of Size 300 mm x 300mm and thickness between 7-8 mm and 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts1to15) of any colour and finish in all shades and designs 7.30mm thick , 1st quality and of size as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand , water and tiles etc., and complete for finished item of work. (APSS No.701 & 707) 2nd floor
Flooring with Non-skid red or white full body Ceramic floor tiles of Size 300 mm x 300mm and thickness between 7-8 mm and 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts1to15) of any colour and finish in all shades and designs 7.30mm thick , 1st quality and of size as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand , water and tiles etc., and complete for finished item of work. (APSS No.701 & 707) 3rd floor
Flooring with Non-skid red or white full body Ceramic floor tiles of Size 300 mm x 300mm and thickness between 7-8 mm and 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts1to15) of any colour and finish in all shades and designs 7.30mm thick , 1st quality and of size as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand , water and tiles etc., and complete for finished item of work. (APSS No.701 & 707) 4th floor
Flooring with Non-skid red or white full body Ceramic floor tiles of Size 300 mm x 300mm and thickness between 7-8 mm and 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts1to15) of any colour and finish in all shades and designs 7.30mm thick , 1st quality and of size as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand , water and tiles etc., and complete for finished item of work. (APSS No.701 & 707) 5th floor
Flooring with Non-skid red or white full body Ceramic floor tiles of Size 300 mm x 300mm and thickness between 7-8 mm and 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts1to15) of any colour and finish in all shades and designs 7.30mm thick , 1st quality and of size as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand , water and tiles etc., and complete for finished item of work. (APSS No.701 & 707) 6th floor
Flooring with Non-skid red or white full body Ceramic floor tiles of Size 300 mm x 300mm and thickness between 7-8 mm and 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts1to15) of any colour and finish in all shades and designs 7.30mm thick , 1st quality and of size as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand , water and tiles etc., and complete for finished item of work. (APSS No.701 & 707) 7th floor
Supply and Fixing of Premium make CPVC Pipes and Fittings to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" ton 2" SDR 11 and SDR 13.5 pipes are made from idential CPVC compounds having the same physicalProperties for Hot and Cold Water (IS 15778:2007)(SSR-2025-26-MAT-02319)
Supply, installation, testing and commissioning of 25mm dia Gate valve. Makes: As per list of recommended brands.(MAT 04485-SSR-2025-26)
Supplying and fixing of SWR PVC pipes (Prince/Sudhakar/Kisan/Supreme or any ISI brand) 4 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges, complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326) 110mm dia
Supplying and fixing of SWR PVC pipes (Prince/Sudhakar/Kisan/Supreme or any ISI brand) 4 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges, complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326) 75mm dia
Supplying and fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 of size 550mm x 400mm with 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/Senior/Nice or equivalent complete with standard CI brackets including wooden blocks ,1 No.12.70mm PVC connection with brass union nuts CP coated , 1 No.12.70mm NP bib tap 400 gms Seiko or equivalent , 31.75mm dia. PVC flexible waste pipe 914.4mm length of 1st quality including cost and conveyance of all materials to site, labour charges , for finished item of work
Supplying and fixing European Water Closet of 1st quality conforming to IS:2556-Part-2-1973 of Hindustan / Neycer or Parryware make white glazed with 'S' trap,supplying and fixing best Indian make plastic seat and lid for European water closets with rubber or plastic Buffers as per IS 2548-1996 and 10 litres capacity single flush PVC low level cistern Parryware or equivalent with internal components and fixed using required size of nails and screws, 12mm PVC connections with brass union nuts CP coated including cost and conveyance of all materials to site,etc., complete for finished item of work for all floors.
a)S & F 12.7 mm copper ball cock ith PVC ball Indian make ISI mark including labour charges.(MAT-01844)(LAB-00194)
Constructing 904.0 mm (3’0”) dia brick masonry inspection chamber as per IS - 4111: Part-1:1986 with cement mortar (1:6) prop using 2nd Class Clay Bricks of 225 mm thick from approved source having a minimum crushing strength of 5 N/sq.mm including plastering with cement mortar 1:3 prop; ½” thick both inside and outside fitted with 20” dia RCC manhole covers and frames including excavating pits up to a depth of 904 mm (3'-0") in all sorts of soils (exculding rock) and laying cement conrete (1:4:8) 150 mm thick using 40 mm HBG Metal and P.C.C. 1:2:4 benching and channel 100 mm thick as per Standard specification and including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, cost of seigniorage charges on all materials and all incidental and operational, labour charges like mixing cement mortar, constructing masonry, lift charges, curing , etc., complete for finished item of work as per Standard specification.
Supplying and fixing of 19.04mm dia , 609.6mm long aluminium anodized towel rods with brackets and aluminium screws including cost and conveyance of all materials, labour charges , for finished item of work.
Hire charges for Temporary illumination, consisting of 6.2 strip lights (navar patta) complete with 1000 Nos required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.(For 1st to 12th day)
Hire charges for Temporary illumination, consisting of white/colour series light 6.2v complete with 1000 Nos. with required wire leads duly erected and dismantled with scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer incharge. (For 1st to 12th day)
Hire charges for Temporary illumination, consisting of 8mm LED colour series light with holders, bulbs, with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge. (For 1st day)
Hire charges for Temporary illumination, consisting of 8mm LED colour series light with holders, bulbs, with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.(2nd and 3rd day)
Hire charges for Temporary illumination, consisting of 8mm LED colour series light with holders, bulbs, with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.(For 4th to 12th day)
Hire charges for Temporary illumination, consisting of 8mm LED colour series light with holders, bulbs, with required wire leads duly erected and dismantled with scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.(For 1st day)
Hire charges for Temporary illumination, consisting of 8mm LED colour series light with holders, bulbs, with required wire leads duly erected and dismantled with scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.(2nd and 3rd day)
Hire charges for Temporary illumination, consisting of 8mm LED colour series light with holders, bulbs, with required wire leads duly erected and dismantled with scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.(For 4th to 12th day)
Hire charges for Temporary illumination, consisting of RGB (Patty Type) color changing light complete with 1000 Nos. with required wire leads ,Diodes, Control boards,SMPS,Programee chips etc.,duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.(For 1st day)
Hire charges for Temporary illumination, consisting of RGB (Patty Type) color changing light complete with 1000 Nos. with required wire leads ,Diodes, Control boards,SMPS,Programee chips etc.,duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge(.For 2nd and 3rd day)
Hire charges for Temporary illumination, consisting of RGB (Patty Type) color changing light complete with 1000 Nos. with required wire leads ,Diodes, Control boards,SMPS,Programee chips etc.,duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge(For 4th to 12th day)
Hire charges for Temporary illumination, Design Boards consisting of white / colour LED lights with rotating effect on 2mm Sunglass Sheet complete. with required wire leads duly erected and dismantled with scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge..(For 1st day)
Hire charges for Temporary illumination, Design Boards consisting of white / colour LED lights with rotating effect on 2mm Sunglass Sheet complete. with required wire leads duly erected and dismantled with scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge(For 2nd and 3rd day)
Hire charges for Temporary illumination, Design Boards consisting of white / colour LED lights with rotating effect on 2mm Sunglass Sheet complete. with required wire leads duly erected and dismantled with scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.(For 4th to 12th day)
Hire charges for Temporary illumination, consisting of tube light with patti type 4'-40W complete with required wire leads, ELCB duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.(For 1st to12th day)
Hire charges for Temporary illumination, consisting of 18W/20W, 1200mm length LED batten tube light complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc..complete for 12 days as directed by Engineer in charge.(For 1st day)
Hire charges for Temporary illumination, consisting of 18W/20W, 1200mm length LED batten tube light complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc..complete for 12 days as directed by Engineer in charge.(For 2nd and 3rd day)
Hire charges for Temporary illumination, consisting of 18W/20W, 1200mm length LED batten tube light complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc..complete for 12 days as directed by Engineer in charge.(For 4th to 12th day)
Hire charges for Temporary illumination, consisting of flood light 400W metal halide fitting with lamp complete with required wire leads, ELCB duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.(For 1st day)
Hire charges for Temporary illumination, consisting of flood light 400W metal halide fitting with lamp complete with required wire leads, ELCB duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.(2nd and 3rd day)
Hire charges for Temporary illumination, consisting of flood light 400W metal halide fitting with lamp complete with required wire leads, ELCB duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge..(For 4th to 12th day)
Hire charges for Temporary illumination, consisting of 100W LED flood light complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.( For 1st day)
Hire charges for Temporary illumination, consisting of 100W LED flood light complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.. (For 2nd and 3rd day)
HHire charges for Temporary illumination, consisting of 100W LED flood light complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.(For 4th to 12th day)
Hire charges for Temporary illumination, consisting of flood light 1000W hallogen with lamp complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.( for 1st to 12th day)
Hire charges for Providing oscillating type pedestal fan 18" with connected wire leads duly dismantled including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge(for 1st day)
Hire charges for Providing oscillating type pedestal fan 18" with connected wire leads duly dismantled including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.(For 2nd and 3rd day)
Hire charges for Providing oscillating type pedestal fan 18" with connected wire leads duly dismantled including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge(For 4th to12th day)
Hire charges for Temporary illumination, consisting of 60W Bulbs complete with 200 Nos required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.(For 1st day)
Hire charges for Temporary illumination, consisting of 60W Bulbs complete with 200 Nos required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge. (For 2nd and 3rd day)
Hire charges for Temporary illumination, consisting of 60W Bulbs complete with 200 Nos required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.(For 4th to 12th day)
Hire charges for Providing and fixing rotating machine to give running effect to strip lights and miniature lights upto a load of 10KW with required wire leads duly dismantled including cost and conveyance of all materials and labour charges etc., complete for 12 Days as directed by Engineer in charge.(For 1st day)
Hire charges for Providing and fixing rotating machine to give running effect to strip lights and miniature lights upto a load of 10KW with required wire leads duly dismantled including cost and conveyance of all materials and labour charges etc., complete for 12 Days as directed by Engineer in charge.(For 2nd and 3rd day)
Hire charges for Providing and fixing rotating machine to give running effect to strip lights and miniature lights upto a load of 10KW with required wire leads duly dismantled including cost and conveyance of all materials and labour charges etc., complete for 12 Days as directed by Engineer in charge.(For 4th to 12th day)
Hire charges for supply and maintaining 125 KVA, 415 voltage, 50 C/s AC generating set with Sound proff all standard accessories such as control panel, batteries etc complete for one day excluding cost of fuel.complete for 12 days as directed by Engineer in charge.(For 1st day)
Hire charges for supply and maintaining 125 KVA, 415 voltage, 50 C/s AC generating set with Sound proff all standard accessories such as control panel, batteries etc complete for one day excluding cost of fuel.complete for 12 days as directed by Engineer in charge.(For 2nd to 8th day)
Hire charges for supply and maintaining 125 KVA, 415 voltage, 50 C/s AC generating set with Sound proff all standard accessories such as control panel, batteries etc complete for one day excluding cost of fuel.complete for 12 days as directed by Engineer in charge.(For 9th and 12th day)
Hire charges for supply and maintaining towards P.V.C pipe 25mm 1.8 mm thickness with junction boxes ,elbowes,bends including with run of cable with necessory terminatrions etc., complete for 12 days as directed by Engineer in charge.(Mandatory) (For 1st day)
Hire charges for supply and maintaining towards P.V.C pipe 25mm 1.8 mm thickness with junction boxes ,elbowes,bends including with run of cable with necessory terminatrions etc., complete for 12 days as directed by Engineer in charge.(Mandatory)(For 2nd and 3rd day)
Hire charges for supply and maintaining towards P.V.C pipe 25mm,1.5 mm thickness with junction boxes ,elbowes,bends including with run of cable with necessory terminatrions etc., complete for 7 days(Mandatory) as directed by Engineer Incharge. (For 4th to 12th day)
Hire charges for Temporary illumination, consisting of 54 Nos*3W Multicolour LED Parcon light complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.. (For 1st day)
Hire charges for Temporary illumination, consisting of 54 Nos*3W Multicolour LED Parcon light complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.. (For 2nd and 3rd day)
Hire charges for Temporary illumination, consisting of 54 Nos*3W Multicolour LED Parcon light complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 12 days as directed by Engineer in charge.. (For 4th to 12th day)
Hire charges for supply and maintaining towards supply and run of 2 of 2.5 sq mm to 6 sq mm VIR/WPTC/WPSC cable with necessary terminations etc, complete for 12 days as directed by Engineer in charge. (For 1st day)
Hire charges for supply and maintaining towards supply and run of 95 sq mm X 3 1/2 crore UG cable with necessary terminations etc., complete for 12 days as directed by Engineer in charge.(For 1st day)
Hire charges for supply and maintaining towards supply and run of 95 sq mm X 3 1/2 crore UG cable with necessary terminations etc., complete for 12 days as directed by Engineer in charge.(For 2nd and 3rd day)
Hire charges for supply and maintaining towards supply and run of 95 sq mm X 3 1/2 crore UG cable with necessary terminations etc., complete for 12 days as directed by Engineer in charge.(For 4th to 12th day)
Hire charges for Temporary illumination, consisting of 100W LED flood light complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge.(For 1st day)
Hire charges for Temporary illumination, consisting of 100W LED flood light complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge.(For 2nd and 3rd day)
Hire charges for Temporary illumination, consisting of 100W LED flood light complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge.(For 4th to 9th day)
Hire charges for Temporary illumination, consisting of RGB (Patty Type) color changing light complete with 1000 Nos. with required wire leads ,Diodes, Control boards,SMPS,Programee chips etc.,duly erected and dismantled with scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge.. (For 1st day)
Hire charges for Temporary illumination, consisting of RGB (Patty Type) color changing light complete with 1000 Nos. with required wire leads ,Diodes, Control boards,SMPS,Programee chips etc.,duly erected and dismantled with scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge. (For 2nd and 3rd day)
Hire charges for Temporary illumination, consisting of RGB (Patty Type) color changing light complete with 1000 Nos. with required wire leads ,Diodes, Control boards,SMPS,Programee chips etc.,duly erected and dismantled with scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge.. (For 4th to 9th day)
Hire charges for Temporary illumination, consisting of 8mm LED colour series light with holders, bulbs, with required wire leads duly erected and dismantled with scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge.(For 1st day)
Hire charges for Temporary illumination, consisting of 8mm LED colour series light with holders, bulbs, with required wire leads duly erected and dismantled with scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge.(For 2nd and 3rd day)
Hire charges for Temporary illumination, consisting of 8mm LED colour series light with holders, bulbs, with required wire leads duly erected and dismantled with scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge. (For 4th to 9th day)
Hire charges for Temporary illumination, consisting of flood light 400W metal halide fitting with lamp complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge. (For 1st day)
Hire charges for Temporary illumination, consisting of flood light 400W metal halide fitting with lamp complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge. (For 2nd and 3rd day)
Hire charges for Temporary illumination, consisting of flood light 400W metal halide fitting with lamp complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge. (For 4th to 9th day)
Hire charges for Temporary illumination, consisting of flood light 1000W hallogen with lamp complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge.. (For 1st day)
Hire charges for Temporary illumination, consisting of flood light 1000W hallogen with lamp complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge. (For 2nd and 3rd day)
Hire charges for Temporary illumination, consisting of flood light 1000W hallogen with lamp complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge. (For 4th to 9th day)
Hire charges for Temporary illumination, consisting of 54 Nos*3W Multicolour LED Parcon light complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge.(For 1st day)
Hire charges for Temporary illumination, consisting of 54 Nos*3W Multicolour LED Parcon light complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge. (For 2nd and 3rd day)
Hire charges for Temporary illumination, consisting of 54 Nos*3W Multicolour LED Parcon light complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for 9 days as directed by Engineer in charge. (For 4th to 9th day)
Hire charges for supply and maintaining 30 KVA, 415 voltage, 50 C/s AC generating set with all standard accessories such as control panel, batteries etc complete for one day excluding cost of fuel for 9 days as directed by Engineer in charge. (For 1st day)
Hire charges for supply and maintaining 30 KVA, 415 voltage, 50 C/s AC generating set with all standard accessories such as control panel, batteries etc complete for one day excluding cost of fuel for 9 days as directed by Engineer in charge. (For 2nd and 8th day)
Hire charges for supply and maintaining 30 KVA, 415 voltage, 50 C/s AC generating set with all standard accessories such as control panel, batteries etc complete for one day excluding cost of fuel for 9 days as directed by Engineer in charge. (For 9th day)
Hire charges for supply and maintaining 15 KVA, 415 voltage, 50 C/s AC generating set with all standard accessories such as control panel, batteries etc complete for one day excluding cost of fuel for 9 days as directed by Engineer in charge. (For 1st day)
Hire charges for supply and maintaining 15 KVA, 415 voltage, 50 C/s AC generating set with all standard accessories such as control panel, batteries etc complete for one day excluding cost of fuel for 9 days as directed by Engineer in charge.(For 2nd to 8th day)
Hire charges for supply and maintaining 15 KVA, 415 voltage, 50 C/s AC generating set with all standard accessories such as control panel, batteries etc complete for one day excluding cost of fuel for 9 days as directed by Engineer in charge. (For 9th day)
Hire charges for Temporary illumination, consisting of RGB (Patty Type) color changing light complete with 1000 Nos. with required wire leads ,Diodes, Control boards,SMPS,Programee chips etc.,duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for one day as directed by Engineer incharge.
Hire charges for Temporary illumination, consisting of 100W LED flood light complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for one day as directed by Engineer incharge.
Hire charges for Temporary illumination, consisting of flood light 1000W hallogen with lamp complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for one day as directed by Engineer incharge.
Hire charges for Temporary illumination, consisting of flood light 400W metal halide fitting with lamp complete with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for one day as directed by Engineer incharge.
Hire charges for Temporary illumination, consisting of white/colour series light 6.2v complete with 1000 Nos. with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for one day as directed by Engineer incharge.
Hire charges for Temporary illumination, consisting of 8mm LED colour series light with holders, bulbs, with required wire leads duly erected and dismantled without scaffolding including cost and conveyance of all materials and labour charges etc., complete for one day as directed by Engineer incharge.
Hire charges for supply and maintaining 62.5 KVA, 415 voltage, 50 C/s AC generating set with all standard accessories such as control panel, batteries etc complete for one day excluding cost of fuel for one day as directed by Engineer incharge.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
TQ-WPT.docx
TENDER_DOCUMENT • 0.03 MB
Bid Water proof treatment.docx
TENDER_DOCUMENT • 0.49 MB
BOQ.xlsx
TENDER_DOCUMENT • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .