Manager SRC-OS
Hindustan Shipyard Limited Gandhigram SR Complex Visakhapatnam 530 005
Electrical Works on ORV SAGAR KANYA
2024_HSL_94761_2
20 / 22022 / 005 / Electrical Works / 2024-25
Open Limited
Miscellaneous Services
Service
30 days
HSL Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹525
Yes
HSL
₹30,000
Yes
14 Jun 2024
19 Apr 2024
29 Apr 2024
19 Apr 2024
29 Apr 2024
19 Apr 2024
Amount
Magnetic compass calibration / deviation to be carried out during sea trials. Deviation Certificate to be issued. Note: Any Spares & consumables required are under vendor scope.
Telephones 1) Two new telephones are required in wet lab (stbd) and cabin no. 418. Lines also to be examined repaired for frequent connection issues in these two rooms.Qty - 02 Nos 2) F-deck cabin 421 and 423 new phones are required. Conduit pipe of length 1m is required for the phone connection cable.Qty - 02 Nos 3) F-deck cabin 418 phone connection and telephone required.Qty - 01 No 4) Crew galley (2nd deck): one telephone in galley and one in the crew mess room with new cable connection required.Qty - 02 Nos Note: Any Spares & consumables required are under vendor scope. Satisfactory Trials to be shown to SS / HSL after completion of job.
Air circuit breakers 1) Following air circuit breakers to overhaul no volt trip overload trip reverse power trip short circuit to calibrate and test and breakers to be fitted in place and tested 2) Alternators breakers:660v 1600amp stype: AEG ME 1600.Qty - 05 Nos 3) Propulsion motors:660v 1600amps.Qty - 05 Nos 4) Tranformers:660v 630amps.Qty - 05 Nos 5) Tranformers:390v 630amps.Qty - 01 No 6) Non essential breaker: 390v 1000amps.Qty - 01 No 7) Transfer line breaker: 390v630 amps.Qty - 01 No 8) Bow thruster breaker: 660v 800amps.Qty - 01 No 9) Azimuth thruster breakers:660v 800amps.Qty - 01 No 10) Spare ACB in engine control room to be serviced.Qty - 01 No Note: Any Spares & consumables required are under vendor scope. After Calibration trials to be offered to SS / HSL and submit Calibration reports of Breakers along with Calibration Certificate of necessary "Master Calibration kit / Equipment". ( ie. Which equipment is going to be use for Breakers calibration, that equipment Valid calibration cretificate also need to attach with reports).
Calibration of Meters 1) CALIBRATION : Following meters on main switch board to be calibrated and certificates to be provided 2) Double frequency meter 45 to 55hz.Qty - 05 Nos 3) Double volt meters 0 to 800volts ac.Qty - 05 Nos 4) Ammeters 0 to 3000amps ac.Qty - 05 Nos 5) Kilowatt meters 0 to 1200kw.Qty - 05 Nos 6) Following ammeters, voltmeters, pressure and temperature indicator in ECR console to be calibrated and certificates to be produced 7) Voltmeters.Qty - 05 Nos 8) Ammeters 0 to 3000amps AC.Qty - 05 Nos 9) Pressure indicators.Qty - 05 Nos 10) Temperature indicators.Qty - 04 Nos 11) E Shaft tachometer of main electrical propulsion motors on bridge and ECR.Qty - 02 Nos 12) The following electrical measuring instruments to be calibrated and certificates to be produced 13) Multimeter:make: motwane dm 3540.Qty - 01 No 14) Megger:make: meco 2853.Qty - 02 Nos 15) Tong tester:make: kyroitsu 2805.Qty - 01 No After Calibration of meters, vendor should submit Calibration reports of meters along with Calibration Certificate of necessary "Calibration kit / Equipment".
Various Meters in Engine room to be calibrated and certificate to be issued Note : Scope of work is enclosed (4 pages). Qty - 01 LS
Main Switch Board & Emergency Switch Board 1) Main-switch-board & emcy switchboard are to be inspected, connections and components to be checked. Switch boards to be cleaned, Initial vaccum clean to be carried out. Insulation to be recorded in presents of SS / HSL. All internal and external parts to be wiped out and cleaned free from dust. Blow through with hot air, clean and insulation to be improved. Inspection / Calibration of MCCBs to be carried out. After completion of work final insulation to be shown to ship staff / HSL. At no load condition, if insulation is < 200MOhms, necessary job to be carried out for improving the insulations. 2) 660 V insulation meter showing less ohmic value during pm manoeuvring fault to be trace and rectify.Qty - 01 LS 3) Insulation meter for 390 v panel and 220 v panel working condition need to be checked.Qty - 02 LS 4) 230V & 390 V INSULATION METER NOT WORKING, SAME TO BE RECTIFIED IN MSB PANEL BOARD.Qty - 02 Nos All Spares / consumables required are under vendor scope. Satisfactory Trials to be shown to SS / HSL after completion of job.
AUDIBLE ALARMS IN PM ROOM NEED TO BE MADE OPERATIONAL. Note: Any Spares & consumables required are under vendor scope. Satisfactory Trials to be shown to SS / HSL after completion of job.
1) Provision lift for galley Not in operation. Same to be made operational. Note: Any Spares & consumables required are under vendor scope. Satisfactory Trials to be shown to SS / HSL after completion of job.
2) Wipers on bridge navigational glass to be renewed.Qty - 03 Nos Note: Any Spares & consumables required are under vendor scope. Satisfactory Trials to be shown to SS / HSL after completion of job.
3) Ship`s laundry machine to repaired.Qty - 01 No Note: Any Spares & consumables required are under vendor scope. Satisfactory Trials to be shown to SS / HSL after completion of job.
4) Testing board in Electrical workshop needs to be made operational.Qty - 01 No Note: Any Spares & consumables required are under vendor scope.
5) Maintenance is needed for UV sterilizers and lamps need to be changed. Whenever the sterilizer is started, it shows lamp failure indication. Defect to be rectified. Note: Any Spares & consumables required are under vendor scope. Satisfactory Trials to be shown to SS / HSL after completion of job.
6) BATTERY CHARGER FOR ALDIS LAMP 0-10 AMPS ,7- 28 VOLT MAKE: DENKI ENG CO. BOMBAY. Not working, to be repaired or new one to be supplied. Note: Any Spares & consumables required are under vendor scope. Satisfactory Trials to be shown to SS / HSL after completion of job.
7) Top cover/lid of the box for lifeboat batteries is damaged/ sagged. New cover to be made of Fiberglass of size around 1.8m x 0.8m. Note: Any Spares & consumables required are under vendor scope.
ECR steering gear ECR steering gear monitoring system not working, to be made operational. All the service / Spares and consumables in vendor scope. Satisfactory Trials to be shown to SS / HSL after completion of job.
PROPELLER SHAFT EARTHING (MAKE:TWIFLEX,TYPE:NR 663079) MADE IT OPERATIONAL. Note: Any Spares & consumables required are under vendor scope. Satisfactory Trials to be shown to SS / HSL after completion of job.
Domestic fridge compressor panel wire, components, terminals need to be renewed. Function test to be carried out to the satisfaction of ship staff. Spares/consumables required are under vendor scope.
175kW AC compressor panel complete wiring, components, terminals need to be renewed. Function test to be carried out to the satisfaction of ship staff. Spares/consumables required are under vendor scope. Vendor has to provide Wiring diagram after completion.
SRI VINAYAKA MARINE SERVICES
DELTA MARINE ENGINEERS
SHARP ELECTRICAL AND MECH ENGG SERVICES
GBR MARINETECH SERVICES
Marine Electrical Refrigeration & engineering Works LLP
VIJAYA TECHNO ENTERPRISES
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Restricted Tender
This is a Open Limited tender. Documents are accessible only to bidders authorized by the issuing authority on the government portal.
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .