Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC | L1 | Accepted-AOC First Lowest Bidder | |
| 2 | L2₹14.9 L+₹21,461 (1.46%)Rejected-Finance | L2 | Rejected-Finance Second Lowest Bidder | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹14.0 L
EMD Value
₹28,060
Closing Date
9 Mar 2024, 4:00 pmClosed
Executive Engineer, Electrical Division
Farakka Barrage Project, P.O. Farakka Barrage, Dist. Murshidabad, West Bengal, PIN 742212
As per tender document
2024_FBPF_798508_1
GM/FBP-47 of 2023-24
Open Tender
Electrical Works
Item Rate
120 days
Farakka
As per tender document
2 documents required · 2 mandatory
₹0
₹28,060
Yes
27 Nov 2024
2 Mar 2024
11 Mar 2024
2 Mar 2024
9 Mar 2024
2 Mar 2024
Amount
Supplying and fixing Sheet steel Main Switches on flat iron frame on wall. 240 V DP with fuse on L & N, 30/32 A, Havells.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single Pole.
Single Pole
Double Pole
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works, 25X10 mm size
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 6 sq. mm
3 x 4 sq. mm
3 x 2.5 sq. mm
3 x 1.5 sq. mm
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface] Average run 12 mtr.
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 amps switch
3 pin 5/6 A socket outlet
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to therequired shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25 mm
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 25 mm dia nominal bore
Supply and fixing of exhaust fan, sweep size- 300 mm, capacitor type, 4 pole, fan motor totally enclosed of reputated brand conforming to IS: 2312 latest.
Supply of LED street light, 45 watts, 230 V, 50 Hz, polycarbonate lense optics, of reputed brand conforming to IS:16107 (Part 2/Sec 1):2012latest.
Supply and deliver of Pedestal Type Fan and Regulator, capacitor type,230 V, 50 Hz, 500mm,IP 21, Adjustable height, Min. 900 mm Max. 1050 mm(for 400 mm size fan), minimum air delivery 90 m3, steel material stand fan of reputated brand conforming to IS:1169 : 1967 latest.
Supply and installation of 20 watt, LED Tubelight, 1150 length, 100 lumen per watt, 6500 K colour temp, polycarbonate material, in brand conforming to IS:10322-5-2(2012)
Supplying and fixing 9 watt LED Bulb, 240 V, 50 Hz, 2700 K colour temp, polycarbonate material in brand conforming to IS:16102 (Part 2):2017 latest.
Supplying & Drawing 3 core, 4 sqmm PVC armoured aluminium cable of reputated brand conforming to as per IS:1554 (Part 1):1988 latest.
Supplying & Drawing 3 core, 4 sqmm PVC unarmoured aluminium cable of reputated brand conforming to as per IS:1554 (Part 1):1988 latest.
M/S ROY CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .