Loading…
Loading…
Tender ID
Tender Value
₹11.6 L
EMD Value
₹23,144
Closing Date
20 Feb 2026, 4:00 pmClosed
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX RAJ BAGH
Construction of 10 roomed building at HSS Tilgam Baramulla B.W.O Electric work
2026_PWDJK_303120_1
NIT No.293/2025-26 Dt/13/02/2026
Open Tender
Electrical Works
Percentage
Tilgam Baramuula
Please refer Tender documents.
4 documents required · 4 mandatory
₹600
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹23,144
13 Feb 2026
13 Feb 2026
21 Feb 2026
13 Feb 2026
20 Feb 2026
13 Feb 2026
Wiring for light point / exhaust fan point/ceiling fan point with (P+N) 2X1.5 sq.mm FRLS-H ( Polycab/Havells/Finolex/eqt make as approved by site engineer),PVC insulated copper conductor single core cable in surface / recessed Conduits (Anchor/polycab/Ravindra/equivalent make as approved by site engineer) , with 6Amp .modular switch (Anchor roma urban/legrand/SSK NV/equivalent make as approved by site engineer), modular plate, cover in front and suitable GI box (Excld. G.I Box laid earlier ) etc of approved quality and make ISO/IEC Certified (quality of wire shall be approved before execution of wok by SITE In-charge Engineer strictly as required) job including cost of Circuit Wire in 2.5Sqmm Multi strand Copper wire from Switch board to D.B complete. excluding cost of Conduits. separate 2.5 sq mm circuit wire for inverter points
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor Roma plus/SSK NV/ equivalent make as directed by engineer incharge.
Wiring for 6Amp Plug with(P+N+E) 3 x 2.5 sq.mm FRLS PVC ,Polycab/Havells/Finolex/eqt make as approved by site engineer) Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit along with 1 x 2.5 sq.mm FRLS,Polycab/Havells/Finolex/eqt make as approved by site engineer) PVC Insulated copper conductor single core cable for loop Earthing of approved quality and ISI marked as required. with ,2No.6Amp .Modular switch(Anchor roma urban/legrand/SSK NV/equivalent make as approved by site engineer), 2, 2NO. Modular 6 Amp. 5-PIN Socket ,6-8 Module Modular gride plate, cover and suitable GI box etc (Excld. G.I Box laid earlier )as required (wire shall be approved before execution of wok by SITE In-charge Engineer strictly , connections etc. as required.) complete excluding cost of Conduits
Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H ( Polycab/Havells/Finolex/eqt make as approved by site engineer)PVCInsulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Anchor/polycab/Ravindra/equivalent make as approved by site engineer) along with 1 x 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop Earthing of approved quality and ISI marked as required. With . 1NO. 16Amp .Modular switch(Anchor roma urban/legrand/SSK NV/equivalent make as approved by site engineer), Modular 1NO.3-PIN . 16 Amp. Socket , Modular plate, cover and suitable GI box (Excld. G.I Box laid earlier )etc as required . ( without loop circit)
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/ Recessed medium class PVC conduit as required. (wire shall be approved before execution of wok by SITE In-charge Engineer strictly .
2X 10sq. MM+ 1 X 10 sq. MM (Phase +N+E) Power point Sub main in One runFrom Main Panel to .Distribution boards(Polycab/Havells/Finolex/eqt make )
2 X 6SQ.MM + 1 X 6. SQ.MM [Phase +N+E) For Lighting and Inverter Sub main in one run from Main Panel to Distribution board(Polycab/Havells/Finolex/eqt make)
2 X 4SQ.MM + 1 X 4SQ.MM [Phase +N+E) For ac and Inverter Sub main in one run from Main Panel to Distribution board(Polycab/Havells/Finolex/eqt make)
Supplying and fixing of 32Amp Rating ,240v, *C* Curve Miniature Circuit Breaker suitable for inductive load of following poles in existing DB . Complete with connections ,testing and commissioning etc as required Legrand /Havells or L&T /Schneider/ABB/siemens
SINGLE POLE (6-16Amp) Legrand /Havells or L&T /Schneider/ABB/siemens
Supplying and fixing following rating, Double pole, (P +N) 240 V, C* Curve Residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as reqd.
32 Amp. Legrand /Havells or L&T /Schneider/ABB/Siemens
40Amp. Legrand /Havells or L&T /Schneider/ABB/Siemens
63Amp. Legrand /Havells or L&T /Schneider/ABB/ Siemens
Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board,( Havell/ legrand/ Shinider/SSK make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
6 way, Double door
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 2OMM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job
Supply installation testing and commissioning of 18 W + commercial type LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India authorised lab . The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips or Havel's or Wipro or Jaguar or Surya or Veto or Panasonic or LUKEER make
Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells/Polycab/ LUKER USA (3 star)
Supply,Installation,Testing and Commissioning 320 Cu.m/Hr. AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37 dB of Following Sizes including connection etc. Compt 225-250mm Shutter Typed
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supply, laying, Connecting and Commissioning of 95sq mm 3.5core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havel’s /with required size of thimbles dully crimped with hydraulic crimping tool including p/ fixing of saddles /clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench
Supply, Laying, testing and commissioning of 25 mm dia. High class PVC conduit Heavy Duty, Unbreakable conduits to be laid in RCC Slab and downs in walls including cutting the wall and making good the same with 1:6 mix cement plaster in case of recessed conduit as required etc including cost of accessories like bends and ‘heavy Gauge Sheet Steel Deep Junction boxes of approved make .(Before laying of conduit the same to be approved by site Engineer) . Preferred make: Ravindera /Anchor/Alba/Polycab make.
Supply, Laying, testing and commissioning of 32 mm dia. High class PVC conduit Heavy Duty, Unbreakable conduits to be laid in RCC Slab and downs in walls including cutting the wall and making good the same with 1:6 mix cement plaster in case of recessed conduit as required etc including cost of accessories like bends and ‘heavy Gauge Sheet Steel Deep Junction boxes of approved make .(Before laying of conduit the same to be approved by site Engineer) . Preferred make: Ravindera /Anchor/Alba/Polycab make.
Supplying, Installation, Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical fires
Supplying, Installation, Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified
Providing and Laying of shock proof rubber mats of 2mm*1mm*12mm thick insize of standard make
Supply installation tesyting and commsiioning of 32 A Modular plug/Socket with 32 A DP MCB for AC.( Legrand/SSK/Heager make)
Supply, installation, testing& Commissioning of Bulk Head Fittings of Havel's RUGBY Model HAVEL'S BULK HEAD Fittings with 12watt LED Bulb of Philips or Havel’s /wipro make sample to be approved before installation
Supply installation testing and commissioning of Sine Wave Inverter Capacity 10kVA, Rated Power 8.4 KW ,Supports fOUR battery(12 V EACH),180AH),24 Month Warranty Safe for sensitive appliances with Sine wave out-put,, Auto over-load handling capacity Installation and maintenance friendly Offers high quality and reliable power back-up solution for office and homes ,MCB for protection from Input mains,Bypass switch for supplying output directly from grid in case of Home UPS fault.Noiseless Operations with the help of low harmonic distortion, Intuitive Display to easily understand status of mains availability, battery status, etc.Comprehensive protection against short-circuit, reverse polarity, battery over-charge, deep- discharge etc.Adaptive Battery charging control system technology (ABCC) ensures faster battery charging and enhances battery life by around 70%.Supports a wide battery range, i.e. Flat Plate, Tubular & VRLA (SMF).praffered make Luminous/ Microtek/Exide.the job also includes trolly for housing 4 No battries and inverter.
Supply/Fixing of water Dispenser with refrigerator Hot and Cold Taps of capacity 10 litres Acrylonitrile Butadiene styrene (ABS) of Blue/ Voltas/ Honeywell make and shall be approved bbefore supplying ( 3star)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.08 MB
BOQ_983769.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .