| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC 16 12A SWAMIJI ROAD NEAR SABUJ SANGHA KOLKATA WEST BENGAL 700060 | KOLKATA | WEST BENGAL | 700060 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹30.3 L+₹2.6 L (9.52%)Rejected-AOC BAIKUNTHAPUR S T K K ROAD TRIBENI HOOGHLY 712503 | TRIBENI | HOOGHLY | WEST BENGAL | 712503 | L2 | Rejected-AOC L2 | |
| 3 | L3₹39.8 L+₹12.1 L (43.7%)Rejected-AOC MAJIRHAT MECHEDA DIST PURBA MEDINIPUR PIN 721137 | MECHEDA | PURBA MEDINIPUR | WEST BENGAL | 721137 | L3 | Rejected-AOC L3 | |
| 4 | Not Admitted-Fee | - | Not Admitted-Fee EMD/Instrument is not valid |
Tender Value
₹31.1 L
EMD Value
₹62,200
Closing Date
6 Jul 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GM gtpp
Admin building SgTPP sgtpp manigram Dist Murshidabad pin 742237
Overhauling of Duct Damper Expansion Bellows Gates and Actuators at UnitI SgTPP
2021_WBPDC_330483_1
WBPDCL/SGTPP/NIT/E1565/20-21
Open Tender
Support/Maintenance Service
Lump-sum
21 days
sgtpp manigram Dist Murshidabad
As per NIT
3 documents required · 3 mandatory
₹0
₹62,200
Yes
Admin building SgTPP
25 Aug 2021
7 May 2021
9 Jul 2021
7 May 2021
6 Jul 2021
7 May 2021
24 May 2021
120 days
REPAIRING OF AIR /FLUE DUCTS AS PER SCOPE OF WORK.
REPLACEMENT OF CLOTH TYPE EXPANSION BELLOW: Size 2750x1720mm, having Total length 10500mm, width 270mm, Design Temperature # 3380c, Pressure 1650mmWC, Material of Construction # Four layers with each of Woven glass Fabric, Needled Glass felt, PTFE Foil, Both side Elastomer coated glass fabric. Used in Hot PA at APH Outlet.
REPLACEMENT OF CLOTH TYPE EXPANSION BELLOW: Size 1700x2400mm, having Total length 10150mm,width 465mm, ,Material of Construction # Four Layers with each of Woven glass Fabric, Needled Glass felt, PTFE Foil, Both side Elastomer coated glass fabric. Used in Hot PA Outlet in the horizontal legs before entry to Hot PA Header(Between FD& PA Fan Area).
REPLACEMENT OF CLOTH TYPE EXPANSION BELLOW: Size 1800x1100mm, having Total length 8050mm, width 580mm, Four layers with each of Woven glass Fabric, Needled Glass felt, PTFE Foil, Both side Elastomer coated glass fabric. Used in PA Inlet to Coal Mill.
REPLACEMENT OF CLOTH TYPE EXPANSION BELLOW: Size 6108X3542 MM, having total length 22000 MM, Width 235 MM,design temperature 128 DegC, Pressure 2050 MMWc, material of construction Buto EP, resin bonded glass felt encased in ss wire & glass fabric. Used in APH outlet convergent flue duct.
REPLACEMENT OF CLOTH TYPE EXPANSION BELLOW: Size 3200X3000 MM, Having total length 14300 MM, Width 300 MM, design temperature 128 DegC, pressure 2050 MMWC,material of construction Buto EP, resin bonded glass felt encased in ss wire mesh & glass fabric used in flue duct. Used in flue duct before and after ESP.
REPLACEMENT OF CLOTH TYPE EXPANSION BELLOW AS TABULATED BELOW: Non Mettalic Expansion Joint Fabric Cloth for joint size 9000X2000MM, having total length 24600MM, width 212MM, design temperature 128DEG.C, pressure 2050MMWC,expansion axial 23MM &lateral 10MM,material of construction BUTO EP, resin bonded glass felt encased in SS wire mesh & glass fabric. Used in APH Outletbflue duct just before convergent duct in the verticle direction at around 8.5M elevation.
REPLACEMENT OF CLOTH TYPE EXPANSION BELLOWS: Non Metallic Expansion Joint Fabric Cloth for joint size 6714X3820MM, having total length 23800MM, width 290MM, design temperature 344DEG.C, pressure475MMWC,expansion axial 30MM &lateral 30MM,material of construction woven glass fabric, needled glass felt, PTFE FOIL, both side ELASTOMER coated glass fabric,SUPER WOOL & RESIN BONDED glass felt encased in ss wire mesh & woven glasss fabric. Used in SA line at APH OUTLET.
REPLACEMENT OF CLOTH TYPE EXPANSION BELLOW:NON METALLIC EXPANSION JOINT FABRIC CLOTH FOR JOINT SIZE 2750X1720MM, HAVING TOTAL LENGTH 10500MM, WIDTH 245MM, DESIGN TEMPERATURE 50DEG.C, PRESSURE 2050MMWC, EXPANSION AXIAL 30MM & LATERAL 30MM, MATERIAL OF CONSTRUCTION BUTO EP, RESIN BONDED GLASS FELT ENCASED IN SS WIRE MESH & GLASS FABRIC. USED IN COLD PA LINE AT APH INLET.
REPLACEMENT OF CLOTH TYPE EXPANSION BELLOW: NON METALLIC EXPANSION JOINT FABRIC CLOTH FOR JOINT SIZE 3820X3500MM, HAVING TOTAL LENGTH 17000MM, WIDTH 455MM, DESIGN TEMPERATURE 344DEG.C, PRESSURE 475MMWC, EXPANSION AXIAL 70MM & LATERAL 50MM,MATERIAL OF CONSTRUCTION WOVEN GLASS FABRIC, NEEDLED GLASS FELT, PTFE FOIL, BOTH SIDE ELASTOMER COATED GLASS FABRIC,SUPER WOOL & RESIN BONDED GLASS FELT ENCASED IN SS WIRE MESH & WOVENGLASS FABRIC. USED IN SA LINE AT Y AFTER APH
REPLACEMENT OF CLOTH TYPE EXPANSION BELLOW: NON METALLIC EXPANSION JOINT INSULATION BOLSTER FOR JOINT SIZE 4000X5000 MM, HAVING TOTAL LENGTH 18200MM, WIDTH 160MM, HEIGHT 100MM, DESIGN TEMPERATURE 128DEG.C, PRESSURE 2050MMWC, EXPANSION AXIAL 12MM & LATERAL 23 MM, MATERIAL OF CONSTRUCTION RESIN BONDED GLASS FELT ENCASED IN SS WIRE MESH & WOVEN GLASS FABRIC. USED IN FLUE DUCT HEADER BEFORE ESP INLET.
REPLACEMENT OF CLOTH TYPE EXPANSION BELLOW:NON METALLIC EXPANSION JOINT FABRIC CLOTH FOR JOINT SIZE 6714X3820MM, HAVING TOTAL LENGTH 23550MM, WIDTH 225MM, DESIGN TEMPERATURE 50DEG.C, PRESSURE 450MMWC, EXPANSION AXIAL 30MM & LATERAL 30MM, MATERIAL OF CONSTRUCTION BUTO EP, RESIN BONDED GLASS FELT ENCASED IN SS WIRE MESH & GLASS FABRIC. USED IN SA LINE AT APH INLET.
REPLACEMENT OF CLOTH TYPE EXPANSION BELLOW: NON METALLIC EXPANSION JOINT FABRIC CLOTH FOR JOINT SIZE Ø920MM, HAVING TOTAL LENGTH 4000MM, WIDTH 235MM, DESIGN TEMPERATURE 50DEG.C, PRESSURE 2050MMWC, EXPANSION AXIAL 27MM & LATERAL 25MM,MATERIAL OF CONSTRUCTION BUTO EP, RESIN BONDED GLASS FELT ENCASED IN SS WIRE MESH & GLASS FABRIC. USED IN COLD PA INLET AT HOT PA DUCT TO MILL.
Only Cloth replacement at ID Fan suction bellow Size # 1750x3100
Repairing of cloth type Bellows by patch work
Repairing of Metallic Expansion Bellows by Run welding
Repairing of Metallic Expansion Bellows by Run welding
Run welding for patch work/repairing of work where no new plate is required.
Replacement of metallic expansion bellow of Economiser outlet
Servicing of Hot air damper,gates & actuators as tabulated below as per scope of work
Servicing of Cold air damper,gates & actuators as tabulated below as per scope of work
Servicing of Seal air fan suction dampers, actuators as tabulated below as per scope of work(01 Motorised+01 Manual)
ID Fan suction Damper (2 nos 4 blade dampers = 1 set)
PA Fan Interconnection Damper
FD Fan Discharge Damper
FD Fan Interconnection Damper
APH O/L PA damper
APH I/L PA damper
APH Outlet SA Damper (2 Nos. 4 Blade Dampers= 1 Set)
APH Inlet SA Damper (2 Nos. 4 Blade Dampers= 1 Set)
ID Fan Inlet Gates
ID Fan O/L Gate
ESP Inlet & Outlet Guillotine Gate
Seal Air Supply to Mill Valve/ Gate Actuator
Hot Air Gate Lock Actuator
Cold Air Gate Lock Actuator
ID fan Suction & discharge side Guillotine Gate Actuator
PA Fan Discharge Gate Actuator
PA Fan Discharge Gate Lock Actuator
PA Fan Discharge duct Interconnection Damper Actuator
FD Fan Discharge Damper Actuator
FD Fan Discharge Duct Interconnection Damper Actuator
PA Damper At APH Inlet & Outlet
SA Damper At APH Inlet & Outlet
ESP Inlet & Outlet Guillotine Gate Actuator
SAP ENTERPRISE PRIVATE LIMITED
ASSOCIATE ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .