Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹42,267
Closing Date
28 Sept 2026, 11:00 am5d left
Executive Engineer PWD Electrical Division Kannur
PWD Electrical Division, Kannur
LAC-ADS-2024-25- Kallyasseri LAC - Sri.M Vijin MLA -Installation of Lights at Cherukunnu town-SITC of Decorative LED lights-General Electrical Work
2026_PWD_871801_1
PWD/BLDG/TR/23064/2025_6_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
Kannur
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹42,267
22 Sept 2026
22 Sept 2026
30 Sept 2026
22 Sept 2026
28 Sept 2026
22 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Footpath Lighting | |||||
| 1.001 | OD249497/2025-2026:Supply installation testing commissioning of Decorative Pole 3.2/3 meter height above the
ground level made out of GI, tubular pole having two section section, bottom section of
minimum 900/1000mm with base dia of 114mm and upper section of minimum 2300/2000mm
with dia of 76mm. The pole shaft shall be as per IS 1161. The pole shall have base plate of
dimension 200x200x12mm including minimum16mm diameter 4 numbers foundation bolts of
450mm bolt length, 200mm pitch circle diameter manufactured from special steel along with
nuts, washers, The pole shall be with inbuilt control gear tray at bottom section. The control
gear tray is prewired with 2.5 Sq.mm cable, 6A SP MCB and 32A stud type 4 way
terminal block for loop-in / loop-out arrangement, 6 A 2 Way terminal connector and provision
for earthing.The pole shall be suitable for wind loadings as per IS 875 part 3 1987. Design
comply EN40 standard and basic wind speed 169kmph. Pole should hot dip galvanized to 65
microns to IS 2629:985/ IS 4759:1996 / IS 2633:1986. The Pole should be given with two coats
of epoxy primer and above that it should be given marine coating. The complete system should
be hot dipped Galvanised. (K lite COLOMBIA/Kesslec RILA/CHATSWORTH). | 46 | each | - | - |
| 1.002 | OD146917/2026-2027:SITC of LED Decorative Classic luminaire of system wattage 50W, with minimum dimension
315mm width and 545mm height, BIS certified with a body
and frame of high pressure die cast aluminium, a frosted PMMA protector (IK06) fixed on to
the optical unit
, separate optical and control gear compartment accessed by opening four
screws at the top of the luminaire, a vent pressure equalization unit and pre-cabled as
required. The luminaire shall have ingress protection of IP65. Highly efficient temperature
resistant lenses for light distribution with several optical options providing excellent
photometry to optimally cater to different applications. Overall system efficiency of
120lm/W at correlated colour temperature (CCT) 3000K, colour rendering index (CRI) >70
and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor > 0.95, with BIS certified potted driver having internal surge protection of 4 kV .
(KESSLEC RILA 50W WW/ Klite DYNASTY MIDI 50W WW) | 46 | each | - | - |
| 1.003 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 7 | cum | - | - |
| 1.004 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). | 8.8 | cum | - | - |
| 1.005 | OD249498/2025-2026:Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing
in position and binding all complete .Thermo-Mechanically Treated bars of grade Fe-500D or more. | 184 | per kg | - | - |
| 1.006 | 90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm | 350 | metre | - | - |
| 1.007 | 90.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm | 450 | metre | - | - |
| 1.008 | 9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for
following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade as required.2 X 10 sq. mm (19mm) | 50 | set | - | - |
| 1.009 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for
following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade as required.2 X 6 sq. mm (19mm) | 42 | set | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
viewnit.pdf
Tender Documents • 0.02 MB
viewsbd.pdf
Tender Documents • 1.63 MB
mom.pdf
Other Document • 0.26 MB
specificcondition.pdf
Additional Documents • 0.34 MB
BOQ_1478013.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .