Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.4 LAccepted-Finance FLAT NO 18 3RD FLOOR QUEENS CASTLE 100 FEET ROAD LAKSHMI NAGAR NANGANALLUR CHENNAI 600 061 | CHENNAI | TAMIL NADU | 600061 | ₹56.4 L | L1 | Accepted-Finance L1 |
| 2 | L2₹57.2 LRejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | ₹57.2 L | L2 | Rejected-Finance L2 |
| 3 | L3₹59.9 LRejected-Finance | ₹59.9 L | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | Balaji Engineering L1 | Manish Electricals L2 | DY Infra & Projects Private Limited L3 |
|---|---|---|---|---|---|---|
| 1.00Supply, installation, testing and commissioning of prime rated 30 KVA DG Set along with acoustic enclosure including providing foundation platform as per OEM Design and minor civil works if required, meeting CPCB Pollution Norms of CPCB IV+ as applicable on the Day of submission of Tender and comprising of following: (A) 01 No. Alternator suitable for generating 24 KW/30 KVA at 415 V, 3 Phase, 50 Hz, 0.8 PF, 1500 RPM, Self ventilated, Self regulated and Self excited with brushless type with Class H Insulation etc., conforming to IS 15999 as specified and as required. (B) 01 No. Multi cylinder, 4 Stroke, Turbo charged Diesel Engine developing suitable BHP at 1500 RPM suitable for above mentioned alternator and complete with all accessories such as base frame, AVM Pads, Battery of 12V 180AH, All types of filters (Including Air filter of heavy duty), Coupling, starter, Automatic electronic speed governing mechanism, Compact radiator etc., and conforming to relevant IS with up to date amendments as specified and as required. (C) Integrated microprocessor based generator set control system providing digital voltage regulation, Engine protection, Alternator protection, Isochronous governing switch for AMF Function, Battery monitoring, Operator interface, Communication interface etc., as specified and as required. (D) 1 No. Integral control / Isolator panel made of 2mm thick CRCA Sheet, comprising of DG Controller (as mentioned above), Copper bus bars of capacity not less than 160 Amps with incoming / outgolng terminals, Indicating lamps for 'Load ON' and 'Set running', Instrument fuses duly wired and ferruled, 4P MCCB of 160 Amps 36 KA rating with Overload, Short circuit and Earth fault protections of microprocessor based as required. (E) 1 No. inbuilt Fuel tank of capacity as per OEM Design complete with connecting pipes, valves, fuel level indicators etc., as specified and as required. (F) Customised Compact Modular Type Tested Acoustic Enclosure suitable for the above DG Set to limit the Noise Level to 75 dB (A) at a distance of 1 Mtr., from the Enclosure, made out of CRCA sheet of 1.6 mm thickness for the Outside Cover and Doors and for Inside Cover with 0.8 mm thick perforated GI Sheet, Louvers of thickness 1.6 mm CRCA Sheet for Fresh Air and Hot Air, Powder coated after Seven Tank Process, Neoprene Rubber Gasket and heavy duty SS locks with SS Hinges, Acoustic made up of high quality rock wool/glass wool/ mineral wool as per OEM design, Base Frame of suitable Size Channel, provision to accommodate Batteries, and Support for Silencers, provided with 4 Nos. LED Tube light Fittings of 2 feet and Switches as required. | ||||||
| 1.01 | (G) Exhaust gas piping for above DG of suitable dia.welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, bellows, residential silenser, insulation of exhaust system with mineral wool/Rockwool 50 mm thick, wire mesh & aluminium cladding of minimum thickness of 0.6 mm etc., as required meeting CPWD/PCB/AAI Specifications.
All Above 1(A) - 1 (G) | 2 | Job | 9,00,000 ₹18,00,000 | 9,85,000 ₹19,70,000 | 6,76,000 ₹13,52,000 Lowest |
| 2.00 | Fabrication, SITC of MV Switch Board [AMF] Panel made of 14 SWG CRCA Sheet Steel, dust tight, vermin proof, Totally enclosed, cubicle type, Confirming to IP 42, floor mounting, free standing, extensible on both sides, suitable for indoor operation at 433 V, 3 Phase, 4 Wire, 50 Hz, A.C.System complete with all accessories, interconnection, connection, earthing, painting, cable entry provision, provided with bottom base channel and locking arrangements including grouting etc., as required and comprising of the following:
(A) One No. 160 A, 36KA, 4P, MCCBs with Thermal Magnetic Releases for OC/SC/EF Protection with microprocessor based releases for EB Supply with CT operated 3 Phase digital protective relay, CT Operated Digital Meter, ON/OFF/TRIP Indication and Phase Indication Lamps.
(B) One No. 160 A, 36KA, 4P, MCCBs with Thermal Magnetic Releases for OC/SC/EF Protection with microprocessor based releases for DG Supply with CT operated 3 Phase digital protective relay, CT Operated Digital Meter, ON/OFF/TRIP Indication and Phase Indication Lamps.
(C) Two Nos. On Load Change Over Switches of each rating 125A, 4P, 415 V (One for EB and DG Set Bye-Pass Arrangement) including providing and fixing Al Busbars of 200 A Capacity (Neutral At Par) as required.
(D) Two Nos. of 4 Module Surge Protection Device (SPD) Type I + II, having 50KA, 10/350 micro seconds neutral to earth at Incomer Side as required.
(E) 12 V Battery Charger consisting of transformer, rectifier, DC/AC Ammeter, DC/AC Volt Meter and charge rate selector switch with position OFF/Trickle/OFF/Boost for charging capacity of 12 Volts lead acid battery (1 No 12 volts, 25 plates 180 AH in two steps i.e. trickle/boost charging), Rheostat etc., as required.
(F) One Set of Selector Swiches for Auto/Manual/Test/Off Operation and One Set of Push Button for Start/Stop/Reset etc.
(G) One Set of 5 mm, 3 LED Display for indicating Performance of DG Set and One Hooter to alarm the abnormality of DG Set.
(H) One Set of 200 Amps Al. Bus Bar with at par neutral bus
(I) PLC System for Operation and Monitoring of 2 Nos. of DG Set including interlinking with DG Controller, Programming, Operation of II Set in case of I Set fails to start and vice versa etc., as required. (One Common PLC will be installed for both AMF Panel)
(J) All accessories such as fuses, auxillary contactors, auxillary switches, timers, MultiCore Control Cabling from DG Set To AMF Panel etc., as required. [Power Cabling Not Included]
ALL AS ABOVE 2 (A) TO 2 (J) | 2 | Job | 3,50,000 ₹7,00,000 | 2,90,000 ₹5,80,000 Lowest | 3,05,000 ₹6,10,000 |
| 3.00Fabrication, SITC of MV Switch Board Non-Essential cum APFC Panel made of 14 SWG CRCA Sheet Steel, dust tight, vermin proof, Totally enclosed, cubicle type, Confirming to IP 42, floor mounting, free standing, extensible on both sides, suitable for indoor operation at 433 V, 3 Phase, 4 Wire, 50 Hz, A.C.System complete with all accessories, interconnection, connection, earthing, painting, cable entry provision, provided with bottom base channel and locking arrangements including grouting etc., as required and comprising of the following: (A) Two Nos. of 250A, 50 KA, 4P MCCBs with Thermal Magnetic Releases for OC/SC/EF Protection as INCOMERS with ON/OFF/TRIP Indication Lamps and Phase Indication Lamps, Multifunction Meter i/c. CTs, Interlocking Facility with Incomers and Buscouplers as required. (B) One No. 250A, 50 KA, 4P MCCB as Bus Coupler with ON/OFF Indication Lamps as required. (C) Two Nos. of 4 Module Surge Protection Device (SPD) Type I + II, having 50KA, 10/350 micro seconds neutral to earth at Incomer Side as required. (D) Two Nos. of 15 KVAR Capacitor bank, including suitable capacity 3 Ph., Delta Connected Super Heavy Duty, MPP Capacitor with Al. Round Enclosure of Voltage Rating 440 V (Minimum) with Copper Wound 7% Detuned Reactors, Capacitor Duty Contactors, 63 A, 3P, 15 KA, MCBs, 10 sqmm Interconnecting PVC Insulated FR Copper Flexi-Wires, Push Button, ON/OFF Indication Lamps. (E) Two No. of 14 Steps APFC Relay with VA Sensors of (250/5) Amps Resin Cast CT at appropriate Transformer's Secondary Circuit i/c supplying, laying/fixing of 7C X 2.5 Sq.mm. PVC insulated PVC sheatherd armourned, copper conductor Control Cabling from Transformer Secondary to APFC Panel (suitable length), providing Auto/Manual Facility as required. (F) Two No. 125 A, 36 KA, 4P MCCBs (D Sine Series of L&T/Equivalent) with Thermal Magnetic Releases for OC/SC/EF Protection with microprocessor based releases as Incomer (For capacitor bank) with CT operated 3 Phase digital protective relay, CT Operated Digital Meter, ON/OFF/TRIP Indication, ON OFF Push Buttons, Phase Indication Lamps etc., as required. (G) Two Nos. 200 A, 36 KA, 4P MCCB (D Sine Series of L&T/Equivalent) as Outgoing with inbuilt O/C and E/F Protection with Microprocessor Based Releases and provided with Resin Cast CTs with Digital Meter and ON/OFF/TRIP Indication Lamps etc., as required. (H) Two Nos. 125 A, 36 KA, 4P MCCB (D Sine Series of L&T/Equivalent) as Outgoing with inbuilt O/C and E/F Protection with Microprocessor Based Releases and provided with Resin Cast CTs with Digital Meter and ON/OFF/TRIP Indication Lamps etc., as required. | ||||||
| 3.10 | (I) Two Nos. 100 A, 36 KA, 4P MCCB (D Sine Series of L&T/Equivalent) as Outgoing with inbuilt O/C and E/F Protection with Microprocessor Based Releases and provided with Resin Cast CTs with Digital Meter and ON/OFF/TRIP Indication Lamps etc., as required.
(J) One Set of 300 Amps Al. Bus Bars with at Par Neutral BUS BARS as required.
(K) All accessories such as fuses, auxillary contactors, auxillary switches, etc. as required.
All Above 3(A) to 3(K) - 1 Job | 1 | Job | 3,50,000 ₹3,50,000 | 70,000 ₹70,000 | 9,500 ₹9,500 Lowest |
| 4.00 | Fabrication and S.I.T.C of 250A Rating, 4 Pole on load Changeover switch in Sheet Steel Enclosure complete with Phase barrier, Handle Assembly having Door Interlock and Padlocking arrangement, Indoor MV Feeder Pillar Panel with door arrangement made out of 3mm thick outer, CRCA sheet steel, dust tight, vermin proof, totally enclosed, cubicle type with top canopy for safety protection Confirming to IP54 stand mounting, free standing, suitable for operation at 433 V, 3 phase, 4 wire, 50 Hz, A.C. Power supply system complete with all accessories, interconnection, connection, earthing, painting, grouting, providing pedastal upto the height of 300MM, Cable Entry provision etc. as required. | 1 | Job | 50,000 ₹50,000 Lowest | 90,000 ₹90,000 | 52,000 ₹52,000 |
| 5.00 | Supply of 4C x 185 Sq.mm, XLPE insulated and PVC sheathed armoured aluminium conductor power cable of 1.1 KV grade conforming to IS 7098 (Part-1) with upto date ammendments etc., complete as required.
(Note: If the manufacturer does not have NABL accredited Laboratory samples from site shall be collected jointly by AAI and the agency and it will be sent to NABL accredited Laboratories / Govt Laboratories / IIT / IISc / IISER / College /University for acceptance Testing as per IS. The contractor will do all Liasoning, Transportation etc. and pay the testing charges. Nothing extra will be paid by AAI. if it is found that the cable supplied is not as per the requirement of IS, The supply will be rejected or recovery shall be made from the bill or any due pending with AAI from any airports) | 1,200 | Mtr | 1,500 ₹18,00,000 Lowest | 1,500 ₹18,00,000 Lowest | 2,150 ₹25,80,000 |
| 6.00 | Supplying and making end termination with brass compression gland and aluminium lugs for 4C x 185 Sq.mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | 14 | Set | 1,000 ₹14,000 Lowest | 1,200 ₹16,800 | 4,550 ₹63,700 |
| 7.00 | Supplying and making end termination with brass compression gland and aluminium lugs for 4C x 16-25 Sq.mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | 2 | Set | 500 ₹1,000 | 1,000 ₹2,000 | 350 ₹700 Lowest |
| 8.00 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3.5C X 185 sq. mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | 2 | Each | 1,000 ₹2,000 Lowest | 4,500 ₹9,000 | 5,820 ₹11,640 |
Tender Value
₹63.8 L
EMD Value
₹1.9 L
Closing Date
10 Jun 2026, 6:00 pmClosed
AGM (E-E)
Office of Engineering Electrical, AAI, Vijayawada Airport, Gannavaram-521102
Provision of Power Supply to DVOR at Vijayawada Airport
2026_AAI_275940_1
Provision of Power Supply to DVOR at Vijayawada Airport
Open Tender
Electrical Works
Works
120 days
AAI, Vijayawada Airport
as per NIT Criteria
11 documents required · 11 mandatory
₹1,180
₹1.9 L
3 Jul 2026
19 May 2026
12 Jun 2026
19 May 2026
10 Jun 2026
19 May 2026
19 May 2026 - 28 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, installation, testing and commissioning of prime rated 30 KVA DG Set along with acoustic enclosure including providing foundation platform as per OEM Design and minor civil works if required, meeting CPCB Pollution Norms of CPCB IV+ as applicable on the Day of submission of Tender and comprising of following: (A) 01 No. Alternator suitable for generating 24 KW/30 KVA at 415 V, 3 Phase, 50 Hz, 0.8 PF, 1500 RPM, Self ventilated, Self regulated and Self excited with brushless type with Class H Insulation etc., conforming to IS 15999 as specified and as required. (B) 01 No. Multi cylinder, 4 Stroke, Turbo charged Diesel Engine developing suitable BHP at 1500 RPM suitable for above mentioned alternator and complete with all accessories such as base frame, AVM Pads, Battery of 12V 180AH, All types of filters (Including Air filter of heavy duty), Coupling, starter, Automatic electronic speed governing mechanism, Compact radiator etc., and conforming to relevant IS with up to date amendments as specified and as required. (C) Integrated microprocessor based generator set control system providing digital voltage regulation, Engine protection, Alternator protection, Isochronous governing switch for AMF Function, Battery monitoring, Operator interface, Communication interface etc., as specified and as required. (D) 1 No. Integral control / Isolator panel made of 2mm thick CRCA Sheet, comprising of DG Controller (as mentioned above), Copper bus bars of capacity not less than 160 Amps with incoming / outgolng terminals, Indicating lamps for 'Load ON' and 'Set running', Instrument fuses duly wired and ferruled, 4P MCCB of 160 Amps 36 KA rating with Overload, Short circuit and Earth fault protections of microprocessor based as required. (E) 1 No. inbuilt Fuel tank of capacity as per OEM Design complete with connecting pipes, valves, fuel level indicators etc., as specified and as required. (F) Customised Compact Modular Type Tested Acoustic Enclosure suitable for the above DG Set to limit the Noise Level to 75 dB (A) at a distance of 1 Mtr., from the Enclosure, made out of CRCA sheet of 1.6 mm thickness for the Outside Cover and Doors and for Inside Cover with 0.8 mm thick perforated GI Sheet, Louvers of thickness 1.6 mm CRCA Sheet for Fresh Air and Hot Air, Powder coated after Seven Tank Process, Neoprene Rubber Gasket and heavy duty SS locks with SS Hinges, Acoustic made up of high quality rock wool/glass wool/ mineral wool as per OEM design, Base Frame of suitable Size Channel, provision to accommodate Batteries, and Support for Silencers, provided with 4 Nos. LED Tube light Fittings of 2 feet and Switches as required. | |||||
| 1.01 | (G) Exhaust gas piping for above DG of suitable dia.welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, bellows, residential silenser, insulation of exhaust system with mineral wool/Rockwool 50 mm thick, wire mesh & aluminium cladding of minimum thickness of 0.6 mm etc., as required meeting CPWD/PCB/AAI Specifications.
All Above 1(A) - 1 (G) | 2 | Job | 100 | ₹200 |
| 2 | Fabrication, SITC of MV Switch Board [AMF] Panel made of 14 SWG CRCA Sheet Steel, dust tight, vermin proof, Totally enclosed, cubicle type, Confirming to IP 42, floor mounting, free standing, extensible on both sides, suitable for indoor operation at 433 V, 3 Phase, 4 Wire, 50 Hz, A.C.System complete with all accessories, interconnection, connection, earthing, painting, cable entry provision, provided with bottom base channel and locking arrangements including grouting etc., as required and comprising of the following:
(A) One No. 160 A, 36KA, 4P, MCCBs with Thermal Magnetic Releases for OC/SC/EF Protection with microprocessor based releases for EB Supply with CT operated 3 Phase digital protective relay, CT Operated Digital Meter, ON/OFF/TRIP Indication and Phase Indication Lamps.
(B) One No. 160 A, 36KA, 4P, MCCBs with Thermal Magnetic Releases for OC/SC/EF Protection with microprocessor based releases for DG Supply with CT operated 3 Phase digital protective relay, CT Operated Digital Meter, ON/OFF/TRIP Indication and Phase Indication Lamps.
(C) Two Nos. On Load Change Over Switches of each rating 125A, 4P, 415 V (One for EB and DG Set Bye-Pass Arrangement) including providing and fixing Al Busbars of 200 A Capacity (Neutral At Par) as required.
(D) Two Nos. of 4 Module Surge Protection Device (SPD) Type I + II, having 50KA, 10/350 micro seconds neutral to earth at Incomer Side as required.
(E) 12 V Battery Charger consisting of transformer, rectifier, DC/AC Ammeter, DC/AC Volt Meter and charge rate selector switch with position OFF/Trickle/OFF/Boost for charging capacity of 12 Volts lead acid battery (1 No 12 volts, 25 plates 180 AH in two steps i.e. trickle/boost charging), Rheostat etc., as required.
(F) One Set of Selector Swiches for Auto/Manual/Test/Off Operation and One Set of Push Button for Start/Stop/Reset etc.
(G) One Set of 5 mm, 3 LED Display for indicating Performance of DG Set and One Hooter to alarm the abnormality of DG Set.
(H) One Set of 200 Amps Al. Bus Bar with at par neutral bus
(I) PLC System for Operation and Monitoring of 2 Nos. of DG Set including interlinking with DG Controller, Programming, Operation of II Set in case of I Set fails to start and vice versa etc., as required. (One Common PLC will be installed for both AMF Panel)
(J) All accessories such as fuses, auxillary contactors, auxillary switches, timers, MultiCore Control Cabling from DG Set To AMF Panel etc., as required. [Power Cabling Not Included]
ALL AS ABOVE 2 (A) TO 2 (J) | 2 | Job | 100 | ₹200 |
| 3Fabrication, SITC of MV Switch Board Non-Essential cum APFC Panel made of 14 SWG CRCA Sheet Steel, dust tight, vermin proof, Totally enclosed, cubicle type, Confirming to IP 42, floor mounting, free standing, extensible on both sides, suitable for indoor operation at 433 V, 3 Phase, 4 Wire, 50 Hz, A.C.System complete with all accessories, interconnection, connection, earthing, painting, cable entry provision, provided with bottom base channel and locking arrangements including grouting etc., as required and comprising of the following: (A) Two Nos. of 250A, 50 KA, 4P MCCBs with Thermal Magnetic Releases for OC/SC/EF Protection as INCOMERS with ON/OFF/TRIP Indication Lamps and Phase Indication Lamps, Multifunction Meter i/c. CTs, Interlocking Facility with Incomers and Buscouplers as required. (B) One No. 250A, 50 KA, 4P MCCB as Bus Coupler with ON/OFF Indication Lamps as required. (C) Two Nos. of 4 Module Surge Protection Device (SPD) Type I + II, having 50KA, 10/350 micro seconds neutral to earth at Incomer Side as required. (D) Two Nos. of 15 KVAR Capacitor bank, including suitable capacity 3 Ph., Delta Connected Super Heavy Duty, MPP Capacitor with Al. Round Enclosure of Voltage Rating 440 V (Minimum) with Copper Wound 7% Detuned Reactors, Capacitor Duty Contactors, 63 A, 3P, 15 KA, MCBs, 10 sqmm Interconnecting PVC Insulated FR Copper Flexi-Wires, Push Button, ON/OFF Indication Lamps. (E) Two No. of 14 Steps APFC Relay with VA Sensors of (250/5) Amps Resin Cast CT at appropriate Transformer's Secondary Circuit i/c supplying, laying/fixing of 7C X 2.5 Sq.mm. PVC insulated PVC sheatherd armourned, copper conductor Control Cabling from Transformer Secondary to APFC Panel (suitable length), providing Auto/Manual Facility as required. (F) Two No. 125 A, 36 KA, 4P MCCBs (D Sine Series of L&T/Equivalent) with Thermal Magnetic Releases for OC/SC/EF Protection with microprocessor based releases as Incomer (For capacitor bank) with CT operated 3 Phase digital protective relay, CT Operated Digital Meter, ON/OFF/TRIP Indication, ON OFF Push Buttons, Phase Indication Lamps etc., as required. (G) Two Nos. 200 A, 36 KA, 4P MCCB (D Sine Series of L&T/Equivalent) as Outgoing with inbuilt O/C and E/F Protection with Microprocessor Based Releases and provided with Resin Cast CTs with Digital Meter and ON/OFF/TRIP Indication Lamps etc., as required. (H) Two Nos. 125 A, 36 KA, 4P MCCB (D Sine Series of L&T/Equivalent) as Outgoing with inbuilt O/C and E/F Protection with Microprocessor Based Releases and provided with Resin Cast CTs with Digital Meter and ON/OFF/TRIP Indication Lamps etc., as required. | |||||
| 3.1 | (I) Two Nos. 100 A, 36 KA, 4P MCCB (D Sine Series of L&T/Equivalent) as Outgoing with inbuilt O/C and E/F Protection with Microprocessor Based Releases and provided with Resin Cast CTs with Digital Meter and ON/OFF/TRIP Indication Lamps etc., as required.
(J) One Set of 300 Amps Al. Bus Bars with at Par Neutral BUS BARS as required.
(K) All accessories such as fuses, auxillary contactors, auxillary switches, etc. as required.
All Above 3(A) to 3(K) - 1 Job | 1 | Job | 100 | ₹100 |
| 4 | Fabrication and S.I.T.C of 250A Rating, 4 Pole on load Changeover switch in Sheet Steel Enclosure complete with Phase barrier, Handle Assembly having Door Interlock and Padlocking arrangement, Indoor MV Feeder Pillar Panel with door arrangement made out of 3mm thick outer, CRCA sheet steel, dust tight, vermin proof, totally enclosed, cubicle type with top canopy for safety protection Confirming to IP54 stand mounting, free standing, suitable for operation at 433 V, 3 phase, 4 wire, 50 Hz, A.C. Power supply system complete with all accessories, interconnection, connection, earthing, painting, grouting, providing pedastal upto the height of 300MM, Cable Entry provision etc. as required. | 1 | Job | 100 | ₹100 |
| 5 | Supply of 4C x 185 Sq.mm, XLPE insulated and PVC sheathed armoured aluminium conductor power cable of 1.1 KV grade conforming to IS 7098 (Part-1) with upto date ammendments etc., complete as required.
(Note: If the manufacturer does not have NABL accredited Laboratory samples from site shall be collected jointly by AAI and the agency and it will be sent to NABL accredited Laboratories / Govt Laboratories / IIT / IISc / IISER / College /University for acceptance Testing as per IS. The contractor will do all Liasoning, Transportation etc. and pay the testing charges. Nothing extra will be paid by AAI. if it is found that the cable supplied is not as per the requirement of IS, The supply will be rejected or recovery shall be made from the bill or any due pending with AAI from any airports) | 1,200 | Mtr | 10 | ₹12,000 |
| 6 | Supplying and making end termination with brass compression gland and aluminium lugs for 4C x 185 Sq.mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | 14 | Set | 10 | ₹140 |
| 7 | Supplying and making end termination with brass compression gland and aluminium lugs for 4C x 16-25 Sq.mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | 2 | Set | 10 | ₹20 |
| 8 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3.5C X 185 sq. mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | 2 | Each | 10 | ₹20 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.65 MB
TENDERDOCUMENT.pdf
Tender Documents • 5.66 MB
BOQ_324597.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].