Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance NANDANI VIHAR ADHOIWALA DEHRADUN | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance GRAM SIRSU PO FATEHPUR DUGADDA PAURI GARHWAL | PAURI GARHWAL | UTTARAKHAND | 246001 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹91,800
Closing Date
8 Feb 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
EXECUTIVE ENGINEER, MAINTENANCE DIVISION, UTTARAKHAND JAL SANSTHAN, KOTDWAR
Retrofitting and Reaugmentation work under AMDANDA PUMPING W/S Scheme under RIKHANIKHAL Block Kotdwar
2023_UKJS_54351_1
3479/Nivida Suchana/2022-23 dated 20.01.2023
Open Tender
Civil Works - Water Works
Item Wise
180 days
Kotdwar
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Executive Engineer, UJS
₹91,800
Kotdwar
10 Feb 2023
25 Jan 2023
10 Feb 2023
25 Jan 2023
8 Feb 2023
25 Jan 2023
28 Jan 2023
CIVIL WORK
Supply of all materials, labour, T&P etc and construction of R.C.C. CWR of following capacities ( in kiloliters ) with M.S. ladder outside & inside of the tank, M.S. M.H. cover with locking arrangement, supply and fixiing of outlet, inlet, over flow and wash out pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60 M wide apron, painting on tank body vertical pipes, ladder, M.S. M.H. cover etc. complete with approved water proofing (apex) / enamal paint, testing, filling water for testing purpose etc. 5.0 KL
Supply and installation of Bucket Type Chlorinator of 25 L Capacity on the top of Service Reservoirs
Supply, Carting (site store to trench), lowering them into trenches, laying true to alignment and gradient, laying and jointing of pipe line by welding for making up lengths as required for proper completion of work of following grade & sizes ((Excluding cartage from Road Head to site store.) MSERW Pipe Yst 210 50 mm Dia 4.8 mm thick
For washout & over flow 50 mm Dia 4.8mm thick
Providing of all materials, Carting from site store to site of work, Laying & Jointing of G.I. medium screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc) in trenches with its cutting, threading and testing of pipe line etc complete. 15 mm dia
20 mm dia
25 mm dia.
32 mm dia
40 mm dia.
50 mm dia.
Excavation of earth for pipeline trench in following strata lift upto 1.5 m lead upto 30 m including refilling, watering, ramming of excavated earth into the trenches and removal of surplus earth upto a distance of 60 m from trenches including supply of labour, T & P etc.all complete assuming that 90% pipe line is laid in trenches, it is estimated that 95% excavation will be in soil mixed with shingle, bajari and boulders and rest 5% will be in medium rock (trench 0.60 m wide and 0.60 m deep) Soil Mixed with boulder and bajari
Medium Rock
Painting of MSERW Pipes with 2 coats of approved quality. (Anti-Corrosive paint over one coat of Primer) (dia. of pipe in mm) 50 mm Dia 4.8 mm thick
Supply of all materials, labours, T&P etc and construct RCC 1:1.5 :3 anchor / thrust blocks as per design complete
M.S. Iron work in anchor / thrust blocks .
Supply and fixing of the following fittings including cartage of materials, labour, T & P etc complete G.M Gate Valve IS 778 Vertical Check Class -1 40 mm
Constructing masonry Chamber 60 x 60 x 75cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse) for sluice/air valve, with C.I. surface box 100 mm. as per standard design.
Dismantling of following existing CC road pavement for laying different sizes of pipes, stacking the serviceable materials and disposal of waste materials upto a distance of 30 m including supply of materials, labour, T&P etc. complete CC Road
Supply of all materials, labour, T & P etc and construction of BPT as per type, design (Size :- 1.0 m x 1.0 m x 1.0 m)
Supply and fixing of the following fittings including cartage of materials, labour, T & P etc complete G.M Gate Valve IS 778 Vertical Check Class -1 32 mm
Material for House connections Brass ferrul 15 mm with C.I. mouth cover
Construction charge to road cutting of following road pavement (which was dismantled during execution of works) after laying of different sizes of pipes and disposal of debris if any including supply of all materials labour, t&p etc. complete. PCC 1:2:4 including supply of all materials, labour, T&P etc. complete
Excavation for foundation in Soil mixed with boulders for protection work
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P etc. complete in Intake work, along the Rising main, Supply/feeder main, distribution system, storage reservior etc
Random Rubble Stone Masonry laid Dry, in breast walls, retaining walls, etc. including supply of all material, labour, T&P etc. complete in Intake work, along the Rising main, Supply/feeder main, distribution system, storage reservior etc
PCC 1:4:8 including supply of all materials, labour, T&P etc. complete
Repair of Top CWR (17.5 KL) (Concreting inside with wiremess, Fittings, Valve etc) as per attached detail
Repair of CWR (7.5 KL) (Concreting inside with wiremess, Fittings, Valve etc) as per attached detail
Repair of Pump House (as per attached detail)
Approch Road At Top CWR (as per attached detail)
Cartage of Material
E&M Work
SITC of CENTRIFUGAL SOLAR PUMP, Head - 110 M, Flow - 125 LPM with suitable Motor , 1440 RPM including Supply of fully automatic auto transformer type starter suitable for above motors having airbreak contactors, electroni timer, thermal over load relay, adequate size Aluminum bus bars, copper wound auto transformer and dulywired by copper leads/ wire, lugs, ON/OFF andreset switches and indicators etc. complete in all respects Supply of main piping and valves comprising of the following 65 mm dia CI D/F sluice valve PN-1.0-02 nos. 65 mm dia CS D/F sluice valve class 300 ASA-03 Nos. 65 mm dia CI D/F reflex valve 300 ASA-02 nos.
Main LT Panel at MPS Three (3) phase and neutral 415V, 4 wire, 50Hz Indoor type, wall mounting, with bottom cable entry, Single Front door type made of 2 mm thick MS sheet with enclosure door of 16 SWG MS sheet (minimum), with IP-42 degree of protection after seven tank Process and painting with Epoxy Powder coating and equipped with following switchgears/ fixtures etc and necessary side supports to fix the panel on the wall on four sides. The panel shall have Short circuit withstanding capacity of 31.5 kA for 1 sec equipped with the switch gears as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certification only.
1100 V grade XLPE insulated PVC sheathed GI flat armoured 'Aluminium conductor' power cable (A2XFY) of the following sizes as per enclosed detailed specifications and IS 7098 (Part-1). 4C x 16 Sq.mm. (A2XFY)
1100 V grade XLPE insulated PVC sheathed GI round wire armoured 'Copper conductor' power cable of the following sizes as per enclosed detailed specifications and IS 7098 (Part-1). 3C x 4 Sq.mm. (2XWY)
3C x 2.5 Sq.mm. (2XWY)
Cable dead end termination kit with double compression brass glands, Aluminium lugs and tape as required for 1100 V grade XLPE insulated PVC sheathed GI flat armoured Aluminium conductor power cable of the following size 4C x 16 Sq.mm.
Cable dead end termination kit with double compression brass glands, Copper lugs and tape as required for 1100 V grade XLPE insulated PVC sheathed GI round wire armoured Copper conductor power cable of the following size : 3C x 4 Sq.mm.
3C x 2.5 Sq.mm.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and erecting approved make, standalone solar LED street light system with tubular pole, polyacryline PV panel solar tubular battery. Battery box pole and mechanical hardware with 30 watt LED lamp
Wall Mounting Pin type holder for 1x12 W LED Bulb
20W LED Tube Light for Indoor Lighting
12 W LED Bulb for Indoor Lighting
4 way Modular Type Switch Board for control of Indoor Lighting
Wall Mounting Double Door 6 way SPN Lighting Ditribution Board including 1 no. 32A, DP, 10kA MCB (1No) and 16/10A, SP, 10kA, MCB (6Nos) for control of Indoor Lighting
6 Amp 3/5 Pin Socket for Indoor Lighting
6/16 Amp, 3/5 pin Switch Socket with 16 A control Switch for Indoor Lighting
6-10 A Modular Type Control Switch for Indoor Lighting for control of Indoor Lighting
300 MM Sweep, 950rpm Single Phase Exhaust Fan for Indoor Lighting
Electric Ceiling Fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete as required confirming to IS : 374/1979 with upto date ammendments. (Energy Saver 60 W - 1200 mm sweep)
Wiring with 1.1 KV graded FR PVC insulated ISI marked standard copper conductor wire in existing pipe of following sizes : 4 sq. mm PVC Insulated Cu wire for internal wiring of buildings
2.5 sq. mm PVC Insulated Cu wire for internal wiring of buildings
1.5 sq. mm PVC Insulated Cu wire for internal wiring of buildings
H.G. Conduit 20 mm for building wiring
75 mm dia PVC Pipe with couplers and Bends complete in all respect.
150mm wide, 35mm high, 2mm thick, GI perforated cable tray
12.5 Kg Carbon di oxide type portable fire extinguisher mounted on stands with wheels at bottom complete with fill.
6 Kg Capacity,wall mounted type foam soda acid extinguisher.
DIESEL GENERATOR SET 15 KVA, 1500 RPM, 0.8 Pf, 415V, 3 phase, 50Hz, air cooled, sound proof Diesel Generaor set complete with Battery & Battery charger, exhaust system with silencer and with acoustic enclosure/canopy alongwith complete control cabling between DG sets / its auxiliaries, LT compartment with 32 Amp rating MCCB for soucing of power to Main LT panel including 1 no. 990 litre capacity day tank to replenish HSD in the main Tank and complete with piping between oil day tank and DG set, exhaust pipes above DG set as per applicable rules/ statutory requirement including all necessary civil works i.e steel Structural work for DG set, Exhaust systems etc shall form part of the supply / contract.
SOLAR ROOF TOP PLANT 12 x 330 W, 72 cell Poly crystalline PV modules of efficiency >17% make aproved under ALMM list of MNRE, 4 kW Inverter make Growatt, Delta, Havells, Warree, equivalent make AC & DC cable with MC4 connectors, eathing & lightning protection, ACDB & DCDB with surge protection, GS structure of adequate height. (Net-metering / Zero export as per state regulation/ policy)
Provision of Sign Board
Provision of Material Testing
B P ENTERPRISES
M/s LAXMAN SINGH NEGI
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .