Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹39.8 L+₹59,847.13 (1.53%)Rejected-AOC PLOT NO 52 SIDDARTH PARK BEHIND ICE FACTORY RAVALWADI BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹56.1 L+₹16.9 L (43.1%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
₹41.3 L
EMD Value
₹82,500
Closing Date
28 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Naliya NO 01
GE Air Force Station Naliya
CONSTRUCTION OF DEFICIENT ACCN AT SMC ALONWITH CERTAIN CAP AND 01 SPL REPAIR WORK AT AF STN NALIYA
2021_MES_409089_1
8731/E8
Open Tender
Civil Works
Item Rate
180 days
Naliya
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE AF Naliya No.01
₹82,500
Yes
23 Jun 2021
2 Jan 2021
30 Jan 2021
2 Jan 2021
28 Jan 2021
16 Jan 2021
60 days
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation,for laying of cable/ erection of pole/stay pit excvation etc and getting out in any type of soil complete all as specified and as directed.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 Cm in any type of soil complete all as specified and as directed.
Removing excavated soils to outside MD land at a level not exceeding 1.5 M above the starting point complete all as specified and as directed.
M & L for PCC 1:4:8 Type D2 (using 40 mm graded stone aggregsate) as in foundation and filling and mass concrete etc. complete all as specified and as directed.
Use and waste of form work to sides of concrete foundations,footings, base of columns, raft and raft beams, side and soffits of foundations,plinth beams and similar work vertical or to batter complete all as specified and as directed.
Used and waste of form work to side of pillars, posts struts, piers, columns and stanchions complete all as specified and as directed.
Use and waste of form work to sides and soffits of floor or roof beams haunchings, girders, bressummers, lintels, bands,chajjas, cantilevers, shelves including sup-ports overhangs, etc also splays between floor and beams etc. complete all as specified and as directed.
Use and waste of form work to sides and soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works, not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed.
Use and waste of form work to edges of concrete flats, treads breaks in floors, floor and roofs and similar work, exceeding 10 Cm but not exceeding 20 Cm wide complete all as specified and as directed.
M & L for RCC 1:1½:3 type A-1 (20mm graded stone aggregate) as in foundation, footings, foundation beam,plinth beams and bases of columns basement slabs, and mass concrete complete all as specified and as directed.
M & L for RCC 1:1½:3 type A-1 (20mm graded stone aggregate) as in columns pillers, piers, posts and struts complete all as specified and as directed.
M&L for RCC 1:1½:3 type A-1 (20mm graded stone aggregate) as in beams, cantilevers roof beam,plinth beam , bressummers, lintels over 1.5 m span complete all as specifiedand as directed.
M&L for 1:1½:3 type A-1 (20mm graded stone aggregate) as in chajjas etc. complete all as specifiedand as directed.
M & L for RCC 1:1½:3 type A-1 (20mm graded stone aggregate) as in slabs supported on walls beam and colums in floors, roofs, landind, deck slabs and shelves etc complete all as specifiedand as directed.
M&L for RCC 1:1½:3 type A-1 (20mm graded stone aggregate) as in columns,beam, pillars, piers, posts and struts complete all as specified and as directed.
M&L for steel reinforcement 10mm dia and over, TMT bars, cut to length, bent to shape required including cranking bending spirally for hooping for columns hooking and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per item No.17.00 above but 6 to 8mm dia
All as per item No. 17.00 above but 5mm dia and over upto and including 10mm dia as in strirrups
M&L for precast cement concrete block masonary walling with solid blocks of PCC (1:5:8) using 20mm graded stone aggregates, exc 10cm in width and sett in cement plaster (1:6) complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for broken stone hardcore of gauge not exceeding 63mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 75 mm thick PCC 1:4:8 Type D2 ( using 40 mm graded stone aggregate) as in sub base to floors complete all as specified and as directed.
M&L for 100mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection / hard standing etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and as directed.
M&L for 75mm thik cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for 40mm thick cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in flooring / levelling course & finishing the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for Vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finish complete all as specified and as directed.
All as per item No.28.00 above but vitrified ceramic tile as in vertical surfaces including 10 mm thick rendering as backing coat on fair faces of brick work or concrete surface in CM 1:4 complete all as specified and as directed.
M&L for 10mm thick rendering on fair faces of brick work or concrete surface in CM 1:6 finished even and smooth with out uing extra cement complete all as specified and as directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete cement mortar 1:4, finished fair and even using extra cement including mixing of water proofing compound in proportion as per manufacture's instructions complete all as specified and directed. Note : Water proofing compound shall be measured and paid for separately under relevant item.
M&L for rendering 5mm thick in cement mortar (1:3) and finishing the surface even and smooth without using extra cement as in ceiling, soffits of slab complete all as specified and directed.
Supply only Integral water proofing compound ISI marked complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls, and applying two coats of oil bound distemper over a coat of primer complete all as speified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of camouflage painting with exterior emulsion paint over a coat of primer etc complete all as per specified and as directed.
M&L for preparing newly prepared surfaces of ceilings and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of old plastered or unplastered surfaces of walls and applying two coats of white wash complete all as specified and as directed.
S&F in position Aluminium powder coated (minimum 50 micron thickness) door shutter with frame, partly glazed with 5mm thick tinted glass and partly panelled with 9mm thick both side decorative prelaminated particle board exterior grade including rubber bead joining cleat for fixing, aluminium handle 150 mm size and tower bolt 200 mm size, double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing brass pivot, Mortice lock vertical type of mild steel 4 levers of size 100mm etc all as mentioned here in below, complete all as specified and as directed :- (a) Frame (top & side) section-101.60 x 44.75 x 2.4 mm (Section No 14021) (b) Vertical Members of shutter Section-85.00 x 44.45 x 2.00 mm (Section No 19560) (c) Top Members of shutter Section - 83.50 x 44.45 x 2.00 mm (Section No 19581) (d) Lock rail (Middle member) of shutter Section - 150.00 x 44.45 x 3.00 mm (Section No 19596) (e) Bottom Members of shutter Section -150.00 x 44.45 x 3.10 mm (Section No 19584) (f) Glazing clip for securing glass - 0.80 mm thick (Section No 19370). Note: Section No given above are of make Jindal, Contractor may use similar section of other make. Make: Jindal/INDAL/Hindalco
Supply & fix aluminium powder coated (minimum 50 micron thickness ) ventilator shutters with frame (aluminium section weighing 0.55Kg/m), fixed with out sash bars, openable type (Top hung) and glazing complete with 5mm thick coloured/tinted sheet glass with necessary clips, hinges, aluminium(anodised) peg stay 30cm long-01 No. with aluminium (anodised) grill made out of 7mm wide flat, square, rectangular or similar section, fixed with channel of size 38mm x 12 mm x 13mm (Section 8778) complete all as per manufacturer's catalogue 7 specifications complete all as specified and as directed Make: Aluminium Sections powder coated : Jindal/INDAL/Hindal.
S&F aluminum powder coated (minimum 50 micron thickness ) frame fixed partition with 12 mm thick prelaminted particle board exterior grade,prelaminated one side with decorative choice lamination and other side balancing white lamination for bottom panels and top panels with 6mm thick tinted glass and frame work shall be of panel not less than 0.8mm thick (section to be used for bottom rail,middle rail and other members shall be of 150 x44x3 mm,125x44x3 mm and 44x44x3 mm respectively) including joining cleats for fixing,cleats,rubber beading and aluminium beading,padding accessories as required complete all as specified and as directed.
S&F aluminium powder coated (minimum 50 micron thickness), three track sliding window frame of section size 92.00x31.75x1.3mm comprising of one No. of fly proof shutter and two Nos of glazed shutter frames of section size 40x18x1.55mm thick with necessary joining cleats, glazing clips, rubber gasket, anodised aluminium snap beading and connected locking arrangement all as specified and directed. Notes : (i) Glass filling in panels of windows and aluminium wire mesh/wire cloth shall be deemed to be included in the quoted rate for the item (ii) Aluminium alloy wire cloth in panels of wire gauzed shutter shall be 0.45 mm nominal dia of wire and average width of aperture 1.40 mm, fixed with aluminium wire staples (iii) Glass filling in panels of glazed shutter shall be 4 mm thick tinted sheet glass of approved make and shade/tint Make of Aluminium Sections: Jindal/ INDAL/Hidalco)
S&F powder coated (minimum 50 micron thickness) aluminium three track sliding window comprising of one fly proof shutter and two glazed shutters with window frames of size 92mmx31.75x1.50 mm thick and shutter frames of size 40mmx18mmx1.55 mm thick with necessary joining cleats,glazing clips,gasket,anodised aluminium snap beading and connected locking arrangement and with aluminium deco grill DG/01 7X4.5 MM thick,fixed with channel of size 38mmx12mmx13mm complete. Notes : (i) Glass filling in panels of windows and aluminium wire mesh/wire cloth shall be deemed to be included in the quoted rate for the item (ii) Aluminium alloy wire cloth in panels of wire gauzed shutter shall be 0.45 mm nominal dia of wire and average width of aperture 1.40 mm, fixed with aluminium wire staples (iii) Glass filling in panels of glazed shutter shall be 5mm thick tinted sheet glass of approved make and shade/tint Make of Aluminium Sections: Jindal/ INDAL/Hidalco)
S&F anodised aluminium grill made out of 7mmx4.5mm wide flat, square, ractangular or similar section, fixed with channel of size 38mmx12mmx13mm (Section 8778) complete all as specified and as directed, Make:- DECO GRILL No. DG 102 with aperture - 80mm / Any E-in-c's approved make as approved by GE.
M&L for 2nd class hard wood, plain straight, solid chawkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and as directed.
S&F plain framed factory made panelled shutter 35mm thick 2nd class HW rail and style(two panel) with lock raid and panel of 2mm BWP commercial ply or 12mm vencered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003(part I), Kiln seasoned and chemically preasure treated complete all as specified and as directed.
S&F 35 mm thick 2nd class HW, glazed and skeleton shutters, open rebated & prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass,gauze etc complete all as specified and as directed.
S&F 100mm long butt hinges medium weight cold rolled mild steel & fixed to chowkats complete all as specified and as directed.
S&F aluminium anodised, barrel tower bolts of extruded section with length of bolt 200 mm and fixed complete all as specified and as directed
S&F extruded aluminium alloy handles, fabricated type, anodised of size 150 mm complete all as specified and as directed.
S&F 250mm long aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed
S&F extruded aluminium alloy,anodised, sliding door bolt 300 mm in length with hasp, staple (bolt type )and fixing bolts and sliding bolts of extruded sections complete all as specified and as directed.
S&F 140mm floor door stopper of aluminium alloy body and tounge, anodised, with hard drawn steel spring ,fixed in floor complete as all as specified and as directed.
M&L preparation of new painted wooden surfaces of any description exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for machine cut kota stone slab in patch work 20-25 mm thick over cement screed bed 15mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match with the shade of slab including grinding, rubbing and polishing, single piece of stone on steps complete all as specified and as directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick including and over cement screed bed in cement mortar 15 mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including gjrinding, rubbing and polishing as in floor finishes complete all as specified and as directed.
M&L for factory made machine pressed precast concrete, rubber moulded, interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 grade fixed with grey cement and pigment including and over 50mm thick sand cushioning complete all as specified and as directed.
M&L for water proofing treatment on top of RCC roof slab by providing 40mm thick cement concrete (1:2:4) type B-0 (using 12.50mm graded stone aggregate) laid on roof in adequate slope as levelling course, 15 mm thick plastering in cement mortar 1:3 finished even & smooth with water proofing compound mixed as per manuracturers instructions on top of levelling course, preparing & cleaning of fully dried cement plastered surface and Applying one coat of cold bituminous primer to the plastered surface @ 1.50 Kg per sqm conforming to IS 3384-1986 and laying a layer of APP modified water proofing membrane with non woven polyster reinforcement/ mat not less than 3mm thick having weight not less than 3.5 kg/sqm over a coat of bituminous filler/ primer as specified above conforming to IS 3384-1986 through approved applicator all as per manufacturer's instructions complete all as specified and as directed.. Note:- Application of polymeric membrane shall be by torch application. The over lap shall be 100 mm on transverse direction & 75 mm on longitudinal direction.
Taking down/scraping out existing old tarfelt bituminous compound including sweeping, cleaning, washing down to remove dust etc and removing debris to a distance not exceeding 250m complete all as specified and as directed.
Excavation in post holes (or similar holes) each not exceeding 0.5 Cum, getting out in type of soil, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed.
M&L for PCC 1:2:4 type B2 (40mm gradedstone aggregate) as in foundation complete all as specified and as directed.
S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats,gusset plates,wind ties etc of Fe410- W(GdeE-250) quality-B complete all as specified and as directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut not exceeding 5cm long, diameter of neck 11 to 15 mm complete all as specified and as directed.
S&F steel work in tubular trusses 80 mm dia medium class including special shaped washer etc.complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade st 240 complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based trapizoidal shape steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint on new steel surface over a coat of red oxide including preparation of surface of any description over 10 cm width or girth complete all as specified and as directed.
M&L for preparation of old painted surfaces of steel of any description and in any position exceeding 10cm width or girth not otherwise described, and applying two coats of synthetic enamel paint over a coat of zinc chrome primer, complete including necessary scaffolding arrangement as required at site complete all as specified and as directed
M&L for concrete bed to drain pipes of 150 mm bore including packing under and haunching against the sides of pipes in plain cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregates) complete all as specified and directed.
M&L for SGSW drain pipes grade 'A' 150 mm bore laid in trenches and jointed on concrete bed testing after laying of pipe complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-1 (Using 20mm graded stone aggregates) as in incoping, benching channel to manholes etc complete all as specified and as directed.
M&L for precast cement concrete 1:2:4 type B-1 (using 20mm graded aggregate) as in manhole cover slabs, chullah hoodes,chajjas,water troughs etc and set in CM 1:4 complete all as specified and as directed.
M&L for RCC hume pipe septic tank for 10 users on site, design to carry sewage and sludge and sullage water,including necessary excavtion in any type of soil to required depth as required, providing PCC 1:4:8 below foundation, vent shaft,connection etc. complete all as specifed and as dircted.
Taking down cement plster of any description including raking out joints, hacking for key scrubbing down with water etc. and removing rubbish to outside MD land complete all as specified and as directed.
Demolition of cement concrete unreinforced as in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and as directed.
M & L for complete removal of old existing treatment including, washing rubbing down and stopping of existing painting surfaces and appying two coats of oil bound distemper over one coat of primer over two coats wall care putty complete all as specified and as directed.
M&L for preparing newly plastered surfaces of walls etc and applying three coats of white wash complete all as specified and as directed.
M&L for preparing newly plastered surfaces of walls and applying two coats of exterior cement base paint over one coat of primer complete all as specified and as directed.
S&F 15mm bore galvanised iron steel tube, ISI marked medum grade including all fittings like socket /union/ Tee/ Reducer Nipple etc and fixed complete to walls and ceiling etc (concealed) complete all as specified and as directed.
All as per item No.79.00 above but 20mm bore
All as per item No. 79.00 above but 25mm bore fixed on walls/ceilings or laid in trenches
All as per item No.79.00 above but 50mm bore fixed on walls/ceilings or laid in trenches, under roads in drains, fixed to poles/walls with required size flat iron clamp bolts, nuts and washers, pipes complete all as specified and as directed.
S&F 110mm dia PVC (SWR) plain bend (any redius ) complete all as specified and as directed.
S&F 110mm dia PVC (SWR) pipe single socket in any length with rubber ring joint, fixed to walls complete all as specified and as directed.
S&F 110mm dia PVC (SWR) bend (any redius) with access doors complete all as specified and as directed.
S&F PVC (SWR) 'T' with equal or un-equal offsets complete all as specified and as directed.
S&F 85mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F 15mm bore bib taps, cast copper alloy with chromium plated fancy type, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F 15mm bore dia angular/stop valves cast copper alloy with chromium plated, fancy type with long shank and cup concealed type screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F stop valves 25 mm dia cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and as directed.
S&F pillar taps,cast copper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, fancy type screwed for iron pipe, 15mm bore and fixed in repair comoplete all as specified and as directed.
S&F in repair, Vitreous China wash down water closet pan (pedestal pattern) overflow pipes for flushing cistern including jointing to socket or flushing rim and connecting pipe to union of flushing cistern complete all as specified and as directed.
S&F in repairs, 10 litre capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet ball valve, float and handle including brackets and waste pipe complete all as specified and as directed.
S&F Vitreous china wash hand basin, white size 580 x 450mm size (Oval type) including cutting for and pinning in ends of brackets or erecting stand including brackets including fixing of flush pipe and fixed in repair complete all as specified and as directed.
S&F in repair vitreous china wash basin, white flat back, size 450x300mm including brackets, cutting for and pinning in ends of brackets or erecting stand including 15mm bore, pillar tap fancy type, cast copper alloy, with capstan heads, chromium plated, PVC connection 15mm dia 45cm long and 32mm dia PVC waste pipe and CP coupling complete all as specified and as directed.
S&F of 32mm dia waist coupling of PTMT (half or full thread) minimum weight 45gm to 60gm complete all as specified and as directed.
S&F grating doom 100mm dia of PTMT (minimum weight 25gm) complete all as specified and as directed.
S&F towel rail of 60mm long of PTMT fix with and including chromium plated brass screw and wooden / plastic plate (minimum weight 190gm) complete all as specified and as directed.
S&F PVC connection pipe 15mm dia of length 450mm with PTMT nuts and washers complete all as specified and as directed.
S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe including PVC pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for anodised aluminium snap grid frame work of size 605mm x 605mm for flase ceiling with 12 mm thick Perforated particle board for insulation and accoustic purposes of size 60x60cm, fixed in ceiling,flat or sloping on snap grid including providing hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including chalk whiting on ceiling surfaces, preparation and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with MS square tube and edges will be painted to match with printed sheet fixing in opening as per specification and drawing etc as shown in SSR complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30mm (style) consisting of frame made out of MS tube for top & bottom rails MS frame shall be coered with heat moulded wood grain printed PVC sheet used 5mm thick x 15mm wide PVC sheet beading sued inside stiles and rails and decorative PVC beading of 10mm x 10mm (90°) used instead of exposed portion of PVC sheet beading panelling of wood grain printed PVC sheets to be fitted in the MS frame welded sealed to the stiles and rails with suitable PVC sheet beading and complete all as specifed and as directed.
S&F 100mm long, butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and as directed.
S&F 150mm long Aluminium, anodised barrel tower bolt of extruded section complete all as specified and as directed.
S&F aluminium, anodised, barrel tower bolt of extruded section and fixed, 150 mm size complete all as specified and as directed.
S&F 100mm Aluminium locking bolts anodised, with bolt not less than 10mm dia complete all as specified and as directed.
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
M&L for Non skid Ceramic tiles 7 to 8 mm thick (square / rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in vertical surface as skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 as in backing coat complete all as specified and as directed.
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular), area of each tile exceeding 0.18sqm but not exceeding 0.38sqm as in floors etc.set and jointed in neat cement slurry and pointed in coloured cement to match over and including screed bed 15 mm thick in CM 1:6 complete all as specified and as directed.
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.38sqm on vertical surfaces such as skirting / dado etc.set and jointed in neat cement slurry and pointed in coloured cement to match including over and including backing coat 10 mm in CM 1:4 complete all as specified and as directed.
M&L for glazed coloured ceramic tiles 350x250x7mm thick as in dado and skirting etc. set and jointed in neat cement slurry and pointed to match over and including backing coat 10 mm in CM 1:4 complete all as specified and as directed.
M&L for moorum filling in floors or pavings, laid in layers not exceeding 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed
M&L for 100 mm thik Cement concrete type B-2,1:2:4 (using 40 mm graded stone aggregate) as in floor finishes compete all as specified and as directed.
S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for ironpipe and fixed complete all as specified and as directed.
All as per Item No. 117.00 above but for 25 mm dia
S&F Brass chromium plated shower rose 125mm size complete all as specified and as directed.
Demolition Brickwork or stone/boulder/PCC block masonry, built in lime/cement mortar including all quions, arches, pillars etc but excluding ashlar facing dressed stonework and precast concrete article complete all as specified and as directed.
S&F 1000Ltr Rotational moulded polyethylene water storage tanks cylindrical vertical with closed top double layered hoisted and fixed in position including all fittings complete all as specified and as directed.
All as per item No. 121.00 above but 500ltr water tanks
M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregates) as in mounting base to water tank etc, 10cm high complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition complete all as specified and as directed.
M&L for Granite 16 to 18 mm thick (of any tpe) work (table rubbed and polished) as in steps, jambs, pillars, window cills,cooking platforms and like in CM(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
S&F anodised aluminium alloy Harrison rails, mildsteel, chromium plated mwith fixing brackets, stops, rollers etc. complete all as specified and as directed.
S&F Soap dish, vitreous China white, approximate size 160x 160x90mm any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed.
S&F Toilet paper holder, vitreous China, box type complete all as specified and as directed.
Taking down chowkhats or frames with shutters not exceeding 1.5sqm (Without taking off shutters from the frame) complete all as specified and as directed.
Taking down chowkhats or frames with shutters exceeding 1.5sqm but njot exceeding 4sqm (Without taking off shutters from the frame) complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and as directed.
Dismantling asbestos cement (corrugated or semicorrugated, etc) sheets in roof coverings etc. complete all as specified and as directed.
S&F MS FI 50x5 mm thick as in wind ties for roof covering including securing with suitable bolts complete all as specified and as directed.
M&L for 25mm thick Cement concrete type B-0, 1:2:4 (12.5 mm graded stone aggregate) for sub base complete all as specified and as directed.
S&F Nylon net bird proofing for shed / storage accn / soft pen and possess the burst strenght upto 44 pounds, shall meet ISO 1806 Protocols, 3/4" mess netting, thickness 0.071" (6 strands, each 0.012" thick), quality control -filaments are twisted and knotted pressure stretched and tightened, break strenght : 52 lbs/2316 Kgs per strand, chemical properties- polyethylene, a paraffin hydrocarbon, is chemically inert, flame retardant and highly resistant to most chemicals at temperatures, high resistance to acids and alkaloids at all concentrations, high temperature of 210°-239°, F/100°-115°, Low temperature -139° to 166°, F/-95° to 110° including all fittings such as rolling pully, iron strips,rope for conrolling net, nails etc. complete all as specified and as directed. Make: As approved by Accepting officer after checking above parameters from manufactures and test certificates.
M&L for cutting existing steel tubing 25/50mm dia GI for alterations or additions complete all as specified and as directed
S&F Ball brass valve with aluminium rod, high pressure, with polythene float and fly nut complete, screwed for 25mm dia iron pipe or brass ferrule complete all as specified and as directed.
M & L for construction of valve pit chamber in PCC (1: 5 : 10) block masonry 200mm thick built in CM (1 :4) with 3.00 thick MS plate and locking arrangement usig necessary 40 x 40 x 5mm thick angle iron on top including excavation and earth work, PCC (1:4:8) type D-2 for foundation PCC bed, coping in cement concrete (1:2:4) type B-1, plastering 15 mm thick in CM (1:4), painting with one coat of bituminous black paint on all steel surface and three coats of white wash of chamber 300 mm x 300mm x 300 mm internal size complete all as specified and as directed.
Surface dressing in any type of soil including site clearance complete all as specified and as directed.
M&L for RCC 1:2:4 type B-1(using 20mm graded stone aggregates) as in foundation, footings, foundation beam, plinth beams and bases of columns basement slabs, and mass concrete complete all as specified and as directed.
M&L for RCC 1:2:4 Type B-1 ( using 20mm graded stone aggregate) as in columns pillers, piers, posts and struts complete all as specified and as directed.
M&L for RCC 1:2:4 Type B-1 ( using 20mm graded stone aggregate) as in beams, cantilevers , bressummers, lintels over 1.5 m span complete all as specifiedand as directed.
M&L for RCC 1:2:4 Type B-1 ( using 20mm graded stone aggregate) as in slabs supported on walls beam and colums in floors, roofs, landings, deck slabs and shelves and the like complete all as specified and as directed.
M&L for RCC 1:2:4 Type B-1 ( using 20mm graded stone aggregate) as in chajjas etc. complete all as specifiedand as directed.
M&L for concrete 1:2:4 typ B-1 (using 20mm graded stone aggregate) on roof slab/terrace as levelling concrete and finished even and fair without using extra cement complete all as specified and as directed.
M&L for sagol finish on plastered surfaces of internal wall and ceiling complete all as specified and as directed.
M&L for complete removal of existing treatment and applying two coats of oil bond distemper over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation of newly plasterered surfaces and applying two coats of Acrylic weather proof coat 100 % exterior grade paint over one coat of primer on wall surfaces as per manufacturer instructions complete all as specified and as directed.
S&F hold fasts confirming to Fe 410-S or Fe 310-S complete all as specified and as directed.
M&L for MS ordinary rat tail rod pattern spring of size 300mm including roller and roller plate complete all as specified and as directed.
M&L for 20-25 mm thick machine cut cudappah stone slab as in jambs / cills / soffits of window / ventilator/ steps as in frame work to support for aluminium section, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete over backing coat 10 mm thick in CM (1:4) complete all as specified and as directed.
S&F sheet glass 5mm thick ordinary quality area not exceeding 0.5 Sqm each pane complete all as specified and as directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
M&L for providing cement concrete (1:2:4) type B-1 (using 20mm graded stone aggreagete ) as in coping, bands, plinth course etc complete all as specified and as directed.
Taking down carefully point wiring complete of any type (batten / surface conduit for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces complete all as specified and as directed.
Taking down carefully sub main wiring complete of any type (batten/surface conduit complete and making good disturbed surfaces complete all as specified and directed.
Taking down carefully by unscrewing DB with MCB boards etc complete all as specified and as directed
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cable for cushioning of cable complete all as specified and as directed. Note : Depth after punning shall only be considered for measurement and payment.
M & L for 40 mm bore GI tube light grade for cable protection with all fittings laid in trenches, on poles to crossing the roads / Nalah etc. complete all as specified and as directed.
S&F in replacement of vertical type DB, doble door Suitable for isolated neutral bar 4 ways, IP 43 protection, door earthing, mechanical impact strength IK 08 insulated busbar assembly, fixed in the wall with suitable nut and bolt including 4 pole MCCB 25 Amp 16 KA fixed in DBs as incommer three phase supply fixed in the wall including taking old DBs any type and cap and making good and match with existing surface of wall, including provn of TPN MCB 32 Amp-01, and MCB SP 6-32 Amp-6 Nos fixed in the DB complete all as spoecified and as directed, Make: Legrand/L&T/Schneider/ABB/Siemens
S&F MCB DB SPN 240 volts 4 way IP 42 protection double door rated busbar complete all as spoecified and as directed, Make: Legrand/L&T/Schneider/ABB/Siemens/Havells
S&F distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof double door, SPN 8 way with Acrylic cover, powder coated fitted with Bus bar, neutral link, earth Bar and din Rail complete all as specified and as directed Make: Legrand/L&T/Schneider/ABB/Siemens/Havells
S&F in repair distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof DB, TPN 12 way with 200 Amps rated copper bus bar, neutral link, IP 43 protection and including 100Amps MCCB, 16kA, four pole and DB fixed flush to wall complete all as specified and as directed Make: Legrand/L&T/Schneider/ABB/Siemens/Havells
S&F distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 230 volts, double door type, fixed flush to wall ( for power points and AC socket) complete all as specified and as directed. Make: Legrand/L&T/Schneider/ABB/Siemens/Havells
S&F MCB’s single pole, 6 to 32 Amps, 230 volts with ‘C’ curve,breaking capacity 10 KA fixed in sheet metal board complete all as specified and as directed. Make: Legrand/L&T/Schneider/ABB/Siemens/Havells
S&F MCB’s single pole & neutral, 40 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
S&F isolator TPN 63 Amps 240 Volts, C' curves of breaking capacity 10 KA complete all as specified and as directed. Make: Legrand/L&T/Schneider/ABB/Siemens/Havells
M&L for point wiring with 1.5sqmm sigle core FRLS PVC insulated cable 1100 V grade with multistranded copper conductor drawn through PVC Conduit with all accessories concealed in the wall and including provision of 1.5sq mm FRLS PVC insulated and unsheathed copper conductor as earth continuity conductor and connected to common earth dolly including fabricated steel terminal box made out of 1.6mm thick MS sheet concealed in the wall with 3 mm thick laminated sheet top cover for munting the switches, socket outlets, fan regulators etc for one light, fan point, fan/exhaust fan point controlled by one switch complete all as specified and as directed.
All as per item No. 168.00 above but for one 3 pin socket outlet 5amps on the same board with other switches
All as per item No. 168.00 above but for One Switch socket 3 pin outlet 5amp on independent board.
All as per item No. 168.00 above but with 2.5sqmm single core FRLS PVC insulated cable 1100 V grade with multistranded copper conductor and including provision of 2.5sqmm single core FRLS PVC insulated cable 1100 V grade multistranded copper conductor as earth continuity conductor connected to common earth for 15amp on independent board. Note for item No. 168.0 to 171.00 : (i) Cutting chases for conduits and sinking's for boxes and making good to walls, floors etc. is deemed to be included in quoted rate. (ii) Make of cable : Finolex/Havells/KEI Industries ltd/L&T (iii) Make of conduit :Finolex/Prince/Prestoplast/Supreme
S&F switch piano flush type single pole one way 5/6 amp, 230 Volts complete all as specified and as directed. Make : Anchor / Havells / Legrand.
Supply and fix Ceiling rose,surface,bakelite,65 x 50mm,three terminals complete all as specified and all as directed. Make : Anchor / Havells / Legrand.
S & F switch socket combination 2 in 1, 5 amp flush type complete all as specified and all as directed. Make : Anchor / Havells / Legrand.
S&F switch socket combination 5 in 1, 5/15 amp flush type complete all as specified and all as directed. Make : Anchor / Havells / Legrand.
S&F one 3 pin socket outlet 5 amp on the same board with other switches complete all as specified and all as directed. Make : Anchor / Havells / Legrand.
Supply and fix Switch socket out let ,multi purpose,3 pin ,5/6 Amps,flush type,230/ volts complete all as specified and all as directed. Make : Anchor / Havells / Legrand.
Supply and fix Switch socket out let ,multi purpose,6 pin ,5/15Amps,flush type,230/ volts complete all as specified and all as directed. Make : Anchor / Havells / Legrand.
S&F socket outlet flush type, single pole, 2 in 1, 5 Amps complete all as specified and all as directed. Make : Anchor / Havells / Legrand .
S&F socket outlet 2 in 1, 3 pin 5/15A, flush type complete all as specified and as directed. Make : Anchor / Havells / Legrand
S&F Socket outlet 3 pin, 5A, flush type including connecting complete complete all as specified and all as directed Make : Anchor / Havells / Legrand
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type including connecting complete complete all as specified and all as directed Make : Anchor / Havells / Legrand
S&F LED batten for LED tube light with 01 No of LED tube 18 watt fixed on two No of Square block with twin core copper flexible wire and including taking down old type tube light fitting etc complete all as specified and as directed. Make : Philips/Havells/Wipro/Crompton
S&F in replacemnent of L ED street light fitting with light 15W with pressure die cast housing along with prismatic polymer carbonate diffuser and LED with secondry optic with IP 65 protection, including provision of GI pipe light grade 32mm bore of suitable size bent to shape fixed with two nos of clamps, nut bolts screw etc including taking down old UNSV street light fitting of any type complete all as speicified and as directed. Make : Philips/Havells/Wipro/Crompton
S&F slim LED tube light batten with light of wattage not less than 20Watt, 2000 Lumen (4 feet long) white / brown colour, fixed to wall / ceiling along with necessary fixing screws, etc. complete all as specified and as directed. Make- Havell's/Philips/Wipro/Crompton
S&F New generation energy saving and environmental friendly long life LED street light with light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. Make: Havells/ Philips/Wipro/Crompton
S&F LUMILINE Plus Wall/surface mounted LED batten extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver optics diffused complete all as specified and as directed. Make: Havells/Phillips/Wipro/Crompton
S&F LED Building security light fitting 45 watt, including lamps High Efficiency IP 65 protection, consisting of Electronic driver circuits, high quality Transmittance lens, powder coated Die Cast Aluminum housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminum housing with SS screws & connecting complete all as specified and as directed. Make:-Crompton/Havells/Phillips/Wipro
S&F in replacement of fan regulator electronic stepped type 5amps flush type on the existing phenolic laminated sheet complete all as specified and as directed.
Taking down Unserviceable ceiling fan from the ceiling/roofs by disconnecting electric connection and diposited to MES store yard complete all as specified and as directed.
S&F ceiling fan of size 1200mm sweep complete, including flexible copper cable 3 core of size 0.5 sqmm from ceiling rose to fan, provision of 3 mm thick circular Bakelite sheet cover including writing MES NO. 2 CM height with synthetic enamel black paint complete all as specified and as directed. Make: Crompton Greaves /Orient/Almonard/Havells
Supply and fix metalic Exhaust fan 300mm sweep 4 blade, AC 230 volts 50 hz single phase complete with louvers and all accesorries incl connection with twin core twised copper flexible cable complete all as specified and as directed. Make: Crompton Greaves /Usha/Almonard/Havells
S&F Exhaust fan heavy duty 230 Volt single phase 380mm sweep 1400 r.p.m.with louver shutter and connection including provision of cable 3 core size of 0.5 sqmm form ceiling rose of connector to fan and making hole in the wall complete all as specified and as directed. Make: Crompton Greaves /Usha/Almonard/Havells
S&F in replacement sub main wiring drawing throug PVC casing and capping with two single core 4sqmm and one run of 4sqmm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade complete all as specified and as directed. Note:(i) Cable shall be FRLS and ISI marked. (ii) One run of casing and caping,three runs of 4sqmm cable shall be measured as one unit. (iii) Make of cable : Finolex/Havells/KEI Industries ltd/L&T (iv) Make of casing and caping :Finolex/Prince/Prestoplast/Supreme/Precision
M&L for Sub main wiring with two run of 4.0 sqmm single core, PVC insulated but unsheathed multistranded FRLS copper cable 1100 volts conductor drawn through in Concealed Heavy duty 20mm dia PVC conduit with all accessories and 4sqmm PVC insulated but unsheathed multistranded FRLS copper conductor cable as earth continuity wire complete all as specified and as directed. Note: (i) Two runs of PVC cable with one run of PVC earth wire and one run of PVC conduit shall be measured as one unit (ii) Make of cable : Finolex/Havells/KEI Industries ltd/L&T (iii) Make of conduit :Finolex/Prince/Prestoplast/Supreme
Material & Labour for sub main wiring with two runs of single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including heavy duty PVC rigid conduit 25mm dia concealed type with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant as earth wire, fixed on wall / ceiling complete for DB connection. Note: (a) 02 Runs of main cable and one run earth wire and one run of PVC conduit shall be measured as one Unit. (b) Cutting chases for conduits and sinking's for boxes and making good to walls, floors etc. is deemed to be included in quoted rate. (c) Make of cable : Finolex/Havells/KEI Industries ltd/L&T (d) Make of conduit :Finolex/Prince/Prestoplast/Supreme
Material & Labour for sub main wiring with four runs of single core multistranded copper conductor cable, of size 10 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including heavy duty PVC rigid conduit concealed type 32 mm dia with all necessary fitting and including two runs single core multistranded copper conductor cable, of size 10 Sqmm, PVC insulated, unsheathed, fire retardant as earth wire, fixed on wall / ceiling complete for Air compressor socket complete all as specified and as directed. Note: (a) 04 Runs of main cable and two runs earth wire and one run of PVC conduit shall be measured as one unit (b) Cutting chases for conduits and sinking's for boxes and making good to walls, floors etc. is deemed to be included in quoted rate. (c) Make of cable : Finolex/Havells/KEI Industries ltd/L&T (d) Make of conduit :Finolex/Prince/Prestoplast/Supreme
Supply and fix air cooled split unit air conditioner 1.5 ton rage 5 star rating inverter compressor variable speed, energy eficient, refrigrent gas R-32 one inlet and one outlet unit, inter connection pipe, remote, manual, two battery inter connection wire etc complete all as specified and as directed. Make : Carrier/Voltas/Usha-Daikin/Bluestar/Hitachi
S&F fluorescent tube light fitting, 1x36 w,230v, Box type, epoxy powder coated CRCA sheet housing with reflector cover channel, with electronic ballasts, bipin holders, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make: Wipro/Philips/Crompton/Havells
S&F Wall mounted fan 400mm sweep 240 volt single phase, complete all as specified and as directed. Make: Crompton Greaves /Usha/Almonard/Havells
S&F metal clad plug & socket board SP & N enclosure with 2 pole and earth metal plug & socket complete with 20 Amp MCB SP, C curve complete all as specified and as directed Make: Legrand/L&T/Schneider/ABB/Siemens
S&F metal clad triple pole and earth enclosure with three pin and earth plugs and socket complete with one triple pole MCB 63 Amps 415 V, C type complete all as specified and as directed Make: Legrand/L&T/Schneider/ABB/Siemens
S&F security light bracket fabricated from 32 mm bore galvanised iron tubing light grade, 1.2 meter long, bent to shape fixed on bldg including mild steel flat iron clamps, nuts, bolts etc including taking down old bracket from existing position complete all as specified and as directed
Labour for disconnecting of old Air compressor along with accessories and shifting to another place as directed in MT complex. Note : T&P required for shifting will be arranged by contractor and rate of the same shall be deemed to be included in quoted rate.
Supplying & laying of reinforce Precast concrete cover of class LV type 1 flate size 250 mm x 150 mm x 40mm for protection for cable complete all as specified and as directed
Supply & laying of reinforced precast concrete cover of class LV type 2 flat size 300x180x40 mm for protection for cable complete all as specified and as directed
Laying only reinforced Precast concrete cable cover of class LV type 1 flat size 250 mm x 150 mm x 40mm for protection for cable complete all as specified and as directed Note : Serviceable old covers obtained from excavation of cable shall be used under this item.
Supplying, laying & Testing cable XLPE insulated armoured, electric power cable, ISI marked (heavy duty), 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and as directed Make : Havells/L&T/Nicco/KEI Industries lts/RR Kabel/Finolex
Supplying,laying & Testing cable XLPE insulated screened ISI maked, PVC bedded, galvanised steel strip or wire armoured, electric power cable , (heavy duty), 1100 volts grade with stranded aluminum conductor of size 50 sqmm 3.5 core laid in trenches, fixing in panel with lugs complete all as specified and as directed Make : Havells/L&T/Nicco/KEI Industries lts/RR Kabel/Finolex
S&F XLPE insulated, armoured heavy duty electrical electrical cable with aluminium conductor, 1100 volts grade, cross sectional area 25 sqmm 3.5 core complete all as specified and as directed Make : Havells/L&T/Nicco/KEI Industries lts/RR Kabel/Finolex
M&L for earthing complete with galvanized steel earth plate electrode 600x600x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate,earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt upto 1.5 meter depth all around the earth plate and connected to earth lead of GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel and thimbles and other end of the earth wire connected to Plant/equipment and protected by galvanized iron or steel pipe light grade 50 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:2:4 type B-1 and RCC cover in 1:2:4 type B1(using 20mm graded stone aggregates) including reinforcement of 6mm dia TMT steel bars both ways @ 150mm C/C and all as shown in electrical plate No. 3 of MES schedule Pt- I of 2009 and also including making test point for testing of earthing made out of gun metal or phosphorous bronge size 75x75x25 mm complete all as specified and as directed. Note : On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values less than 5 ohms. Note : On completion the earth resistance test to be carried out. If desired value of resistance not obtained, the earthing will be re-done at no extra cost.
Material & labor for earthing complete with galvanised steel earth plate electrode 600x600 x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to and including GI wire 4mm earth lead upto 7.5 mtr long by means of bolts, nuts, check nuts and washers etc with GI protection pipe of 40mm bore medium grade and connected to earthing test point all as shown in electrical plate No.3 of SSR part-I and as specified or indicated including excavation & eartwork in any type of soil, PCC (1:3:6) chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with PCC chamber in cement concrete 1:3:6 type C-1 and RCC cover in 1:2:4 type B1(using 20mm graded stone aggregates) including reinforcement of 6mm dia TMT steel bars both ways @ 150mm C/C , with frame, funnel with 20mm bore GI pipe medium grade watering pipe, wire mesh and lugs test point etc and texting on completion complete all as specified and as directed. Note : On completion the earth resistance test to be carried out. If desired value of resistance not obtained, the earthing will be re-done at no extra cost.
KALIKAY ENTERPRISES
MAHAEV ENGG. COMPAY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .