Loading…
Loading…
Tender Value
₹34.9 L
EMD Value
₹70,000
Closing Date
8 Aug 2026, 6:00 pm
CWE (AF) BHUJ
CWE (AF) BHUJ KHAVDA ROAD BHUJ KACHCHH PIN 370001
IMPROVEMENT TO AIR CONDITIONING INSTALLATION AT AF STN BHUJ
2026_MES_779173_1
84277/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BHUJ
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) BHUJ
₹70,000
Yes
17 Jul 2026
17 Jul 2026
11 Aug 2026
17 Jul 2026
8 Aug 2026
1 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M & L for dismantling of MS C-chanel, base plate, foundation bolt, monoblock 03 HP-03 Nos condensor/ chiller pump, electric connection, cooling coil/water pipe, and supply and fixing of new MS C-channel in repair of size 100 x 50 x 5 mm conforming to IS 2062, fabrication and arc welding of all joints, providing and fixing stiffner plates where required, refixing, releveling and alignment of pump, motor providing base plates , nuts, washers, and shims, reconnection of electric cable and all pipes for making plant functional including applying one coat red oxide primer and two coats of approved synthetic enamal paint all as specified and directed by Engg-in-charge. | 4 | Each Job | 1 | ₹4 |
| 2 | M & L for dismantling of MS C-chanel, base plate, foundation bolt, monoblock 05 HP-02 Nos condensor/ chiller pump, electric connection, cooling coil/water pipe, and supply and fixing of new MS C-channel in repair of size 100 x 50 x 5 mm conforming to IS 2062, fabrication and arc welding of all joints, providing and fixing stiffner plates where required, refixing, releveling and alignment of pump, motor providing base plates , nuts, washers, and shims, reconnection of electric cable and all pipes for making plant functional including applying one coat red oxide primer and two coats of approved synthetic enamal paint all as specified and directed by Engg-in-charge. | 2 | Each Job | 1 | ₹2 |
| 3 | M & L for dismantling of MS C-chanel, base plate, foundation bolt, monoblock 05 HP-05 Nos condensor/ chiller pump, electric connection, cooling coil/water pipe, and supply and fixing of new MS C-channel in repair of size 100 x 50 x 5 mm conforming to IS 2062, fabrication and arc welding of all joints, providing and fixing stiffner plates where required, refixing, releveling and alignment of pump, motor providing base plates , nuts, washers, and shims, reconnection of electric cable and all pipes for making plant functional including applying one coat red oxide primer and two coats of approved synthetic enamal paint all as specified and directed by Engg-in-charge. | 1 | Each Job | 1 | ₹1 |
| 4 | M & L for dismantling of MS C-chanel, base plate, foundation bolt, monoblock 10 HP-02 Nos condensor/ chiller pump, electric connection, cooling coil/water pipe, and supply and fixing of new MS C-channel in reapir of size 100 x 50 x 5 mm conforming to IS 2062, fabrication and arc welding of all joints, providing and fixing stiffner plates where required, refixing, releveling and alignment of pump, motor providing base plates, nuts, washers, and shims, reconnection of electric cable and all pipes for making plant functional including applying one coat red oxide primer and two coats of approved synthetic enamal paint all as specified and directed by Engg-in-charge. | 2 | Each Job | 1 | ₹2 |
| 5 | M & L for dismantling of MS C-chanel, base plate, foundation bolt, monoblock compressor 5.5TR-02 Nos, condensor/ chiller pump, electric connection, cooling coil/water pipe, and supply and fixing of new MS C-channel in repair of size 100 x 50 x 5 mm and base plate of existing size conforming to IS 2062, fabrication and arc welding of all joints, providing and fixing stiffner plates where required, refixing, releveling and alignment of pump, motor providing base plates, nuts, washers, and shims, reconnection of electric cable and all pipes for making plant functional including applying one coat red oxide primer and two coats of approved synthetic enamal paint all as specified and directed by Engg-in-charge. | 2 | Each Job | 1 | ₹2 |
| 6 | S & F in repair of condenser coil of 77"(L)X44"(H)X2R & 3/8 OD copper tube condenser with End PELT G.I , suitable for heavy duty air-conditioning/refrigeration plant, complete with copper tubes aluminium fins, factory presurre testing, including removal of old damaged condenser, shifting, brazing/welding of copper joints, leak testing with nitrogen, vacuuming, flushing, refilling of referigerant as required, replacement of drier, final commissioing and performance testing, complete all as specified and as directed by Engineer -in-charge. Note:- Cost of referigerant will be paid seperately under appropriate item of BoQ. | 1 | Each Job | 1 | ₹1 |
| 7 | S & F in repair of condenser coil of 48"(L)X34"(H)X2R & 3/8 OD copper tube condenser with End PELT G.I, suitable for heavy duty air-conditioning/refrigeration plant, complete with copper tubes aluminium fins, factory presurre testing, including removal of old damaged condenser, shifting, brazing/welding of copper joints, leak testing with nitrogen, vacuuming, flushing, refilling of referigerant as required, replacement of drier, final commissioing and performance testing, complete all as specified and as directed by Engineer -in-charge. Note:- Cost of referigerant will be paid seperately under appropriate item of BoQ. | 8 | Each Job | 1 | ₹8 |
| 8 | S & F in repair of cooling coil of 47"(L)X48"(H)X6R & 1/8 OD copper tube condenser with End PELT G.I, suitable for heavy duty air-conditioning/refrigeration plant, complete with copper tubes aluminium fins, factory presurre testing, including removal of old damaged condenser, shifting, brazing/ welding of copper joints, leak testing with nitrogen, vacuuming, flushing, refilling of referigerant as required, replacement of drier, final commissioing and performance testing, complete all as specified and as directed by Engineer -in-charge. Note:- Cost of referigerant will be paid seperately under appropriate item of BoQ. | 2 | Each Job | 1 | ₹2 |
| 9 | M & L for rough excavation not exceeding 1.5 m deep and getting out in hard/dense soil complete all as specified and directed by Engineer-in-charge. | 2.34 | Cubic Metre | 1 | ₹2.34 |
| 10 | M & L for Cement concrete in type C2, (1:3:6) (40mm graded stone aggregate) in foudation filling and mass concrete etc complete all as specified and directed by Engr-In-Charge. | 2.11 | Cubic Metre | 1 | ₹2.11 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
STEEL.pdf
Tender Documents • 0.76 MB
84277TENDER.pdf
Tender Documents • 0.78 MB
APPX B 2026.pdf
Tender Documents • 0.17 MB
BOQ_872727.xls
BOQ • 1.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].