Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹80.8 LAdmitted-Finance 7 91 KOTTARAPATTI PATHALAPETTAI POST TIRUCHIRAPPALLI TAMIL NADU 620013 | TIRUCHIRAPPALLI | TAMIL NADU | 620013 | L1 | Admitted-Finance | |
| 2 | L2₹92.0 L+₹11.2 L (13.8%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹98.5 L+₹17.7 L (21.8%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹1.0 Cr+₹22.9 L (28.3%)Admitted-Finance | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | LAKSHMI ELECTRICAL WORKS L3 | SRI DURGA ENTERPRISES L4 | V.ARUNACHALAM ELECTRICAL CONTRACTOR L1 | POWER ELECTRICAL WORKS L2 |
|---|---|---|---|---|---|---|---|
| 1.00WIRINGS | |||||||
| 2.00Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano/modular type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. | |||||||
| 3.00 | Group B Piano | 30 | Point | 650 ₹19,500 | 900 ₹27,000 | 275 ₹8,250 Lowest | 577 ₹17,310 |
| 4.00 | Group C Piano | 100 | Point | 750 ₹75,000 | 1,000 ₹1,00,000 | 500 ₹50,000 Lowest | 728 ₹72,800 |
| 5.00 | Group B Modular | 30 | Point | 850 ₹25,500 | 900 ₹27,000 | 325 ₹9,750 Lowest | 698 ₹20,940 |
| 6.00 | Group C Modular | 100 | Point | 900 ₹90,000 | 1,150 ₹1,15,000 | 800 ₹80,000 Lowest | 840 ₹84,000 |
| 7.00 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | 10 | Point | 450 ₹4,500 | 1,200 ₹12,000 | 100 ₹1,000 Lowest | 905 ₹9,050 |
| 8.00Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. | |||||||
| 9.00 | Group B | 20 | Point | 430 ₹8,600 | 600 ₹12,000 | 175 ₹3,500 Lowest | 577 ₹11,540 |
| 10.00 | Group C | 20 | Point | 520 ₹10,400 | 850 ₹17,000 | 400 ₹8,000 Lowest | 728 ₹14,560 |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
15 Dec 2022, 3:00 pmClosed
Er.P.Ravi, Assistant Engineer/
EMD, NIT T
Comprehensive Annual Maintenance Contract of LT Installations and Fuse of Calls for Hostel and Quarters Zone
2022_NITT_725386_1
NITT/EMD-C/AE(E)/O-LT/12/22-23
Open Tender
AMC/ Maintenance Contracts
Fixed-rate
365 days
NIT Tiruchirappalli
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹2.0 L
Yes
28 Dec 2022
24 Nov 2022
16 Dec 2022
24 Nov 2022
15 Dec 2022
24 Nov 2022
24 Nov 2022 - 15 Dec 2022
Amount
WIRINGS
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano/modular type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Group B Piano
Group C Piano
Group B Modular
Group C Modular
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required.
Group B
Group C
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 10 sq. mm earth wire
2 X 16 sq. mm + 1 X 16 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
DLP Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed as required.(Make: Finolex/Polycab/RR)
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire
2 X 6.0 sq. mm + 1 X 6.0 sq. mm earth wire
2 X10.0 sq. mm + 1 X 10.0 sq. mm earth wire
2 X 16.0 sq. mm + 1 X 16.0 sq. mm earth wire
4 X 25.0 sq. mm + 2 X 25.0 sq. mm earth wire
1X35 Sq.mm
1X50 Sq.mm
1X70 Sq.mm
1X95 Sq.mm
1X120 Sq.mm
DLP PlasticTrunking wiring (Make: Legrand/MK)
DLP Pastic Trunking 105x50mm and accessories Flexible cover 40mm width-1No,Flexible cover 85mm -1No,Joints for cover 40 mm width-1No, Joints for cover 85mm width-1No,Basejoint-25Nos,Clips-15Nos,Separation partition-1No,Endcap-1No,Internal angles-adjustable from 80 degr - 120 deg - 1No, VDI accessories for internal angles-1No,VDI accessories for external angles -1No, Flat angles -1No, VDI accessories for flat angles-1No, Flat junctions-1No, Flat junctions for specific size-tap off to an 80mm wide branch -1No, VDI accessories for juctions -1No, Wall crossing -1No, Capacity change -1No,Capacity change-1No, partition junction -1No, Cable ties base -1No. (Make: Legrand/MK)
DLP PlasticTrunking with cover 80x50mm flexible cover 65 mm -1No Joints for cover 65 mm width -1No,Base joint -1No,Clips-1No,Separation partition- 1No,End cap - 1No,Internal angles adjustable from 80 degr - 120 deg - 1No ,VDI accessories for internal angles - 1No,VDI accessories for external angles - 1No,Flat angles - 1No,VDI accessories for flat angles - 1No,Flat junctions-1No Flat junctions for specific size-tap off to an 80mm wide branch- 1No VDI accessories for juctions - 1No,Wall crossing-1No,capacitychange - 1No,Capacity change - 1No,partition junction- 1No and Cable tiesbase- 1No.
DLP Pastic mini Trunking system 32x12.5mm and accessories Endcap-1No,Internal angles-adjustable from 85 degr - 95 deg - 1No,Flat junctions -1No.(Make: Legrand)
Supply and fixing of following piano type switch/socket/Regulator on the existing switch box/ cover including connections etc. as required. Make:Lisha/Anchor/GM/Equivalent
5/6 amps Switch/Bell switch/2way switch
15/16 amps Switch
3pin 5/6 amp Socket outlet
6pin 15/16 amp Socket outlet
Socket type Step Regulator
Switch type Step Regulator
Call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Fixing of 5-15 A Switch/Socket/Bell Push/Indicator/Regulator
Replacement of 5-15 A Switch/Socket/Bell Push/Indicator/Regulator
Supply and fixing of following Modular/Arteor type switch/socket on the existing switch box/ cover including connections etc. as required. Make:Legrand/Lisha/Anchor/GM/MK/Equivalent
5/6 amps Switch/Bell switch/2way switch
15/16 amps Switch
3pin 5/6 amp Socket outlet
6pin 15/16 amp Socket outlet
Socket type step Regulator
Blanking plate
Call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Fixing of 5-15 A Switch/Socket/Bell Push/Indicator/Regulator
Replacement of 5-15 A Switch/Socket/Bell Push/Indicator/Regulator
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. Make:Legrand/MK/Equivalent
1 or 2Module
3 Module
4 Module
6 Module
8 Module
12 Module
Supplying and fixing following modular base & cover plate on existing modular metal boxes etc as required.Make:Legrand/MK/Equivalent
1 or 2Module
3 Module
4 Module
6 Module
8 Module
12 Module
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.Make:Lisha/Anchor/GM/Equivalent
Supplying and fixing patten/ angle holder including connection etc. as required. Make:Lisha/Anchor/GM/Equivalent
Supplying and fixing of 3 pin, following amps pin top including connection etc. as required. Make:Lisha/Anchor/GM/Equivalent
5/6 Amps pin top
15/16 Amps pin top
Supplying and fixing of following size of MS box with Hylam sheets with 3.0mm thick including making slots for switches & Sockets etc., as required.
100mm X 100mm
150mm X 100mm
250mm X 200mm
300mm X 200mm
100mm X 100mm Hylam Sheet only
150mm X 100mm Hylam Sheet only
250mm X 200mm Hylam Sheet only
300mm X 200mm Hylam Sheet only
T5/LED/METAL HALIDE/CFL FITTINGS
Supply and fixing of industrial patten suitable for TL5 lamp 28w Available with optional reflector. (Make: Bajaj,Crompton Greaves & philips/Equivalent etc) (with 2 years manufacturer's warranty)
TMSI 22 M 1 X TL5 -28W EBT with lamp
TMSI 22 M 2 X TL5 -28W EBT with lamp
22W 4 Feet LED batten BN021C LED22S
40W 4 Feet LED batten BN 021 LED40S- 6500 PSU GR
10W 2 Feet LED batten
T5 28w Tube
Electronic Choke suitable for T5 28W fitting
T5 14W Tube
Electronic Choke suitable for 9-14W
36W Tube
Electronic choke suitable for 36W fitting
36W Starter
7W B22 Base LED Bulb
7W E27 Base LED Bulb
Supplying and fixing street light luminaire with die cast aluminum housing and toughened glass cover with min IP65 protection , with the LED Type fixtures of following Wattage complete with all accessories and drivers, LN6 heat sink minimum 5kVA surge protection low power LEDs with driving current less than 350mA etc. on existing brackets on street light poles including connection & loop earthing with 3 core 1.5 sqmm flexible PVC insulated PVC round sheathed copper conductor cable from street light box to fitting, testing and commissioning etc. as required. (with 5 years manufacturer's warranty) (Make: Havells,Bajaj,Crompton Greaves, & philips etc)
LED 40-45W ST white colour lamp.
Drive for 40-45W LED
LED 90W ST white colour lamp.
Drive for 90W LED
Supply and fixing of outdoor of LED Floodlighting for instant start, Extruded aluminium heat sink, designed to act as efficient heat dissipater – important for LED luminaires, Pressure die-cast aluminium cover on both sides for holding of extruded aluminium heat sink, Luminaire provided with heat resistant toughened glass, Control gear compartment is an integral part of luminaire, LEDs are provided with secondary lens optics to get optimum optical performance, The driver used is specially designed to have surge voltage, open/short circuit protections and Luminaire is provided with a mounting bracket fixed on pressure die-cast aluminium covers for aiming adjustment etc. as required. (Make: Bajaj, Philips, Stand LED)
140W LED Flood light
Drive for 140W LED
240W LED Flood light for High Mast lightings
Drive for 240W LED
Supply and fixing of following rating metal halide fitting (phillips MWF 331) in existing pole i/c 3x1.5 sq mm wire from pole mouting box to fitting. Make : Bajaj/Philips/Crompton/Havells/Equivalent
MWF331 1xHPITP150W S 150w lamp
MWF331 1xHPITP250W S/A 250w lamp
MWF331 1xHPITP400W S/A 400w lamp
70w Metal Halide lamp
150w Metal Halide lamp
250w Metal Halide lamp
400w Metal Halide lamp
Ignitor for 70W MH lamp
Ignitor for 150W MH lamp
Ignitor for 250W MH lamp
Ignitor for 400W MH lamp
70W Metal Halide choke
150W Metal Halide choke
250W Metal Halide choke
400W Metal Halide choke
Supply and fixing of PLL-PLC 2Pin and 4Pin lamp with connections etc as required. Make Philips/Crompton/Havells/Equivalent
9-11W PLC 2P
11-13W PLC 4P
18W PLL 4P
36W PLL 4P
Supply and fixing of B22, E14, E27 base LE/ CFL Make: Philips/Crompton/Havells/Equivalent
B22 base 11-13W CFL
B22 base 18 - 20W CFL
B22 Base 7-9W LED lamp
E14 base 3-5W LED lamp
E27 base 11-13W LED lamp
4 Pin 18W LED lamp
Supply and fixing of indoor decorative tube light fitting of high efficincy luminaire range suitable for recessed/surface mounting in moudular ceiling with 600 x 600/300X300/round type module and extemely low hight of 50 mm. (Make: philips / Crompton Greaves/ Havells etc)
2X2 Size T5/14W fitting with tubes.
4X14W E- choke
Supply and fixing of indoor decorative LED fitting of high efficincy luminaire range suitable for recessed/surface mounting in moudular ceiling with 600 x 600/300X300/ Square type module and extemely low hight of 50 mm. (Make: Crompton Greaves, philips etc)
2x2 LED TUBE Light fitting with tubes.
LED Drive 8-10W LED driver for 2 X 2 Light fitting Uin=240-, Fin=50hz, Iin=0.23A max,Pin=52W max ,PF(λ)=0.95 Typ.,Iout=0.60A,ULED=57-67V DC,Uout=115V DC max,ta=0-50°C,tc=+70°C
1x1 LED 24W TUBE Light fitting with tubes.
LED Drive for 1x1 LED TUBE Light.
LED Tube LPLL-18-CDL
2x2 LED Fitting
2 (or) 3inch round/ square type LED fitting
FAULT ATTENDING & CLEANING OF INDOOR LIGHTS/FITTINGS
Checking, identifying the faults in T5-28/40W tube light fitting,cleaning and rectification of the faults by replacement of one (or) more of the followings:Lamp,choke,Capacitors,lamp holder, terminal block, driver unit,inter Connection wiring from DL-MCB to ceiling rose/ terminal Strip and to fitting.
Checking, identifying the faults in 70-400W Metal Halide/HPMV/HPSV roof light fittings/street light fittings and rectification of the faults by replacement of one (or) more of the followings:Lamp,choke,Capacitors,lamp holder, terminal block, driver unit,inter Connection wiring from DL-MCB to ceiling rose/ terminal Strip and to fitting.
Checking, identifying the faults in 45-140W LED fittings/street light fittings and rectification of the faults by replacement of one (or) more of the followings:Lamp,choke,Capacitors,lamp holder, terminal block, driver unit,inter Connection wiring from DL-MCB to ceiling rose/ terminal Strip and to fitting.
Checking, identifying the faults in High Mast light fittings and rectification of the faults by replacement of one (or) more of the followings: Lamp, choke, Capacitors, lamp holder, terminal block, driver unit, inter Connection wiring from DL-MCB to socket / terminal Strip and to fitting including hoisting and lowering of Mast etc.as required.
Removing and fixing of Street light adaptor box and checking of MCB including connections as required.
Removing and fixing of 1X28W/2x28W /40W/65W/80W/box type/industrial type fluorescent tube light fittings including hand over to EMC
Cleaning of 1X28W/2x28W /40W/65W/80W/4x24 w box type/industrial type fluorescent tube light fittings including the reflectors/diffucers etc
Maintenance of street light distribution panelcleaning with thinnger and tight checking including replacement of bolt, nuts & washers of the existing materials.
FAN REWINDING WORKS
Ceiling fan/Exhaust Fan/Wall mount Fan rewinding works with minimum 1year warranty
Ceiling Fan Winding
Exhaust Fan Winding 300mm
Exhaust Fan Winding 380-450mm
Exhaust Fan Winding 600mm
Wall mount Fan Winding light duty
Wall mount Fan Winding medium duty
Wall mount Fan Winding heavy duty
Rewinding of three phase mono/jet pump with old winding buy back and 1 year minimum warranty
Rewinding of three phase submersible pump with old winding buy back and 1 year minimum warranty
Rewinding of single phase mono/jet/submersible pump with old winding buy back and 1 year minimum warranty
Servicing of following rated single/three phase mono/jet pump shaft servicing, lathe works, re-arrangement of shaft position, ball bearing works and complete oiling, servicing with necessary transportation etc. as required
7.5 HP to 10 HP
Supply, Installation, Testing and commissioning of 3Ph, 415V, Direct-Online Starter with OLR, Volt & Ammeter, Push button type ON/OFF control and ON/OF indication lamp including necessary connections etc.as required (Make: L&T, ABB & Seimens)
3.0HP to 7.5 HP
Supply, Installation, Testing and commissioning of 3Ph, 415V, Direct-Online Starter with OLR, Volt & Ammeter, Push button type ON/OFF control and ON/OF indication lamp including necessary connections etc.as required (Make: L&T, ABB & Seimens)
0.5 HP to 3.0 HP
Supplying and fixing of ceiling fan of following sweep, suitable for operation on 230 Volts, single phase, 50 Hz, AC Supply including 300 mm long down rod as equired.(Make: Crompton Greaves/Rivera/Equivalent)
1200mm Sweep
G.I.Pipe down rod length 90 cm and dia 20 mm ,2(or) 3mm thickness
Fan service ball bearing set replace work
Supplying and fixing extra conduit down rod of 150 cm length G.I. pipe 20 mm dia, heavy gauge including painditing etc.required. (Note: More than 5 cm lenth shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored.)
Replacement of Condensor including labour
Fan clamp set including labour
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supply and fixing of heavy duty 960 RPM exhaust fan of following sweep, suitable for operation on 230 Volts, single phase, 50 Hz, AC Supply including suitable size louvers etc., as required.
300mm Blade
380mm Blade
450mm Blade
600mm Blade
Replacement of condensor including labour
supply and fixing readymade round cement block for following size of 300, 380 & 400mm labour charges for exhaust fan fixing including mesh wire ,wall cutting bolt nuts fixing and finishing.
Supplying and fixing of wall mounting fan of following 450mm sweep , suitable for operation on 230 Volts, single phase, 50 Hz, AC Supply including wall braket rod and resistance type regulator as required.
Light duty
Medium type
Heavy Duty
FIXING/CLEANING/NUMBERING OF FAN
Fixing of Ceiling Fan 1200/1400 mm sweep
Fixing of MS "S" type/MS "Anger fastener" type fan hook including chipping, fixing & surfacing to make good condition..
Cleaning of ceiling fan/exhaust fan /Pedestal fan completely .
Supplying Printed labels for tubes,fans,lights etc as required. Ex:for Ceiling fan NITT/C.F/1
E A R T H I N G
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as required.
Supply and laying of 6 SWG GI wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supply and laying of 6 SWG Copper wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supply and laying of 25 mm X 6 mm Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.
Supply and laying of 25 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Cosmos roma 40mm dia 2Mtrs length with moisture enhancer 25 Kg.
Cosmos roma 40mm dia 3Mtrs length with moisture enhancer 25 Kg.
Earth bit testing and value writing in paint
CABLES Make : Gloster/Havells/Finolex/RK/Polycab/Equivalent
Supply of aluminium Armoured XLPE UG CABLE 1.1KV as per ISI Specification IS:7098/(Part-II) 1985 with latest amendments
2x16.0 Sq.mm
4x16 Sq.mm
4x25 Sq.mm
4x50 Sq.mm
3.5x70 Sq.mm
3.5x95 Sqmm
3.5x120 Sqmm
3.5x150 Sqmm
3.5x185 Sq.mm
3.5x240 Sq.mm
3.5x300 Sq.mm
CABLE FAULT
Find out LT cable fault using cable fault locater instrument including excavation & Re-Filling trench
Excavation of refilling the trench with sand, brick or cable dub(cover) LT Cable Joint Per Location 3.5 X120 -300Sq.mm
Supply and laying of following size Double walled Corrugated High Density Polyethylene pipe having corrugation on the outer wall and plain surface inner wall conforming to IS 14930 part- I and part -II complete with necessary HDPE fitting for protection of 1.1 KV grade under ground cable directly in ground at a depth 75cm including inserting of cable and excavation and refilling the trench etc as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
90 mm dia (OD-90 mm & ID-76 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
160 mm dia (OD-160 mm & ID-135 mm nominal)
200 mm dia (OD-200 mm & ID-175 mm nominal)
MV CABLE LAYING
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Removing & Re-Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in existing trench and the same cables handover to EMC stores etc. as required.
Removing & Re-Laying Upto 400 Sq.mm
Safe Rmoval of AA UG cable from the ground and same cables hand over to EMC store etc. as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
GI/RCC/PVC Pipes
Supplying and fixing of following size Medium class G.I. pipe bended to required shape having threaded top end with chucknuts to fix in looping box, and fixing in pole coller /foundation as required.
50 mm dia. G.I. pipe (medium class)
80 mm dia. G.I. pipe (medium class)
100 mm dia. G.I. pipe (medium class)
150 mm dia. G.I. pipe (medium class)
Supplying and erection of following size Medium class PVC pipe bended to required shape having threaded top end with chucknuts to fix in looping box, and fixing in pole coller /foundation as required.
25 mm dia.PVC. pipe (medium class)
32 mm dia.PVC. pipe (medium class)
40 mm dia. PVC. pipe (medium class)
50 mm dia.PVC. pipe (medium class)
Providing, laying and fixing following dia RCC pipe NP 2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.
150 mm dia
300 mm dia
Supplying and making LT cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 30 cm with a thickness of 8cm including inscription duly engraved as required.
MV /HV CABLE TERMINATION /JOINT KITS
Supply and Making MV cable end indoor/outdoor termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Make: Mseal/Equivalent
2 X 16-50 sq. mm
3½ X 70-95sq. mm
3½ X 120-185 sq. mm
3½ X 240-400 sq. mm
4 X 16 sq. mm
4 X 25-35 sq. mm
4 X 50 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Make: Mseal/Equivalent
2 X 16-50 sq. mm
3½ X 70-95 sq. mm
3½ X 120-185 sq. mm
3½ X 240 sq. mm
3½ X 300 sq. mm
3½ X 400 sq. mm
4 X 16 sq. mm
4 X 25-35sq. mm
4 X 50 sq. mm
Supply & Fixing of Meters/Hose/Acrylic sheets/UPS
Direct connected (Whole current), 3Phase 4Wire,230/240V (P-N), 400/415V (P-P)
Direct connected (Whole current), 3Phase 2Wire,230/240V (P-N)
Energy meter reading taking in Qtrs zone including preparation and issue of bills
Energy meter reading taking in Mess and shopping stalls including preparation of bills
Providing temporary supply to stalls and mess areas including preparation of bills
Labour charges for installing UPS/inverter with connections as required.
2-5kVA,1Ph/3Ph
7.5-20kVA,1Ph/3Ph
Carried out Maintenance of DBs,MV panel
MCCB,MCB&DB'S
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required including removing charges. Make : Legrand/Equivalent
Single Pole
Double Pole
Triple Pole
Four Pole
Double/Triple/Four pole enclosure
Supplying and fixing 240/415 volts, "C" curve, ELCB suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required including removing charges. Make : Legrand/Equivalent
25A , DP,30 mA
40A DP,30mA
63A FP 30mA
Supplying and fixing for following amps rating, 240/415 volts,"C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make : Legrand/Equivalent
Triple pole 40-63A MCB
Four pole 40-63A MCB
Supplying and fixing of following amps, 240 volts, SPN industrial type, socket outlet, with 1 pole and earth,metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Make : Legrand/Equivalent
1P 20A industrial socket
2P 20A industrial socket
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2 + 8 way, Double door
2 + 12 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
8 way (4 + 24), Double door
Supplying and fixing following way, Vertical type three pole and neutral, sheet steel, MCCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (With Out MCCB's)
125-160A 8 way Double Door
200-250A 8 way Double Door
Providing and fixing following rating and breaking capacity and pole MCCB with Thermal Magnetci Release in existing MCCB DB, making connections, etc. as required. (Make: L&T, Legrand, Schnider - NSX or Equivalent)
4 pole 125A, 36 KA
4 pole 160A, 36KA
4 pole 200A, 36 KA
4 pole 250A, 36KA
Providing and fixing following rating and breaking capacity with thermal magnetic release and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, including copper bus bar etc. as required. (Make: L&T, Legrand, Schnider - NSX or Equivalent)
4 pole 200A, 36 KA
4 pole 250A, 36KA
Supply and fixing of rotary handle including necessary extender, drilling slots in cubical panel etc as required
DN1 160-250 Rotary Handle
DN2 400-630 Rotary Handle
GEYSER/WAMMER/Grinder/Chapathi machine
Supply and Installtion of 2kW, 25 liter storage type Geyser (Bajaj, Harvells, Venus, Racold)
Supply and Installtion of 2kW, 15 liter storage type Geyser (Bajaj, Harvells, Venus, Racold)
Fixing of geyser
Geyser fault attending works
Supply and replacing of Geyser coil
Supply and replacing of thermostat
PEST O FLASH fault attended works
Mess Wamer Fault attended works
Wammer coil replace works
Grinder fault attended for three phase and single phase.
Chappathy mixed machine fault attended
Fuse of calls (Attending of Power failure)
Supplying and fixing glass reinforced SMC (sheet moulding compound) looping box of nominal size not less than 250mm X 170mm X 100mm deep on the existing street light foundation with built-in bracket clamp, terminal block & mounting plate etc.,
High Mast Light
Supply and fixing of following high mast lighting accessories and materials etc as req.
Imported 63A, 10 Pin Male and Female metal socket
Capacitor 42 MFD, 220V
E40 porcelain Holder
Rubberised Trailing Cable 8Cx 4sqmm copper
Control gear box Housing for 2x400W choke, Ignitor etc as req.
Analog type Timer Model no-J648B1 (Make:L&T/Siemens)
3 Pole 25A Contactor 1NO+1NC
Contactor Coil 220V
Providing services on Emergency/Function duties, Labour charges will be given only beyond working days if approved by engineer incharge
Skilled
Semi Skilled
Hiring of E-Scooter bike with 145-150km ARAI certified range, minimum 3kW battery capacity with fast charging capability, 24x7 basis minimum 2Nos required etc. as required.(Make: Ather, OLA and TVS)
POWER ELECTRICAL WORKS
LAKSHMI ELECTRICAL WORKS
SRI DURGA ENTERPRISES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .