Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹12.7 LAccepted-AOC | L-1 | Accepted-AOC Accepted | |
| 2 | L-2₹13.5 L+₹47,890 (3.68%)Rejected-AOC C O ABDUL GANI ISMAIL NALIYA KUTCH PIN 370655 GUJARAT | KACHCHH | GUJARAT | 370655 | L-2 | Rejected-AOC Rejected | |
| 3 | L-3₹14.4 L+₹1.4 L (10.4%)Rejected-AOC OPP RAM MANDIR NALIYA KUTCH 370655 | KACHCHH | GUJARAT | 370655 | L-3 | Rejected-AOC Rejected | |
| 4 | L-4₹15.3 L+₹2.3 L (17.5%)Rejected-AOC HOUSE NO 120 1 NEAR HANUMAN MANDIR AT POST SHEL PIMPALGAON TAL KHED DIST PUNE PIN 411014 | PUNE | MAHARASHTRA | 411014 | L-4 | Rejected-AOC Rejected | |
| 5 | L-5₹15.4 L+₹2.4 L (18.4%)Rejected-AOC PLOT NO 52 SIDDARTH PARK BEHIND ICE FACTORY RAVALWADI BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | L-5 | Rejected-AOC Rejected |
Tender Value
₹13.9 L
EMD Value
₹27,800
Closing Date
2 Aug 2021, 6:00 pmClosed
GE AF Naliya No 1
GE Air Force Station Naliya No 01
REPAIR AND MAINTENANCE OF STREET LIGHT SECURITY LIGHTS AND CONNECTED MISC ITEMS AND REPAIR RENEWAL OF INTERNAL WIRING FITTINGS FIXTURES REPAIR TO CEILING EXHAUST FAN GEYSERS AND LIGHTING CONDUCTOR IN CERTAIN PLACES AT AF STN MOTHALA
2021_MES_457440_1
8770/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Naliya
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE AF Naliya No 1
₹27,800
Yes
16 Dec 2021
6 Jul 2021
4 Aug 2021
6 Jul 2021
2 Aug 2021
20 Jul 2021
6 Jul 2021 - 13 Jul 2021
Amount
Dismantiling / taking down LED 40/65/70/100/150W street light / security lights / High Mast of any capacity & description from exising LT pole / walls, at any height and refixing the fittings in existing / another location after repair work or carrying to MES store complete all as specified and as directed. Note for item No. 01 above:- (i) Replacement of defective parts accessories shall be measured and paid separately under relevant item of Sch 'A' as supply only. (ii) Transport and T & P i.e. Ladder, spanners or any other equipment for repair of street light shall be arranged by contractor and cost for the same deemed to be included.
M&L for street light brackets made up of 40 mm dia G.I. Pipe light grade in shape and angle as directed not exceeding 1.5 mtrs in length fixed to pole with suitable size of M.S. clamps made of M.S flat of size 40 mm x 3 mm, 2 Nos, M.S nut & bolt with cup washers and dismantling old rusted / unserviceable bracket with its rusted clamps and nut bolts complete all as specified and as directed.
S&F in replacement Street light timer analog clock type with suitable for connection with three phase supply and connected to existing contact for cotntrolling complete all as specified and as directed. Make: L&T Model-AUTS03ANA00 / Havells / Indoasian / CG
S&F in repair 1100 volts grade PVC insulated PVC sheathed cable weather proof multisranded / solid aluminium conductor 3 core 4.0 sqmm from junction box to connector of fitting complete all as specified and as directed.
S&F in repair MCCB 4 pole 'C' curve 100 Amps, 415 Volts AC, 16 kA in existing street light panel and connection with bus bar out going cable with copper wire with MCCBs complete all as specified and as directed. Make- Havell's/CG/L&T/Schneider
All as per item No. 5 bove but MCCB 4 pole 'C' curve 40-63 Amps, 415 Volts AC, 16 kA
S&F in existing Street light panel and connection with bus bar out going cable with copper wire with power contactors 3 phae, 415 V, 40 Amps, in repair complete all as specified and as directed. Make: L&T Model ML-3 SS90721 /Schinder/ ABB / Siemens/ HPL
S&F in replacement of T-5 Fittings of 2x24W with LED street light minimu of 40 W IP 65 protected, powder coated pressure die cast aluminium High Power LED Street light with heat resistant toughened glass, complete all as specified and as directed. Make: Havells, Model ENDURAPEARLNEOSL40WLED757PASYTOPC HSN Code-9405 /Philips/ CG / BAJAJ
S&F SMC based outdoor type Junction box pole Hinged (L) mounted with clamps and including MCB SP06 Amps complete all as specified and as directed. Make: Sintex Model No: GS JB 2817 / Any approved brand.
S&F in replacemet of 100/150 Watt fittings High efficiency long life CREE LED chip in modules of 40/72/100W each (6x5 array) with Ra>75 and lumen efficacy of >95 lum/watt or equivalent suitable forsuitable for LED light fitting of 40/72/100 watt complete all as specified and directed. Make : Philips/Shakti/ Havells/CG/Surya
All as per item No.10 above but 72 Watt fittings
All as per item No.10 above but 40 Watt fittings
S&F in replacement of Metal halide (MH) lamp suitable for 250 watts metal halide fittings, screw type complete all as specified and directed. Make : Philips/Bajaj/ Havells/CG
Supply only Ballast suitable for 250 Metal halide (MH) flood light fitting complete all as specified and directed. Make : Philips/Bajaj/ Havells/CG
Supply only holder edison screw type for 250 watts MH flood light fitting complete all as specified and directed. Make : Philips/Bajaj/ Havells/CG
Supply only ignitor, super imposed ignitor for metal halide fitting 250 W complete all as specified and directed. Make : Philips/Bajaj/ Havells/CG
S&F in replacement of LED street light fitting driver of exisiting make and model of rating 40 Watt complete all as specified and as directed. Make: Bajaj/CG/Philips
S&F in replacement of LED street light fitting driver of exisiting make and model of rating 60 W to 150 Watt complete all as specified and as directed. Make: Bajaj/CG/Philips
S&F in replacement of LED Post top of 25 Watt Integral pole mounted decorative LED with IP-65 protection complete fixed on existing post complete all as specified and directed. Make-Havell's Cat part no-CORALPT25WLED757PSYMTOPC / Crompton / GE / SURYA
Taking down carefully copper / aluminium point wiring, (light, fan, socket, power) of teakwood batten, PVC casing and caping, PVC/steel conduits, complete including fixure and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, bell/buzzers etc complete and making good distributed surfaces of walls floors etc , complete all as specified and as directed.
M & L for point wiring with 1.5 sq mm ISI marked FRLS single core PVC insulated unsheathed 1100 V grade with multistranded copper conductor drawn through PVC casing and capping with all accessories fixed to wall /roofs ceiling etc and incl provision of 1.5 sq mm ISI marked FRLS single core PVC insulated and unsheathed copper conductor as earth continuity conductor and connected to common earth dolly including PVC box ISI marked of suitable size for mounting the switches , socket outlets , fan regulators etc all as s specified and directed for One light point controlled by one switch
All as per item No. 21 above but for One fan point controlled by one switch through regulator
All as per item No. 21 above but for One Exhaust fan point controlled by one switch
All as per item No. 21 above but for One 3 pin socket out let 5 Amp on independent board
All as per item No. 21 above but for One 3 pin socket out let 5 Amp on same board with other switches
All as per item No. 21 above but for One bell /buzzer point controlled by one push button on same board
All as per item No. 21 above but with 2.5 sqmm single core cable for one 3 pin socket outlet 15 Amps on independent switch board including 2.50 Sqmm as earth continuity conductor and connected to common earth dolly complete all as directed and specified.
S&F in replacement switch socket outlet 2 in 1multipurpose 3 pin, 5/15/16 Amps combination and 3 pin 5 Amps controlled by one switch complete all as specified and as directed.
All as per item no. 28 above but of modular type
S&F in replacement of switch piano flush button SP one way 5/6 Amp complete all as specified and as directed
All as per item no 30 above but of modular type
S&F in replacement switch socket combination 3 pin 5 / 6 Amp flush type multipurpose complete all as specified and as directed.
All as per item no. 32 above but modular type
S&F in replacement call bell Ding Dong type, AC, 230 volts, single pole controlled by one bell push complete all as specified and as directed.
S&F in replacement for bell push, AC, 230 volts, single pole complete all as specified and as directed.
S&F in replacement ceiling rose three terminal,PVC/Polycarbonate, Isolated body, complete as specified and as directed.
S&F in replacement of electronic resistance step type speed regulator suitable for 1200 mm sweep ceiling fan up to 300 watt complete all as specified and as directed.
S&F in replcament of Tube light fitting 1x28 Watt / 1x36 watt with slim LED tube light batten of wattage not less than 20 Watt, 2000 Lumen (4 feet long) white / brown colour, fixed to wall/ ceiling along with necessary fixing screws, etc. complete all as specified and as directed.
Supply and fix in replacement of old 2x36 / 2x 28 watt tube light fitting in false ceiling with LED Square recess mounting powder coated white CRCA full glow LED panel Downlight of 36 Watt Warm White fitting with LED lights complete along with necessary connecting cable of PVC insulated 3 core 0.5 sqmm from fitting to ceiling rose / connector complete all as specified and directed. Make-Havell's Model No.VENUSNEOHE2X2PLR18-42WLED830MOD /CG/ GE /SURYA
M&L for in replacement of earthing including necessary excavation complete with galvanised steel earth plate electode 600 x 600 x 6 mm thick buried directly in ground earth pit with adequate quantity of charcoal and dust and common salt, not less than 2.25 mtr deep below ground level connected to & including galvanised earth lead wire 4 mm dia drawn through GI protection pipe of size ordered specified for protection of earthing lead from earth electrode to test point / main DB from mechanical injury or tempering by means of nuts and bolt check nuts and washers of galvanised iron sheet all as shown in electrical plate No. 3 of SSR Part - I and connected to earthing test point complete including testing, refilling earth and removal of surplus soil upto 50 mtrs, PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made out of 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed.
M&L for in replacement of Sub main wiring with two runs of 4.0 sqmm single core, PVC insulated but unsheathed multistranded FRLS copper cable 1100 volts conductor drawn through in Concealed Heavy duty 25mm dia PVC conduit with all accessories and 4.0 sqmm PVC insulated but unsheathed multistranded FRLS copper conductor cable as earth continuity wire complete all as specified and as directed. Note: Two runs of PVC cable, one run of PVC earth wire and one run of PVC conduit shall be measured and paid as one length only.
S& F in replacement Factory made sheet metal enclosure MCB DB (Protection class IP-42) Double door with Acrylic cover, powder coated DB's fitted with 200 Amps Bus bar, neutral link, earth Bar and din Rail for SPN, 4 way, 240 Volts complete all as specified and as directed.
All as per item No. 42 but SPN, 8 way, 240 Volts
All as per item No. 42 but SPN, 12 way, 240 Volts
All as per item No. 42 but TPN, 4 way, 415 Volts
S&F in replacement of MCB TP 25 to 63 Amps of approved make, 'C' curve type & 10 KA breaking capacity, at locations complete all as specified and as directed.
All as per item No. 46 but MCB TP 16 to 32 Amps
All as per item No. 46 but SPN 40 to 63 Amps
All as per item No. 46 but SPN 32 Amps
All as per item No. 46 but SP 5-32A Amps
S&F in replacement RCCB, double pole, 25 Amps,sensitivity 100mA, 240 volts complete all as specified and as directed.
S&F in repair Air termination, single point copper rod 12 mm dia and 300 mm long complete all as specified and as directed.
S&F in repair Test point terminal box of size 200x100x100mm made out of 2mm thick hot dip galvanized sheet drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with test point terminal block made out of Gun metal or Phosporous Bronze size 75x75x25 mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws, etc complete all as specified and as directed.
S&F Copper strip 20 x 3 mm fixed with saddles, insulators and screws etc for roof conductor and down conductor above ground, complete all as specified and as directed.
Dismantling of complete Ceiling fan 1200 /1400 mm sweep (i.e.,) down rod with its Canopies, Shackle, Condenser housing with its rubber bushes, split pins, unscrewing the body parts of Ceiling fan, taking out starter, rotor winding ball bearing, gun metal bush etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and rewinding of starter with suitable size of Copper enamelled wire, varnishing heating as per manufactures design and directed. (b) Re-assembling complete Ceiling fan by fixing only serviceable of old/new spare parts (i.e.,) rubber bush of shackle and condenser housing, condenser, gun metal bushes, ball bearing, twin twisted Copper cable, down rod assembly with its shackle condenser housing and Canopies & split pins complete all as specified and design to give designed air delivery including greasing, oiling etc all as directed.
All as per Item No.55 above but exhaust fan of size up to 450 mm sweep complete.
All as per Item No.55 above but Air circulator fan of size 610 mm sweep complete
All as per Item No.55 above but wall mounted fan of size 450 mm sweep complete. Note Sl.No.55 to 58 (a) Supply only spare parts found unserviceable/defective shall be measured and paid separately under relevant item of Sch 'A'. (b) The rate for fixing serviceable items are deemed to be included in unit rate of above item. (c) The Contractor has to quote credit for all retrived unserviceable item obtained from dismantling separately under relevant item of 'Schedule of Credit'.
All as per Item No.55 above here-in-before but only overhauling of celing fan 1200mm/1400mm by greasing and oiling instead of rewinding of starter winding complete all as specified and as directed.
All as per Item No. 59 above but exhaust fan of 300 to 450 mm sweep complete all as specified and as directed.
All as per Item No.59 above but Air circulater fan of 610 mm sweep complete all as specified and as directed.
All as per Item No.59 above but wall mounted fan 450 mm sweep. Note Sl.No 59 to 62 :- (a) The rate for dismantling/refixing in position is deemed to be included in the quoted rate. (b). Supply only Parts replaced if any shall be paid separately under relevant items.
Supply only condenser for ceiling fan as per existing make for Ceiling fan of different makes 1200mm /1400mm sweep complete all as specified and as directed.
All as per item No.63 but Gun metal bush for ceiling fan as per existing make complete.
All as per item No.63 but Gun metal bush for wall mounted fan as per existing make complete.
All as per item No.63 but Gun metal bush for air circulator fan as per existing make complete.
All as per item No.63 but Ball bearing for wall mounted fan as per existing size and make complete.
All as per item No.63 but Ball bearing for air circulator fan as per existing size and make complete.
All as per item No.63 but Ball bearing for ceiling fan as per existing size and make complete.
S&F three twisted copper flexible wire/cable of 0.5 sqmm
S&F in repairs Apparatus assembly duly prewired without heating element and thermostat/thermal cutout for Geyser, storage type, 25/50 Ltr capacity all as specified and directed.
S&F in repairs Thermostat/Thermal cut out as per sample for Geyser, storage type, 25/50 Ltr capacity complete all as specified and as directed.
S&F in repairs Heating element 1.5 KW/2 KW, any type as per sample (cup, thread, triangle base type), for Geyser, storage type, 25/50 Ltr capacity complete all as specified and as directed. Make : Bajaj/ Racold/ Sphern/ Johnson.
S&F in repairs PVC reinforced pipes of connecting pipes15mm dia both end socketed with brass nuts 450mm long heavy duty of suitable thickness for hot/cold water complete all as specified and as directed.
Taking out inner tank assembly from Geysers of any capacity/make for repair /welding with brass brazing and refixing to its original position and making good complete all as specified and as directed.
M&L for in replacement of earthing complete with copper plate electrode 600 x 600 x 3.15 mm thick burried directly in ground earth pit not less than 2.25 mtr deep below ground level connected to & inclduing copper strip 20x3 mm by means of nuts and bolt check nuts and washers of galvanised iron sheet, passing through protection pipe of 25 mm dia light grade GI pipe all as shown in electrical plate Nos 3 of SSR Part-I, and connected to earthing test point complete inclduing testing filling of adquate quantity of charcoal dust and common salt inclduing necessary excavation, refilling earth and removal of surplus soil upto 50 mtrs apart and PCC 1:3:6 type C1 chamber precast RCC cover 40mm thick nrinforces with 6 mm dia MS bar 3 Nos both way with handle made out of 20 mm dia MS base water pipe with wire mesh, funnel etc and connecting testing etc complete all as specified and directed.
S and G Construction
M/s. Shree Shakti Enterprise
NILESH SUBHASH KARALE
KALIKAY ENTERPRISES
Venus Engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .