| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC KHASRA NO 145 GROUND FLOOR NEAR JAIN MOHALLA JATO KI CHOPAL VILLAGE KHERA KALAN NEW DELHI 110082 | NORTH | DELHI | 110082 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹42.3 L+₹3.9 L (10.0%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
26 Nov 2024, 6:00 pmClosed
CWE (AF) BHUJ
CWE (AF) BHUJ KHAVDA ROAD BHUJ KACHCHH PIN 370001
REPAIR/ REPLACEMENT AND PREVENTIVE MAINT TO THE HT SWITCH GEARS LIKE TRANSFORMER, VCB, RMU, VLE SWITCHES, RELAYS, ISOLATION TRANSFORMER AND HT UG CABLES AND OTHER CONNECTED ITEMS AT AFS BHUJ
2024_MES_681194_1
84237/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BHUJ
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) BHUJ
₹80,000
Yes
24 Dec 2024
25 Oct 2024
28 Nov 2024
25 Oct 2024
26 Nov 2024
14 Nov 2024
Amount
M & L for Dehydration and filtration of transformer oil / Voltage stabilizer / VLE switch & Isolation Transformer oil by using mobile dehydration and filtration plant of capacity of 12000LPH,heating and filtering the transformer oil to be carried out per minimum four hours till the di- electric strength reaches value of 45 KV or above in one minute, for any capacity of transformer/Voltage stabilizer/VLE Switch & Isolation Transformer (25 to 500 KVA/ VLE SWITCHES) Note:- Cost of T&P required for dehydration and filteration should be deemed to be included in the quoted rate. No extra cost will be permissible to the contractor in this regard.
Supply and topping / replacement of transformer oil having di-electric strength above 50 KV/mm of Transformer chamber and conservator with new transformer oil up to the required level in any type and capacity of transformer / Voltage stabilizer / OCB all as directed by EIC. Note : Transformer oil brought by the contractor at site shall be in seal packing drum having ISI mark as per IS 335/1983 of make Savita, Asian or equivalent.
M&L for Servicing of 11 KV GOD by cleaning the contact ,Pin insulator with CTC and applying the Patrollium Jelley at the contact point /down rod links for smooth operation including replacing the rusted /corroded bolts and nuts (using GI Nuts& Bolts)alongwith replacing the burnt aluminium thimbles and deffective insulator of GOD as required at site. Note:- 1. Insulator and male (moving)/female(fixed) contacts shall be measured and paid under relevant items. 2.The cost for replacement of aluminium thimbles. GI nuts,Bolts, wahers, lubricating materials etc shall deem to be included in the unit rate quoted by the contractor against this item
Supply only Male/Moving contact 11 KV 200 Amps
Supply only Female/Fixed Contact 11 KV 200 Amps
Supply only Copper Tinned Strip 11 KV 200 Amps Note: Cost of fixing for item No.4 to 6 is include in item No.3
M & L for Calibration of VCB / RMU relay by injecting High voltage through CTS checking the over load system of VCB upto 90 % rated load and artificial fault creation and setting of relay by 10 to 15 % of rated load removing u/s overload and earh fault relay including connection with power pack.Opening out the trolly checking the operation of VCB mechanically and electrically through shunt trip coil including energizing of springs automatically including checking of TNC switch.Testing and commissioning all as directed. Note:- (i) Maintenance to be carried out by the reps of authorised firm. (ii) After completion test certificate shall be furnished from firm.
M & L for maintenance of VCB / RMU11 KV, 400/ 630 /1200 Amps including removal of VCB trolley, cleaning of all copper male and female contact, tightening of all connections, checking of all auxiliary contacts, control wiring, servicing of relays, etc. refixing the VCB trolley to its original position including proper setting of manual/motorize operation of VCB, checking/setting of tripping system, etc complete. Note:- (i) Maintenance to be carried out the reps of authorised firm. (ii) After completion test certificate shall be furnished from firm.
S & F in replacement of Potential Transformer 11 KV / 110 V 50Hz of VCB all as directed by EIC.Make :CG/ ABB / L&T or equivalent
S & F in replacement of Current Transformer of VCB upto 200/5 Amps all as directed by EIC.
M&L for 11/12 KV 3.15 Amp, fuse links for distribution circuits (for use in VCB PT) suitable for VCB voltage Transformer unit fuse carries assembly. Make: GE /L&T/Siemens or equivalent
S & F of VCB spring Charging motor 24 Volts DC (as per site requirment) with gear assembly all as directed by EIC.
S & F of Power Pack for VCB control system of 230 Input and 24 Volts output with fuse protection all as directed by EIC. Make :MAX Power or equivalent
S&F TNC Switch for operation of VCB as per sample all as directed by Engineer- in - charge.
S & F in replacement of space heater, ISI marked suitable for 11KV VCB Panel/ RMU, complete all as directed.
S & F in replacement of thermostat suitable for 11 KV HT panel all as specified. Make: As per sample
S & F in replacement of Closing coil, ISI marked suitable for 11KV VCB Panel, complete all as directed.
S & F in replacement of tripping coil, ISI marked suitable for 11KV VCB Panel, complete all as directed.
S&F in replacement of vaccum inettupter 630/800 Amp suitable for HT VCB complete all as specified and directed
M & L for Maintenance / Servicing of Servo Voltage stabilizer by OEM rep of capacity upto 160 KVA 3 phase 440 volts 50 Hz including cleaning, checking oil level and brazing / soldering if required , replacement of control panel spare parts as electronic circuit card / volt meter / amp meter / Trigger Transformer etc of servo Voltage Stabilizer .checking each phase voltage, Testing and commissioning complete all as directed.( Note: Spare parts if required shall be paid separately)
S&F Electronic circuit card (PCB) all as specified and as directed by EIC.
S &F Voltmeter(Digital) all as specified and as directed by EIC.
S&F Amp meter with CT (Digital) all as specified and as directed by EIC.
S&F Trigger Transformer all as specified and as directed by EIC.
M & L for Shifting of Transformer / Isolation Transformer / Voltage stabilizer from one locationg to other location of any capacity including removing the existing HT/LT connection of any type transformer and transporting including to desired location within Airforce stn bhuj area including 308 TRU (mundra road). The same installing connecting HT/LT cables, Earthing testing and commissioning all as directed EIC.
S & F Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120 Sqmm 3 core all as directed.
All as per item No.27 above but of size 95 Sqmm 3 core
S & F Cable jointing kit for 11 KV (Earthed) grade cable for Straight through heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120 Sqmm 3 core all as directed.
All as per item No.29 above but of size 95 Sqmm 3 core
S & F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120 Sqmm 3 core all as directed.
All as per item No.31 above but of size 95 Sqmm 3 core
Taking out unserviceable / serviceable HT cables from excavated trenches, ducts, wall, pole etc including removing cable covers, sand, cable joints, pipes, clamps etc, taking out old serviceable cables for reuse and removing unserviceable cables, covers etc, for the sizes of cables 95 /120Sqmm all as directed by Engr- in -charge.
S & F of serviceable HT 11 KV 3 core 95 sqmm of size cable in trenches/fixed to poles/wall, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables( HT ), heavy duty with aluminium conductor, 11000 volts (earthed) grade all as specified and directed by EIC.
Relaying only of HT 11 KV 3 core 95/120 Sqmm cable in trenches/fixed to poles/wall, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable( HT ), heavy duty with aluminium conductor, 11000 volts (earthed) grade 95/120 Sqmm x 3 core all as specified and directed by EIC. Note for item No.34 & 35 : (i) Excavation, earthwork, cable joints, sand coushing & cable cover will be measured and paid separately if required
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in soft /loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick complete all as specified and as directed
Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all as specified and as directed
M & L for providing dry river sand as in cushioning to UG cables including gently punning down of sand in layers all as directed and specified. ( Note : For measurement purpose punned thickness shall be considered)
M & L for unreinforced precast concrete cable covers CLASS HV type I, flat size 300 x 180 x 40 mm laid transverse to cable all as directed and specified.
S&F in replacement 100 mm bore GI tubing, light grade for encasing cables for mechanical protection, laid under plinth/floors/ roads/ path /culverts or fixed on walls/on poles by means of MS clamps with necessary bolts, nuts and washers all as specified and directed.
All as per item No.41 above but 80 mm bore
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 4 Mpa working pressure.
M & L for erection of Precast HT cable route / cable path indicator,made out of PCC 1:2:4 ,type Bo,12.5 mm graded stone aggregates of size 100 Cm (Height) x 12 Cm (Width) x 8 Cm (Thichness), painted with orange colour lettering synthetic paint and letters 4 inch "DANGER,HT 11 KV CABLE" to be written with black colour lettering synthetic paint and embedded in PCC block 1:3:6 type C2 (using 40mm graded aggregate) of size 15cm x 15cm x 20cm including necessary excavation for PCC block c, placed at interval of every 30 M ,complete all as specified and as directed by Engr-in-Charge.
M & L for scrapping of old painted/oily surface of transformer/ isolation transformer/voltage stablizer including all nut bolts, channels by wire brush with cottan waste and painting with two coat of approved synthetic enamel paint as per the existing paint by sparay gun and writing SM No all as per ground condition as directed and specified by Engr-in –charge.
M&L for Painting of existing steel tubular 11 mtr long after preparing/Scrapping the metal surface with emery sheet in all respect for making smooth surface and painted with one coat of primer and two coats of synthetic enamel aluminium paint. upto 1.5 mtr from ground level. including painting with 30 cm height each in white and Red colour alternatively, total of 5 Nos connecting from the Top PCC coping and making pole No and feeder No with paint as per approved pattern complete all as specified and directed (Note:-The numbering shall be hand written only stencils shall not be allowed ,size of letter shall be 50 mm high and 10 mm wide.)
S & F procelain/epoxy insulators use in HT feeder pillar boxes as per sample all as specified and as directed.
S& F including Stretching binding of ACSR conductor on poles to the insulator by means of necessary binding wires 16 SWG aluminium wire complete with necessary jumpers and connections, complete all as specified and as directed.
S&F pin type Porcelain, vitrous, white, brown or green insulator including one galvanised mild steel spindle, washers, nut and bolts 150 mm height, 150mm dia for 11000 volts grade
S&F Disc type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, and nuts as under Working pressure 11000 volts,145 mm height, 255 mm dia ball and socket type two in series assembly for tension with tension clamps for conductors all as specified and directed.
S&F danger boards notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colur and fixed with M.S clamps, bolts and nuts of approved size, for HT 25 X20 cm size.
Dismantling steel poles/struts, any size complete all as specified and directed.
M&L for borewell earthing maint free with the help of mechanical boring machine of 150mm dia- 30 m depth, S&F 160mm dia(OD) UPVC pipe 6kg/Sqcm rating-30m long with the help of suitable size clamp with nut bolt and washers-01 No, S&F 30m 50mm dia GI pipe medium grade lowering in borewell with the help of T&P having suitable hole for providing good conductivity of earthing, M&L for providing 32X6mm GI strip upto 7.5 m long complete with protected with 40mm light grade GI tubing and connect with extng testing terminal block by screws and borewell earthing with the help of suitable size GI nut bolt and washersetc complete, M&L for charcoal dust, salt fill in borewell for earth conductivity. M&L for covering of borewell with PCC (1:2:4) type B-1/ brick masonary pit of size 45X45X45 cm complete all as specified and minimum earth result below 1 ohm to provide any chemical etc as required complete all as specified and directed by Engr-in- Charge
S&F in replacement of prestressed concrete pole, 11 metres long 152 mm x 152mm x at top and 152mm x 260mm at bottom class 9, erected in true vertical position in PCC work for foundation & Coping complete all as specified. (Note :- Excavation/earth work, etc shall be measured and paid separately under respective items of Sch "A")
S & F in replacement of mounting over four/two pole structure to vertically operated gang operating air break switch (GOD) suitable for 11 KV, 200 Amp consisting of 3 Insulators in each phase (Total 9 insulators in 3 Phase) mounted over the galvanised mild steel channel frame of suitable size, operating mechanism, operating handle made of medium grade galvanised Iron pipe of 25 mm dia, at least 5 mtr long, locking arrangement , connected with 7 leaver Godrez lock, moving and fixed contacts, copper jumphers including making electrical connections of all incoming and outgoing conductors all as specified and as directed by Engineer-in-charge.
S&F cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding , bending cold or hot, drilling holes for bolts, in any shape or size as indicated aor directed and inclusive of one primer coat, one under coat and finishing coat of paint
S&F Copper strip 20 x 3.15 mm including GI tubing light grade of size 40mm with saddles and fixing screws etc for jointing with transformer with the earth pit strip etc all as directed by engineer-in-charge complete.
S & F in replacement of drop out fuse assembly consisting of two post insulators with jaws mounted over suitable size of mild steel channel for each phase (Total 06 insulators mounted over three channels for three phase) including making electrical connections of all incoming and outgoing conductors all as specified and as directed by Engineer-in-charge.
M&L for complete cleaning of the internal & external parts of HT panel; checking & testing of all the components of the panel for cable insulation, lugs, connections and the like; replacement of & including provision of minor parts like lugs, insulation tape, nuts bolts, connectors and the like as directed by Engineer-in-Charge; replacement and / or welding of existing damaged hinges of the panel; preparation of old painted surfaces (internal & external) of the panel, complete removal of existing paint using emry paper grade 220, by sanding and scrubbing, application of corrosion resistant primer by sprayers, applying hammer finish metal paint using sprayers in two coats and till shining surfaces are obtained; application of two coats of epoxy black paint on panel frames, with locking arrangement including lock complete all as directed by Engineer-in-Charge.
Dismantling cross-arms of M.S. channel or angle sections etc. and taking down complete
M&L for Locating of fault in HT 11 KV cable of any size laid in trenches by hiring of electronic fault locating machine for finding out the fault of defective 11 KV HT cable at different locations including excavation of trenches for each fault at site by making sufficient space for working inside the trenches for jointing the cable and further excavation and refilling after connection and testing of straight through joint as per requirement complete all as specified and directed. Note :- (i)The fault located equipment will be brought at site within 02 days of Instruction received from Engineer-in-charge complete all as specified and as directed by Engineer-in-charge. (ii) Excavation, earthwork, cable joints, sand coushing & cable cover will be measured and paid separately if required)
Cutting and trimming tree branches along HT over head lines, after arranging electrical shutdown , including taking all precautions while working on lines using own T&P by the contractor. Note :- (i) Branches of trees shall be cut upto 3 metre from the outer conductor of OH line.Arrengement of tractor trolly to remove bushes from the site to out side the station is responsibility of contractor. (ii) Cutting/trimming of branches shall be done after obtaining necessary shut down in writing by the Engineer-in-Charge to avoid any casualty. (iii) Pole to pole span will be measured as one job.
M&L for painting of chain link fencing of sub stations with a height of 1.5 Mtr above ground level by two coat of aluminium paint and one coat of red oxide primer by sparay gun as per ground condition as directed and specified by Engr-in –charge. note;Painting of angle iron/gate shall also measured and paid seperately
M & L for Cleaning of transformer yard , four pole, two pole, three poleStructure complete as directed and spreading of crushed stone aggregate 40 mm grade
M & L for surface excavation not exceding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil including removing green vegetation, roots, bushes, etc from surrounding of LT Feeder Piller Boards./Poles/ substations etc. all as directed by Engineer-in- charge.
Dismantling of HT over head lines 3 wire span measured as one length ACSR conductor and Re- stretching of ACSR Conductor 3 wire of any size on HT over head line 11000 volts grade incl earth continuity wire incl bindng properly, replacement of jumper with existing / suitable size of ACSR conductor complete all as specified and directed.
Taking down ASCR conductor of any size complete all as specified and directed.
M & L for Painting of cross arm and MS channel , nut bolts, clamps etc on HT two Pole Structure of 11 Mtr Long after preparing/Scrapping the metal surface with emery sheet in all respect for making smooth surface and painted with one coat of primer and two coats of aluminium paint
M &L for Painting of cross arm and MS channel , nut bolts, clamps etc on HT four Pole Structure of 11 Mtr Long after preparing/Scrapping the metal surface with emery sheet in all respect for making smooth surface and painted with one coat of primer and two coats of aluminium paint.
Taking down Galvanised earth wire conductor of any size complete all as specified and directed.
S&F in replacement of guarding wire of Galvanised steel 4mm dia fixed on HT OH Lines complete all as specified and directed.
M & L for Stay assembly complete with all accessories is as shown in electrical plate No 1 (loop type insulators, stay clamp, excavation & concrete work shall be measured & paid separately) dia of stay rod 20 mm complete all as specified and directed.
S&F in repair Loop type isulator, vitreous porcelain, white, brown or green large size with overall dimension 90 x 140 mm clearance of hold 25.5mm complete all as specified and directed.
M&L for in repair for replacement of Galvanised stay strand, 7/4mm
S&F angle iron (Fe-310) as in posts, struts in fencing including cutting top to shape required, drilling holes, notching for wire etc complete all speciified and directed
Supply only 10 mm dia mild steel Gde E-250 plain round bars as in line wire for chain link fencing complete all as specified and as directed.
M&L for steel flat and including necessary drilling holes bolting or reveting etc and similar work complete conforming to Fe-290,Gde-E-165 complete all speciified and directed
Supply only MS screw, bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exceeding 5cm and not exceeding 10cm long and dia complete all speciified and directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails straining bolts, etc including provision of binding wire complete all speciified and directed
Supply only galvanised chain link fencing, any size or type, all as specified and directed.
M&L for one coats of synthetic enamelled paint over a coat of red oxide primer including preparation of new steel/iron surfaces exceeding 10cm girth.complete all speciified and directed
M&L for one coats of synthetic enamelled paint over a coat of red oxide primer including preparation of new steel/iron surfaces not exceeding 10cm girth.complete all speciified and directed
M&L for Frame work such as gates , including pintle hinges , stops , hand made sliding bolts , arrow heads etc conforming to Fe-290,Gde-E-165 complete all speciified and directed
M&L for plain cement concrete type C-2, 1:3:6 using 40mm graded aggregate in foundations, filling and mass concrete (for stay assembly) including necessary form work, complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone agg in foundation, filling and mass concrete complete all as specified and directed.
M&L for broken stone hard core of gauge n.exc 0.63mm deposited, spreed and levelled in layers n.exc 15 cm thick watered and rammed to a true surfaces.
M&L for block work with straight or curved on plan exc. 6m mean radius using old size bricks built in Cement Mortar (1:6) complete all as specified and directed.
M&L for cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces finished rough without using extra cement complete all as specified and as directed by Engineer-in-Charge. Note : WPC will be measured and paid separately.
Supply only integral water proofing compound complete all as specified & as directed by Engineer-in-Charge. Make : Pidilite/Sika
M/s Birja Nand (BID ID -3172577)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .