Loading…
Loading…
Tender Value
₹56.4 L
EMD Value
₹1.3 L
Closing Date
8 Oct 2026, 1:00 pm
Executive Engineer PD PWD Gopeshwar
Executive Engineer PD PWD Gopeshwar
Construction of 12 m span RCC culvert at Km 2 of Patal Ganga to Ganai-Molta motor road for Construction of 10 km road from Patal Ganga to Ganai-Molta 2 no bridge at km 5, i.e. 40m and 30m, and 2 at km 8, i.e. 25m and 20m) Under the State Plan in the
2026_pwd_100439_1
EE No- 2015/29 AC dt- 11-09-20216
Open Tender
Civil Works - Bridges
Item Rate
180 days
Gopeshwar
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,720
Executive Engineer PD PWD Gopeshwar
₹1.3 L
22 Sept 2026
22 Sept 2026
8 Oct 2026
22 Sept 2026
8 Oct 2026
22 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MOR | 232.32 | Cum | - | - |
| 2 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 - P.C.C grade M 10 Nominal mix 1:3:6 | 11.45 | Cum | - | - |
| 3 | Coursed rubble Stone masonry work (1st sort) In 1:4 cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 12 | 220.53 | Cum | - | - |
| 4 | Coursed rubble Stone masonry (1st sort) In cement mortar (1:5) for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 | 184.48 | Cum | - | - |
| 5 | Pointing with cement mortar (1:3) on Retaining/Breast wall as per drawing and technical specification Clauses 613.3 and 1204 | 196.51 | Sqm | - | - |
| 6 | Back filling of Granular material behind abutment, wing wall and return wall complete as per drawing and Technical specification | 187.2 | Cum | - | - |
| 7 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (For Height 5m to 10m) - For solid slab super-structure
RCC Grade M25 Using Concrete Mixer | 73.5 | Cum | - | - |
| 8 | Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications | 8.65 | MT | - | - |
| 9 | Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications | 7.43 | Cum | - | - |
| 10 | Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space | 24 | Rmt | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.90 MB
BridgeConditions.pdf
Tender Documents • 1.32 MB
BOQ_118410.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .