Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance SHOP NO 7 MCC BUILDING M G ROAD LALBAGH MANGALORE DAKSHINA KANNADA KARNATAKA 575003 | DAKSHINA KANNADA | KARNATAKA | 575003 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance SRRA 33 JAYASREE SURABHI ROAD ERNAKULAM ERNAKULAM KERALA 682024 | ERNAKULAM | KERALA | 682024 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹14,600
Closing Date
5 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HOD(Commercial.)
Travancore Titanium Products Limited Kochuveli Trivandrum
Condition monitoring and testing of 66kv and 11Kv Electrical Equipments.
2025_TTPL_751395_1
CD/CN/SC-38/ Monitrg Testg 66kv 11Kv Elect Equip/24-25 dated 15.03.2025
Open Tender
Miscellaneous Services
Service
Travancore Titanium Products Limited
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,416
Yes
₹14,600
Yes
17 Jun 2025
17 Mar 2025
8 Apr 2025
17 Mar 2025
5 Apr 2025
17 Mar 2025
17 Mar 2025 - 5 Apr 2025
Condition monitoring and Testing of 66kv and 11Kv Electrical Equipments.
Power Transformer (66KV/11KV, 5MVA. Off load) no need to change existing tap position 1. Tan delta test for Transformer winding and bushing (4 bushes in a transformer) 2. Winding resistance measurement ( HT side LT side) 3. Insulation Resistance test Polarization Index
Current Transformer ( 66KV , 150/1A 2 core ) 1. Capacitance & Tan Delta test 2. Insulation Resistance test 3. Polarization Index
Current Transformer ( 66KV , 70/1A 3 core ) 1. Capacitance & Tan Delta test 2. Insulation Resistance test 3. Polarization Index
Potential Transformer (66KV/110 Volt) 1. Capacitance & Tan Delta test 2. Insulation Resistance test 3. Polarization Index
SF6/MOCB (66kv 2500Amp) 1. Insulation resistance test 2. Breaker Timing Test 3. Contact Resistance measurement test
Vacuum circuit breaker test (11KV , 800Amp) 1. Insulation resistance test 2. Breaker Timing Test 3. Contact Resistance measurement test
Capacitor with series reactor(11kv 500kvar) 1. Capacitance and tan delta test 2. Insulation resistance 3. Power factor test by primary injection 4. Winding resistance
Distribution Transformer ( 11/0.415KV 2MVA off load, no need to change existing tap position) 1.Winding resistance measurement 2. Magnetic balance test 3. Insulation resistance test 4. Polarization index
Distribution Transformer ( 11/0.415KV 1MVA off load, no need to change existing tap position) 1. Winding resistance measurement 2. Magnetic balance test 3. Insulation resistance test 4. Polarization index
Alternator ( 1MVA , 11KV ) 1. Winding resistance measurement 2. Magnetic balance test 3. Insulation resistance test 4. Polarization index
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .