Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LRejected-Finance | L1 | Rejected-Finance REJECTED |
Tender Value
Refer Docs
EMD Value
₹50,607
Closing Date
23 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE E BSNL ED SML
The Executive Engineer E B.S.N.L., Electrical, Division, First Floor, Block no. 35, SDA Complex, Kasumpati, Shimla171009
Rate Contract for Repairing and servicing of various capacity DEA sets under the jurisdiction of BSNL Electrical Sub Division Dharamshala HP
2020_BSNL_52624_1
09/2020-21/SHIMLA/SHIMLA DIVISION
Open Tender
AMC/ Maintenance Contracts
Item Rate
720 days
DHARAMSHALA
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
AO BSNL SHIMLA
₹50,607
29 Apr 2021
9 Jul 2020
28 Jul 2020
9 Jul 2020
23 Jul 2020
9 Jul 2020
90 days
Amount
Attending and rectification of EA 7.5 KVA to 30 KVA set faults including providing minor spares if reqd such as connecting copper wires, removing air from fuel pump, control fuse, ferrules, lugs i/c minor works etc etc alongwith testing & commissioning etc. in URBAN site complete as required. (Item will be measured on submission of visit report duly signed by BSNL authority and allowed at once per site per fault) (Note:- For subsequent visit to attend the DG set to provide the items hereunder will not be paid separately. It is assumed that all items as below shall be carried out by firm in first visit only)
Attending and rectification of EA 7.5 KVA to 30 KVA set faults including providing minor spares if reqd such as connecting copper wires, removing air from fuel pump, control fuse, ferrules, lugs i/c minor works etc etcalongwith testing & commissioning etc. in RURAL/TRIBAL site complete as required. (Item will be measured on submission of visit report duly signed by BSNL authority and allowed at once per site per fault) (Note:- For subsequent visit to attend the DG set to provide the items hereunder will not be paid separately. It is assumed that all items as below shall be carried out by firm in first visit only)
Carrying out 'B' Check servicing of following capacity E/A sets located at various T.E. Bldg / BTS including replacement of old engine oil, fuel filter, lubricating oil filter etc. by new as per manufactures recommendation including arranging vehicle, transportation, manpower, tools and tackles, testing etc. as required. (Oil, filters shall be manufacturer recommonded specs) (Note:- This item includes visit charges, nothing extra on this account shall be paid)
Carrying out 'B' Check servicing of following capacity E/A sets located at various T.E. Bldg / BTS including replacement of old engine oil, fuel filter, lubricating oil filter etc. by new anti freez lubricating oil as per manufacturer recommendation including arranging vehicle, transportation, manpower, tools and tackles, testing etc. as required. (Oil, filters shall be manufacturer recommonded specs) (Note:- This item includes visit charges, nothing extra on this account shall be paid)
Supplying of good quality Antifreeze coolant (ethylene glycol) suitable upto -40 deg Celcius ( Only for Lahoul/Spiti/Kinnaur/Pangi area)
Replacement of following faulty items in the existing DEA set(s) complete with connections, testing etc. all as required.
Coolant.
Battery Leads (Flexible) of length not less than 0.6 Meters with terminals.
6 Sq. mm. Multi-strand Copper Cable.
Flexible wire braided fuel pipe.
Benzo Bolts.
RPM cum hour meter (mechanical) without cable.
SMPS 12 volt, 10 Amp Battery Charger
SMPS 12 volt, 15 Amp Battery Charger
Triple Pole 32A 415 V Contactor (2NO+2NC).
110 Ah, 12 volt maintenance free Battery (M/s Exide FXPO-XP1100 or Equivalent of a approved. Make)
130 Ah, 12 volt maintenance free Battery (M/s Exide FXPO-XP1300 or Equivalent of a approved. Make)
150 Ah, 12 volt maintenance free Battery (M/s Exide FXPO-XP1500 or Equivalent of a approved. Make)
180 Ah, 12 volt maintenance free Battery (M/s Exide FXPO-XP1800 or Equivalent of a approved. Make)
Solenoid switch
Engine start relay
Repairing & Servicing of 12 volt self starter i/c replacement of solenoid coil, cleaning, lubricating teeths etc. complete with testing as required.
Up to 30 KVA.
Above 30 KVA & Up to 63 KVA.
Above 63 KVA & Up to100 KVA.
Above 100 KVA & Up to150 KVA.
Replacement of V-Belt(s) of following capacities DEA set complete as required.
Replacement of AVR of DEA set(s) complete with interconnections, testing etc. all as required.
Up to 15KVA
20KVA to 35KVA
50KVA to 63 KVA
100KVA to 150 KVA
Replacement of on load Changeover switches of following capacities i/c interconnections, testing etc. all as required.
Four Pole 40A (MCB type).
Four Pole 63A (MCB type).
Four Pole 32A with side handle with SS enclosure.
Four Pole 63A with side handle with SS enclosure.
Repairing of control wiring of existing AMF control panel of DEA set i/c repairing/ replacement of damaged wiring with same rating and size of Cu. Wire for effective control working complete all as required. (Without replacing of faulty parts)
Repairing of control wiring of existing Conventional control panel of DEA set i/c repairing/ replacement of damaged wiring with same rating and size of Cu. Wire for effective control wiring complete all as required. (Without replacing of faulty parts)
Calibration of fuel injection (FI) pump i/c dismentalling the fuel pump, cartage to the service station and refixing the same i/c injector timing & tappet setting, testing etc. complete all as required. (Note: Pump caliberation only from authorised dealer with test report)
Up to 2 Cylinder engine(s).
Up to 4 Cylinder engine(s).
Up to 6 Cylinder engine(s).
Rewinding of the Charging alternator of the DEA set complete with testing, fixing etc. complete as required.
Repairing of 10/15/20 KVA rating, Single/Three phase, 230Volt / 415 Volt, 50Hz, 0.8 PF alternator assembled with diesel Engine i/c dismentalling the alternator, rewinding of stator and exciter, field winding and rotor assembly, reassembling with Engine after rewinding (i/c carriage to workshop for rewinding) and making proper alignment, making interconnection, testing on load etc. complete as required at site.
Stator winding.
Rotor winding.
Rewinding of excitor and field winding.
Alternator Diode assy
Alternator Rectifier assy
Repairing of 30/35/63 KVA rating, Three phase, 415 Volt, 50Hz, 0.8 PF alternator assembled with diesel Engine i/c dismentalling the alternator, rewinding of stator and exciter, field winding and rotor assembly, reassembling with Engine after rewinding (i/c carriage to workshop for rewinding) and making proper alignment, making interconnection, testing on load etc. complete as required at site.
Stator winding.
Rotor winding.
Rewinding of excitor and field winding.
Alternator Diode assy
Alternator Rectifier assy
Replacement of faulty coupling(s) with new one in following rating DEA set(s) i/c allignment, testing etc. complete as required.
Painting of DG set(s) of following capacities {Complete Engine, Alternator and Control Panel (Exterior only) and Canopy from Inside & outside} in-installed position with two coats of spray painting with synthetic enamel paint and two coats of primer of the color & brand approved by Engineer-in-Charge to give an even shade, including cleaning of surface after scrapping the rusts/ loose/swallowed/ old paints wherever appears including degreasing with detergent and refilling the gap with putty etc. complete as required.
Upto 30 KVA .
Dismentling the Fuel tank from canopy & Cleaning the tank & refixing the same i/c making the connection of fuel line complete as required at site.
Dismentling the Fuel tank from canopy & trasporting the same up to nearest welding workshop for rectification of leakge in the tank , & refixing the same i/c cleaning & making the connection of fuel line complete as required at site.
Credit for following old existing unsevicable batteries irrespective of make and model available at site.
Upto 110 AH, 12 Volt
110 AH-130, 12 Volt
131 AH & Above, 12 Volt
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .