Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC 31 A K ROAD AGARTALA | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | ₹22.9 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical JOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | - | - | Rejected-Technical RES |
| 3 | Rejected-Technical | - | - | Rejected-Technical RES |
Tender Value
₹30.6 L
EMD Value
₹61,155
Closing Date
31 Aug 2023, 3:00 pmClosed
Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Providing, Installation and Commissioning of Air Conditioning system at Gomati District Hospital Udaipur, Tripura
2023_CEPWD_41011_1
32/B/DNIeT/SE-IV/PWD(RandB)/20
Open Tender
Electrical Works
Works
180 days
GOMATI
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹61,155
12 Dec 2023
17 Aug 2023
31 Aug 2023
17 Aug 2023
31 Aug 2023
17 Aug 2023
Amount
Providing,Installation,Testing & commissioning of Variable Refrigerant Flow (VRF) System Outdoor units of AC machines minimum capacity of 16 HP or 12.8 TR each top discharge, Modular type only cool, next generation VRF, each outdoor unit comprises of 100% inverter Driven Hermetically sealed Scroll Compressors, air cooled condenser with protective coated fins heat exchangement corrosion fin factory coated propeller type fan with motor, specially designed ODUs with refrigerant cooled heat sink , nonstop working at 56 degree C, with R410A or equivalent Refrigerant, working on 3-phase AC range of 380 volt to 420 (±5%)Volt, 50Hz , the outdoor unit should contain error code LED display for ease of operation, auto addressing setting refrigerant cool PCB, Electronic expansion Valve, microprocessor controller, VRF unit should be compatible with AHU/TFA etc. complete as per direction of the Engineer-in-charge.
Providing , Installation, Testing & commissioning of Variable Refrigerant Flow (VRF) System type inddor unit comprising of Copper coil section, filter section, micro processor type PCB , the unit shall be ceiling suspended type and complete with all standard accessories etc. complete as per direction of the Engineer in charge VRF High Wall unit Capacity minimum 2 TR.
Providing , Installation, Testing & commissioning of Variable Refrigerant Flow (VRF) System type indoor unit comprising of Copper coil section, filter section, micro processor type PCB , the unit shall be ceiling suspended type and complete with all standard accessories etc. complete as per direction of the Engineer in charge VRF High Wall unit Capacity minimum 1.5 TR.
Providing , Installation, Testing & commissioning of Variable Refrigerant Flow (VRF) System type indoor unit comprising of Copper coil section, filter section, micro processor type PCB , the unit shall be ceiling suspended type and complete with all standard accessories etc. complete as per direction of the Engineer in charge VRF four way Cassette unit Capacity minimum 2 TR.
Providing & Installation of Remote Controller Compatible of VRF indoor Unit, Cordless controller etc. complete as per direction of the Engineer-in-charge.
Providing & fitting fixing of copper individual Refnet Y distribution joint IDU etc. complete as per direction of the Engineer-in-charge.
Providing & fitting fixing of copper individual Refnet Y distribution joint ODU etc. complete as per direction of the Engineer-in-charge.
Supply, installation, testing & commissioning of in/c vaccumiazation and Nitogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRF/VRV system, complete with fittings with suitable adjustable ring type hanger supports, joining/ brazing in/c accessories insulated with XLPE Class O tubular insulation / with Classs O clossed cell elastemetic nitrile rubber tubular sleeves sections of specified thickness as below for suction and liquid lines, all accessories as per specification etc. as required complete as per direction of the Engineer-in-charge. 6.4 mm dia.(OD) (Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation
9.5 mm dia. (OD) (Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia. (OD) (Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation.
15.86 mm dia (OD) (Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation.
19 mm dia. (OD) (Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation.
22.2 mm dia (OD) (Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation
28.58 mm dia. (OD) (Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation.
Supply, installation testing & commissioning of rigid PVC pipe (for drainage of water from IDU) complete with fittings, supports as per specification and duly insulated with 6 mm thick closed cell Nitrale Rubber insulation ) 25 mm with 6 mm thick Nitrale Rubber insulation.
32 mm with 6 mm thick Nitrale Rubber insulation.
Supply & laying of Copper conductor scheduled flexible communication cabling between ODU and IDU as per OEM specification (VRF) cable shall be laying through hard PVC conduit pipe etc complete as per direction of the Engineer-in-charge.
Supply & fitting fixing of G.I. Cable Tray for laying of copper pipe support along with fittings as per required size 150mm etc complete as per direction of the Engineer-in-charge.
Supply & filling of First charge of refrigerant R410 A etc. Complete as per direction of the Engineer-in-charge.
Providing & connecting Electric control cables between indoor & outdoor, Machine room Supply point to indoor machine suitable cable for 3-phase line in/c Neutral etc complete as per direction of the Engineer-in-charge.
Providing & installation Outdoor structure or CC Pedestal complete as per direction of the Engineer-in-charge.
Cutting of existing ceiling for laying of refrigerant pipe in different places of the building and repairing the same by gypsum board, aluminium channel etc. in/c painting as same to same of existing ceiling complete as per direction of the Engineer-in-charge.
R.P.ELECTRONICS
R.S.COOLING AND ELECTRICAL SERVICE
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_41644.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .