Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹1.4 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹1.5 Cr+₹8.6 L (6.16%)Rejected-Finance PLOT NO 52 SIDDARTH PARK BEHIND ICE FACTORY RAVALWADI BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | ₹1.5 Cr+₹8.6 L (6.16%) | L2 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
1 Feb 2021, 6:00 pmClosed
CWE (AF) BHUJ
CWE (AF) BHUJ KHAVDA ROAD BHUJ KACHCHH PIN 370001
PROVN OF STN BRIEFING HALL AT 49 WG AT AF STATION NALIYA
2020_MES_368790_2
85221/E8
Open Tender
Civil Works
Lump-sum
365 days
NALIYA
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
GE (AF) NALIYA
₹2.1 L
Yes
8 Mar 2021
11 Jan 2021
3 Feb 2021
11 Jan 2021
1 Feb 2021
25 Jan 2021
Amount
NOTE: Schedule ‘A’ Part - I to XI are under Ser No. 1 to 11 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the tenderer for BUILDINGS /STRUCTURES as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the tenderer for EXCAVATION AND EARTH WORK as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for DISMANTLING/DEMOLITION as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIFICATION, AIR CONDITIONING & PVC CONDUIT as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for FIRE ALARM as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for ROAD/PATH/CULVERT as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-X
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-XI
SCHEDULE `A' PART-XII MISCELLANEOUS ITEMS OF WORK (Note for items 12.01 to 13.31. The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES)
S & F Air Circulator wall fans 230 volts single phase oscillating 450mm sweep and fixing on Wall/ Wodden Panel with necessary base plate and clamps as required complete all as specified and as directed. Make: Havells, Model: V3 or its equivalent in Bajaj/ CG as approved by GE
M & L for 60mm thick rubber moulded precast concrete interlocking paver block factory manufactured any shape and size confirming to IS 15658-2006 of M-35 Grade, without correction factor for chamfering, casted with grey cement and top layer with white cement and pigment casted in rubber mould with 0.50mm thick scratch proof lacquer coating on top laid dry in floor, pavement, etc over and including 25mm thick sand cushioning all as specified and directed.
Supply and Lay factory made unreinforced precast concrete cable cover LV Type II with flat size 300X180 X 40mm
M & L for Disconnecting the HT and LT Connections from the existing Transformer of any rating 160 kVA from exisiting MRS and shifting the same to MES store yard complete all as specified and as directed.
Supply and installation of copper wound transformer of capacity 200 kVA step down, indoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:2026 complete all as specified and as directed.
Supply, jointing and testing indoor type cable termination (heat shrinkable) suitable for 3 core, 11 KV / underground electric cable, XLPE cable of size 95 sqmm complete all as Specifeid and directed.
Supply & lay in trenches / duct/passing through pipe or fixed on pole and connecting and testing XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 120 sqmm 3.5 core complete all as specified and directed by EIC. Note: Excavation earthwork, cable covers, sand cushioning and GI protection pipe shall be measured and paid separately.
All as per item No.12.07 above but of size 25 sqmm 4 core
M & L for LT Panel board made out of CRCA sheet 2.0 mm thick Indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 200 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: Incoming: a) MCCB 100 Amps, 4 Pole adjustable type Thermal & Magnetic 25 kA - 01 No. b) Onload Changer over 4 Pole 100 Amps - 01 No. Outgoing: c) S&F MCCB of 4 Pole 40 Amps, 25 kA, with adjustable thermal and fixed magnetic protection - 04 No. (for Bldg, AC Plant-1, Plant-2 and spare) d) LED type Intelligent Panel meter to measure voltage, current, frequency, power actor, kWH, etc with all connected CTs of Class 1.0 e) LED indicating lamps with colour Red, Yellow, Blue, Mains ON, Stand by ON - 05 Set
AIR CONDITIONING
Supply, Installation, Testing and Commissioning of Floor Standing type 11 TR AC Machines which includes 4400 CFM Air Cooled Packaged AC with Scroll Compressor,Micro-processor Control Panel with Inbuilt Logic with LCD display, Centrifugal forward curved, Double Inlet, Double Width, R22 GAS refrigerant Power Supply of 415 V,3 Phase: double rubber pad, Nitrogen Pressure testing at 500psig hold for 48 hours and vacuuming the system at 500Micron, R 22 a Gas Charging as per Blue star or company guide line, Air Balancing with CFM & Temperature Measurement at each outlet. , APPROVED MAKES: BLUE STAR OR ITS EQUIVALENT
M & L for Hard Copper piping with proper supporting which includes: Anchor Fasning, Threaded Rods, MS angle/flat support Maximum distance is 2Mtr with all the necessary accessories, Size and Gauge of Copper pipe should be as per manufacturer's guide line APPROVED MAKES: PARASMANI/MANDEO/TOTAL LINE
M & L for 40MM PVC Thick pipes with necessary fitting with 9 mm thk.Nitrile Rubber Insulation with UV protected Al. Foil on sun exposed pipe APPROVED MAKES: ASTRAL/SUPREME/FINOLEX
S & F Testing and Commissioning of /Communication Cabling between IDU & OD Make: As per OEM of Airconditioner
M & L for Canvass connection with zip to measure machine outlet temperature and CFM
S & F Testing and Commissioning of Armored 4C x 16 Sqmm Cu Power Cable from HVAC Panel/Voltage Stabilizer to Each Packaged Indoor unit all as directed by EIC. Make Havell's/Polycab/Finolex
Outdoor Condensing Unit MS stands of adequate weight-bearing capacity, of min. 200mm height from finished floor level, or higher as per site condition. Rates to include double rubber pads & galvanized MS plate for each leg all as directed by EIC.
M & L for 20G GI, air-tight ducting & plenums fabricated out of prime quality 120 GSM GI sheets. Complete with necessary supports, expansion fasteners, Scaffolding to hang the duct etc. (ALL DUCTING SHOULD COMPLY WITH BIS CODE) APPROVED MAKES: GI SHEETS: JINDAL/ESSAR/INDIAN STEEL including Minor Civil work & Duct design
All as per item No.13.08 above but 22G GI Ducting
All as per item No.13.08 above but 24G GI Ducting
S&F Nitrile Insulation 9MM Thick closed-cell Elastomeric Nitrile rubber insulation of 40-60 kg/cumt density. Pre-clean duct surface before applying insulation. Stick insulation material using a thin film of manufacturerrecommended adhesive on both duct and insulation; keeping the insulation material under compression (without any stretching). Seal all joints air-tight.Thickness mentioned is minimum thickness. APPROVED MAKES: SUPREME/ARMACELL/A FLEX
S&F Acoustic Insulation Of Ducts with 12MM Thick Fiberglass of density 48 Kg/ Cu. M. & covered with RP Tissue & 28 G Perforated Aluminum sheet from inside of the duct. APPROVED MAKES: KIMMCO/UP TWIGA
S & F SA/RA Grill APPROVED MAKES:AIRMASTER/CARRYAIRE/COSMOS/DYNACRAFT/TROX/SACHINS/SYSTEM AIR/MAHESHWARI
S & F Volume Control Damper AIRMASTER/CARRYAIRE/COSMOS/DYNACRAFT/TROX/ SACHINS/SYSTEM AIR/MAHESHWARI
S & F Duct Damper APPROVED MAKES: AIRMASTER/CARRYAIRE/COSMOS/DYNACRAFT/TROX/SACHINS/SYSTEM AIR/MAHESHWARI
S&F Ms Fabrication for Duct Supports, Flanges all as directed by EIC
M&L for electrical distribution board for PU comprising of incoming isolator and outgoing MCB as per machine manufacturer requirement complete all as specified and directed.
S & F false ceiling with LED Square (2x2 feet) recessmounting powder coated white CRCA full glow LED panel downlight of 36 Watt Warm White fitting with LED lights complete alongwith necessary connecting cable of PVC insulated 3 core 0.5sqmm from fitting to ceiling rose/ connector complete all as specified and directed. Make: Havell's Model No.VENUSNEOHE2X2PLR18-42WLED830MOD or equivalent make from CG/Phillips/Bajaj
S & F slim LED tube light batten of wattage not less than 20 Watt, 2000 Lumen (4 feet long) white/brown colour, fixed to wall/ ceiling alongwith necessary fixing screws, etc. complete all as specified and as directed. Make: Havell's Model No.LUMILINEPLUSBS2OWLED865SPCSS or equivalent make from CG/Philips/BAJAJ
S & F slim LED tube light batten of wattage not less than 9 Watt, 1000 Lumen (2 feet long) white/brown colour, fixed to wall/ ceiling alongwith necessary fixing screws, etc. complete all as specified and as directed. Make: Havell's Model No.LUMILINEPLUSBS9WLED830SPCWH or equivalent make from CG/Philips/BAJAJ
S & F false ceiling with LED Square (1x1 feet) surface mounting powder coated white CRCA full glow LED panel downlight of 15 Watt Warm White fitting with LED lights complete alongwith necessary connecting cable of PVC insulated 3 core 0.5sqmm from fitting to ceiling rose/ connector complete all as specified and directed. Make: Havell's Model No.PLUTOSURFACE1X1PLS15WLED840S or equivalent make from CG/Phillips/Bajaj
S & F Exhaust fan,300 mm sweep 240volts, single phase, complete with Iouvers shutters,including provision of flexible three core PVC insulated copper conductor cable 23/0.0076" from ceiling rose to fan and grouting 4 Nos full threaded bolts and nuts etc complete of make-Havell's Model No.Ventil air-DSP, Bajaj/CG or equivalent.
S & F ceiling fan 230 volts, single phase of 1200 mm sweep including stepped type electronic fan regulator, flush type complete all as specified and directed. Make: Havell's Model-ES NEO
S & F MCB DB TPN 440 volts 8 way IP 42 protection double door rated busbar all as directed
S & F MCB DB SPN 240 volts 4 way IP 42 protection double door rated busbar all as directed
S & F MCB TPN of 440 volts,63 Amp capacity, "C" series
S & F MCB SP of 240 volts,5-30 Amp capacity, "C" series
S & F MCB SPN of 240 volts,40 Amp capacity, "C" series
S & F LED street/bldg light with bracket, powder coated, white CRCA full glow LED of 15 Watt Warm white fitting with LED lights with IP 66 complete along with necessary connecting cable of PVC insulated 3 core 0.5 sqmm from fitting to ceiling rose/connector complete all as specified and directed. Make-Havell's Model No.ENDRAPFARLSL15WLED757SASYTOPC or equivalent make from CG/Philips/BAJAJ
M & L for sub main wiring with four runs of 6 sqmm single core, FRLS PVC insulated but unsheathed multistranded copper cable 1100 volts conductor drawn through and including concealed heavy duty 25mm dia PVC conduit with all accessories and two runs of 6 sqmm FRLS PVC insulated but unsheathed multistranded copper conductor cable as earth continuity wire in complete all as specified and directed. Note: Four runs of main cable and two run of earth cable including one run of conduit shall be measured as one unit
M & L for sub main wiring with two run of 4 sqmm single core, FRLS PVC insulated drawn through and including concealed heavy duty 20mm dia PVC conduit with all accessories and one run of 4 sqmm FRLS PVC insulated but unsheathed multistranded copper conductor cable as earth continuity wire in complete all as specified and directed. Note: Two run of main cable and one run of earth cable including one run of conduit shall be measured as one unit
KALIKAY ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .