Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹19.4 L+₹66,180 (3.53%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹21.8 L+₹3.1 L (16.4%)Rejected-Finance G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA 390 002 | VADODARA | VADODARA | GUJARAT | 390002 | L3 | Rejected-Finance Being L3 |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
7 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BARODA
GE AF BARODA PO MAKARPURA BARODA 390014
REPAIR/MAINTENANCE OF HT DISTRIBUTION SYSTEM AND ITS CONNECTED ITEMS AT HARNI CAMP AND AIRFIELD AT AF STN BARODA
2020_MES_351219_1
8568/E8
Open Tender
Electrical Maintenance Service
Item Rate
270 days
GE AF BARODA
AS PER NIT AND TENDER DOCUMENTS
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹46,000
Yes
12 Aug 2020
9 Jun 2020
10 Jul 2020
9 Jun 2020
7 Jul 2020
24 Jun 2020
11 Jun 2020 - 16 Jun 2020
60 days
Amount
M&L in repair of straight through joint outdoor type for HT underground cable including jointing kits heat Shrinkable type suitable for cables of size upto 95 sqmm complete all as specified and directed.
Supply and fix in repair of cable jointing kit for 11 KV grade cable for outdoor termination heat shrinkable type joint with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
Supply and fix in repair of cable jointing kit for 11 KV grade cable for indoor termination heat shrinkable type joint with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
M & L cement concrete 1:3:6, type C2 using 40 mm graded stone aggregate for foundation filling and mass concrete complete all as specified and directed.
M & L cement concrete 1:3:6, type C1 using 20 mm graded stone aggregates for pedestal of poles, all including necessary form work, fair finishing to the exposed surfaces using extra cement complete all as specified and directed.
M & L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat of red oxide and two finishing coat of aluminium paint including dismantling of existing old cross arms/ bracing supposts/clamps/back plates or any structural sections including removing nuts, bolts, washers etc complete all as specified and directed
M & L for unbinding of the ACSR conductor from the insulator on pole (all lines existing in the span) re-stringing the conductors tighening HT over head line, jumper, screws nuts, bolts and binding to the insulators using required size aluminium binding wire complete all as specified and directed.
Supply & fixing in replacement of ACSR jumpers at disc by new one and tightening of jumper with 'D' type clamp/connector for fixing/tightening of two conductors of equal or unequal size all including treatment of connector and conductor with connector jelly, all as specified and as directed.
Supply and fix in repair loop type insulator, porcelain vitreous, white/brown/green, large size, with over all dimension 90 X 140 mm and clearance of hole 25.5 mm including insulator bolt, washers & nuts complete all as specified and directed.
Supply and fix in repair disc type insulator porcelain vitreous white/brown/green 11000 V grade, 145 mm height 255 mm dia ball and socket type single disc assembly for tension with tension clamp for conductor working pressure 11000 Volts complete all as specified and directed.
Supply and fix in repair pin type insulator, porcelain vitreuos,white/brown/ green, including one galvanised mild steel spindle two galvanised iron washers, one galvanised iron nut suitable for 11000 volts grade & of size 150 mm dia and 150 mm height, ISI marked all as specified and directed.
M&L in repair for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts grade, cross sectional area 95 sqmm, 3 core complete all as specified and directed.
M&L for GI tubing light grade for protection of cable fixed in wall or laid in trenches for the following size of pipes:-
80 mm bore
50 mm bore
M & L for Servicing and maintenance of Gang operated switch and drop out fuse assembly tripole pole, by applying white petrolium jelly, greasing the operating mechanism, drop out fuse assembly (set of three) repairing complete spare parts by replacing with new spares suh as worn out male contact (moving blade contact), Female contact (fixed jaw contact), post insulators, copper/aluminium jumper, arcing horn, operating pipe of GI 20/25 mm dia 'B' class medium grade, pipe guide, locking arrangement, operating lever, fixing of appropiate HT fuse element, nut bolts etc and making the GOD functional complete all as specified and as directed. Note: Contractor should take prior permission for shutdown in writing for carrying out maintenance of GOD to avoid any accident.
M&L in repair of straight through joints (epoxy) for LT underground cable heat shrinkable including joint kits and labour complete for making joints suitable for aluminium conductor for size of cable from 25 sqmm to 50 sqmm complete all as specified and directed.
Description all as per item No 15.00 above but suitable for size of cable 70 to 95 sqmm
Description all as per item No 15.00 above but suitable for size of cable 120 to 150 sqmm
M&L in repair of air break switch gang operated triple pole mechanically operated, mounted on insulator and steel frame, with operating mechanisum worked from ground level for current rating upto 200 Amps, 11000 Volts and testing on load complete all as specified and directed.
M&L in repair of air break insulator (DO assembly) for current rating upto 200 Amps, 11000 Volts and testing on load complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exeeding 1.5 m in depth and getting out in soft/loose soil for removing/laying of cable etc as directed by Engineer-In-Charge.
Returning, filling in excavated soil in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each all as directed by Engineer-In-Charge.
Removing surplus excavated soil to a distance not exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M & L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable all as specified. Note : Punned thickness shall only be measured and paid.
Supply and laying unreinforced Precast concrete cable cover,Class HV type 2 flat size 300mmx180mmx40mm all as directed.
M&L for taking down carefully transformer any capacity (100 to 315 KVA), any make & any type, from pole or plinth, by disconnecting HT & LT sides, earthing, supporting angles / cross arms, etc.; Opening of top cover; material and labour for replacement of all joints / types of gaskets HV/LV side ( top, fins, conservator tank, HV cable box, LV cable box, rediator, etc.); material and labour for replacement of HV & LV oil plug and oil filling plug; replacement of worn out major parts (except for supply of the major parts, which shall be measured and paid for separately as 'Supply Only), reassembling the transformer, testing, installing and recommissioning to its original place ie. on pole / plinth including connecting up HT & LT sides, earthing, supporting angles / cross arms, etc., testing the transformer and preparing report and monitoring proper record, complete all as directed. Note: (i). Rate quoted by the contractor is deemed to include for material and labour for replacement of minor parts such as nuts, bolts, lugs, etc. (ii) Only registered / authorised transformer repairing team of the manufacturer shall be deployed by the contractor to carry out work under this item. (iii) Supply only item shall be measured and paid seprately under respective item. However, fixing element of supply only items deemed to be included in the quoted rate of this item
Supply only HV Bushing ( of make used by original manufacturer of transformer)
Supply only HV complete metal parts with studs ( of make used by original manufacturer of transformer)
Supply only LV Bushing ( of make used by original manufacturer of transformer)
Supply only LV complete metal parts with studs ( of make used by original manufacturer of transformer)
Supply only Explosion Vent Diaphragm with Gasket. ( of make used by original manufacturer of transformer)
Supply only Oil Level Gauge – Flush Type. ( of make used by original manufacturer of transformer)
Supply only Temperature Gauge with seal. ( of make used by original manufacturer of transformer)
Supply only Marshalling Box Glass. ( of make used by original manufacturer of transformer)
Supply only Silica Gel Breather with assembly. ( of make used by original manufacturer of transformer)
Supply only Inspection chamber and top led gasket. ( of make used by original manufacturer of transformer)
Supply only Tap changer Switch assembly with Oil Seal. ( of make used by original manufacturer of transformer)
Supply only Conservator oil level glass and gasket. ( of make used by original manufacturer of transformer)
Supply only HV / LV copper Coil up to 315 KVA per phase ( of make used by original manufacturer of transformer)
Transportation of transformer carefully, any capacity(100 - 315 KVA), including lifting, loading and unloading, from site of work/ power house to workshop and back after completion of work in workshop, complete with all safety measures all as directed. Note:(i) The transportation shall be to any distance within municipality limits of Baroda. (ii) Rates of Hydra for lifting transformer at both the places(Site and workshop) both time pre and post repair is deemed to be included in quoted rates.
Dehydration & filteration of transformer oil by using mobile dehydration & filteration plant, heating and filtering the oil shall be carried out till the di-electric strength reaches value 40 KV or above in one minute, for any capcacity of transformer (63-315 KVA)/stablizer of any type & any capacity complete all as specified and directed.
M & L for topping up/replacement of transformer oil of transformer chamber and conservator with new transformer oil upto a required level of 50 KV di-electric strength to withstand for one minute in any type and capacity of transformer all as specified and directed.
M & L for hiring of Fault Locator Machine Vehicle complete from the authorised supplier alongwith their dedicated specialised team; finding out the exact HT/LT fault location from both end terminations of underground cable including necessary excavation and earth work complete all as directed.
M & L for scrapping/cleaning of outer surfaces of transformer and spray painting with two coats of best quality synthetic enamel paint over one coat of red oxide primer complete including writing of MES No.(stancil cut) all as directed by Engr-In-Charge from 63 KVA to 315 KVA capacity transformer of any make and size at plinth mounted or pole mounted on site complete all as specified and directed.
Trimming branches of trees of any length and size, bushes, hurbs around over head line and coming in contact with conductor including removal of tree branches etc to a distance not exceeding 50 mtr from over head line all as specified and directed (length of each span is approximately 30 to 50mtrs)
Dismantling of HT VCB trolley 11 KV 400 Amps of any make and type from existing site, Opening/drawing out the VCB trolley after switching off electric supply, testing and maintenance of VCB panels installed including the following works :- (i) Checking of all mechanical/electrical control systems for proper functioning including spring charging system, tripping system, indication system, vaccum interrupter; cleaning & servicing the fixed/moving contacts & blowing out dust and applying the proper lubrication/greasing complete, (ii) checking of Contact Resistance (RYB) and Auxiliary Supply voltage of closing coil, tripping coil, Motor; cleaning & servicing for proper functioning (iii) Timing Test of closing time and opening time, IR value with 5 KV megger before and after HV, (iv) Checking of PT & CT which shall include ratio test and healthiness of the HT and LT fuses and associate circuiting. (v) Breaker testing which inclueds (a) Insulation resistance, (b) Pick up and drop of operating coils, (c) To check IR Values(CT) (d) To carryout polarity test(CT), (e) to check Knee point voltage/ measurement in case of class PS CT (vi) Servicing of HT, 11 KV, VCB, 400 Amps capacity, 50 Hz, breaking capacity 50 KA by drawing out from moving contacts for smooth funcitoning including replacement of tripping and closing coils, 30 volts, DC and servicing of solenoid switch, all as directed, (vii) Dismantling of unserviceable bus bar bushing from existing 11 KV bus bar chamber and supply and fix new bushing suitable to match existing bushing complete, (viii) Removing the burnt out fixed contact assembly from the HT, VCB, 11 KV, 400 Amps of Areva Make supply and fix new contact assembly of copper strip all as specified and directed, (ix) To carryout HV (AC ) Test in open & close condition with suitable HV Kit for both 11 KV VCBs. (x) To check contact resistance (by millivolt drop test or with micro Ohm meter).
Note:- (i) Servicing of VCB to be done only by authorised dealer/ servicing partner of Schnider/Areva/Alstom and CG ( as approved by GE) and proper voucher to be submitted which will be responsibility of the contractor. Strictly no other unauthorised servicing team/people will be allowed to carry out servicing. (ii) Supply only of connected spare items required in VCB repairs shall be measured and paid under ser item No 33.00. However, fixing element of supply only items is deemed included in the quoted rate of ser item No 32.00.
Supply only following spare parts for 11 KV VCB,400 Amps capacity conforming to the respective cat part given as under :-
Trip coil 30 V DC, Cat No CN1339 (Schneider)
Closing coil 30 Volts, DC operated Cat No. CN1347(Schneider)
Buffer closing spring Cat No. MRB39S4020500NA(Schneider)
Buffer opening spring Cat No MRB39S4027200NA(Schneider)
Spring Charging Motor 100 RPM Volts - 230V Ac/dc ICLF Duty: S2 5 min.Type SG-301 Make: Agni, Megna
Relay digital type IRI-PRO-V2-3I-EI-5-5 with In 5A and Freq 50 Hz, Uv 24-270 V AC/24-360VDC and Iw- 6W
S&F in repair of wound type CT Ratio: 50-25/5-5A Core1: CL1, 15VA, Core2: Cl 5p10, 15VA, STR: 13.1KA/1sec, Freq.: 50HZ BIL: 12/28/75kV, Ref. Std. IS 2708, Secondary Terminals on P1 side;complete after removing old existing CT all as specified and directed by Engr-in-Charge. Make: Schneider/Bharti/ECS.
S&F in repair of epoxy upper spouts bushing (L1 phase) of size 40mm dia and 440mm long back side of VCB complete all as specified and directed by Engr-in-Charge.
S&F in repair of epoxy upper spouts bushing (L2 phase) of size 40mm dia and 265mm long back side of VCB complete all as specified and directed by Engr-in-Charge.
S&F in repair of epoxy upper spouts bushing (L3 phase) of size 40mm dia and 225mm long back side of VCB complete all as specified and directed by Engr-in-Charge.
S&F in repair of fire extinguisher B type with CO2 gas of 4 Kg container with mounting stand on wall complete all as specified and directed.
M&L for painting PCC/Steel poles with two coats of synthetic enamel paint supperior quality (approved colour) from top of pole and up to 1.5 mtr height from top of PCC pedstal, for bottom portion of 1.5 mtr height from top of PCC pedstal shall be painted in alternate strips at interval of 30 cm in yellow/black colour including preparation of existing surfaces complete all as specified and directed.
M&L for Calibration of IDMTL relays through primary and secodary injection method and testing complete, re-setting where required and ensuring proper functioning of earth fault and overcurrent relays all as directed.
Supply and fix in repair of Danger notice plate 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 20 X 15 cm size complete all as specified and directed.
Shiv Kripa Tradimg
City Light
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .