Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.5 LAccepted-AOC | L1 | Accepted-AOC L1 Admiited and AOC issued |
Tender Value
₹53.1 L
EMD Value
₹50,000
Closing Date
17 Mar 2023, 5:00 pmClosed
Chief Engineer , KSHB
The Chief Engineer, Kerala State Housing Board, Santhinagar, Thiruvananthapuram P O
HVAC Works for the Development of Government Taluk Hospital Thuravur, Alappzuha District.
2023_KSHB_564787_1
2023_CE_KSHB_11(Ele)
Open Tender
Miscellaneous Services
Item Rate
90 days
Thuravur, Alappzuha District.
Please refer tender documents.
2 documents required · 2 mandatory
₹5,900
₹50,000
17 Oct 2024
8 Mar 2023
20 Mar 2023
8 Mar 2023
17 Mar 2023
8 Mar 2023
8 Mar 2023 - 17 Mar 2023
Amount
AIR CONDITIONING WORKS
od360434/2022_2023 : DX System: Supply installation testing and commissioning of DX(direct expansion) outdoor units with scroll compressors. Air-cooled DX outdoor unit @ 43 Deg C ambient condition with one or two scroll compressors of equal capacity, air-cooled condenser coils, condenser fans with weatherproof motors, safety controls, the microprocessor-controlled starter for evaporator fans, etc. An electrical point will be provided nearest to the unit. All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. Modular type outdoor units equipped with highly efficient scroll compressors, special acryl precoated heat exchanger, and low noise condenser fan. The Refrigerant shall be R - 410 A. The unit shall be supplied with all accessories as required suitable for AHU connectivity. For 2TR units, rotary or reciprocating compressors can be considered if scroll compressors are not available. for 3TR out door units(ICU)
od360442/2022_2023 : DX System: Supply installation testing and commissioning of DX(direct expansion) outdoor units with scroll compressors. Air-cooled DX outdoor unit @ 43 Deg C ambient condition with one or two scroll compressors of equal capacity, air-cooled condenser coils, condenser fans with weatherproof motors, safety controls, the microprocessor-controlled starter for evaporator fans, etc. An electrical point will be provided nearest to the unit. All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. Modular type outdoor units equipped with highly efficient scroll compressors, special acryl precoated heat exchanger, and low noise condenser fan. The Refrigerant shall be R - 410 A. The unit shall be supplied with all accessories as required suitable for AHU connectivity. For 2TR units, rotary or reciprocating compressors can be considered if scroll compressors are not available. for3TR out door units(Sterilisation)
od360443/2022_2023 : DX System: Supply installation testing and commissioning of DX(direct expansion) outdoor units with scroll compressors. Air-cooled DX outdoor unit @ 43 Deg C ambient condition with one or two scroll compressors of equal capacity, air-cooled condenser coils, condenser fans with weatherproof motors, safety controls, the microprocessor-controlled starter for evaporator fans, etc. An electrical point will be provided nearest to the unit. All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. Modular type outdoor units equipped with highly efficient scroll compressors, special acryl precoated heat exchanger, and low noise condenser fan. The Refrigerant shall be R - 410 A. The unit shall be supplied with all accessories as required suitable for AHU connectivity. For 2TR units, rotary or reciprocating compressors can be considered if scroll compressors are not available. for 2TR outdoor units(Sterile store-1W+1S)
od360467/2022_2023 : Ductable split air conditioners (Inverter Type) - Supply installation testing and commissioning of factory-assembled air-cooled ceiling-suspended ductable air conditioners of below-specified capacities. The unit shall be complete with air-cooled outdoor units and ceiling-suspended indoor units with copper refrigerant piping, air-cooled condenser with scroll compressors, thermostatic expansion valves, shut-off valve drier, microprocessor controls, etc. 5.5TR inverter ducted split air conditioners
od360468/2022_2023 : Ductable split air conditioners (Inverter Type) - Supply installation testing and commissioning of factory-assembled air-cooled ceiling-suspended ductable air conditioners of below-specified capacities. The unit shall be complete with air-cooled outdoor units and ceiling-suspended indoor units with copper refrigerant piping, air-cooled condenser with scroll compressors, thermostatic expansion valves, shut-off valve drier, microprocessor controls, etc. 4TR inverter ducted split air conditioners
od360471/2022_2023 : Supply & laying of Refrigerant Copper Piping (Gas line/Liquid line) with 18G HD Copper pipes, insulated with 19mm thickness nitrile rubber tubings and joints and proper supports. The insulation shall have external protection with GC cladding or aluminum foil. All external piping shall run through covered cable trays. Ø1-1/8(28.6mm1.219mm thick)
od360472/2022_2023 : Supply & laying of Refrigerant Copper Piping (Gas line/Liquid line) with 18G HD Copper pipes, insulated with 19mm thickness nitrile rubber tubings and joints and proper supports. The insulation shall have external protection with GC cladding or aluminum foil. All external piping shall run through covered cable trays. Ø7/8(22.2mm1.219mm thick)
od360474/2022_2023 : Supply & laying of Refrigerant Copper Piping (Gas line/Liquid line) with 18G HD Copper pipes, insulated with 19mm thickness nitrile rubber tubings and joints and proper supports. The insulation shall have external protection with GC cladding or aluminum foil. All external piping shall run through covered cable trays. Ø5/8(15.9mm1.219mm thick)
od360477/2022_2023 : Supply & laying of Refrigerant Copper Piping (Gas line/Liquid line) with 18G HD Copper pipes, insulated with 19mm thickness nitrile rubber tubings and joints and proper supports. The insulation shall have external protection with GC cladding or aluminum foil. All external piping shall run through covered cable trays. Ø1/2(12.7mm1.219mm thick)
od360478/2022_2023 : Supply & laying of Refrigerant Copper Piping (Gas line/Liquid line) with 18G HD Copper pipes, insulated with 19mm thickness nitrile rubber tubings and joints and proper supports. The insulation shall have external protection with GC cladding or aluminum foil. All external piping shall run through covered cable trays. Ø3/8(9.5mm0.8mm thick)
od360480/2022_2023 : Supply & laying of Refrigerant Copper Piping (Gas line/Liquid line) with 18G HD Copper pipes, insulated with 19mm thickness nitrile rubber tubings and joints and proper supports. The insulation shall have external protection with GC cladding or aluminum foil. All external piping shall run through covered cable trays.Ø1/4(6.4mm0.8mm thick)
od360481/2022_2023 : Supply, testing, and commissioning of condensate drain UPVC piping as per BIS 4985 with necessary clamps, supports, hangers, and fitting such as bend, tees, reducers, etc. duly insulated with 9 mm thick chemically cross‐linked closed cell nitrile rubber insulation, fire retardant grade as per the drawing and relevant standards.32mm dia
od360482/2022_2023 : Supply, testing, and commissioning of condensate drain UPVC piping as per BIS 4985 with necessary clamps, supports, hangers, and fitting such as bend, tees, reducers, etc. duly insulated with 9 mm thick chemically cross‐linked closed cell nitrile rubber insulation, fire retardant grade as per the drawing and relevant standards.40mm dia
od360483/2022_2023 : Supply, testing, and commissioning of condensate drain UPVC piping as per BIS 4985 with necessary clamps, supports, hangers, and fitting such as bend, tees, reducers, etc. duly insulated with 9 mm thick chemically cross‐linked closed cell nitrile rubber insulation, fire retardant grade as per the drawing and relevant standards.50mm dia
od360484/2022_2023 : Control and power cabling from Isolators for air handling units and DX outdoor units(Power up to isolators by electrical agency) 3cx1.5Sqmm copper cable
od360485/2022_2023 : Control and power cabling from Isolators for air handling units and DX outdoor units(Power up to isolators by electrical agency) 4cx10Sqmmm copper cable
od360486/2022_2023 : Control and power cabling from Isolators for air handling units and DX outdoor units(Power up to isolators by electrical agency) 4cx16sqmm copper cable
od360487/2022_2023 : Supply installation testing and commissioning of earthing for various equipment and motors with necessary supports and accessories 8 SWG copper wire
od360488/2022_2023 : Supply installation testing and commissioning of earthing for various equipment’s and motors with necessary supports and accessories 10 SWG copper wire
Air distribution works
od360439/2022_2023 : Supply and charging of additional refrigerant .R410A
od360450/2022_2023 : Powder coated extruded Aluminium Return air Grilles with horizontal fixed bars and end flanges complete without volume control damper
od360454/2022_2023 : Powder-coated extruded Aluminium Supply air Grilles with horizontal fixed bars and end flanges complete with volume control damper
od360456/2022_2023 : Powder-coated extruded aluminium 4-way removable core type Supply air Diffusers complete with volume control damper 225 X 225 Neck size(standard diffusers)
od360459/2022_2023 : Powder-coated extruded aluminium 4-way removable core type Supply air Diffusers complete with volume control damper 300 X 300 Neck size(standard diffusers)
od360460/2022_2023 : Powder-coated extruded aluminium 4-way removable core type Supply air Diffusers complete with volume control damper 375x375 Neck size(standard diffusers)
od360463/2022_2023 : Powder-coated extruded aluminium 4-way removable core type Supply air Diffusers complete with volume control damper 450x450 Neck size(standard diffusers)
od360465/2022_2023 : Powder-coated extruded aluminum 4-way removable core type return air Diffusers without dampers. 225x225 Neck size(standard diffusers)
od360466/2022_2023 : Powder-coated extruded aluminum 4-way removable core type return air Diffusers without dampers. 300x300 Neck size(standard diffusers)
od360469/2022_2023 : Powder-coated extruded aluminum 4-way removable core type return air Diffusers without dampers. 375x375 Neck size(standard diffusers)
od360470/2022_2023 : Powder-coated extruded aluminum 4-way removable core type return air Diffusers without dampers. 450x450 Neck size(standard diffusers) 450x450 Neck size(standard diffusers)
od360475/2022_2023 : Factory fabricated Low leakage aerofoil type Volume control dampers of 1.2mm thick Aluminium blades, 150mm depth, extended linkage rods for manual operation, channels, flanges suitable for duct mounting and with a manual operating handle. Stiffen damper blades for stability. Include a locking device to hold single-blade dampers in a fixed position without vibration & engraved marking on the position of the damper.
od360476/2022_2023 : Fire dampers for Supply/Return air duct along with fusible link and limit switch for position feedback. The dampers are to be rated for 120 minutes fire rating and the dampers shall be of the spring return type. Fire damper to be provided with TDF matching flanges on both sides with gasket. Fire dampers should be supplied with extended fire-rated extended sleeves.2no.limit switch for 2no NO/NC contactors (One for BMS & one for AHU VFD)
od360479/2022_2023 : Fusible Link and spring mechanism
INSULATION WORKS.
od360426/2022_2023 : Supply, installation and testing of thermal insulation of ducts using closed cell Nitrile Rubber insulation with recommended adhesives and sealed with self adhesive 3mm thick tape and density of material shall be 40‐60 kg/cubm. 19mm thick with aluminium foil or GC cladding.
od360430/2022_2023 : Supply, installation, and testing of thermal insulation of ducts using closed cell Nitrile Rubber insulation with recommended adhesives and sealed with self-adhesive 3mm thick tape and density of material shall be 40‐60 kg/cubm.13mm thick with aluminium foil or GC cladding
od360435/2022_2023 : Supply installation testing and commissioning of Exhaust grills with volume control dampers.150 mm x 150 mm
od360441/2022_2023 : Supply installation testing and commissioning of ceiling-mounted exhaust fans with decorative grills and flexible ducts connection. 50 CFM
od360445/2022_2023 : Supply Erection testing and Commissioning of centrifugal-type inline exhaust fans complete with all accessories including supports/hangers, electrical starters, gravity louvers, canvas connections, etc as per specifications & drawings 300 CFM duct inline fans
od360449/2022_2023 : Supply Erection testing and Commissioning of centrifugal-type inline exhaust fans complete with all accessories including supports/hangers, electrical starters, gravity louvers, canvas connections, etc as per specifications & drawings 200 CFM duct inline fans
od360452/2022_2023 : Supply Erection testing and Commissioning of centrifugal-type inline exhaust fans complete with all accessories including supports/hangers, electrical starters, gravity louvers, canvas connections, etc as per specifications & drawings 150 CFM duct inline fans
od360455/2022_2023 : Supply Erection testing and Commissioning of centrifugal type inline exhaust fans complete with all accessories including supports/hangers, electrical starters, gravity louvers, canvas connections, etc as per specifications & drawings 100 CFM duct inline fans
Additional works:
od360423/2022_2023 : Flexible ductwork of two layer aluminized polyester inner core, surrounded by 25 mm thickness of 24 Kg/M3 density fiberglass, all wrapped in a reinforced multilayer aluminum polyester outer jacket. 150MM DIA
od360429/2022_2023 : Supply and installation of under deck insulation of exposed roof with 50 mm thick-24KG/M3 density expanded poly steryne.
od360431/2022_2023 : Supply installation testing and commission of humidistat ,thermostat ,safety thermostat ,airflow switch and accessors including cabling.
od360437/2022_2023 : Supply, Installation and testing and commissioning of VFD with starter panel for floor mounted and Ceiling mounted Air handling units,.<br>1-Only HVAC application VFD shall be used.<br>2-VFD enclosure to b Included.<br>3-Bypass connection to be included.<br>4-Cabling between VFD Starter panels to unit to be included (5mtr).<br>6-VFD starter panel to be places near unit as per the site condition.<br>7-The panel shall incorporate heater contactors and controlls were ever heaters are specified.
od360440/2022_2023 : Supply installation testing and commissioning of room controllers with temperature, humidity controls.
od360444/2022_2023 : Supply installation testing and commissioning of digital differential pressure monitoring systems for OTS, Isolation room and CSSD.Controller capable of monitoring and displaying multiple rooms with individual sensors.
Bidder Name
BST AIR CONDITIONING & REFRIGERATION PVT LTD
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .