Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC BAGESHWAR UTTARAKHAND UT | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹29.8 L+₹1.4 L (4.86%)Rejected-Finance | L2 | Rejected-Finance Second Lowest bidder | |
| 3 | L3₹30.7 L+₹2.3 L (8.02%)Rejected-Finance | L3 | Rejected-Finance Third Lowest bidder | |
| 4 | L4₹31.6 L+₹3.2 L (11.1%)Rejected-Finance 2685 10 BHAWANI SINGH ROAD DELHI 110007 | NORTH DELHI | DELHI | 110007 | L4 | Rejected-Finance Fourth Lowest bidder | |
| 5 | L5₹33.3 L+₹4.8 L (17.0%)Rejected-Finance | L5 | Rejected-Finance Fifth Lowest bidder |
Tender Value
₹36.1 L
EMD Value
₹80,900
Closing Date
29 Dec 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, RWD DIVISION BAGESHWAR
EE, RWD DIVISION BAGESHWAR
Construction of Physics and Biology laboratories in Government Inter College, Sailani.
2023_RES_66409_1
1671/E-TENDER/RWD/2023-24 DATE 14-12-2023
Open Tender
Civil Works - Buildings
Item Rate
365 days
BAGESHWAR
Please refer tender documents.
1 document required · 1 mandatory
₹3,540
LEKHASHIRSH 0515008000100 and GST 05AAAGR0664Q1ZW
₹80,900
3 Jan 2025
16 Dec 2023
29 Dec 2023
16 Dec 2023
29 Dec 2023
16 Dec 2023
Amount
Earth work in excavation by mechanical means (Hydraulic Excavator / manual means )in foundation trenches or drains (not exceeding 1.5 m in width or 1 including dressing of sides and ramming of bottoms, lift upto 1.5 out the excavated soil and disposal of surplus excavated soil as dir of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade cost of centring and shuttering - -All work upto plinth level 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Reinforced cement concrete work in excluding shuttering, finishing and reinforcement--- 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Substructure
Random rubble masonry with hard stone in foundation and plinth i levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand aggregate 20mm nominal size) at plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centring and shuttering including strutting,ropping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete.
Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Suspended floors, roofs, landings, balconies and access platform.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with F.P.S. bricks of class designation 75 in superstruct level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with F.P.S. bricks of class designation 75 in superstructure plinth level upto floor V level in Cement mortar 1:4 (1 cement :4 coarse sand)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile B Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet,joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer
Providing and fixing M.S. grills of required pattern in frames of windows etc.with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
12 mm cement plaster of mix 1:6 (1 cement : 6 fine sand)
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and stacking of hard stone (for stone pitching) 22.5 cm thick at site.
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 grad finished with a floating coat of neat cement including cement slurry 40mm thick with 20mm nominal size stone aggregate.
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick
25 mm thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed of the slab, including rubbing and polishing complete with base of cementwith grey cement slurry mixed with pigment to match the shade mortar 1 : 4 (1 cement : 4 coarse sand) :
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing ISI marked flush door shutters conforming to I non-decorative type, core of block board construction with frame o wood and well matched commercial 3 ply veneering with vertical g bands and face veneers on both faces of shutters 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Providing and fixing panelled or panelled and gl glazed shutters for doors, windows and clerestory windows i/c ISI marked black emamelled M.S. butt hinges with necessary screws excluding panelling which will be paid separately.30 mm th. shutter Kiln seasoned and chemically treated hollock wood
S/F of glass paneswith putty & nails whereever necessary Float glass panes of thickness 4mmFloat glass panes of thickness 4mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :125mm
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :250x16 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :150X10 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, 100x10 mm
Providing drip course/ groove in plastered surface or moulding to R.C.C. projections.
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all completWith 2nd class teak wood beading 62X19 mm
Providing and fixing white vitreous china laboratory sink with C.I. brackets,C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work 15 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clam cutting and making good the walls etc. Iinternal work - Exposed on 15 mm dia. nominal bore
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (i) Single socketed pipes 75 mm
Providing and fixing ball valve (brass) of approved quality complete High or low pressure with plastic floats 15 mm nominal bore
Providing and placing on terrace polyethylene water storage tank with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and applying white cement based putty of average thickness 1 mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer
Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) Without primer
Lettering with black Japan paint of approved brand and manufacture
Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc.(As per PWD Uttarakhand specifications) Banded wall
Random Rubble Masonary laid dry in breast wall, retaining wall, parapets,scupper etc. Including supply of all materials, labour,t & p& royality etc, required for proper complition of work.(As per PWD Uttarakhand specifications)
H.P stone filling in back of wallls including cost of all materials ,royality.t&p etc. complete..
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix (1:2:4)
CHAUHAN CONSTRACTION
Maa Bharamari Construction
J S D CONSTRUCTIONS
Dinesh Singh Parihar
HIMANSHU NAGARKOTI
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_80115.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .