Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC DOOR NO 38 I H COLONY MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | L1 | Accepted-AOC LOWEST TENDER | |
| 2 | L2₹31.1 L+₹56,976 (1.86%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹32.4 L+₹1.8 L (5.93%)Rejected-Finance NEAR NEELAMMA VEPACHETTU ASSAM GARDENS VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹32.7 L+₹2.1 L (6.83%)Rejected-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹32.9 L+₹2.3 L (7.46%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
27 Apr 2020, 6:00 pmClosed
GE UTILITY II VISAKHAPATNAM
GE UTILITY II 104 Area Industrial Estate Post Visakhapatnam 530007
MANNING AND OPERATION OF FRESH WATER PH, FIRE FIGHTING PUMP HOUSE, DG SETS, SEWAGE PUMP HOUSE AND REPAIR/ MAINTENANCE TO WATER SUPPLY NETWORK SYSTEM INCLUDING DG SETS AT BV YARD AND INS VISWAKARMA UNDER AGE E/M NO.II OF GE(UTILITY-II) VISAKHAPATNAM
2020_MES_337689_1
8688
Open Tender
Electrical Maintenance Service
Item Rate
330 days
GE UTILITY II VISAKHAPATNAM
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE UTILITY II VISAKHAPATNAM
₹90,000
Yes
19 May 2020
7 Apr 2020
28 Apr 2020
7 Apr 2020
27 Apr 2020
21 Apr 2020
Amount
Manning, operation and maintenance of fire pump house along with 200 KVA DG set at INS Viswakarma, NBCD (V) including operating the sewage pumphouse at NBCD (V) round the clock in three shift per day including sundays and holidays at NBCD(V) fire pump house complete all as specified and directed by Engineer-in-charge.
Note:- (i) Man power minimum one skilled and one semi-skilled operator (Total 02 Persons) per shift of 08 hrs. (ii) Rotationally checking/ operationg of fire fighting pump motors, should maintained in separate register as per the format directed by EIC. (iii) In case any power failure 200 KVA DG set shall be operated as early as possible. (iv) Fire hydrants as hydrant wise and fire fighting lines from SWS to BV Yard shall be rotationally checked and checking details should be maintained in register as per the format directed by EIC.(v) To maintain logsheet for fire fighting pumphouse and 200 KVA DG set
List of Plants to be operated are as under:- a) Centrifugal pumpset 100 HP capacity driven by electric motor AC 415 Volts, 3 phase - 02 SetS b) Centrifugal pumpset driven by diesel engine capacity 40 HP - 01 No c) 200 KVA DG set along with accessories complete - 01 No d) Submersible pumpset - 01 No (e) Sewage Pumpsets of 20 HP- 03 Nos
Manning, operation and maintenance of pump houses at SWS including periodical maintenace of pump sets & LT panels, pressure vessel and accessories with minimum one operator per a shift of 08 hrs round the clock including sundays and holidays for the water supply installation at SWS, BV (Y) complete all as specified and directed by Engineer-in-charge. Man Power:-Minimum one skilled operator per shift of 08 hrs in three shift per day. List of Plants to be operated are as under:-
a) Centrifugal pumpset 20 HP capacity driven by electric motor AC 415 Volts, 3 phase - 01 Set b) Centrifugal pumpset 12.5 HP capacity driven by electric motor AC 415 Volts 3 phase - 01 Set c) 20 HP Monoblock pump set- 01 No d) 10 HP Monoblock pump set - 03 No e) chlorine plant - 01 No f) DG Set 75 KVA - 01 No g) 7.5 HP pump sets - 02 Nos
Note for SL item No. 1& 2:- Shift timings Ist shift - 0600 Hrs to 1400 Hrs IInd shift - 1400 Hrs to 2200 Hrs IIIrd shift - 2200 Hrs to 0600 Hrs
Manning, operation and maintenance of valves in INS viswakarma, CTW areas in two shifts per day including Sundays and holiday’s comprising of the following complete all as specified and directed by Engineer-in-charge. Man power: 1 Semi-skilled labour (One Valve man) per shift Shift Timings:- 2 shifts per day timings as under Ist shift: 04.00 to 12.00 IInd shift: 12.00 to 08.00
Notes:- Trouble free sluice /gate valve operating and distribution of regular drinking water to the Vishal block, CTW areas in proper time. (b) Checking Mild steel suction and delivery pipes, UG sumps, valve chambers, maintaining cleanliness of installations etc., (c) Checking the functioning of LT panel including accessories viz starters etc., of Vishal block pump house (d) Adding suitable quantity of chlorination/ bleaching powder to sump water.
Note for SL item No. 1 to 3:- a) Before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of GE duly recomended by Engineer-in- charge.
Supply only stable bleaching powder Gde II confirming to IS:1065 of 1999 second revision available chlorine percentage minimum 32% ± 1% in 25/50 Kgs bags as ordered by Engr-in-Charge. Make:- DCM/Micro/Vikram
Supply only calcium based, high strength chlorination chemical for disinfectant, in granual form for water treatment in factory sealed non returnable HDPE containers (40 to 50 Kg each) having chlorine concentration level of 70% complete all as specified and as directed. Make: Sree Rayalseema solution or its equivalent as approved by GE.
M&L for cleaning of UG sump of 25000 Gallons capacity by pumping out the accumulated water in the bottom and removing the complete silt from the sump and depositing at a distance not exceeding 50 metres and levelling as directed and cleaning with bleaching powder and wire brushing the sump after scrapping the walls and bottoms of the sumps completely without disturbing the inlet and outlet connections including painting the sump and lettering the sump capacity, date of cleaning and due date of cleaning on the sump wall and applying one coat of white wash to entire sump all as per directed.
All as per SL item No.6 above but of 10000 Gallons capacity
All as per SL item No.6 above but of 10000 Gallons capacity steel static water tank Note: Applying Bleaching powder after cleaning the sump is deemed to be included the above quoted rate
Supply and replacement of MS ERW pipe heavy grade pipe 150 mm bore, thickness not less than 5.4 MM laid on suitable size PCC Pillar supports, clamps, bolts and nuts including necessary Tees, elbows, flanges, including cutting etc and preparation of pipe surface and applying two coats of synthetic enamel paint over a coat of zinc chrome primer in open places and with bitumen coating/felt cover for inserting the pipe in position and including making leak proof joints complete all as specified and directed.
All as per SL item No.9 above but 100 mm dia thickness not less than 5.4mm .
All as per SL item No.9 above but 80 mm dia thickness not less than 4.80mm .
M & L for carrying out physical, chemical and biological analysis all as per IS 10500:2012 for drinking water sample of fresh water pump house at various locations from Govt authorised laboratory all as per CPCB Norms complete all as directed by Engineer-in-charge. Note : The rate quoted is deemed to be inclusive of testing and collection of water samples in sealed PVC container from site.
M & L for Jungle cleaning by cutting and clearing away all grass vegetation, wild growth, sapling, shrubs, brushwoods, under growth roots, cutting of bushes, tree trunk of girth not execeeding 30 cm, cutting of trunk, portion protuding over ground, filling holes and leveling of ground and removing unserviceable materials to a distance n.exe 50m, compelte all as speicified
M & L Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint. complete all as specified and as directed.
Supply replace DI K9 water supply pipe lines of size 100 mm bore and including taking down old DI water mains with flanged ends and lead joints including burning out joints and recovering lead complete all as specified and directed by Engineer-in-Charge.
Supply and laying GI pipes medium grade of 25 mm dia with all fittings and fixtures laid in floors / on walls / on roof including taking down old unserviceable complete all as specified and directed.
All as per Sl. item No.16 above but 40 mm dia
All as per Sl. item No.16 above but 50 mm dia
All as per Sl. item No.16 above but 80 mm dia
M&L for rectification of existing defective flanged joints with rubber or fibre gasket complete with necessary nuts, bolts and washers for 80 mm dia GI/DI/MS pipes complete all as directed. Note:- a) quoted rates are inclusive of cutting of GI/DI/MS Pipes, jointing materials and preparation of new flanged sockets and refixing the same at existing place.
All as per SL item No.20 above but of size 100 mm dia.
All as per SL item No.20 above but of size 150 mm dia.
M&L masonary valve chamber of size 1000 x 1000 x 1000 mm (Internal dimensions) and including necessary excavation and earth work in any type of soil, 100 mm thick PCC 1:4:8 type D2 foundation, brick work in cement mortar 1:6, plastering internal and external surface 15 mm thick in CM 1:4, 50 mm thick PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) coping, 50 x 50 x 6 mm thick MS angle iron, 3 mm thick MS plate cover with locking arrangement, painting exposed steel surfaces with two coats synthetic enamel paint over a coat of zinc chrome primer including dismantling old unserviceable one compete all as specified and directed.
All as per SL item No.23 above but of size 900 x 900 x 900 mm (Internal dimensions)
Disconnecting and taking out the existing submersible pump set of 5 HP capacity including all connected cables, suction pipe, etc., from the deep bore well of any depth, carrying out necessary repairs/ servicing/ rewinding and re-erecting the submersible pump set with necessary suction pipe, cables, etc complete including testing all as directed.
Supply and replace CI sluice valves PN 1.6 flanged end (raising type) of size 80 mm bore for complete with iron wheel head and steel spindle including new flanged rubber joint, blts, nuts and washers etc. complete all as specified and directed by Engineer -in-charge.
All as per SL item No.26 hereinbefore but 100 mm dia
Supply & replace 20 mm dia Gun metal gate valve, with iron wheel head, screwed both ends for iron pipe and fixed including cutting the pipe line and taking down old unserviceable valves wherever required complete all as specified and directed by Engr-in-Charge.
All as per SL item No.28 hereinbefore but 25 mm dia
All as per SL item No.28 hereinbefore but 40 mm dia
All as per SL item No.28 hereinbefore but 50 mm dia
Supply only PVPH 41021: Packet of 100 tablets pH RAPID for STEQUA Purity Verifier 41021
Supply only PVFC 41021. Packet of 100 tablets chlorine RAPID for STEQUA Purity Verifier 41021
Supply only DI specials such as bends (any type, radius and angle) tapers any type, straight, bend, increasing, decreasing or double socket etc.) tee pieces single branch, "Y" junction, double branch, cross (all sockets or sockets and spigot) collars, caps and plugs upto 150 mm bore.
Material and labour for repair/ maintenance of control panel board of fire pump house, including renewal of defective unserviceable spare parts i.e. Control wiring, lugs, cable glands, and decarbonising of busbars including changing of burned busbars as required , cleaning panel board, painting the panel board externally with one coat synthetic enamel paint of existing colour code complete all as specified and directed by Engineer-in-Charge.
M&L dismantling Centrifugal/ mono block pump coupled with electric motor 3 phase 415 Volts for overhauling 20 to 25 HP capacity pump sets and including cleaning removing the scales, replacement of case ring, latern ring, shaft sleeve, CI gland covers with MS studs, ball bearings, coupling key, rubber bush, nut, bolts, impeller key, lock washer, gasket, greasing etc, re-assembling same in position, testing and commissioning of complete all as specified and directed by the Engr-in-Charge.
Material and labour for painting of installed Pump sets including connected pipes laid within the pump house area as per the existing colour code with one coat of synthetic enemal paint for Centrifugal pump set of 5 to 12.5 HP capacity including writing letters with paint MES/ SM, serial No and vintage of pump sets with suitable colour complete all as specified and directed by the Engr-in-Charge.
All as per SL. Item No.37 above but pump set of c apacity 20 HP
All as per SL. Item No.37 above but pump set of c apacity 40 HP
All as per SL. Item No.37 above but pump set of c apacity 100 HP
Taking down existing electric motor of 12.5 to 20 HP capacity 3 phase, 415 Volts, 50 cycles AC from foundations bed / coupling, opening the motor, taking to workshop and removing the burnt windings, cleaning the stator and rotor with cleaning agent rewinding the motor with appropriate gauge of super enamelled copper wire of same gauge and same No of turns of existing make insulating winding with existing class of insulation varnishing baking up including replacement of base foundation nuts, bolts and re-installation of motor with suitable packing materials and connecting to the pump, testing the motor to satisfactory performance complete all as directed by Engineer-in-charge. Note: Bearings are deemed to be inclusive of above quoted rate.
All as per SL item No.41 above but 5 to 10 HP capacity.
M&L dismantling Centrifugal/ mono block pump coupled with electric motor 3 phase 415 Volts for overhauling 20 HP capacity pump sets, including cleaning removing the scales, replacement of case ring, latern ring, shaft sleeve, CI gland covers with MS studs, ball bearings, coupling keys, rubber bush, nut, bolts, impeller key, lock washer, gasket, greasing etc, re-assembling the same in position, testing and commissioning complete all as specified and directed by the Engr-in-Charge. Note: Bearings are deemed to be inclusive of above quoted rate.
All as per SL item No.43 above but 12.5 HP capacity.
All as per SL item No.43 above but 0.50 to 10 HP capacity.
Supply and replace 80 mm dia CI foot valve complete all as specified and directed.
All as per SL. Item No.46 above but 50 mm dia foot valve
Repair/ servicing of dial type water level indicator by replacing wornout central movement plate, counter weight, centre diving wheels etc., and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
Supply and replace 3 pole power contactor with coil voltage 415 Volts AC , 50 Hz suitable for the existing motor of capacity upto 10 HP complete all as directed.
Supply and replace 3 pole power contactor with coil voltage 415 Volts AC , 50 Hz suitable for the existing motor of 12.5 to 20 HP capacity complete all as directed.
Dismantling of radiator complete from DG Sets of 200 KVA capcity cleaning/scraping manualy from outside of the radiator, cleaning of all copper tubes of radiator with descaling solution from inside & outside with forged feed method with water and aircompressor (by using separate chemical cleaning water pump & compressor) plugging of all leakage in welding, brazing of copper tubes, cleaning of fins and replacement of gaskets etc., fcomplete all as specified and as directed.
All as per Sl. Item No.51 above but 125 KVA capacity
All as per Sl. Item No.51 above but 75 KVA capacity
M&L for preparation of old painted surfaces of DG Set of 200 KVA capacity by scraping / brushing and cleaning with cloth and applying one coat of synthetic enamel paint by spray machine of existing colour code complete and lettering the SM and MES Number on the DG Set complete all as directed.
All as per Sl. Item No.54 above but 125 KVA capacity
All as per Sl. Item No.54 above but 75 KVA capacity
Taking out Diesel Tank of any capacity carefully including disconnecting from system, descaling the diesel tank with water pressure and removing the complete deposited waste, drying the tank and painting the tank with two coats of super enamelled paint out side the tank size, replacement of gate valve and fixing the tank in its original location and connecting with existing diesel line, replacing of GI/MS fittiing, diesel indicator of glass/PVC tube with necessary fitting, repair to any leakage, cleaning and testing of fuel line upto FIP inlet, including locking arrangements complete upto 600 Ltrs capacity all as directed.
M & L for Replacement of complete water hose pipe set including clips, nuts, bolts and washers etc., of the DG Set of 75 to 200 KVA capacity complete all as specified and directed by Engr-in-Charge.
M & L for rewinding of self starter coil, upto 24 Volts, with existing size copper wire including varnishing and replacement of bush bearing, carbon bush, clutch plate set, pinion ete., complete all as specified and directed by Engr-in-Charge.
M & L for rewinding of Dynamo upto 24 Volts with existing size copper wire including varnishing & replacement of bush etc., complete all as specified and directed by Engr-in-Charge
Supply and filling Engine oil 15 W 40 Grade Castrol CRB for topping up (including draining out old oil from Gen Set) complete all as specified and directed. Make : Castrol.
Toping up of water coolents for radiator assembly
Cleaining, over hauling and removing the sump cover of DG set of 200 KVA capacity, cleaning the sump, removing sludge, dust etc., including replacement of sump gasket and re-fixing the sump cover complete all as directed. Note:- Toping up Engine oil shall be measured and paid separately.
All as per SL. Item No.63 above but for 125 KVA DG Set
All as per SL. Item No.63 above but for 75 KVA DG Set
Supply and replace complete fuel and oil hose pipe set (except water hose pipe and radiator) with clip of 75 to 200 KVA DG Set complete all as directed.
Supply and replace battery charger of capacity 24 Volts electronic type with auto cut system complete including charger base stand complete all as specified and as directed.
Supply and replace electronic control board of 62.5 KVA to 500 KVA DG Set with all necessary required nuts and bolts complete all as directed.
Supply and replace oil/air filters of DG sets of any capacity complete all as specified and directed.
Excavation in trenches n.exc. 1.5 m wide and n. exc. 1.5 m in depth and getting out in soft / loose soil for foundation, of pipe lines etc, complete all as specified and directed by Engr-in-Charge.
All as per SL item No.70 above but in hard/dense soil
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in soil.
Removing surplus excavated soil n. exc. 50 m and depositing where directed at a level n-exc 1.5 m above the starting point.
GS ENGINEERS
Bhuvaneswari Electrical Works
GVR CONSTRUCTIONS
M/S SRI VENKATA BHAVANI CONSTRUCTIONS
M/s NATIONAL ENGINEERING CONSTRUCTIONS CO
Sri Surya Enterprises
AYYAPPA CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .