Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LAccepted-AOC WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC LOWEST AND REASONABLE RATE | |
| 2 | L2₹51.0 L+₹1.2 L (2.37%)Rejected-Finance | L2 | Rejected-Finance HIGHER RATE |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
11 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY
BHUJ
COMPREHENSIVE MAINTENANCE FOR AGE BR II OF GE ARMY BHUJ AT MIL STN BHUJ
2024_MES_653523_1
8211
Open Tender
Civil Works
Item Rate
270 days
GE ARMY BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE ARMY BHUJ
₹98,000
Yes
13 Jul 2024
11 May 2024
13 Jun 2024
11 May 2024
11 Jun 2024
24 May 2024
Amount
Attending complaints related to Plumbing/Water Supply and obtaining completion from user including minor repair of taps by replacement of washers, tightening of taps, tightening of check nuts of PVC connection and making water supply functional Note : Replacement of minor items like Sockets, Unions, Elbow,Tee, Clamps,Teflon tapes, Solutions,M Seal etc simliar items are included in this rate Other major items listed in this BOQ will be paid separately as S & F in repair complete all as specified and directed.
S&F in repair ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe 20mm bore (Minimum weight 210 gms) complete all as specified and directed.
S&F in repair Bib taps CP fancy type with butterfly handle screwed down high pressure for 15mm bore ISI marked complete all as specified and directed.
S&F in repair Bib tap standard of PTMT any colour high pressure screwed for iron pipe 15mm bore (Minimum weight 90 gms) complete all as specified and directed.
S&F in repair Pillar taps cast copper alloy quarter turn, fancy type CP screwed down high pressure for 15mm bore complete all as specified and directed.
S&F in repair Stop valve of PTMT any colour high pressure screwed for iron pipe 15mm bore (Minimum weight 90gms) complete all as specified and directed.
S&F in repair stop valve of PTMT any colour high pressure screwed for iron pipe 20mm bore (Minimum weight 112gms) complete all as specified and directed.
S&F in repairstop/angle valve cast copper alloy screwed down high pressure with crutch or butterfly handle for pipe of 20mm bore complete all as specified and directed.
S&F in repair waste coupling of PTMT (half or full threaded) for discharge pipe of 32mm bore (Minimum weight 45gms) complete all as specified and directed.
S&F in repair PVC waste pipe for 32mm bore pipe complete complete all as specified and directed.
S&F in repairGrating doom 100 mm dia of PTMT (Minimum weight 25 gms) complete all as specified and directed.
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in repair PVC low level flushing cistern kit complete all as specified and directed.
S&F in repair PVC valve-less, syphonic action type, flushing cistern, low level, 10 litre capacity (ISI marked) white with inlet, ball valve,float and handle including brackets complete all as specified and directed.
S&F in repair PVC lids for water storage tank of cap 500 Litres complete all as specified and directed.
S&F in repair PVC lids for water storage tank of cap 1000 Litres complete all as specified and directed.
S&F in repair Rotational moulded polyethylene water storage tanks ISI Mark 1000 Litres Capacity ( Cylindrical vertical with closed top hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed.
S&F in repair 16mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings concealed or open incl replacing of unserviceable pipe (up to 1 m) like elbow, socket, nipple, union socket, tee etc with the existing size complete including making necessary threading work to be carried out upto any height or on walls for 16mm bore of pipe complete all as specified and directed.
S&F in repairto 16mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings concealed or open incl replacing of unserviceable pipe (Above 1m but less than 2m) like elbow, socket, nipple, union socket, tee etc with the existing size complete including making necessary threading work to be carried out upto any height or on walls for 16mm bore of pipe complete all as specified and directed.
S&F in repair to 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings concealed or open incl replacing of unserviceable pipe (up to 1 m) like elbow, socket, nipple, union socket, tee etc with the existing size complete including making necessary threading work to be carried out upto any height or on walls for 20mm bore of pipe complete all as specified and directed.
S&F in repair to 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings concealed or open incl replacing of unserviceable pipe (Above 1m but less than 2m) like elbow, socket, nipple, union socket, tee etc with the existing size complete including making necessary threading work to be carried out upto any height or on walls for 20mm bore of pipe complete all as specified and directed.
S&F in repair to 25mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings concealed or open incl replacing of unserviceable pipe (up to 1m) like elbow, socket, nipple, union socket, tee etc with the existing size complete including making necessary threading work to be carried out upto any height or on walls for 25mm bore of pipe complete all as specified and directed.
S&F in repair to 25mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings concealed or open incl replacing of unserviceable pipe (Above 1m but less than 2m) like elbow, socket, nipple, union socket, tee etc with the existing size complete including making necessary threading work to be carried out upto any height or on walls for 25mm bore of pipe complete all as specified and directed.
Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 16 mm dia, any grade, of any description or in any position including fittingscomplete all as specified and directed.
Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 20mm dia, any grade, of any description or in any position including fittings complete all as specified and directed.
Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 25mm dia, any grade, of any description or in any position including fittings complete all as specified and directed.
S&F in repair 16mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorscomplete all as specified and directed.
S&F in repair 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
S&F in repair 25mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
S&F in repair vitreous china Wash down water closet (pedestal pattern), complete including Pedestal pan and trap and seat cover, including connection to drain ( or outgoing pipe) and flushing pipe, antisyphonage pipes etc (excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F in repairs vitreous china water closet (squatting pan), orissa patern size 580 x 440mm white with integral, foot rests an including 'P' trap and lime bedding making good to floors complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
S/F Non skid coloured plain/printed glazed tiles of size 300 x 300 x 6mm to 7 mm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 20 mm thick rendering in CM 1:4 complete all as specified and directed.
S&F in repair vitreous china wash basin, white flat back , size 550mmx450mm with and including Waste fittings, brass, chromium plated for basins with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed with and including Supplying and fixing cast copper alloy chromium plated fancy type pillar tap 15mm bore, screwed down high pressure with or without lettered hot or cold with long shanks, screwed for iron pipecomplete all as specified and directed.
S&F in repair vitreous china wash basin, white flat back , size 450mmx300mm with and including Waste fittings, brass, chromium plated for basins with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed with and including Supplying and fixing cast copper alloy chromium plated, fancy type, pillar tap, 15mm bore, screwed down high pressure with or without lettered hot or cold with long shanks, screwed for iron pipe complete all as specified and directed.
S&F in repair for Swivel shower rose size 125 mm of PTMT , any colour , for fixing with 15 mm dia pipe ,( minimum weight 40 gm. ) with and including Shower arm 15 mm size, 195 mm long with bend of 45 degree with flange of PTMT any colour (Min wt. 40gms) , fixed in repairs , complete all as specified and directed.
S&F in repair 15mm dia 2-in-1 bib tap with angle valves, Chromium plated crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipes or for unions. (conforming to JAINKO Cat no. BCJ-4 or its equivalen make)complete all as specified and directed.
S&F in repair health faucet spray type jet with brass jet, chromium plated, and 1.5m long PVC flexible pipe complete all as specified and directed.complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) pipes Type B ISI marked single socketed in any length with rubber ring joints laid on wallcomplete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR) pipes Type B ISI marked single socketed in any length with rubber ring joints laid on wall fixed complete all as specified and directed.
S&F in repair PVC (SWR) bends, 110 mm bore, any radius complete all as specified and directed.
S&F in repair PVC (SWR) bends, 75 mm bore, any radiuscomplete all as specified and directed.
S&F in repair PVC (SWR) Junction, single, (single T) equal or unequal, 110 mm bore, with access door complete all as specified and directed.
S&F in repair for PVC (SWR) vent cowl, 110 mm bore complete all as specified and directed.
S&F in repair PVC (SWR) 75mm branch piece, single (single Y) equal or unequal with access door complete all as specified and directed.
S/F in repair 75 mm bore PVC (SWR) floor trap plain with grating incl jointing with solvent cement complete all as specified and directed.
Attending complaints related to Carpenter Work and obtaining completion from user including repair of easing of doors re-fixing or retightening of doors, windows, resecuring of door/window wire guage etc including nails, screws etc required to make good the work Note : Replacement of minor items like Beadings, Runners,Screws,Nails,etc simliar items are included in this rate Other major items listed in this BOQ will be paid separately as S & F in repair complete all as specified and directed.
S&F in repairchromium plated brass Towel Rail 60cm long including brackets, complete all as specified and directed.
S&F in repair 300mm mild steel helical door spring rat tail type including collar plate and welding if required or otherwise fixed with screw on wooden frames complete all as specified and directed.
S & F in repair Stainless steel 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples in window/Door frames complete all as specified and directed.
S & F in repair Aluminium, anodised, barrel tower bolts of extruded section 150mm size complete all as specified and directed.
S & F in repair Aluminium, anodised, barrel tower bolts of extruded section 200mm size complete all as specified and directed.
S & F in repair Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy 250mm size complete all as specified and directed.
S & F in repair Aluminium handles, cast type, anodised 150mm size complete all as specified and directed.
S & F in repair Aluminium handles, cast type, anodised 100mm size complete all as specified and directed.
S & F in repair Hasp and staple 100mm size, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
S & F in repair floor door stopper 150mm size of brass body and tongue, anodised, with hard drawn steel spring complete all as specified and directed.
S & F in repair Stainless steel curtain rods 25mm dia fancy type with required supports, and open/end brackets complete all as specified and directed.
S&F in repair perforated particle boards or tiles 12mm thick for insulation and acoustic purposes, 60cm x 60cm in size complete all as specified and directed.
S & F in repair sheet glass ordinary quality 4mm thick and glazing with oil putty in squares not exceeding 0.50 Sqm complete all as specified and directed.
S & F in repair figured glass, pinhead type ordinary quality 4mm thick and glazing with oil putty in squares not exceeding 0.50 Sqm complete all as specified and directed.
S & F in repair Aluminium Door closer hydraulically regulated, designation No. 3, universal type complete all as specified and directed.
Attending complaints related to black smith work and obtaining completion from user including repair of steel frames of doors and windows, CGI roof sheets, steel rolling shutter by drilling/ welding, resecuring of door/ window etc complete all as specified and directed.
Attending complaints related to Aluminium work and obtaining completion from user including repair of Aluminium doors and windows,Note : Replacement of minor items like joining cleats, glazing clips, ruber neoprene packing, handles ,hinges, anodised aluminum snap beading screws ,etc simliar items are included in this rate Other major items listed in this BOQ will be paid separately as S & F in repair complete all as specified and directed.
Attending complaints related to mason work such as repair to existing damaged plaster/ floor/ plinth protection/ jointing of damage brick/stone work in minor patches not exc 1.0 Sqm each including matching the surface with existing finish with necessary material like , cement, sand, lime aggregate, brick stone etc are included in this rate complete all as specified and directed.
Attending complaints related to mason work such as repair to existing damaged plaster/ floor/ plinth protection/ jointing of damage brick/stone work in minor patches not exc 2.0 Sqm each including matching the surface with existing finish with necessary material like tiles , cement, sand, lime aggregate, brick stone etc are included in this rate complete all as specified and directed.
Attending complaints related to mason work such as repair to existing damaged plaster/ floor/ plinth protection/ jointing of damage brick/stone work in minor patches not exc 3.0 Sqm each including matching the surface with existing finish with necessary material like tiles , cement, sand, lime aggregate, brick stone etc are included in this rate complete all as specified and directed.
Taking down carefully existing unserviceable aluminum/copper point wiring (light, fan, socket or power) of any description & in any position complete including all fittings & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc including taking out and removing serviceable fittings/fixtures and making good the disturbed surface of walls, floors, ceiling etc. to match with the existing surfaces complete all as specified and directed.
M&L for point wiring with using 1.5 Sqmm (nominal area) with multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade , ISI -694 marked with valid CML No in and including medium grade, PVC concealed conduit in stone masonry in wall of any thickness of dia not less than 20 mm and conduit accessories, ISI marked with valid CML no (IS-9537-19 for conduit and IS :3419:19765 for conduit accessories )concealed in wall with mild steel/ pressed steel modular sunken box (with earth dolly) of 1.6mm thick of suitable size, duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer externally covered with modular cover and plate for fixing of modular switch,socket etc including PVC insulated multi stranded copper conductor to commom earth and connecting to earth dolly complete all as specfied and directed for the following:- NOTE :- 1. The complete wiring installation shall be carried out in accordance and conformity with IS 732:1989 "code of practise for electrical wiring(latest version). 2. The unit rate aganist item of PVC concealed conduit point wiring includes for MS pressed steel sunken box for modular wiring GI sunken box duly painted with two coats of anti corrosive paint/black bituminous paint externally and two coated of aluminium paint over a coat of red oxideprimer internally for fixing switches,regulator, socket outlet etc with modular plate & box ISIS marked. 3.All screws,fasteners ,bolts,nuts & washer etc shall be of cadmium plated, The cost of which deemed to be included in the unit rate. 4.The complete wiring installtions shall be tested on completion as specfied in particular specfications. 5.The cutting/leaving , forming chases shall be done with electric cutter and not by chiselling. 6.Cutting chases in stone masonry wherever shall be deemed to be included in unit rate. 7.The completed wiring Quoted rate shall be deemed to include the making good the disturbed surface for concealed with CM 1:4 cement motor including finishing the surface to match with the existing surface. 8. Fittings like modular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'.
One light/buzzer point controlled by one; one way switch complete all as specified and directed.
One fan/exhaust fan point controlled by one, one way switch complete all as specified and directed.
One 3 pin socket out let 5 amp (independent) point controlled by one; one way switch complete all as specified and directed.
One 3 pin socket out let 5 amp point on the (same board) with other switches complete all as specified and directed.
All as per item No. 70 here-in-before but with 2.5sq mm size FRLS single core pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor and 2.5sqmm PVC insulated and unsheathed cable 1100 volts grade with multistrand copper conductor as earth wire for 3 pin socket outlet 15 amp on independent board complete all as specified and directed.
M&L for point wiring with using 1.5 Sqmm (nominal area) with multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade , ISI -694 marked with valid CML No in and including medium grade, PVC concealed conduit in cement brick masonry and in wall of any thickness of dia not less than 20 mm and conduit accessories, ISI marked with valid CML no (IS-9537-19 for conduit and IS :3419:19765 for conduit accessories )concealed in wall with mild steel/ pressed steel modular sunken box (with earth dolly) of 1.6mm thick of suitable size, duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer externally covered with modular cover and plate for fixing of modular switch,socket etc including PVC insulated multi stranded copper conductor to commom earth and connecting to earth dolly complete all as specfied and directed for the following:- NOTE :- 1. The complete wiring installation shall be carried out in accordance and conformity with IS 732:1989 "code of practise for electrical wiring(latest version). 2. The unit rate aganist item of PVC concealed conduit point wiring includes for MS pressed steel sunken box for modular wiring GI sunken box duly painted with two coats of anti corrosive paint/black bituminous paint externally and two coated of aluminium paint over a coat of red oxideprimer internally for fixing switches,regulator, socket outlet etc with modular plate & box ISIS marked. 3.All screws,fasteners ,bolts,nuts & washer etc shall be of cadmium plated, The cost of which deemed to be included in the unit rate. 4.The complete wiring installtions shall be tested on completion as specfied in particular specfications. 5.The cutting/leaving , forming chases shall be done with electric cutter and not by chiselling. 6.Cutting chases in brick/cement masonry wherever shall be deemed to be included in unit rate. 7.The completed wiring Quoted rate shall be deemed to include the making good the disturbed surface for concealed with CM 1:4 cement motor including finishing the surface to match with the existing surface. 8. Fittings like modular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'.
One light/buzzer point controlled by one; one way switch complete all as specified and directed.
One fan/exhaust fan point controlled by one, one way switch complete all as specified and directed.
One 3 pin socket out let 5 amp (independent) point controlled by one; one way switch complete all as specified and directed.
One 3 pin socket out let 5 amp point on the (same board) with other switches complete all as specified and directed.
All as per item No. 71 here-in-before but with 2.5sq mm size FRLS single core pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor and 2.5sqmm PVC insulated and unsheathed cable 1100 volts grade with multistrand copper conductor as earth wire for 3 pin socket outlet 15 amp on independent board complete all as specified and directed.
M&L for point wiring with using 1.5 Sqmm (nominal area) with multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade , ISI -694 marked with valid CML No in and including medium grade, PVC casing caping and it connected accessories, ISI marked with valid CML with modular sunken box externally covered with modular cover and plate for fixing of modular switch,socket etc including PVC insulated multi stranded copper conductor to commom earth and connecting to earth dolly complete all as specfied and directed for the following:- NOTE :- 1. The complete wiring installation shall be carried out in accordance and conformity with IS 732:1989 "code of practise for electrical wiring(latest version). 2. The unit rate aganist item of PVC concealed conduit point wiring includes for MS pressed steel sunken box for modular wiring GI sunken box duly painted with two coats of anti corrosive paint/black bituminous paint externally and two coated of aluminium paint over a coat of red oxideprimer internally for fixing switches,regulator, socket outlet etc with modular plate & box ISI marked. 3.All screws,fasteners ,bolts,nuts & washer etc shall be of cadmium plated, The cost of which deemed to be included in the unit rate. 4.The complete wiring installtions shall be tested on completion as specfied in particular specfications. 5.The cutting/leaving , forming chases shall be done with electric cutter and not by chiselling. 6.Including removing old unservicable wiring and finishing the surface to match with the existing surface. 7. Fittings like modular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'.
One light/buzzer point controlled by one; one way switch complete all as specified and directed.
One fan/exhaust fan point controlled by one, one way switch complete all as specified and directed.
One 3 pin socket out let 5 amp (independent) point controlled by one; one way switch complete all as specified and directed.
One 3 pin socket out let 5 amp point on the (same board) with other switches complete all as specified and directed.
All as per item No. 72 here-in-before but with 2.5sq mm size FRLS single core pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor and 2.5sqmm PVC insulated and unsheathed cable 1100 volts grade with multistrand copper conductor as earth wire for 3 pin socket outlet 15 amp on independent board. (only one point per circuit)
Supply and fix in repair ceiling rose surface bakelite , three terminals, 230V AC with polycarbonate body complete all as specified and directed.
Supply and fix in repair modular switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix in repair modular switch 16 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix in repair modular bell switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix in repair modular socket, 6 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix in repair switch socket modular , 6 /16 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix in repair modular fan regulator 120 W 2 module complete all as specified and directed.
Supply in repairs earth plug and socket, single pole, neutral sheet metal enclosures with a two pin, plug and socket 20Amp, 240 volts with and including one MCB, SP, 20A, 240 Volts as per all as specified and directed.
Supply and fix in multi music ding dong AC 230 Volt single pole complete all as specified and directed.
Supply and fix in repair lamp holder PVC / Polycarbonate type suitable for LED lamp fitting including LED 9watt bulb complete all as specified and directed.
Supply and fix in repair LED 20 W high quality indoor batten type tube light fitting with PC housing and as well light application CCT 6000 K, electrical connection of three core 0.5 sqmm copper flexible connection from ceiling rose to tube light fitting and with proper square box for fitting of tube light fitting complete all as specified and directed.
Supply and fix in repair LED 10 W high quality indoor batten type tube light fitting with PC housing and as well light application CCT 6000 K, electrical connection of three core 0.5 sqmm copper flexible connection from ceiling rose to tube light fitting and with proper square box for fitting of tube light fitting complete all as specified and directed.
Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & F sheet metal enclosure powder painted for MCB DB SPN 08 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed.
Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & F sheet metal enclosure powder painted for MCB DB SPN 04 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed.
Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & F sheet metal enclosure powder painted for vertical type MCB DB TPN 04 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed.
Taking down carefully MCBs, metal clad plug, distribution boards/main switches of any type and size and Supplying and fixing sheet metal enclosure powder painted for MCB DB vertical type TPN 4 way double door with dinrail and busbar with IP-43 protection with door earthing and isolated neutral bar and insulated busbar assembly including MCCB of 100 Amps complete all as specified and directed.
Supply & Fix in repair MCB TPN, 63 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
Supply & Fix in repair MCB SPN, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
S&F in repair MCB single pole, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed
Taking Down Old Unserviceable Submain wiring complete including all accessories and making good the disturbed surfaces all as specified and as directed.
M/L for Sub main wiring with 2 runs of PVC insulated unsheathed multi stranded single core copper conducter 6 Sqmm drawn through PVC concealed conduit in stone masonry/brick masonry including accessaries with 6sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting up complete all as specified and directed. Note: 2 runs of cable and one run earth wire and concealed PVC conduit will be measured as one length.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ complete all as specified and directed.
M&L for repair/replacement to internal wiring fittings and fixtures such as light fittings, sockets, switches and bell etc in any type and capacity & in any position including replacing unserviceable item or replacing whole fixture, fittings in internal electrification , fault finding in wiring complete all as specified and directed. Note 1 :The items should be paid separately under item No.96 to 117 and 125 to 127 Note 2: Labour charges for replacing items No.96 to 117and 125 to 127 shall be demmed to be included in this item.
Supply only LED 20 W high quality indoor batten type tube light fitting with PC housing and as well light application CCT 6000 K, electrical connection of three core 0.5 sqmm copper flexible connection from ceiling rose to tube light fitting and with proper square box for fitting of tube light fitting complete all as specified and directed.
Supply only LED 10 W high quality indoor batten type tube light fitting with PC housing and as well light application CCT 6000 K, electrical connection of three core 0.5 sqmm copper flexible connection from ceiling rose to tube light fitting and with proper square box for fitting of tube light fitting complete all as specified and directed.
Supply only fan regulator electronic, step type, socket non modular suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified and directed.
Supply only lamp holder PVC / Polycarbonate type suitable for LED lamp fitting complete with LED bulb 9W all as specified and directed.
Supply only Bell push, flush type 5 AMP AC 230 Volt single pole complete all as specified and directed.
Supply only socket outlet five pin, 5 Amps, flush type, 230 volts AC circuit, as per model at site complete all as specified and directed.
Supply only switch socket outlet combination, multipurpose, three pin, 15 Amps & three pin 5 Amps controlled by one switch , flush type, 230 volts AC circuit as per model at site complete and 4 holes on corner all as specified and directed.
Supply only switch flush type, 5/6 Amps, single pole, one way, 230 volts AC circuit complete all as specified and directed.
Supply only switch socket outlet combination, multipurpose, three pin, 5/6 Amps & three pin 5 Amps controlled by one switch , flush type, 230 volts AC circuit complete and 4 holes on corner complete all as specified and directed.
Supply only multimusic buzzer , ding dong AC 230 Volt single pole complete all as specified and directed.
Supply and laying Rigid non-metallic PVC conduit but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc of size 25mm dia including drawing cable, wire through PVC conduit complete all as specified and directed.
Supply and laying Rigid non-metallic PVC flexiable protected corrugated conduit of size 20mm for loose wire near DB including drawing wire through conduit complete all as specified and directed.
Supply and laying in repiar of PVC casing and caping but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc of size 25mm dia including drawing cable, wire through PVC casing capping complete all as specified and directed.
supply only 9W LED bulb all as specified and directed.
Supply only ceiling rose surface bakelite , three terminals, 230V AC with polycarbonate body complete all as specified and directed.
Supply only modular switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed.
Supply only modular switch 16 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed.
Supply only modular bell switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed.
Supply only modular socket, 6 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed.
Supply only switch socket modular , 6 /16 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed.
Supply only modular fan regulator 120 W 2 module complete all as specified and directed.
supply only 15A Top suitable for exisiting board complete all as specified and directed.
supply and fix in repair plastic Modular surface mounted switch board of 1 module including modular front , back plate and plastic suken box all as specified and directed.
All as per above Item No.118 but of 2 module complete all as specified and directed.
All as per above Item No.118 but of 3 module complete all as specified and directed.
All as per above Item No.118 but of 4 module complete all as specified and directed.
All as per above Item No.118 but of 6 module complete all as specified and directed.
All as per above Item No.118 but of 8 module complete all as specified and directed.
All as per above Item No.118 but of 10 module complete all as specified and directed.
Supply only MCB TPN, 63 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
Supply only MCB SPN, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
S&F only MCB single pole, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and fix in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc complete all as specified and directed.
Notes- Applicable for Items from No.01 to No.68:-
(a) Establishment of complaint cell:- (i) Complaints cells will be established at AGE B/R -II Office (As per locations given by Engineer-in Charge/GE). The numbers of complaints cells in the ibid contract will be One only. (ii) Contractors will deploy manpower/tradesman with requisite tool & plant for smooth functioning of complaint cell under subject work. The details per complaint cell is as given below :- (aa) Data Entry Operator - 01 complaint cell. (ab) Supervisor - As required for management of all the complaint cell under subject tender in consultation with GE/Engr-in charge. (ad) Tradesmen & Helpers - As required for management of all the complaint cell under subject tender in consultation with GE/Engr-in-Charge and will be present in all complaints cells. The numbers of the tradesman shall be adequate to address all the complaints on daily basis. (ae) The Data Entry Operators and Supervisors will be deployed from 9AM to 5 PM on all complaint cell to manage the complaints cell.
(a) Establishment of complaint cell (Contd):- (iii) The contractor will provide compatible computer system, printers, peripheral, consumables, internet connection/Dongle for each complaint cell alongwith requisite furniture for functioning of complaint cell and storage of store as required. (iv) (A)The complaints in the cell will be received through complaint register / site orders book / Verbally / Telephonically / Mobile or any other mode/system as evolved and intimated by JE/Engr-in-Charge. (B) One of the system of complaint receiving is by generating QR CODE at each block /buindings comes under AOR of AGE B/R - II and Cost required for developement of QR CODE will be included by contractor in this item no extra payment will be provided during execution by the departement all as directed by Engr-in-Charge. The contractor shall take immediate action to register and attend all the complaints. (v) The complaints will be addressed through complaint slips and contractors will prepare abstract of all the complaints received and action taken thereof on daily basis and will submit to JE/Engr-in-Charge.
(vi) Dress Code:- (aa) Deployed manpower/tradesmen to attend and resolve the complaint shall wear proper uniform. Dress code for plumber, carpenter, scavenger and Electrician etc. shall be approved by Engr-in-Charge with monogram/badges which shall be fixed on the dress. (ab) The number of workers shall be increased based upon number of complaints and quantum of work involved during working hours as decided by JE/Engr-in-Charge.
(viii) T&P :- (aa) The contractor is responsible to provide all T& P to all the manpower deployed, items such as Drill Machines, cutters, welding machines, scaffoldings etc as and when required at site. (ab) Any other misc works/services connected with user facilitation as per direction of Engr-in-Charge. (ac) The responsibility of taking the tradesmen to complaint site will be of contractor. (ix) Sign Boards :- For each complaint cell, adequate flex sign board of approved size will be placed in complaint cell by contractor. The content of the flex board will be approved by Engr-in-Charge/GE.
(x) All Taking Down for fixing new items will be included in the rates
(b) Penalty Clause Contractors will pay penalty on account of non addressal of complaints in given time frame as per matrix given below. The penalty will be levied by Engr-in-Charge/GE after ascertaining the time taken to address the complaints and justifiable delay, if any. The penalty matrix for each complain is as given below :- PENALTY Time delay For Plumber : Less than 24 hrs Nil 24 hrs to 48 hrs Rs. 25 48 hrs to 72 hrs Rs. 50 72 hrs and more Rs. 75 For Carpenter : Less than 48 hrs Nil 48 hrs to 72 hrs Rs. 25 72 hrs and more Rs. 75 For Mason : Less than 72 hrs Nil 72 hrs to 96 hrs Rs. 25 96 hrs and more Rs. 75
(c) Management of urgent nature of complaints such as leakage, water over flow, sewage, Airlock leakage on holiday and after 5 PM till 9 AM everyday will also be the responsibility of contractor. For the same adequate tradesman and helper of lack type etc will be made available in each complaint cell by the contractor. (d) All above aspects shall deemed to have been included in the quoted price by the contractor. (e) Recovery on non wearing of uniform :- The employee and labourers engaged by the contractor under this contract shall wear neat and clean uniforms as approved by Engineer-in-Charge along with name badges, else recovery shall be made @ Rs 50/- per person per day. (f) The quoted rates shall be deemed to be included of all provisions mentioned above. The decision of accepting officer in this regard shall be final and binding and without prejudice to all. No claim/representation shall be entertained in the subject matter.
(h) The adequet no of workers as required per day to address the day to day maintenance works shall be deployed by contractor.
Notes- Applicable for Items from No.69 to No.130:-
(1) The contractor shall keep all items readily available at site, which is required for urgent repair works.
(2) In case of absence of manpower without providing suitable replacement, an amount of Rs 1000/- per day shall be recovered as liquidated damage per person per day from the bill.
(3) Common miscellaneous material such as screws any type, nails, washers, insulation tapes, clamps, hooks, which are required for the work the cost of which is deemed to be included in quoted rate.
(4) All tools &tackles, plants, machineries, equipment and material to carry out the work at site which is to be decided by GE (A) Bhuj shall have to be provided by the contractor at his/ her own cost.
(5) Contractor’s supervisor (electrical engineer) should be available at the site to supervise the works and co-ordinate with the officials.
(6) The electrician on duty round the clock will have to be available at the site service centre created by the contractor & should have mobile phone. In case of absence of electrician, Rs 500/- will be levied as penalty for each instance.
(7) The manpower shall be issued identity card after getting due verification. Uniform should be worn by the manpower having monogram of the firm.
(8) The skilled worker should be facilited with mobile phone to contact on urgent tasks & their numbers should be displayed at various places and forwarded to administration.
(9) The contractor shall ensure safety of his workers and other at site of work and shall be responsible for any consequence arising out of execution of the repair and maintenance works.
(10) The contractor shall ensure that his repair/ maintenance staff is qualified and licensed for their part of work. He shall be responsible for their conduct. The contractor shall be held responsible for any loss or damage to employees’ state insurance corporates property.
(11) The date of repair, unit name & serial number shall be mentioned in neat sticker in the appliances after repair.
(12) Contractor is to collect the faulty appliances from units & return them after repair within a week. No separate charges shall be given for transportation.
(13) It is responsibility of contractor to clean the area after repair work of appliances. Rates are deemed to be include in his quoted rates of respective items.
(14) The same nature of complaints in same location/block shall be counted as one complaint in internal electrification. Job card and complaint register for entry of complaints shall be provided at his/ her own cost.
(15) The contractor provide test certificate of material to be incorporated in the work.
(16) Any of contractor persons causes damage of equipment or property of Military station, the contactor will be solely held responsible for the cost of consequences thereof.
(17) Contractor shall carry out all test. The equipments shall conform to Indian standards. 1) IR test. 2) Polarity test. 3) Earth Resistance test etc. The test report after completion testing shall be submitted to the department with duly signed by licensed electrican following current leakage/any fault in wiring. The report shall be given with proper format showing each circuit value of test done. Equipment to be used in testing should be calibrated, date of calibration to be displayed on the equipment and calibration report should be submitted.
(18) Contractor shall identify the real cause of fault of wiring . wiring problems that are identified should be documented.
(19) Work diary & hindrance register shall be maintained by the site engineer of the contractor. The shall be deposited to department daily with duly signed by contractor.
(20) Job card /Docket shall be maintaned properly mentioning as below: a) service Number b) Name c) Rank d) unit e) Date Format of docket/job card shall be provided to contractor. Date of receiving & Date of resolving with time shall be endosrsed on job card.
(21) Joint measurement weekly. The contarctor should be availble for joint measurement along with supervisor on every Wednesday/as decided by Enginner-in-charge.
(22) Stationery such as complaint register, Job card/Docket , work diary ,hindrance register, site order register etc shall be supplied by the contractor
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
sudarshan builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .