EMD Value
₹4,950
Closing Date
28 Jan 2026, 10:00 amClosed
Sr. Executive Engineer, ES Division Jassure
Sr. Executive Engineer, ES Division Jassure
Tender for repair and overhauling of 132kV SF6 Circuit Breaker ABB make installed at 132kV Substation Kangra under ES Division HPSEBL Jassure.
2026_HPSEB_126211_1
ESDJ-24/2025-26
Open Tender
Miscellaneous Services
Percentage
60 days
132kV Sub-Station Kangra
Please refer Tender documents.
5 documents required · 5 mandatory
₹590
₹4,950
6 Mar 2026
19 Jan 2026
28 Jan 2026
19 Jan 2026
28 Jan 2026
19 Jan 2026
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority: Sr. Executive Engineer, Electrical System Division, HPSEBL, Jassure.
Name of Work: Tender for repair and overhauling of 132kV SF-6 Circuit Breaker ABB make installed at 132/33/11kV Substation Kangra under ES Division HPSEBL Jassure.
Contract No: ESDJ-24/2025-26
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT With Taxes in Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
1 Repair & servicing of 132KV, SF6 circuit breaker at 132KV substation at Kangra of ABB Make, the detail of following works needs to be carried out during the repair & servicing of 132KV sf6 circuit breaker: The replacement of burnt auxiliary switch unit, OH Kit for Pneumatic Drive (pole drive mechanism) complete breaker, SF6 Gas interpole pipe for A-B pole & B-C pole along with density monitor gauge, checking of contact resistance for closing/tripping coil 220VDC, replacement of damaged variable resistor 50 ohm for tripping/closing coil, replacement of 3-phase power contactor a/w thermal overload relay, refilling of SF6 gas then checking of gas leakage with gas leakage detector after overhauling, testing of breaker pole contact with CRM (Contact Resistance Measurement) & timer along with test reports, replacement of 01 nos. burnt auxiliary contactor with 4NO+4NC, local/remote selector switch etc. Complete job in all respect as per the direction and satisfaction of Engineer-in charge. BI01010001010000000000000515BI0100001113 1 Job Excess(+) Full Conversion INR 0 INR Four Lakh Ninety Three Thousand Eight Hundred & Thirty Only 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
Total in Figures INR Four Lakh Ninety Three Thousand Eight Hundred & Thirty Only 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.10 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
TERMSANDCONDITIONS.pdf
Tender Documents • 0.21 MB
BOQ_186047.xls
BOQ • 0.27 MB
SBDCriteria.pdf
Additional Documents • 0.13 MB
add.pdf
Additional Documents • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .