Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.5 L+₹63,895.80 (4.02%)Rejected-Finance PLOT NO D 2 COAL DEPOT FOSBERY ROAD SEWRI E MUMBAI 400 015 | MUMBAI | MUMBAI | MAHARASHTRA | 400015 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹16.6 L+₹68,095 (4.28%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
22 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BARODA
GE AF BARODA PO MAKARPURA BARODA 390014
REPAIR AND MAINT OF HT/LT NETWORK AND OTHER ASSOCIATED WORKS AT MAKARPURA UNDER GE (AF) BARODA
2020_MES_346914_1
8565/E8
Open Tender
Electrical Maintenance Service
Item Rate
270 days
GE AF BARODA
AS PER NIT AND TENDER DOCUMENTS
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹38,000
Yes
20 Aug 2020
22 May 2020
25 Jun 2020
22 May 2020
22 Jun 2020
9 Jun 2020
26 May 2020 - 30 May 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5m deep and getting out in hard/dense soil for laying of cable etc complete all as specified and directed.
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each layer complete all as specified and directed.
Removing excavated material to a distance not exc. 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed.
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of class HV, type I, size 300mm x 180mm x 40mm, factory made, complete all as specified and directed.
M & L PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) for coping of the pole including necessary form work complete all as specified and directed.
M & L PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) for foundation of the pole complete all as specified and directed.
Dismantling & taking out unserviceable steel and iron items from poles i.e cross arms, bracing, supports, clamps and back plates etc. including nuts & bolts complete all as specified and directed.
Fixing only the serviceable MS cross arms, FI clamps etc with and including acessories such as bolt, nuts and washers etc as obtained from item No 8.00 here in before on electrical pole at any location with and including painting of steel surfaces with two coats of aluminium paint over a coat of red oxide primer after preparation of old surfaces complete all as specified and directed.
Supply & fixing cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts & bolts , washers , welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
M&L for stay assembly for HT poles comprising of 20mm dia, 2.15 mtr long galvanized stay rod, having 7/3.15mm GI stay wire stranded and 300mm X 500mm X 6mm thick MS stay plate, complete all as shown on electrical plate No 1 of SSR, Part-I with and including all necessary fittings/accessories like loop type insulator, shackle & stay clamps, necessary excavation and earth work in any type of soil and PCC works in (1:3:6) type C2 (using 40mm graded stone aggregate) including taking down old unserviceable stay assembly complete all as specified and directed.
Supply and fixing pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, 150mm height and 150mm dia suitable for working pressure upto and including 11000 volts grade including taking down existing old unservicable inslulator complete all as specified and directed.
Supply and Fixing disc type insulator, porcelain, vitreous 145 mm height and 225 mm dia ball and socket type white/brown or green two in series assembly for tension with tension clamps for conductors working pressure 11000 volts grade including taking down existing old unservicable inslulator complete all as specified and directed.
Material & labour for supply and fixing of aluminium conductor steel reinforced (ACSR) of any size/description on HT poles/lines including stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc including connecting, commissioning and testing including dismantling & taking down of existing worn out / unserviceable aluminium conductor steel reinforced (ACSR) complete all as specified and directed.
M&L for servicing and maintenance of gang operated switch and drop out fuse assembly, triple pole by applying white petrolium jelly, greasing the operating mechanisam & drop out fuse assembly (set of three) complete servicing of male contact (fixed jaw contacts) post insulators, copper / aluminium jumpers arcing horn operating GI Class B Pipe 20/25 mm dia, pipe guide locking arrangement, operating lever, Ht fuse element including nut bolt washerss etc and making the GOD functional all the way smooth operation for contact and disconnection complete all as specified and directed. Note: (a) Rate quoted by the tenderer is deemed to include for the cost of replacement of minor parts like nuts, bolts, jumper wire, petrolium jelly etc. (b) GOD opertation if not found smooth from ground after servicing, contractor must repair/service the same on no cost basis for entire period of contract.
Dismantling and taking down existing unserviceable GOD switch and Supply, fixing, commissioning and testing of outdoor type, new gang operated switch, single throw single break off load type, of current rating upto 200 Amps, nine pole, each pole consisting of galvanized steel base, HT insulators as per IS, non ferrous knife and spring, loaded contacts, arcing horns of adequate section to break magnetizing current of the transformers, horizontal GI pipe of adequate length for phase separation, adequate length of GI pipes for operation from ground level and operating handle with locking arrangement complete in both OFF & ON positions. All ferrous parts hot dipped galvanized and non ferrous heavily tinned to withstand weather and suitable for vertical mounting with fuse unit carrier of 200 Amps rating and fuse element upto 50 Amps along with rod for expulsion fuses and 3 Nos post insulators for fuses complete all as specified and as directed.
Dismantling existing poles /struts of any type, any size and supply, erecting and fixing in true vertical position, new steel tubular swaged pole (410 SP – 55), 11 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole finished with two coats of aluminum paint over one coat of red oxide primer complete all as specified and directed (Near. MRS makarpura) Note :- Earth work, PCC in foundation and coping, shall be measured and paid seprately.
Dismantling and taking down existing unserviceable lightening arrestor of any capacity and any description and Supply, fixing, commissioning & testing of distribution class new lightening arrestor of rating 11 KV capacity and 10 KA NDC(Peak) confirming to to IEC-99.4 including brackets, clamps, bolts, nuts and washers complete all as specified and directed.
Supply, laying, jointing and testing 11 KV (Earthed), aluminum conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cables conforming to IS 7098 (Part-II) amended upto date having cross sectional area 95 Sqmm 3 core including taking down existing old unservicable cable of any type complete all as specified and directed
Supply , jointing and testing cable jointing kit of 11 KV grade cable for outdoor termination, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sq mm.including taking down old unserviceable joint kit complete all as specified and directed.
Supply, jointing and testing cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured cable of size 50 sqmm to 95 sqmm including taking down old unserviceable joint kit complete all as specified and directed.
Supply, jointing and testing cable jointing kit for 11 KV(Earthed) grade cable for straight through heat shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured cable of size 50 sqmm to 95 sqmm including taking down old unserviceable joint kit complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping of poles using necessary form work including demolition of existing broken coping complete all as specified and directed.
Trimming branches of trees, bushes, herbs upto 10 Mtr surrounding of 4 pole/ 2 pole structure including removal of cut down tree branches etc to a distance not exceeding 50 mtr from over head line all as specified and directed
Supply and fix Danger notice plate for HT of size 25cmx20cm and 1.6 mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal RED colour and fixed with MS clamps bolts and nuts of appropriate size including taking down old danger notice plate complete all as specified and directed.
S & F in repairs Chain link MS galvanised fencing of 3mm dia of wire each way and 50mm mesh size of weight not less than 2.22 Kg per Sqm and fixed to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
S&F in repairs framed work as in door or gate of angle or other section with gusset plates, rail, braces etc complete drilled for fixing of steel sheeting or other covering. Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting also fastening and fixing, steel sections confirming to Fe-410-W complete all as specified and directed.
M&L for cutting chases in hard standing/ road / path/ drain making holes in concrete wall etc for passing through of cable and making good surfaces as existing by using PCC (1:3:6) type C-2 using 40 mm graded stone aggregate complete all as specified and directed.
Dismantling of existing unserviceable anti-climbing device and S&F new anti-climbing device fabricated out of 50x6 mm FI, 15 cm long MS bar of 8mm dia, 12 mm dia / flat iron spikes made out to shape complete all as specified and directed .
Dismantling / disconnecting unserviceable switch air break and M&L for new switch air break TP mechanically operated mounted on insulator and steel frame operating mechanism for current rating 200 Amps, 11000 volts complete all specified and directed.
Supply and fix cable route indicator made out of 150 mm round disc of cast iron duly written with HT/11 KV cable properly fixed with nut bolts to angle iron 40X40X5 mm of length 60 cms properly grouted in ground to a depth 25 cms with PCC 1:2:4 type B1 using 20 mm graded stone aggregate of size 10X10X10 cm under ground. The Angle iron shall be painted with two coats of synthetic enamelled paint over a coat of red oxide primer including taking down old unserviceable indicators complete all as specified and directed. (excavation, returning filling and removal are included in the quoted rate)
M&l servicing and maintenance of HT VCB 11000 Volt 400 Amp of any make and type at existing site including opening /drawing out the VCB trolly after switching off electric supply testing and maintenance of VCB panel complete with following:- (i) Checking of all mechanical/electrical control systems for proper functioning including spring charging system, tripping system, indication system, vaccum interrupter; cleaning & servicing the fixed/moving contacts & blowing out dust and applying the proper lubrication/greasing complete, (ii) checking of Contact Resistance (RYB) and Auxiliary Supply voltage of closing coil, tripping coil, Motor; cleaning & servicing for proper functioning (iii) Timing Test of closing time and opening time, IR value with 5 KV megger before and after HV, (iv) Checking of PT & CT which shall include ratio test and healthiness of the HT and LT fuses and associate circuiting. (v) Breaker testing which inclueds (a)Insulation resistance, (b)Pick up and drop of operating coils, (c) To check IR Values(CT) (d) To carryout polarity test(CT), (e) to check Knee point voltage/ measurement in case of class PS CT (vi) Servicing of HT, 11 KV, VCB, 400 Amps capacity, 50 Hz, breaking capacity 50 KA by drawing out from moving contacts for smooth funcitoning including replacement of tripping and closing coils, 30 volts, DC and servicing of solenoid switch, all as directed, (vii)Dismantling of unserviceable bus bar bushing from existing 11 KV bus bar chamber and supply and fix bushing suitable to match existing bushing complete, (viii) Removing the burnt out fixed contact assembly from the HT, VCB, 11 KV, 400 Amps of Areva Make supply and fix contact assembly of copper strip all as specified and directed, (ix) To carryout HV (AC ) Test in open & close condition with suitable HV Kit for both 11 KV VCBs. (x) To check contact resistance (by millivolt drop test or with micro Ohm meter) complete all as specified and directed. (Note: Servicing of VCB to be done only by authorised dealer/ servicing partner of Schnider/Areva/Alstom and CG ( as approved by GE) and proper voucher to be submitted which will be responsibility of the contractor. Strictly no other unauthorised servicing team/people will be allowed to carry out servicing).
Note:- Supply only of connected spare items required in VCB repairs shall be measured and paid under ser item No 33.00. However, fixing element of supply only items is deemed included in the quoted rate of ser item No 32.00.
Supply only following spare parts for 11 KV VCB,400 Amps capacity of Make: Crompton Greaves, conforming to the respective cat part given as under :-
Vacuum interrupter type WL-33379
Fixed contact block 400 amps. Cat part No. 522
Auxiliary switch (6 NO + 6 NC ). Cat part No. 562
Closing coil 30 V DC
Tripping coil 30 V dc
Heating element with thermo stat switch
Buffer closing Spring
Buffer opening Spring
Support Insulater 11 Kv
Relay Digital type IRI-PRO-V2-31-EI-5-5 with 5A and frequency 50 Hz ,uv 24-270 V AC- 360 V DC and lw-6W
M&L for Calibration of IDMTL relays through primary and secondary injection method and testing complete, re-setting where required and ensuring proper functioning of earth fault and overcurrent relays complete all as specified and directed
S&F in repairs Tripping shaft suitable for HT VCB 11000 Volts of existing make with springs & Truip strips of standard manufacturers complete all as specified and directed. (of make used by original manufacturer of VCB)
S&F in repairs closing shaft suitable for HT VCB 11000 Volts of existing make with springs & close strips of standard manufacturers complete all as specified and directed. (of make used by original manufacturer of VCB)
S&F in repairs Trip catch suitable for HT VCB 11000 Volts of existing make with all linkages of standard manufacturers complete all as specified and directed. (of make used by original manufacturer of VCB)
S&F in repairs Warm Gear (small)/Half teeth gear suitable for HT VCB 11000 Volts of existing make of standard manufacturers complete all as specified and directed. (of make used by original manufacturer of VCB)
S&F in repairs Power Pack 110 V AC three phase and out put 30 volt DC as per sample, suitable for HT VCB 11000 Volts of existing make of standard manufacturers and as per sample kept in the office of GE complete all as specified and directed
S&F in repairs wound type 11 KV RESIN CAST CT, CTR : 100-50/5-5A, Core1 : CL 1, 15 VA, at 50/5 A CL 1, 15 VA, at 100/5 A, Core2 : CL 5P10, 15 VA, at 50/5 A CL 5P10, 15 VA, at 100/5 A, STR : 13.1KA/1 SEC, Frequency: 50 Hz BIL : 12/ 28/ 75 KV, Insulation Class: B, Ref Std.: IS 2705, Secondary Terminals on P1/P2 Side including taking down old existing CT, complete all as specified and directed and as per sample kept in the office of GE. Make: Bharti/ECS/Schneider.
Material and labour for cleaning and preparation of all existing 4 pole structure steel surfaces of steel tubuler poles 11 mtr long including channels mild steel cross arms, clamps etc complete and applying one one coat of aluminium paint all round the exposed steel surfaces of existing steel tubuler poles of any description and in any position above the height of 1.50 mtr from the plinth of the pole and applying one coat of synyhetic enamelled paint of different colours in strips of 150 mm width up to the height 1.5 mtr from the plinth of pole including writing pole No and other sign works with white paint over black painted base in the pattern and style as approved by the Engineer in charge complete all as specifeied and directed . Note : Size of black painted base for numbering shall be 100 mm x 25 mm and the size of numbers shall be not erxceeding 10 cm height.
Description all as per serial item no 41 here in before but 2 pole structure .
Supply and Fix in repairs insulating mat 3 mm thick of size 1mtr x 2 mtr complete all as specified and directed.
Dismantling and taking out old PVC flooring of any description and M&L for supplying and fixing nominal 2 mm ( + 10% tolerance) thick electric insulated P.V.C. synthetic sheet flooring viz conforming to IS-15652 of 2006 alongwith suitable adhesive/chemibound, having leakage current tested to meet requirement of IS-8437, IS-3043, break-down strength 40 KV having no adverse impact of mineral oil, high insulation resistance including material for water proofing of floor and sealing of all joints as required, suitable for floor covering around electrical apparatus for voltage not exceeding 3.3 KV (AC) to ground complete all as specified and directed by the Engineer-in-Charge
Disconnecting indoor/outdoor type 11/0.433 KV transformer of capacity 63 KVA to 400 KVA from HT/LT sides and taking out transformer oil completely and storing the oil in suitable container ( to be provided by the contractor) removing the conservator tank assembly and cooling fins for cleaning and removing accumulated sludge, clogging materials etc from conservator tank with use of air blast, re-assembling of conservator tank and cooling fins in its original position with replacement of rubber cork sheet with new one of existing shape and size, refilling the transformer oil after cleaning and connecting all the connections of HT & LT sides complete all as specified and directed
Note:- Supply only of connected spare items required in transformer repairs shall be measured and paid under ser item No 48.00 to 54.00 . However, fixing element of supply only items is deemed included in the quoted rate of ser item No 45.00.
Filteration/dehydration of transformer oil through filtration plant to improve the dielectric strength/insulation value of the transformer oil upto 40 KV (RMS) at 4mm gap complete all as specified and directed for various capacity of transformers/OCB’s installed at various locations
Supply and filling in replacement/topping up of transformer insulating oil EHV grade having dielectric strength not less than 40 KV (R.M.S) at 4mm gap high viscosity in transformer confirming to IS – 335 of 1983 all as specified and directed for various capacity of transformers installed at various locations
Supply only silica gel in breathers of various capacity of transformers including taking out old unserviceable silica gel complete all as specified and directed.
Supply only rubberized cork sheet gasket of 6 mm thickness cut to size/shape for top cover of transformer upto 400 KVA capacity complete all as specified and directed by Engineer-in-Charge.
Supply only LT side porcelain bushing for 100 to 400 KVA capacity transformer complete all as specified and directed by Engineer-in-Charge.
Supply only HT side (11KV) porcelain bushing for 100 to 400 KVA capacity transformer complete all as specified and directed by Engineer-in-Charge.
Supply only LT side copper set stem with nut bolts and washers complete for 100 to 400 KVA capacity transformer complete all as specified and directed by Engineer-in-Charge.
Supply only HT side brass set stem with nut bolts and washers complete for 100 to 400 KVA capacity transformer complete all as specified and directed by Engineer-in-Charge.
Supply only HV / LV copper Coil 100 to 160 and 250 to 315 KVA(per Phase)
Dismantling of old unserviceable breather assembly of any description/capacity and supply & fixing new breather assembly transparent body suitable for 11/0.433 KV transformers of capacity 100 KVA to 500 KVA complete all as specified and directed by Engineer-in-charge.
Replacement of existing unserviceable temperature gauge old type with new temperature gauge of existing specification/Model for transformers of capacity upto 750 KVA complete all as specified and directed.
Supply and fixing in replacement and testing externally operated tap changer switch “OFF LOAD TYPE” on HV winding to vary the LV Voltage up to + 7.5% variation limit in steps of 2.5% complete suitable for upto 500 KVA transformers complete all as specified and directed by Engineer-in-Charge.
M & L for hiring of Fault Locator Machine Vehicle, complete, from the authorised supplier alongwith their dedicated specialised team; finding out the exact HT fault location from both end terminations of underground cable; submission of report of fault for verification and records of Engineer in charge; M&L for necessary excavation and earthwork, returning filling in, removal of surplus spoil, sand cushioning, cable covers, complete and M&L for straight through cable jointing kit ( 11KV, heat shrink type with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm); complete all as specified and direcred.
Transportation of transformer carefully, any capacity(100 - 500 KVA), including lifting, loading and unloading, from site of work/ power house to workshop and back after completion of work in workshop, complete with all safety measures all as directed. Note: (i) The transportation shall be to any distance within municipality limits of Baroda. (ii) Rates of Hydra for lifting transformer at both the places (Site and workshop) both time pre and post repair is deemed to be included in quoted rates.
.M & L for cleaning & preparation of transformer surfaces of any description, and capacity 100 KVA to 400 KVA, in any position and painting of transformers out side with applying two coats of synthetic enamel grey paint after removing all dust/rust including writing the SM No/MES No on transformers with white paint in the existing style/pattern complete all as specified & directed.
M&L servicing and maintenance of Ring Main Unit Out door type 11000 Volt of any make and type at existing site including opening RMU after switching off electric supply testing and maintenance of panel complete with following:- (i) Checking of all mechanical/electrical control systems for proper functioning including spring charging system, tripping system, indication system, cleaning & servicing the fixed/moving contacts & blowing out dust and applying the proper lubrication/greasing complete, (ii) checking of Contact Resistance (RYB) servicing for proper functioning supply and fix bushing suitable to match existing bushing complete, Note: (a) Servicing of RMU to be done only by authorised dealer/ servicing partner of Schnider/Areva/Alstom and CG ( as approved by GE) and proper voucher to be submitted which will be responsibility of the contractor. Strictly no other unauthorised servicing team/people will be allowed to carry out servicing. (b) The parts/items/accessories if any fixed in repairs for minor adjustment, the cost of such repairs is deemed to be included in the unit rate quoted by the contractor.
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanized iron earth strip 32x6 mm as earthing lead by means of bolt ,nuts, check nuts and washer of galvanized iron or steel besides welding of all joints as shown in drawing and including excavation and earthwork, G.I.pipe light grade 40mm bore for protection of G.I.strip from earth electrode to the earth test point, supplying and laying charcoal dust, common salt, PCC 1:3:6 type CI chamber and MS angle iron frame 40x40x3mm, RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm c/c both ways with MS handle 12 mm dia CI funnel and wire mesh, 20 mm dia GI pipe light graded for watering all as shown in electrical plate no.3 and connected to earth test point incl testing complete all as specified and directed .
K A ELECTRIC CO
MAA SHAKTI ENGG. CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .