Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹39.0 LAccepted-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | 1 | Accepted-AOC AOC | |
| 2 | 2₹44.0 L+₹4.1 L (10.4%)Rejected-Finance | 2 | Rejected-Finance NOT L-1 | |
| 3 | 3₹44.1 L+₹4.2 L (10.5%)Rejected-Finance | 3 | Rejected-Finance NOT L-1 | |
| 4 | 4₹45.5 L+₹5.6 L (14.1%)Rejected-Finance 2 A NARENDRA APPARTMENT CENTRAL JAIL ROAD SUBHASH BRIDGE AHMEDABAD 380027 | AHMEDABAD | AHMEDABAD | GUJARAT | 380027 | 4 | Rejected-Finance NOT L-1 | |
| 5 | 5₹45.7 L+₹5.8 L (14.6%)Rejected-Finance | 5 | Rejected-Finance NOT L-1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY BHUJ
GE ARMY BHUJ
REPARES/REPLACEMENT OF CERTAIN EM WORKS AT BHUJ AND SIYOT AREA UNDER GE(A) BHUJ.
2023_MES_580586_1
8988
Open Tender
Civil Works
Item Rate
180 days
ARMY AREA BHUJ
REFER TENDER
6 documents required · 6 mandatory
₹500
GE ARMY BHUJ
₹90,000
Yes
26 Mar 2023
13 Feb 2023
6 Mar 2023
13 Feb 2023
4 Mar 2023
27 Feb 2023
Amount
Disconnecting, taking out, removing old existing unserviceable LT underground cable any size and type etc complete all as specified and directed.
Supplying ,Laying , jointing and testing XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade of size 4 core 10 Sqmm laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed.
- ditto- here in before Item 2 but of size 4 core 16 Sqmm
- ditto- here in before Item 2 but of size 4 core 25 Sqmm
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft loose soil.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils.
M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed. Note: Punned thickness shall only be measured and paid
Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables.
S & F in replacement GI pipe, light grade, of size 40 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection .
S&F in replacement Sheet metal enclouser 2 way with din rail complete all as specified and directed by Enfr-in-Charge.
S&F in replacement Sheet metal enclouser 4 way with din rail complete all as specified and directed by Enfr-in-Charge.
Supply and fixing in replacement of wall surface mounting light fitting in new generation energy saving environemental friendly LED up and down luminaire wall surface light fitting decorative type of capacity 15 watt , IP 66 including all acessories complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of wall surface mounting light fitting in new generation energy saving environemental friendly compact lihght weight LED spike light fitting decorative type of capacity 5 watt , IP 66 including all acessories complete all as specified and directed by Engineer-in-charge. Make:- Philips /Havells / Wipro
Supply and fixing in replacement of gate light light fitting in new generation energy saving environemental friendly LED solar pillar light with built in solar panel , LED lihght and lithium battery with charger controller of capacity 5 Watt , 5700 K , IP 66 including all acessories complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of bollard light fitting in new generation energy saving environemental friendly LED solar bollard light with built in solar panel , LED lihght and lithium battery with charger controller of capacity 5 Watt , 5700 K , IP 66 including all acessories complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of post top lantern LED type of capacity 25 Watt 230 Volts AC outdoor type environmental friendly , long life aesthetically designed with symmetrical light distribution , IP 65 protection with all fixing accessories complete all as specified and directed by Engineer-in-charge. Make:- Philips /Havells / Wipro
Supply and fixing in replacement of LED Bolard new generation ,energy saving, environmental friendly , long life aesthetically designed aluminum landscape for diffused lighting with high power LEDs ,IP65 protection and impact of capacity 10 Watt complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of fountain light new generation ,energy saving, environmental friendly , long life LED under water fountain light of capacity 10 Watt complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement new generation ip 67 rated flexible LED strip to add great color & dramatic effects with extensive pallet colour including external driver of capacity 36 Watt complete all as specified and directed by Engineer-in-charge.Make:- Philips /Havells / Wipro
M&L for three core PVC insulated sheathed(heavy duty) unarmoured aluminium conductor cable of size 1.50 Sqmm for connection drawing through pole , conduit for light fittings complete all as directed.
Dismantling and taking out old U/S street light Panel , Supply and fixing street light panel Confirm to IS/IEC 60947-4-1 , in built Short circuit protection , Class H insul;ation , IP 54 , 3 Phase , with digital timer , contactor rating 40 Amps , MCB rating 40 Amps TPN , max load 6 KW complete with all fixing acessories including civil workas specified and directed.
Dismantling and taking out old U/S street light Panel , Supply and fixing street light panel Confirm to IS/IEC 60947-4-1 , in built Short circuit protection , Class H insul;ation , IP 54 , 3 Phase , with digital timer , contactor rating 65 Amps , MCB rating 63 Amps TPN , max load 12 KW complete with all fixing acessories including civil workas specified and directed .
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fitting and fixture and such as as switches, sockets ceiling rose,pendent holders,regulators,light fittings any type removing materials to store in safe custody or for credite etc, and making good the disturbed surface of walls and floors etc as directed.
M&L for point wiring with two single core PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm 1100 volts grade in and including PVC casing capping of size 20 to 25 mm with all accessories and one single core PVC insulated unsheathed solid copper cable of size 1.5 Sqmm 1100 Volts grade as earth continuity conductor connected to common earth dolly, switch board complete with PVC rectangular type box heavy duty for mounting the switch socket etc complete as specified for the following :- (a) One light/Fan point controlled by one 5 Amps switch one way complete
- ditto-- but One bell point controlled by one 5 Amp bell push complete
--dotto-- but one 5 Amp socket point controlled by one 5 Amp switch independent board with cable 2.5 sqmm.
–ditto- but on the same board.
All as per item No.02 here-in-before but with two single core PVC insulated unsheathed copper conductor cable of size 2.5 Sqmm 1100 volts grade and one single core PVC insulated unsheathed solid copper conductor cable of size 2.5 Sqmm 1100 Volts grade as earth continuity conductor for 3 pin 15 Amps socket point on independent board complete all as specified and as directed.
S&F switch piano flush type 6 Amp. AC, 240 Volts one way all as directed.
S&F switch piano flush type 15 Amp. AC, 240 Volts one way all as directed.
S&F bell push flush type single pole one way, 5 Amp, AC,230 V all as directed with frame cover
S&F switch socket combination. Multi purpose 6 Pin 6 Amp flush type AC, 230V complete all as directed.
S&F switch socket combination. Multi purpose 6 Pin 16 Amp flush type , AC, 230V complete all as directed.Make :- Anchor / Havells/ Legrand
S&F ceiling Rose, surface, bakelite 65 x50 mm three terminals, AC, 230 Volts complete all as directed.Make :- Anchor / Havells/ Legrand
S&F angle holder backelite with insulated body AC, 230V complete all as directed.Make :- Anchor / Havells/ Legrand
S&F bell electric AC, 230V, Single phase, Dingdong type complete all as directed.
S&F step type electronices fan regulator flush type, 100 watt, AC, 230V, Single phase, complete all as directed.
S&F modular type electronices fan regulator, 100 watt, AC, 230V, Single phase, complete all as directed.
S&F Modular switch 1 way 6A 1 module type all as directed.
S&F Modular switch 1 way 16A 1 module type all as directed.
S&F Modular Socket 6A/16A - 2/3 pin combined 2 module all as directed.
S&F Modular Switch socket Combination 16A, 6 pin, 3 module all as directed
S&F in repair square recessed / surface/suspended mounting LED slim ceiling light with extruded aluminium housing and milky diffuser of 36 W 2'X 2' slim panel LED driver 240 V ,50 Hz complete all as specified & approved by EIC. M
S&F in repair decorative box type fitting with LED tube 18 to 20 watt for 230 volt AC complete including making all connection using 1.5 sqmm copper conductor muilstranded PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through in PVC flexible conduit all as specified & approved by EIC.
M&L for Sleek LED mirror light 10 watt rating with diffuser 2ft long twisted flexible copper wire complete all as specified & approved by EIC. Make :- Havells/Philips/ GE
M&L in repair for submain wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable of size 6 Sqmm 1100 volts grade and one run of PVC insulated unsheathed solid copper conductor cable of size 6 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic PVC concealed / surface conduit of suitable size on roof/wall/ceiling including making good the disturbed surfaces of wall etc including taking out old unserviceable burnt/damaged sub main wiring from its existing position complete all as directed by Engr-in-Charge (Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate).
M&L in repair for submain wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable of size 4 Sqmm 1100 volts grade and one run of PVC insulated unsheathed solid copper conductor cable of size 4 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic PVC concealed / surface conduit of suitable size on roof/wall/ceiling including making good the disturbed surfaces of wall etc including taking out old unserviceable burnt/damaged sub main wiring from its existing position complete all as directed by Engr-in-Charge (Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate).
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flexible two core cable flat or circular of size 6 Sqmm solid aluminium conductor all as specifiied and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flexible two core cable flat or circular of size 10 Sqmm solid aluminium conductor all as specifiied and directed.
Taking down old unserviceable main switches/DB’s up to 100 Amps capacity fixed in wall and making good of all disturbed surfaces as per existing .
S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 4 way, AC,240 volt with 200 Amp bus bar rating complete all as directed. Make :- Havells / Legrand / GE / Seimens
S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 8 way, AC,240 volt with 200 amp bus bar rating complete all as directed.
S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 12 way, AC,240 volt with 200 Amp bus bar rating complete all as directed.
S&F sheet metal enclosure double door (MCB DB) three phase and neutral with 200 Amps rated bus bar TPN, 4 way horizontal type, with provision of MCB incommer, AC, 415 Volt complete all as specified & directed.
S&F sheet metal enclosure double door (MCCB DB) three phase and neutral with 200 Amps rated bus bar TPN, 4 way vertical type, with provision of MCCB incommer, AC, 415 Volt complete all as specified & directed.
S&F MCB single pole, 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.
S&F MCB single pole, 40 to 63 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.
S&F MCB DP 32 to 63 Amps 240 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.
S&F MCB Four Pole 40 to 63 Amps 415 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.
S&F for sheet metal enclosures with two pin and earth plug sockets controlled by one No. MCB rating 20 Amps , 240 Volts grade, double door type complete.
M&L , Earthing complete with galvanisedsteel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completionI connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed.
Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.
(ii) Earthing lead and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule.
Note :- (i) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge.
Taking down carefully ceilling fans of any size, type by disconnecting the wires and dismanting blades and removing fan and blades to contractor,s workshop or site for repair/ overhauling/re winding/painting etc including re fixing after neccesary repair complete all as specified and directed by Engineer-in-charge (Note|-Parts/components will be measured and paid seperately under their respective items)
Description all as per sil item No 41 here in before but for exhaust/cabin fans of any size/make
M&L for servicing/oiling and greasing of fan of any size/type by using appropriate grade of oil/grease and replacing defective parts such as bush, bearing split pin rubber bush hanging clamp capacitor including cleaning for fixing the same as directed by Engineer- in -Charge (Note|-Parts/components will be measured and paid seperately under their respective items)
M&L for rewinding of celling fan 1200mm /1400mm sweep, AC, 230 volts single phase with super enamelled copper winding wire of appropriate size including packing, insulating material soldering varnishing assembling and testing as required complete all as specified and directed
Rewinding of exhaust fan 300mm to 450mm sweep AC 230 volts single phase with super enameled copper wire of appropriate size including packing insulating material, soldering, varnishing , assembling and testing complete all as specified
S&F bearing of celling fans for celling fans of 1200/1400mm sweep suitable for different makes /type of fans.
S&F bushes gun metal suitable for celling fans 1200/1400mm sweep/exhaust fan 300 to 450mm sweep/cabin fan of any size complete all as directed by Engr-in-Charge
S&F ball bearing suitable for exhaust fan 300 to 450mm sweep of different make, all as directed.
S&F rubber reel type synthetic rubberwith 14.5mm hole suitable for hooks of celling fans, all as specified and directed by Engr-in-Charge.
S&F condenser/capacitor suitable for 230 volts singls phase celling fan 1200mm/1400 sweep of approved make and quilty of capacity 2.5 MFD all as directed
Description all as per item No 53 here - in - before but capacity 4 MFD for exhaust fan of approved make and quality
Dismantling of geyser from its location 03/06/25/50Ltrs cap and making leak proof by means of welding of tanks replacement of parts, under item No 2 and one coat of primer for inner tank re-assembling, including packing of glass wool properly replacement of worn out nut bolts washers screws as reqd and re fixing after neccesary repair of complete set to work after one coat of synthetic enamelled paint as directed by Engr-in-Charge.
Supply and fixing of following items for geyser complete.
(a) Apparatus plate heavy duty rubber gasket suitable for 03/06/25/50 Ltr of any size and directed by Engr-in-Charge.
(b) Geyser element 1.5 KW, all as specified. Make :- Theata/Venus
(c) Geyser element 2.0 KW, all as specified. Make :- Theata/Venus
(d) Thermostate switch ISI Marked.
(e) Plug top 3pin 15 Amps
Dismounting, window AC 1.5/2.0 TR to the ground level, transporting to near water point in the complex, taking out the AC from outer cover, washing the unit with soap solution jet followed by clean water jet, drying, wiping, transporting back & re-fixing at original position complete all as specified and directed by Engr-in-Charge.
Servicing of split type AC of capacity 1.5/2.0 TR capacity of any make by washing the outdoor unit condenser coil with soap water jet followed with clean water jet and indoor unit with the help of blower, wipe and clean the unit with dry cloth complete all as specified and directed by Engg-in charge. Note:- Cost of hiring T&P i.e. blower, pressure pump bucket hose pipe deemed to be included.
M&L for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for :-
(a) Water coolers 40 to 150 ltrs cooling capacity.
(b) Refrigerator of 165 to 310 ltrs capacity.
(c) Deep freezers of Upto 425 ltrs capacity.
Taking down defective /unserviceable AC rotary compressor of any make of capacity 1.5 TR and replacing with new rotary compressor of make Tecumseh, Toshiba, Mitsubishi, Hagelin refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable AC rotary compressor of any make of capacity 2.0 TR and replacing with new rotary compressor of make Tecumseh, Toshiba, Mitsubishi, Hagelin refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable AC reciprocating compressor of make Tecumseh /kirloskar /emerson of capacity 1.5 TR , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable AC reciprocating compressor of make Tecumseh /kirloskar /emerson of capacity 2.0 TR , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge.
M&L for checking for leakages, creating vacuum, charging of R-410 gas in the unit to the required pressure complete all as specified and directed by Engr-in-Charge for the following appliances:-
(a) Split type AC 1.5/2 Ton capacity.
(b) Window type AC 1.5/2.0 Ton capacity
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply and replace capacitors of the following capactities for ACs water coolers, refrigerators, Deep frizers etc as per site requirement.
M&L for shifting of split type AC from one location to other location including fixing evaporator unit with gitties/fastner, cutting wall/concrete incl arrangement of T&P for laying copper tubing, positioning condensing unit, laying copper tubing incl brazing work, connecting drain pipe, making good disturbed surface complete all as specified and as directed by engineer-in-Charge. (Note- Any additional copper tubing required for the work is included in the item)
S&F in replacement of wire remote control ( micro- processor) unit suitable make of split type AC 1.5/ 2 TR.
Supply and replace thermostats of of following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c ) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply and replace condenser unit of the following appliances including making of all connectiions as specified and directed by Engr-in-charge following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply and replace cooling coil of following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply and replace condenser fan motor complete with necessary mounting bracke to and base frames for :-
(a) Window type AC of any make capactiy 1.5 Ton cap.
(b) Water coolers of any make and cap 40 to 150 ltrs capacity.
(c) Split type AC of any make and capcity 1.5/2 ton.
(d) Deep freezers of any make & cap 200 to 425 ltrs capacity.
S&F in replacement of PCB of split type AC Cap 1.5/ 2 TR as per existing make and model. Complete all as specified and directed by Engrs - in- charge.
S&F, replacement to air filters of split type AC of 1.5/2.0 TR capacity as per existing pattern, complete all as specified and directed by Engr-in-Charge.
S&F in replacement Submersible PVC pump for desert cooler 230 volt single phase 50 HZ complete all as specified and directed by Engineer-in-Charge. Make : Khaitan/Universal or equivalent.
S&F in replacement of fan motor copper wound for desert cooler for operation on AC single phase 230 / 250 volts 50 HZ 1440 RPM complete all as specified and directed by Engineer-in-Charge. Make:- Khaitan/ Victor/ Americal/ Universal
Supply & replacement of wood wool pad ( Set of three) heavy duty for desert cooler complete all as directed by Engr-in-charge.
Supply & fixing in replacement of capacitor 4 mfd make Usha/Universal/Epcos
Supply & fixing in replacement desert cooler fan blades made of galvanised iron sheet of appropriate thickness as directed.
M&L for cleaning after taking down complete body including fitting and fixtures of desert coolers of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparationand cleaning of surface for painting and applying two coats of synthetic enamenl spray paint inside and outside surfaces and applying two coats rubber seal paint inside the water tank, and rewriting of MES No etc, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of 3 Pin Top, 5 Amp for desert coolers, complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable water cooler (capacity 40 ltrs) reciprocating compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable refrigarator (upto capacity 260 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable Refrigrator (upto capacity 320 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable Deep frizer (capacity upto 425 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
Disconnecting and taking down old PVC tubing and connections of any description/ grade and in any position in trenches/under floors / on walls etc including all fittings/accessories and fixtures such as bends, union, elbow socket, valves, taps etc, all as directed and specified for 20 mm dia pipe complete all as specified and directed.
All as per item No. 105 here in above but 25 mm dia pipe.
All as per item No. 105 here in above but 40 mm dia pipe.
All as per item No. 105 here in above but 50 mm dia pipe.
All as per item No. 105 here in above but 80 mm dia pipe.
Supply and Fixing in any length UPVC pipe 20 mm dia pipe manufactured as per ASTM-D-1785 as per IS-559, Schedule-40 complete with fittings, laid in trenches in required length complete all as specified and directed
All as per item No.110 here in above but size (25 mm dia).
All as per item No. 110 here in above but size (40 mm dia).
All as per item No. 110 here in above but size (50 mm dia).
All as per item No.110 here in above but size (80 mm dia).
S & F in repair UPVC Ball valves with operating handle (stop valve) of size 20 mm dia complete suitable for fittings with ASTM - 1785, Schedule 40 UPVC pipes all as specified and as directed.
All as per item No. 115 here in above but of size (25 mm dia).
All as per item No. 115 here in above but of size (50 mm dia).
All as per item No. 115 here in above but of size (80 mm dia).
Excavation in trenches in soft / loose soil nexc 1.5 mtr wide and not exc 1.5 m in depth etc complete and getting out in soft soil inciuding trimming sides and bottom of trenches complete all as specified and directed by Engr-in- charge.
Rentring filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as specified and directed by Engr-in- charge.
Removing excavated surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting pointall as specified.
Ramdev and Sons
Jinendra Chemicals
Shree Krushna Supply Corporation
Dighard Electricals
Ahmed B Khatri
Ashok Electric and Electronics
Shree Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .