Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC SPECIAL 1 INDUSTRIAL ESTATE NEW POWER HOUSE ROAD JODHPUR 342003 | JODHPUR | RAJASTHAN | 342003 | ₹1.9 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹2.0 Cr+₹7.1 L (3.73%)Rejected-Finance 300 GOPAL NIWAS 3 A ROAD SARDARPURA JODHPUR CITY RAJASTHAN 342003 | JODHPUR | RAJASTHAN | 342003 | ₹2.0 Cr+₹7.1 L (3.73%) | L2 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | INDO CONSTRUCTION L1 | UTSAV INDIA LIMITED L2 |
|---|---|---|---|---|---|
| .01NOTE: Schedule ‘A’ Part I to VI are under Ser No. 1.00 to 6.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. | |||||
| 1.00 | Lump sum price worked out for BUILDINGS / STRUCTURES as listed in Sch 'A’ Part I. | 1 | Lumpsum | 7,60,000 ₹7,60,000 Lowest | 8,00,000 ₹8,00,000 |
| 2.00 | Lump sum price worked out for EXCAVATION & EARTH WORK as listed in Sch 'A’ Part II | 1 | Lumpsum | 50,000 ₹50,000 | 44,974 ₹44,974 Lowest |
| 3.00 | Lump sum price worked out for INTERNAL ELECTRIFICATION INCLUDING WIRING FOR AC as listed in Sch 'A’ Part III | 1 | Lumpsum | 2,00,000 ₹2,00,000 Lowest | 2,22,174 ₹2,22,174 |
| 4.00 | Lump sum price worked out for LIGHTENING PROTECTION as listed in Sch 'A’ Part IV | 1 | Lumpsum | 1,25,000 ₹1,25,000 Lowest | 1,31,855 ₹1,31,855 |
| 5.00 | Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch 'A’ Part V | 1 | Lumpsum | 90,000 ₹90,000 | 87,198 ₹87,198 Lowest |
| 6.00 | Lump sum price worked out for EXTERNAL ELECTRIFICATION AND DG SET as listed in Sch 'A’ Part VI | 1 | Lumpsum | 6,50,000 ₹6,50,000 | 5,40,092 ₹5,40,092 Lowest |
| 6.017. SCHEDULE `A' PART-VII MISCELLANEOUS ITEMS OF WORK (Note for items 7 to 76 The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES) | |||||
| 6.02INTRENAL ELECTRIFICATION | |||||
| 7.00 | S&F ceiling fan 1200 mm sweep, 5 star rated energy efficient, silent including provision of 3 core copper flexible cable conductor cable 23/0.0076 from ceiling rose and rotary step type regulator. | 6 | EACH | 3,000 ₹18,000 Lowest | 4,000 ₹24,000 |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
24 Apr 2025, 6:00 pmClosed
CE(AF) GANDHINAGAR
CE(AF) GANDHINAGAR, LEKAWADA, PATIA, NEAR CRPF CAMPUS, CHILODA
COMPLETION OF INCOMPLETE WORK FOR SERVICES FOR TECHNICAL ACCN AT AF STATION BHUJ
2024_MES_680585_3
87191 ROC
Open Tender
Civil Works
Lump-sum
365 days
GE(AF) BHUJ
AS PER TENDER AND NIT
7 documents required · 7 mandatory
₹1,000
GE(AF) BHUJ
₹1.9 L
20 Sept 2025
27 Mar 2025
26 Apr 2025
27 Mar 2025
24 Apr 2025
11 Apr 2025
27 Mar 2025 - 5 Apr 2025
Amount
NOTE: Schedule ‘A’ Part I to VI are under Ser No. 1.00 to 6.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for BUILDINGS / STRUCTURES as listed in Sch 'A’ Part I.
Lump sum price worked out for EXCAVATION & EARTH WORK as listed in Sch 'A’ Part II
Lump sum price worked out for INTERNAL ELECTRIFICATION INCLUDING WIRING FOR AC as listed in Sch 'A’ Part III
Lump sum price worked out for LIGHTENING PROTECTION as listed in Sch 'A’ Part IV
Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch 'A’ Part V
Lump sum price worked out for EXTERNAL ELECTRIFICATION AND DG SET as listed in Sch 'A’ Part VI
7. SCHEDULE `A' PART-VII MISCELLANEOUS ITEMS OF WORK (Note for items 7 to 76 The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES)
INTRENAL ELECTRIFICATION
S&F ceiling fan 1200 mm sweep, 5 star rated energy efficient, silent including provision of 3 core copper flexible cable conductor cable 23/0.0076 from ceiling rose and rotary step type regulator.
S&F heavy duty exhaust fan of 450mm sweep, 240V, metal body including luvers and shutters, fixed as per manufacturer instruction, connection with and including 1.5 Sqmm copper conductor, PVC Insulated and PVC sheathed three core cable complete.
S&F LED tube of 1x20 W (4 feet) 230V, 6000k, Taskline AL slim LED batten excellent energy saving and maintenance free operation, Housing made up of extruded aluminium and extruded PC diffuser complete with all accessories and all as specified and directed by EIC as per Make :- Orient Cat Model No. LBLN-20-C-ALor equivalent from Appendix 'B' . Note :- In case of equivalent model, Parameters like type of body and cover, burninig hours, temperature, lumen etc shall be strictly compared before approval.
S&F LED Security light luminaire 1x25 W having IP-65 protection, with minimum system efficiency as>85%, made of PRESSURE DIE CAST housing toughned glass in the front and peanut lens for batwing light distribution with excellent thermal management. The fitting should have rated CCT 6000 K complete with all accessories like bracket clamp etc all as specified and directed by EIC. Make Orient cat model No. LSFS-025-CF or equivalent from Appendix 'B' . Note :- In case of equivalent model, Parameters like type of body and cover, burninig hours, temperature, lumen etc shall be strictly compared before approval.
Fixing only DB SPN 8 way with 200 Amps copper bus bar 250 Volts double door, sheet metal enclosure, dust and vermine proof IP 43 protection, flush to wall including minor items complete all as specified and directed Note: SPN will be issued under Sch B at the rates mentioned therein
S&F MCB TPN 415 Volts, 32 Amps, "C" series, 10KA (RATE ONLY)
S&F MCB TPN 415 Volts, 63 Amps, "C" series, 10KA (RATE ONLY)
Fixing only MCB SPN 240 Volts, 6 to 40 Amps, "C" series, 10KA including minor items complete all as specified and directed Note: DB SPN will be issued under Sch B at the rates mentioned therein
S&F MCB SP 230 Volts, 5 to 30 Amps, "C" series, 10KA
S&F slim edge lit type recessed mounting LED luminaire with white acrylic flat light dissipater with LED light source of 36 Watt, size 2'x2'square shape suitable for modular ceiling including cutting the false ceiling and fixing including provision of 3 core flexible copper wire 23/0.0076 from ceiling rose to light fitting complete all as specified and as directed by EIC.
Taking down carefully the existing T5 light fittings and removal from site complete and making good the disturbed surfaces as directed.
M&L for Submain wiring with 04 runs of 4 Sqmm and one run of 4 Sqmm as earth continuity, 1100 V grade PVC insulated, unsheathed FRLSH grade copper conductor cable signle core multistranded ISI marked (IS-1536-1977) drawn through PVC casing capping medium grade ISI marked including accessories such as bendes, supports etc all as specified. (RATE ONLY) Note : 4 runs of conductor with two runs of earth wire including conduit/casing caping shall be measured as one unit.
M&L for Submain wiring with 04 runs of 6 Sqmm and one run of 6 Sqmm as earth continuity, 1100 V grade PVC insulated, unsheathed FRLSH grade copper conductor cable signle core multistranded ISI marked (IS-1536-1977) drawn through PVC casing capping medium grade ISI marked including accessories such as bendes, supports etc all as specified. (RATE ONLY) Note : 4 runs of conductor with two runs of earth wire including conduit/casing caping shall be measured as one unit.
M&L for Submain wiring with 04 runs of 10 Sqmm and one run of 10 Sqmm as earth continuity, 1100 V grade PVC insulated, unsheathed FRLSH grade copper conductor cable signle core multistranded ISI marked (IS-1536-1977) drawn through PVC casing capping medium grade ISI marked including accessories such as bendes, supports etc all as specified. (RATE ONLY) Note : 4 runs of conductor with two runs of earth wire including conduit/casing caping shall be measured as one unit.
M&L for Submain wiring with 02 runs of 6 Sqmm and one run of 6 Sqmm as earth continuity, 1100 V grade PVC insulated, unsheathed FRLSH grade copper conductor cable signle core multistranded ISI marked (IS-1536-1977) drawn through PVC casing capping medium grade ISI marked including accessories such as bendes, supports etc all as specified. (RATE ONLY) Note : 2 runs of conductor with one run of earth wire including conduit/casing caping shall be measured as one unit.
M&L for Submain wiring with 02 runs of 4 Sqmm and one run of 4 Sqmm as earth continuity, 1100 V grade PVC insulated, unsheathed FRLSH grade copper conductor cable signle core multistranded ISI marked (IS-1536-1977) drawn through PVC casing capping medium grade ISI marked including accessories such as bendes, supports etc all as specified. (RATE ONLY) Note : 2 runs of conductor with one run of earth wire including conduit/casing caping shall be measured as one unit.
EXTERNAL ELECTRIFICATION
Laying & testing of XLPE, insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavyduty) with aluminium conductor, 11000 volts, Earthed grade of size 3 core 120 Sqmm complete all as specified and as directed. Note: XLPE CABLE will be issued under Sch B at the rates mentioned therein
Supplying and laying un-reinforced precast concrete cable cover, class HV type 1, flat of size 300mm x 180mm x 40mm with embosed laters "HT CABLE" complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV type 2, flat of size 300mm x 180mm x 40mm with embosed laters "LT CABLE"complete all as specified and as directed.
Laying, jointing and testing of underground cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core x 185 sqmm laid in trenches, ducts, fixed wall / pole etc complete. Note: XLPE CABLE will be issued under Sch B at the rates mentioned therein
Supply,Laying, jointing and testing of underground cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core 150 Sqmm laid in trenches, ducts, fixed wall / pole etc complete. (RATE ONLY)
Supply,Laying, jointing and testing of underground cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 Core 25 Sqmm laid in trenches, ducts, fixed wall / pole etc complete. (RATE ONLY)
Supply,Laying, jointing and testing of underground cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 Core 16 Sqmm laid in trenches, ducts, fixed wall / pole etc complete. (RATE ONLY)
M&L for chemical earthing with copper earth plate electrode (98 percent conductivity when annealed) of size 900mm x 600mm x 5 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to and including copper earth strip 32mm x 6mm by means of copper bolts nuts check nuts and washers returning and filling the pit with excavated soil mixing with charcoal 250 kg, crystal salt 200 kg, magnesium sulphate of 100 kg and vegetable soil all around the plate up to 350 mm above from top edge of plate and balance portion filling with excavated soil in layers not exceeding 25mm thick, 25mm bore galvanised iron medium grade watering pipe, 40mm bore galvanised iron light grade pipe for earth strip protection, including all excavation earth work in any type of strata, PCC 1:3:6 type C1 for chamber of internal size 300 mm x 300 mm x 300 mm with 120 mm thick wall and 700 mm x 700 mm x 150 mm thick bed concrete, RCC 1:2:4, type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.00 Kg/Sqm) with cast iron frame, funnel with wire mesh, 25 mm bore medium grade GI watering pipe, lugs 80 mm bore medium grade GI protection pipe, test point etc complete all as specified and directed.
Note :- (i) Quoted rate shall deemed to include provn of earth strip with protection pipe up to 7.5 M length. (ii) Earthing resistance shall be less than 1.0 Ohms. After completion of work all earthing shall be tested by the contractor in presence if Engr-in-Charge. Test result shall be recorded and signed by the contractor & Engr-in-Charge. If contractor fail to achieve the above result, the same shall be rectified by the contractor without any extra cost of Govt. The earthing result with required to maintain up to end of defect liability period of one year and if any variation found in earthing result during defect liability period same will be intimated to the contractor by Engr-in-Charge and contractor shall rectify the same. The quoted rates shall deemed to include for above said provn.
Suppy and install automatic power factor correction (APFC) panel for three phase, 415 volts and 50 Hz system of capacity, 60 KVAR with-01 No, MCCB TPN 125 Amps 25 KA (Incoming), 8 step capacitor bank (20+10+10+5+5+5+3+2) KVAR, microprocessor system complete with suitable protection fuses/MCBs, relays, spare compartment to install new capacitor in future complete with incoming and outgoing PF Meter, volt meter, ampere meter, neon bulb set of three for incoming and for each step of capacitor bank complete all as specified and directed.
Supply, Installation, testing and commissioning of outdoor type unipack 11kV. 315 KVA complact sub station enclosure of "Nonwalk in type" with ONAN Transformer and including of following components :- HT SWITCHGEAR 11kV 630 Amps, 21 KA for 3 sec, SF6 insulated Non-Extinsible Compact switchgear (Type V+M) consisting of 1 No. Fixed MANUAL Vaccum Circuit Breaker with Microprocessor based self Powered relay in SF6 insulated stainless steel enclosure, with series trip, self powered microprocessor based numerical over current relay (IDMTL+Inst) protection along with metering module of Class 1.0 Accuracy. Interconnection between HT switchgear and transformer shall be using 1Cx3x95 sqmm AI, unarmolured XLPE cable Self powered over current and earth fault protection Relay of Ashida make - ADR141S CT of ratio : 40/1A, 2.5VA, CL-10P10 for Protection. CT of ratio : 50/1A, 2.5VA, CL-1.0 for Metering PT- 11KV/√3/110V/√3, 25VA, CL-1 Multifunction Meter of CL - 1 accuracy. Space Heater (230V AC) Manometer
TRANSFORMER (AS PER IS-1180) 315KVA, 11KV/433V DYn11 Copper wound Oil filled hermatically sealed transformer with corrugated wall without conservator type of design & Top Bushings for HT & LT with off load tap switch of range +5% to -5% in steps of 2.5% Class-A, Temp Rise - Oil/Winding 35/40 Deg ce. Losses (subject to IS 1180) Max Losses at 50% loading : 1050Watts, Max Losses at 100% loading : 3150 Watts and impedance of 4.5% (subject to IS Tol). (Make : Nucon) WTI & OTI with Alarm & Trip Contact. Low Voltage Switchgear - 400A Aluminium Busbars (100% for Phase & 50% for Neutral, Current Density - 1amps/sqmm) Incoming 630 Amps, 433V 3P 50Hz 50KA Fixed Manual Type Moulded Case Circuit breaker (MCCB) with thermal magnetic release for over load and short circuit protection. 01 No. Digital multifunctional meter with accuracy class-I, make:- Secure RYB indicator Outgoings 100 Amps 433V 3P 50Hz 36KA Fixed Manual Type Moulded Case Circuit breaker (MCCB) with thermal magnetic release for over load and short circuit protection 02 No. 250 Amps 433V 3P 50Hz 36KA Fixed Manual Type Moulded Case Circuit breaker (MCCB) with thermal magnetic release for over load and short circuit protection 02 No.
OUTDOOR ENCLOSURE Outdoor type enclosure having modular construction of Galvanised Sheet Steel of thickness 2mm and shall have IP54 degree of protection of HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment duly powder coated (colour Light Gray & D A Gray). Each compartment provided with the door and pad locking arrangement. The compartment illumination lamp with door operated switch shall be provided for each compartment. Interconnection & Earthing Interconnection between HT switchgear & transformer using 1Cx3x95Sqmm XLPE single core cable & interconnection between transformer & LT switchgear using copper busbars. Internal earthing connections by using 50x6 mm GI Strips including transformer neutral. (Note :- The quoted rates also include the following scope:-) Package Sub station complete with the internal interconnections & earthing. Accessories for the external connections of HT & LT cables like termination kits, lugs, glands etc & extending of earth bar up to earth pits PCC 1:2:4 upto 30CM over 100mm thick PCC 1:5:10 sub base above GL for placing CSS and channel fencing to cover the CSS with gate arrangement.
Supply, Installation, testing & commissioning power one make 120 KVA, 3 Phase input 3 phase output IGBT Based true on line UPS with SMF Batteries to provide 10 Min Backup time as per the specifications. Full IGBT- Reliable double conversion UPS ensures the critical load Topology true online double conversion parallel configuration up to 30 modules (up to 1.2 MW) UPS type modular (Decntralized parallel Architecture) Power factir 0.99 High input voltage tolerance-load<100%(-20%,15%),<80%(-2626%,+15%)<60%(-35%,+15%) High input frequency tolerance (35-70Hz) AC-AC efficiency up to 95.5% Ripple - free battery charging Compact size forspacesaving Flexible battery block per string for minimal environment impact
DG SET
Supply, install, testing and commissioning of Diesel Engine driven generating set 250 KVA, 3 Phase, 4 wire, 415 Volts, 1500 RPM, 50 Hz power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integral acoustic enclosure having silent features such as modular bolted construction with fabrication on imported CNC torret punch machines, nine tank treatment process with pure polyster based powder coating to ensure long life in all weather conditions and for out door application/ installation, integrated design there by facilitating / easy handling installation & shifting of the equipment at site. Compliance standard of DG set should be confirming to ISO-8728/ Noise Pollution Norms of MoEF & Certified by ARAI, Pune. The design of integral acoustic enclosure should be any type approved by national Physical laboratory as per Control Board CRDI STD(CPCB-IV+) latest norms/ regulation with fuel tank, battery and standard accessories, acoustic enclosure, vibration pad, tools and spare,as provided by manufacturer, PCC foundation as per OEM all as specified and as directed with the following specifications :-
(A) ENGINE -Greaves make model 6G11TAG41 or equivalent model from make specified in Appx B, direct injection, 6 cylinders , water cooled, compression ignited turbo charged and charged water cooled diesel engine 303.4 HP at 1500 RPM and compling with BS 5514/ISO 3046 standard :- (i) 12V electrical starting system consisting of starter motor, charging alternator and 12 V 180 AH battery. (ii) Dry type Air cleaner with restriction indicator (iii) In-line Fuel injection system with Electronic Governor (iv) Spin-on Lube oil filter elements (iv) Radiator, Air-to-Air after cooler, pusher fan & fan drive arrangement, Gear driven water pump (v) Sensor for oil pressure, Coolant temperature & level (iv) First fill of Lube oil. (API CF4 grade, Greaves Maxtherm Lube or equivalent)
Controller provide configurable time delay of 0-300 sec to start after remote start signal and time delay of 0-600 secs prior to shutdown after stop signal. Sleep mode increase battery life. Configurable current setting from low to minimize current draw when genset is not working. Engine Protective Functions includes :- Configurable alarm output emergency stop : Annunciated whenever an emergency stop signal is received by the control (a) Low Lube oil pressure warning and shutdown (b) High engine water temperature warning / shutdown (c) Low coolant temp warning (d) sensor failure indication (e) Low and high battery voltage warning (f) Weak battery warning (g) Fail to start shut down (h) Cranking lockout : Control will not allow the starter to engage or to crank the running engine (j) Cyclic cranking : Configurable for the number of starting cycle (1 to 7) and duration of crank and rest periods (k) Alternator Protective functions includes (l) High and Low AC voltage shutdown (m) Under and over frequency shutdown / warning (n) Loss of sensing voltage input shutdown Fuel tank( In built fule tank)
AMF PANEL OUTDOOR TYPE :- The AMF Panel OUTDOOR TYPE suitable for 250 KVA DG set factory made out of CRCA Steel 16 SWG Sheet, floor mounted type and front operated type, totally enclosed dust, damp and vermin proof, all doors and joints will be suitable gasketed to form dust and vermin proof. The panel would be powder coated with minimum thickness of 50 microns, stove enameled paint finished after elaborate pre-treatment to form a long lasting characteristic. The control panel will be complete in all respect with fuses, wiring and labels etc, the following will be incorporated in the AMF Panel :- (i)Multifunctional meter digital (Amp+Volt+PF+Hz+KW+KWH)-01 No. (ii) Alternator voltage monitor 01 No (iii) Main voltage monitor - 01 No (iv) Ammeter DG Analog - 01 No (v) Voltmeter DG Analog - 01 No (vi) MCBs of suitable range (vii) Main Power contactor -4 pole of capacity 300 Amps -01 No (viii) DG Power contactor -4 pole of capacity 300 Amps - 01 No (ix) Indicator Lamp - 02 Nos (x) MCB (For control ckt)-10 Nos (xi) Auxiliary Contactor -02 Nos (xii) Automatic battery 24 volt charger-01 No (xiii) Terminal O/L relay - 01 No (xiv) Terminals (for control cable)-06 Nos (xv) One set of copper bus bar of suitable capacity.
Note :- Platform for DG Set shall be provided as under:- precast cement concrete block masonry type 1;5:8 using 20mm graded aggregate with solid blocks, exc 10cm in width and set in CM 1:6 over PCC 1:5:10 foundation concrete, 15mm thick plaster in 1:4 and 2 coats of cement base paint complete for foundation of DG set all as directed. The quoted rate shall deemed to include provision of platform as stated above.
EXTERNAL WATER SUPPLY
S & F Rotational moulded polyethylene water storage tank, triple layers (cylindrical vertical with closed top) hoisted and fixing in position of capacity 10000 litres all as specified and directed.
S & F Rotational moulded polyethylene water storage tank, triple layers (cylindrical vertical with closed top) hoisted and fixing in position of capacity 5000 litres all as specified and directed.
AIR CONDITIONING
Installation, testing and commissioning of factory designed pre-fabricated and floor-mounted water vapour compression scroll-type water-cooled chiller machine complete with hermatic scroll compressors with independent refrigerant circuits, water-cooled S/T type condenser, S/T horizontal flooded type evaporator with carbon steel shell and seamless copper tubes with elastomeric insulation, common base frame, interconnected copper refrigerant piping and wiring, vibration isolators, gauge panel, automatic safety controls, flow switch at evaporator and condenser and ozone friendly CFC-free refrigerant gas R134a/407C. The quoted price shall be inclusive of a unit mounted automatic star/delta starter (to ensure that the starting current does not exceed twice the full load current), victaulic coupling, system integrator capable of giving industry standard (modbus/bacnet) output to BMS for critical parameters. Mapping shall be required for all critical points displayed on the chiller control panel. The chiller shall be BMS compatible and shall have RS485/RS232 serial communication protocol; the motor shall be suitable for 3- Phase, 415 V ± 10%, 50 Hz AC electric supply; electric panel shall have an IP 54 rating. Note: i) Water Cooled Scroll Chiller unit as lying at site will be issued under Sch B for incorporation at the rates mentioned therein. ii) Contractor shall inspect the material being issued under Sch B, assess for the balance items and minor repairs required to make it fully functional and the rates quoted shall included for these elements and no extra payment shall be paid on this account. iii) Necessary civil work viz. PCC foundation for placement of chillers shall be provided as per instructions of manufacturer and EIC. The quoted rate shall deemed to include provision of civil work like foundation and platform etc. The chiller shall be as per the approved particular technical specifications and shall meet the following design criteria:-
[a] Chiller [i] Chilled Water IN: 53.6° F [ii] Chilled Water OUT: 44.6° F [iii] Fouling Factor: 0.000018 (in FPS units) [iv] Water Flow Rate: 2.4 US-gpm/TR [b] Condenser [i] Condenser Water IN: 90° F [ii] Condenser Water OUT: 98.5° F [iii] Fouling Factor: 0.000044 (in FPS units) [iv] Water Flow Rate: 4.00 US-gpm/TR Scroll-type water-cooled chiller of nominal capacity in standard manufacturer's range corrosponding to actual capacity not less than 26 TR and suitable for ambient environmental conditions. Note :- (i) The Plant shall meet inside condition of DBT 20+/-2 degree C and 60+/-5% RH. (ii) The tonnage stated is indicative contractor to work out heat laod calculation prior to quoting. Any increase in tonnage due to actual calculation shall be deemed to be included in the bid & it will be the sole responsibility of the L1 to maintain inside condition of temperature and humidity through out the year/all weather condition.
Supply, installation, testing and commissioning of monoblock, self-priming, single-stage, centrifugal volute type pump suitable for 7.1 LPS water flow and 32 MWC head alongwith elastomeric insulation having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage induction motor having IE- 4 efficiency and conforming to IS: 12615- 2018, base plate, mounting channel frame, elastomeric insulation, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply complete all as specified and directed. Necessary civil work viz. foundation for placement of pump, mounting of star/delta starter panel and pump accessories shall be provided as per instructions of manufacturer and EIC and the cost shall deemded to included this provisions in quoted rate.
Supply, installation, testing and commissioning of FRP rectanguler shape vertical induced draught counter flow cooling tower of nominal cooling capacity 60 TR with uniform water distribution and optimal heat transfer, having tough fiberglass reinforced plastic (FRP) casing of sufficient structural strength to withstand vibrations and wind velocity upto 60 m/s, FRP basin, rigid honeycomb type PVC fill of suitable thickness, SS sprinklers and non-clogging sprinkler pipes, FRP drift eliminator, energy efficient induced draught axial type fans with factory set and dynamically balanced blades pitch, TEFC squirrel cage high efficiency induction motor with IP 65 protection suitable for 3- Phase, 415 ± 10% V, 50 Hz AC electric supply, inlet, outlet, drain and over-flow nozzle connections, etc. Necessary civil work viz. PCC foundation for placement of cooling towe, etc. shall be provided as per instructions of manufacturer and EIC and the cost shall deemded to included this provisions in quoted rate. The cooling tower shall be as per the approved particular technical specifications.
Supply, installation, testing and commissioning of monoblock type, self-priming type, single-stage, centrifugal volute type pump suitable for 7.25 LPS water flow and 10 MWC head having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage induction motor having IE- 4 efficiency and conforming to IS: 12615- 2018, base plate, mounting channel frame, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply complete all as specified and directed. Necessary civil work viz. foundation for placement of pump, mounting of star/delta starter panel and pump accessories shall be provided as per instructions of manufacturer and EIC and the cost shall deemded to included this provisions in quoted rate
Supply, installation, testing and commissioning of double-skin type horizontal, floor-mounted, top/side discharge air handling units having corrosion resistant extruded aluminum hollow profile with thermal break, heavy gauge galvanized steel channel base frame, 43 mm double skin panel with pressure injected CFC & HCFC free PUF with 'k' value of 0.02 W/°C m & density 40 kg/cum, pre-coated pre-plasticized galvanized outer and inner skin 0.60mm thick, air-tight casing using gaskets and self-adhesive tapes, AMCA certified energy efficient fans with double inlet double width forward or backward curved impellers for high static pressure mounted on aluminum extruded slide rail base frame, chilled water coils with combination of 6 rows deep with anti-corrosion Aluminum fins, PVC Naylon hinges & handles, view port and marine lamp, limit switch, SS-304 drain pan, 10 micron pre-filters, inspection windows/doors, mixing box and supply/return/fresh air dampers. Necessary civil work viz. PCC foundation for placement of AHU, mounting of VFD panel, etc. shall be provided as per instructions of manufacturer and EIC and the cost shall deemded to included this provisions in quoted rate. The AHU shall be as per the approved particular technical specifications and the following design criteria.
[a] Suitable DIDW fan with AMCA certified blower having outlet velocity not exceeding 9.2 m/s [b] 4 Pole, TEFC, high efficiency, squirrel cage induction motor drive having BHP rating 20% higher than the peak capacity, suitable for 415 V ±10%, 50 Hz, 3-Phase AC power supply [c] V-belt drive assembly with pulleys, belt, guard, etc., double canvass connections with zip to discharge duct/plenum, etc. [d] 50 mm thick, washable HDPE, 90% down 10 micron pre-filters, filters, fixing framework, hinge type access doors, etc. [e] 6 row deep chilled water coil section with copper fins and copper tube tested on 21 kg/sq cm with SS sandwiched drain tray, etc. [f] 18 gauge MS CRCA duly powder coated AHU sub panel board in compartamentalised construction with incomer and outgoing feeders for AHU motor, 3-way valve actuator motor, fire damper actuator motor, etc. complete with required variable frequency drive, relays, timers, contactors, PT, push buttons, switches, internal wiring, etc having following parameters :-
(a) 25000 CFM with 7 X 2 kW strip heaters
(b) 15000 CFM with 4 X 2 kW strip heaters
S&F Stainless steel (Grade -304) closed expansion tank of capacity 500ltrs, pressure rating to suit the system pressure and sized adequately to compensate for water expansion due to operating temperature variations, conforming to IS: 2825- 1969 for 'non-fired pressure vessels' complete with inter-connection piping, non-return valve, safety relief valve and pressure gauge, insulated with 50 mm thick insulation and cladded with 26 G aluminium.
S & F HDPE expansion tank of capacity 5000 ltrs (for cooling tower), pressure rating to suit the system pressure and sized adequately to compensate for water expansion due to operating temperature variations, conforming to IS: 2825- 1969 for 'non-fired pressure vessels' with interchangeable EPDM-BUTYL rubber membrane complete with inter-connection piping, non-return valve, safety relief valve and pressure gauge etc.
S & F of MS ERW Class 'C' condenser water piping of following sizes, with all necessary fittings i.e. bends, tees, reducers, flanges, structural support, wooden blocks, air-purge valves, drain-valves, etc. as specified in particular specifications.
(a) 80 mm NB
(b) 65 mm NB
Supply, installation, testing and commissioning of PN 1.6 rated double flanged short & long body type butterfly valve of following sizes, designed, manufactured and tested as per IS: 13095 (1991), suitable for isolation and throttling services, having CI body & disc, SS AISI 304 disc seal, CS clamping ring and SS AISI 410 shaft and flange drilling standard end connection with accessories as specified in particular specifications.
(a) 80 mm NB
(b) 65 mm NB
(c) 40 mm NB
Supply, installation, testing and commissioning of PN 1.6 rated swing check type multidoor reflux valve (NRV) of nominal bore 65mm, designed & tested as per IS: 5312-2 (1986), suitable to handle clear water having turbidity up to 5000 ppm, having CI body, door and diaphram, leaded tin bronze seat rings and flange drilling standard end connection, etc. with accessories as specified in particular specifications.
Supply, installation, testing & commissioning of Y-type strainer of nominal bore 65mm with CI / MS body, bolted cover, flanged ends, basket of brass/ bronze / SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection duly insulated with closed cell elastometric nitrile rubber of minimum 45 kg/m³ density, thermal conductivity 0.037 W/mK or better at 20 ⁰C mean temperature class ‘O’ insulation applied by suitable rubber based adhesive covered with a layer of 120 g/m² polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding and accessories complete all as specified and directed.
Supply, installation, testing & commissioning of manual balancing valve of following sizes suitable for PN 1.6 pressure rating, having built-in measuring facility, with CI body, flanged connection, EPDM coated disc with long pitch, etc. conforming to BS 7350 for condenser water circulation complete all as specified.
(a) 80 mm NB
(b) 65 mm NB
M & L for UPVC pipe 25mm nominal bore and fittings, resistant to chemical & electromechanical corrosion, conforming to EN 1452-2, having specific gravity 1.43, shore hardness 70°C to 90° C, tensile strength 500 kg/sq.cm, bending strength 950 kg/sq.cm, modulus of elasticity 3.2 X 10 kg/sq.cm and dielectric strength > 40 kV/mm complete with accessories as specified in particular specification.
Supply, installation, testing and commissioning of MS ERW Class 'C' chilled water piping of following sizes with all necessary fittings i.e. bends, tees, reducers, flanges, structural support, wooden blocks, air-purge valves, drain-valves, etc. thermally insulated with elastomeric insulation of 25mm thick with rapped water prof fabric cloth as specified in particular specifications.
(a) 65 mm NB
(b) 50 mm NB
(c) 40 mm NB
Supply, installation, testing & commissioning of Y-type strainer of following sizes with CI/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection with elastomeric thermal insulation of suitable thickness and accessories as specified in particular specifications.
(a) 50 mm NB
(b) 40 mm NB
Supply, installation, testing and commissioning of PN 1.6 rated double flanged short & long body type butterfly valve of following sizes designed, manufactured and tested as per IS: 13095 (1991), suitable for isolation and throttling services, having CI body & disc, SS AISI 304 disc seal, CS clamping ring and SS AISI 410 shaft and flange drilling standard end connection with elastomeric thermal insulation of suitable thickness and accessories as specified in particular specifications.
(a) 50 mm NB
(b) 40 mm NB
Supply, installation, testing and commissioning of PN 1.6 rated swing check type multidoor reflux valve (NRV) of size 50mm nominal bore, designed & tested as per IS: 5312-2 (1986), suitable to handle clear water having turbidity up to 5000 ppm, having CI body, door and diaphram, leaded tin bronze seat rings and flange drilling standard end connection, etc. with elastomeric thermal insulation of suitable thickness and accessories as specified in particular specifications.
Supply, installation, testing and commissioning of CI 3-way mixing valve (temperature control valve) of following sizes, suitable for operation up-to 10 bar, with electronically operated actuator for AHUs. Water flow through the valve shall be regulated by rotation of brass slipper between the main and the bypass ports; it shall be possible to manually rotate the brass slipper through 360° and interchange the main and the common ports, to facilitate installation at site. All internals of the valve shall be rust-proof and the 'O' ring shall be of elastomeric insulation. The valve actuator shall be of electronic type with DC motor, the actuator's angle of rotation shall be 90°, it shall be without any limit switches and shall be overload-proof. It shall have an indicator to indicate the position and push-button to disengage the gear train for manual operation. All complete as specified in particular specification.
(a) 50 mm NB
(b) 40 mm NB
S & F of CL 150 # rated ball valve of following sizes, designed & manufactured as per IS: 9890 (1981) and tested as per BS 6755 Part- I, having floating type three piece design, CS body, SS- 304 ball, PTFE seal/packing/gasket, CS fastners and lever and screwed/socket weld end connection, etc. with accessories as specified in particular specifications.
(a) 25 mm NB
(b) 40 mm NB
Supply, installation, testing and commissioning of automatic air-vent valve having 19mm end connections with Brass OT 58 body and cover, polyacetal lever, high density expanded polyethylene float, EPDM rubber plug, stainless steel spring, polyamide capm etc. suitable for maximum operating pressure of 16 bar and maximum operating temperature 115° C respectively, installed on all high points in the water piping system to automatically remove the trapped air, installed on all high points in the water piping system to automatically remove the trapped air, all complete as specified in particular specifications.
Supply, installation, testing and commissioning of glycerin filled bimetallic thermometer having temperature guage 150mm dial size for temperature range 0° C to100° C in compliance to EN 13190, having standard range 0° C to 60° C up to 400° C, IP 67 protection, bimetal coil sensing element, accuracy class 1 as per EN 13190, stainless steel casing, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 stem and connection, aluminum dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), toughened glass window, neoprene filling plug and gasket complete with accessories, etc. as specified in particular specifications.
Supply, installation, testing and commissioning of glycerin filled pressure gauge of 100mm dial size for pressure range 0 psi to 200 psi in compliance to EN837-1, having standard range 15 to 0 psi and 16 psi to 10000 psi, IP 67 protection, accuracy class ±1.6% of FS, stainless steel casing and TIG argon welded socket to case, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 bourdon, socket, SS dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), polycarbonate glass window, neoprene blow off disc and filling plug, silicon gasket complete with accessories, etc. as specified in particular specifications.
Supply, installation, testing & commissioning of manual balancing valve of following sizes suitable for PN 1.6 pressure rating, having built-in measuring facility, with CI body, flanged connection, EPDM coated disc with long pitch, etc. conforming to BS 7350 for condenser water circulation complete all as specified.
(a) 50 mm NB
(b) 40 mm NB
Supply, installation, testing and commissioning of pre-fabricated galvanized steel sheet (G.S.S.) square/rectangular ducting of following types for supply/return air, fabricated from galvanized steel sheet, having zinc coating of 160 gm/sq m total on both sides complete with gaskets, elbows, splitters, vanes, supports etc. as per IS: 655/1963 with required scaffolding work to install the ducts at site :-
(a) 24 G (MS angle flanges)
(b) 22 G (MS angle flanges)
(c) 20 G (MS angle flanges)
Supply, installation, testing and commissioning of fire damper of following type complete with smoke detector/thermister, fusible link etc. and actuator as required for operation. The fire dampers shall be spring activated on melting of fusible link having melting point 67.13° C. The fire damper shall be located in the SA/RA ducts, at all fire rated crossoevers (shafts, walls, etc.). The control panel shall be located in such a way that the reset can easily be done. These combination smoke and fire dampers shall be interlocked with the building management system for the fire detection or HVAC and shall trip/close in the event of fire/smoke in the respective zone. Fire damper shall be tested as per ULL- 555 and certified by CBRI. The fire-damper shall be of at least 120 minutes fire-rating as per the approved particular technical specifications and shall meet the following design criteria:- [a] Bare fire dampers with 400 mm sleeve [b] Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position. [c] Interconnection wire for the fire detection & alarm system with the AHU and the smoke dampers [d] Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the recommandations of the manufacturer and specifications.
(a) Motorized, spring return type, combination fire and smoke damper
(a) Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position.
S & F open-cell engineered nitrile rubber foam acoustic insulation 18mm thick having good sound absorption, damping and barrier properties, antimicrobial product protection, thermal conductivity, as per EN 12667, not exceeding 0.047 W/mK at 20° C, density 140-180 kg/cum and conforming to class 1 rating for surface spread of flame in accordance with BS 476 Part 7 & UL 94 (HB, V-0). The acoustic insulation material shall be free of dust and fibre; it shall pass fungi/mould resistance as per DIN EN ISO 846 method A and bacterial resistance as per DIN EN ISO 846 method C and air erosion resistance test in accordance to ASTM Standard C 1071-05 without any laminate or covering (section 12.7) from an independent accredited testing agency, all complete as specified in particular specifications.
S & F closed cell elastomeric nitrile rubber of following sizes with aluminum foil laminated on one side, having thermal conductivity not exceeding 0.037 W/mK at mean temperature of 20° C as per EN 12667, moisture diffusion resistance factor or ‘µ’ value of minimum 7,000 for base insulation material without the foil as per EN 12086, fire performance such that it passes Class 1 as per BS476 Part 7 for surface spread of flame and also fire performance of V0, HB as per UL 94, 1996, density without the foil between 40 to 55 kg/cum. The insulation material shall be FM (Factory Mutual) USA approved and dust & fibre free. The Aluminium foil shall be 60 microns thick and its weight shall be 193 gsm as per EN ISO 2286-2, tensile strength 90 N / 15 mm as per EN ISO 527-3 with elongation > 10% as per EN ISO 527-3. All complete as specified in particular specifications :-
(a) 13 mm thick thermal insulation for SA ducts
(b) 9 mm thick thermal insulation for RA ducts
Supply, installation, testing & commissioning of removable supply/return air diffusers/grilles lovures with volume control damper of extruded aluminum sections duly powder coated with volume control damper.
Supply, installation, commissioning and testing of factory made, CPRI type tested, indoor, cubical compartmental type "HVAC Panel", conforming to IEC 61439- 1 & 2, having both sides openable with hinged double doors & locking arrangement and IP 42 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed on wall/floor with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed.
The HVAC Panel shall comprise of the following: [a] Busbar Chamber: [i] Copper busbar of rated capacity 800 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01 Set (3P + N) [b] Incoming: [i] 630 A, 415 V, Ics = Icu = 36 kA, 50 Hz, FP MCCB with adjustable overload settings (0.36- 1 X In) & tr = 0.5 - 16 s, adjustable short-circuit settings (1.5 - 10 X Ir), adjustable earth- fault settings (0.2- 1 X In), current limiting type double break roto active type, instanteneous protection and microprocessor based trip unit- 01 Nos. [ii] LED phase indicators (Red, Yellow, Blue)- 01 Set [iii] Power Measurement Device with Class 1 accuracy, complying to IEC 62053- 22, 64 samples/cycle, 31st harmonic analysis, RS485, calibration LED, third party accuracy test certificate- 01 Nos. [c] Outgoing: [i] 125 A, 415 V, Ics = Icu = 25 kA, 50 Hz, FP MCCB with adjustable overload settings (0.36- ` X In) & tr = 0.5 - 16 s, adjustable short-circuit settings (1.5 - 10 X Ir), adjustable earth- fault settings (0.2- 1 X In), current limiting type double break roto active type, instanteneous protection and microprocessor based trip unit- 04 Nos. [i] MCCB 63 Amp, 10 kA, 415V, FP -03 Nos [iii] 20 A, 10 kA, 415 V, 50 Hz FP MCB (c -curve)- 3 Nos. [iv] 32 A, 10 kA, 415 V, 50 Hz FP MCB (c -curve)- 8 Nos. [v] 40 A, 10 kA, 415 V, 50 Hz FP MCB (c -curve)- 2 Nos. [vi] LED phase indicators (Red, Yellow, Blue)- 3 Set
Supply, installation, commissioning and testing of Variable Frequency Drives(VFD) of power size 4 kW with IP 55 enclosures and mains disconnect switch comprising of the following: [a] Built in dual 5% impedance DC link reactor (harmonic filters) on the positive and negative rails of the DC bus of the Variable Frequency Drive. [b] Built in EMC filters (electro magnetic compatibility filters) for restriction of conducted emissions to comply with IEC61800:3 (un restricted distribution) :2004 Category C 1 (50 meter). [c] Three feedback PID controller having capability to simultaneously accept 3 feedback signals from temperature sensors or pressure sensors for process optimization and accordingly control the speed of the AHUs or pumps. [d] Integral graphical keypad.
All as per Item No. 69 above but variable frequency drive (VFD) of power size 7.5kW
All as per Item No. 69 above but variable frequency drive (VFD) of power size 11 kW
M & L for ISI marked 1.1 kV grade aluminium conductor, XLPE insulated armoured cables of size 4 core 10 sqmm , conforming to IS: 7098 (Part 1)- 1988 having stranded aluminium compact shaped conductor as per Cl. 2, IS: 8130- 1984, PVC inner sheath, single armouring of galvanized steel strip/wire and PVC Type ST- 2 outer sheath conforming to IS: 5831- 1984, including termination complete as specified and directed.
All as per Item No. 72 above but size 3.5 core 25 mm²
All as per Item No. 72 above but size 3.5 core 70 mm²
FALSE CEILING FOR DAIRIN LAB
M&L for False ceiling by providing anodised aluminium snap grid frame work and panel of size 60cm x 60cm x 1.2cm thick perforated particle board / tile for insulation and accoustic purpose fixed with screws to frame work all as specified and shown on Drg No. CEAA/TD/68.
Supply, install, commissioning and testing of commercial Air curtain unit for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ made out of MS/CRCA sheet of minimum thickness 18 guage finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS - CRC 18 guage square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzle etc, complete with fittings and accessories so as to product 1- 1.5 m/sec air velocity at floor level for door opening as specified for size 52x78 inches.
NOTE : Amount of credit of Rs. 25008.60 for retrieved materials is mentioned in schedule of credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
UTSAV INDIA LIMITED (BID ID -3283732)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .