Construction of HDO Office Cum Store At Batalik by way of Electrification (Under Capex)
2025_PWD_18130_3
E tender 116 of PW RnB Division 2nd Kargil
Open Tender
Civil Works - Buildings
Percentage
25 days
Kargil
Please refer Tender documents.
2 documents required · 2 mandatory
₹100
Xen RnB Division Kargil
₹12,300
6 Dec 2025
6 Dec 2025
16 Dec 2025
6 Dec 2025
15 Dec 2025
6 Dec 2025
Sub Head-1
Internal Electrification
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in Existing surface/recessed medium class PVC conduit ,with modular switch,modular plate,suitable GI Box and earthing the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required. (Make Havells/Polycab/KEI
Group A
Group B
Wiring for circuit/sub mains wiring along with earth wire of the following size of FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit as required.(Make Havells/Polycab/KEI)
2x2.5 sq.mm +1x2.5 sq.mm earth wire.
2x4 sq.mm + 1x4 sq.mm earth wire.
2x 10 sq.mm + 1x6 sq.mm earth wire.
2x 16 sq.mm + 1x6sq.mm earth wire .
Sub Head-2
Supply, installation,Testing & commissioning of Internal lighting fixtures
Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD < 10 % ,p.f.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted.
LED 12 W surface panel of lumen more than 1100 Round Shape.
10W LED Surface Ceiling mounted
Piller light outdoor
50 LED Flood light with ip 65 protection
Sub Heads-3
Supply,installation of E Fans,C Fans,E Fans
P/F of exhaust fan shutter type of sweep 250mm in the existing opening, including making the hole to suit the above fan, making good the damage as required.(Make: Havells USHA/Bajaj)
S/F of 1200mm sweep 3 blades,energy efficient 5 star ceiling fan complete with assembling of blades,down rod,shackle insulator,canopy etc,including 2 modular stepped type modular fan rugulator. (Make: Havells/Polycab/Orient/Khaitan)
Sub Heads-4
Gi Box along with modular base & Cover plates
S/F following size/module, GI box along with modular base and cover plate for modular switches/sockets in recess etc. as required: (Make: Havells Crabtree/Legrand/Greatwhite/CONA/Gold medel)
1or 2 module (75mm x 75mm)
3 module (100mm x 75mm)
4 module (125mm x 75mm)
6 module (200mm x 75mm)
8 module (225mm x 75mm)
Sub Head-5
Modular Switches and Sockets
S/F following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required. (Make: Havells Crabtree/Legrand/Greatwhite/CONA/Gold medel)
6 amp switch
16 amp switch.
3 pin, 6 amp socket outlet
6 pin, 16 amp socket outlet
Indicator lamp/Blank
Sub Head-6
MCCB & MCB Distribution Board
MCB Distribution Board: S/F Double door MCB distribution boards, 240V/415V, Sheet steel, Powder coated DB’s suitable for MCB’s fitted with Bus Bar, Neutral link, Earth Bar and Din bar of following no. of ways : (Make: Havells/C&S/L&T)
16 Way double door SP&N
12 Way double door SP&N
2 way single MCB Box
Sub Heads-7
Miniature Circuit Breaker/RCCB Residual Current Circuit Breaker/Double Pole Miniature Circuit Breaker
S/F of 5 Amps to 63 Amps, 240/415V, “B series, ISI Mark” miniature circuit breakers suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required: (Make: Havells/C&S/V Guard)
Single pole 6A, SP MCB
Single pole 16A, MCB
Mini MCB 4 Air Conditioner
Double pole 40A, DP MCB
Double pole 63A, DP MCB
100A ,4p changeover Switch
Sub Head-8
200A Busbar Chamber
Supply,carriage at site,installation testing and commissioning of following rating of BusBar Chamber (Wall mounted) in power coated sheet steel enclosure
SITC of 100A,4Way TPN Aluminum BusBar Chamber
Sub Head-9
Charcoal/Salted EARTHING
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Sub Head-10
Supply & Laying of Cable & End Termination
Supplying and laying following size and specification of XLPE insulated PVC sheathed armored cable with aluminum conductor for working voltage 1100 V grade as per IS: 7908, including thimble/lugs, double compression glands etc.of respective size. (Make: Havells/Polycab/KEI)
3.5C x 35 Sq.mm Armored Al. cable
Sub Head-11
Electrical Heavy PVC Conduit Pipe
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of MS fan box
Supplying and fixing of 10 x 10 x 10 cm of concealed box
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
BOQ_43825.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .