| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.1 LAccepted-AOC 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC Accepeted | |
| 2 | L2₹45.1 L+₹1.7 L (4.00%)Rejected-AOC KALATALAV TA ABDASA DIST KUTCH GUJARAT PIN 370 660 | KACHCHH | GUJARAT | 370660 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹45.5 L+₹2.1 L (4.92%)Rejected-AOC OPP RAM MANDIR NALIYA KUTCH 370655 | KACHCHH | GUJARAT | 370655 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹45.6 L+₹2.2 L (5.15%)Rejected-AOC 05 AYODHYA NAGAR NEAR RAM MANDIR BEHIND HARIYA COLLEGE GOKUL NAGAR JAMNAGAR 361004 | JAMNAGAR | JAMNAGAR | GUJARAT | 361004 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹45.8 L+₹2.5 L (5.74%)Rejected-AOC HOUSE NO 120 1 NEAR HANUMAN MANDIR AT POST SHEL PIMPALGAON TAL KHED DIST PUNE PIN 411014 | PUNE | MAHARASHTRA | 411014 | L5 | Rejected-AOC Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
7 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF NALIYA NO 1
GE AF STN Naliya Kutch 370655
PROVISION OF DEFICIENT WORK SERVICES AT WSA I AIRFORCE STATION NALIYA
2021_MES_440849_3
8745/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF NALIYA NO 1
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE AF NALIYA NO 1
₹80,000
Yes
24 Sept 2021
31 Jul 2021
9 Aug 2021
31 Jul 2021
7 Aug 2021
31 Jul 2021
60 days
Amount
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Demolition of Brickwork or stone / boulder masonry complete all as specified and as directed.
S&F grating 125mm dia with waste hole of PTMT(minium weight 40 gms) all as specified .
M&L for hand packing,broken stone or boulders (any thickness) at the back of walls over arch etc. and raising ( or lowering) to the required level complete all as specified and as directed.
M&L for formwork to faces of walls, retaining walls, abutment ,parapets and staircase railing and similar work including attachded pillasters, buttressess etc vertical or batter complete all as specified and as directed.
M&L for mild steel CRS bars 10mm dia and over cut to length,bent to shape required,including welding cranking,bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and as directed.
M&L for RCC M-30 [Design MiX] (20 mm Graded aggregate) for walls,retaining walls ,basement walls, ballast walls and the like any thicknes above top of footing, including attached pilasters and buttress complete all as specified and as directed.
M&L for 110 mm dia PVC (SWR) pipes single socketed ,in any length with rubber ring joints ,laid in trenches or in floors complete all as specified and as directed.
M&L for rendering 10 mm thick cement mortar 1:6 on brick / concrete surfaces, complete all as specified and as directed.
M&L for preparation of new plastered surfaces of walls surfaces and applying two coats of colour wash over one coat of white wash complete all as specified and as directed.
S&F for Nylon net of bird proofing for shed / storage accn / soft pen and possess following properties a) The burst strength up to 44 pounds b) Shall meet ISO 1806 protocols. c) 3/4 " (Three Fourth inch), Messs netting. d) Thickness 0.071" thick(6 Strands each 0.012" Thick). e) Quality control- filments: are twisted and knotted pressure stretched and tughtened. f) break strength: 52 lbs/2316 kgs per strand. g) Chemical properties-polythylene, a parffin hydrocarbon, is chemically insert, flame retardant and highly resistant to most chemicals at temperatures. h) High resistant to acids and alkaloids at all concentrations. i)High temperature-210-239°F / 100-115° (j) Low temperature-139 to 166°F, 95 to 110°C. Including all fitting such as rolling pully, Iron strips, rope for cotrolling net, nails etc. complete all as specified and as directed. Make: NETWEL / GARWARE / Make as approved by AO. Note:- The make will be as approved by Accepting Officer after checking above parameters from manufatures test certificates.
Removal of demolished building materials etc. (other than soil) to a distance of 500m or under, beyond the lead including in the rates ,including loading ,unloading and stacking at the destination complete all as specified and as directed. Note: One load shall mean one metric ton as specified in section 21 of SSR 2020
Material and labour for concealed conduit point wiring with ISI marked single core PVC insulated and unsheathed 1100 volts grade multi-stranded copper conductor FRLS cable of size 1.5 sqmm (nominal area) drawn through & including PVC conduit (ISI marked) not less than 20 mm dia concealed in wall, ceiling with GI saddles, GI screws, rawl plugs with all fittings including tees, junction boxes & including metal flush box and back plate of suitable size for mounting switches, sockets & regulators & drawing continuous earth wire of ISI PVC insulated unsheathed 1100 volts grade cable with copper solid conductor FRLS of size 1.5 sqmm (Nominal area) for One light point / fan point controlled by one, one way switch single pole modular type complete all as specified and as directed Note: Cost for cutting chases and making good to match the existing surface shall be deemed to be included in the quoted rate.
All as per Item No.13 here-in-before but for one 3 pin 5 Amp socket outlet on same board
All as per Item No.13 here-in-before but for one 3 pin 5 Amp socket outlet on independent board
All as per Item No.13 here-in-before but for , but with 2.5 sqmm multi-stranded copper conductor cable with 1.5 sqmm earth wire for one 6 pin socket outlet 5/15 Amps on didependent boared all as specified and as directed.
Supply and fix switch piano 5/6 Amps, single pole, one way, 230 volts complete all as specified and as directed.
Supply and fix switch socket out let, multi purpose, 3 pin, 5/6 amps, flush type, 230/volts complete all as specified and as directed.
Supply and fix switch socket out let, multi purpose, 6, 5/15 amps, flush type, 230/volts complete all as specified and as directed.
Supply and fix ceiling rose, surface, bakelite, 65 x 50mm, three terminals complete all as specified and all as directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 60x60cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5mtr below ground level connected to and including GI wire 4mm earth lead upto 7.5 mtr long by means of bolts, nuts, check nuts and washers etc with GI protection pipe of 40mm bore medium grade and connected to earthing test point all as shown in electrical plate No 3 of SSR part-I and as specified or indicated including excavation & eartwork in any type of soil, PCC (1:3:6) chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with 6mm dia MS rods at 150mm c/c both way), with frame, funnel with 20mm bore Gi pipe medium grade watering pipe, wire mesh and lugs test point etc and testing on completion complete all as specified and as directed.
S & F slim Led tube light and batten of wattage not less than 20 watt, 2000 Lumen (4 feet long) white/ brown colour, fixed to wall / ceiling along with nrcessary fixing screws, etc, complete all as specified and as directed.
Supply & fix ceiling fan 230 volts single phase of 1200 mm sweep complete all as specified and as directed.
S & F stepped type electronic fan regulator, flush type complete all as specified and as directed.
S & F MCB DB SPN 240 volts 4 way IP 42 protection double door rated busbar complete all as specified and as directed.
S & F MCB SP of 240 volts, 5.30 Amps capacity "C" series complete all as specified and as directed.
S & F MCB SP of 240 volts, 40 Amps capacity "C" series complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in any type of soil, for under ground electic cable, pipes etc, complete all as specified and as directed. Note : Authorised width & depth shall only be excavated, measured and paid as specified in clause 3.2.3 of SSR part-II and SSR part-I
Returning, filing-in, including, spreading, watering and well ramming in layers not exceeding 25cm thick each in any type of soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply and laying galvanised steel water tubing, light grade, IS -1239 marked with all fittings IS marked and laid in trenches under roads, through drains, fixed to poles/walls with required size flat iron clamp bolts, nuts and washers, for cable protection of 100 mm dia, including taking out old / existing pipes, complete all as specified and as directed.
M&L for sand cushioning/filling in trenches for cable cushioning complete with dry river sand of good quality complete all as specified and as directed. Note: Depth after punning ie 18cm only shall be measured and paid as speicified in SSR.
Supplying & laying un-reinforced percast concrete cable cover class LV, Type 2, with peak, size 300mm x 180 mm x 40 mm confirming to IS 5820 (M20 grade concrete) each other with gap between adjacent slab not exceeding 10mm over under ground cable for protection all as specified and directed.
Supply, laying and testing ISI marked XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sq mm 4.0 core complete all as specified and as directed.
Supply and fix Reverse Osmosis plant of out put capacity of 1000 liters per hour including water feeding pump from raw water tank, clorination arrangement, softeners, plumbing and electrical wks for connectIon of RO complete including commissioning and testing complete all as specified and as directed. Note: Feed water characteristics: Turbidity <500ppm, IRON <0.3 ppm, ph range 6.5-7.2, total hardness<500ppm, TDS<1500 ppm.
S & F raw water and RO water storage ISI marked PVC tank double layered of capacity 5000 ltrs complete all as specified and as directed.
Supply and laid in trenches 40mm bore galvanized iron steel water tubing, medium grade including necessary fittings such as GI bends, tees, Union etc, complete and connecting to water supply pipe lie including taking out existing old/rusted out steel tubing and connecitons complete all as specified and as directed. Note : Excavation, returning filling and removing of soil shall be measured and paid separately under relevant items of this schedule.
M & L fix in repair Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed after taking out old/rusted off of the size 40mm bore complete all as specified and as directed.
S&F 1 HP horizontal submersible pump with starter for RO water feeding to OH tanks complete all as specified and as directed.
M&L for Plain Cement Concrete 1:4:8 type D2 (using 40mm graded stone aggregate) for foundation of storage tank complete all as specified and as directed.
M & L for Plain Cement Concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in pedestal of pole/strut/foundation for storage tank and in coping including use and waste of necessary form work and finishing exposed faces of concrete finished even and smooth with using extra cement complete all as specified and as directed.
M & L for earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connected to copper earth strip of 20 x 3 mm (up to 7.5m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanised iron or steel all as specified and shown in electrical plate No 3 of SSR part-1 including Charcoal, Rock salt, necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 6mm dia 150mm c/c reinforcement, watering funnel 32 mm dia light grade for protection of earth electrode 20 mm dia for watering all as specified and directed and tested on completion. Note: The unit rate quoted shall deemed to have included for GI protection pipe, copper earth strip up to 7.5 mtr, GI water pipe, wire mesh, funnel, excavation, RCC pit cover complete all as specified.
Hari Construction
M/s. Shree Shakti Enterprise
KEVAL ENTERPRISE
NILESH SUBHASH KARALE
Venus Engineering
THOMAS M. MATTACKAL
nidhi construction co.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .