Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
23 Sept 2020, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM P and P
Projects and planning Cochin Division FACT ltd
P4 Motor Cable Rerouting Work Related to New Phosphoric Acid Storage Tank Construction at WI
2020_FACT_580327_1
4085/2020-2021/E22013
Limited
Miscellaneous Services
Item Rate
45 days
Ambalamedu
Limited tender from FACT approved vendor list CDE109A
5 documents required · 5 mandatory
₹0
₹12,000
Yes
24 Sept 2020
1 Sept 2020
24 Sept 2020
1 Sept 2020
23 Sept 2020
1 Sept 2020
120 days
P4 Motor Cable Rerouting Work Related to New Phosphoric Acid Storage Tank Construction at WI
Supply of mterials for ladder type cable tray upto 300mm wide, including supports using ISA 50X50X5/6, ISMC 100X50, 25X5/6 flat etc at various locations in Q10 berth installations of FACT.
Fabrication, painting, unloading and erection of ladder type cable tray upto 300mm wide, including supports using ISA 50X50X5/6, ISMC 100X50, 25X5/6 flat etc at various locations in Q10 berth installations of FACT. The erection scope shall include handling of materials at site, storage, inspection, safe custody, welding, cutting, making bolt holes, painting with two coats of epoxy paint over two coats of suitable epoxy primer after cleaning with wire brush including supply of paint, wire brush etc.The supplied epoxy paint shall be of Berger/Asian Paints/ Nerolac or equivalent. Supply scope includes MS structural items, welding rods, LPG/Oxygen cylinders, bolts, nuts, washers, cement, sand, etc. The bolts, nuts, washers shall be of GI. The erection scope includes dismantling of existing corroded cable trays, installation of new cable tray on existing/ fabricated supports.The fabricated cable tray supports shall be welded to the MS structurals or fixed onto walls of conveyors. The contractor shall supply and fix sufficient anchor bolts of size not less than 12x100 mm at an interval of 1 meter for fixing the cable tray/ support if MS structurals are not present. The work shall be carried out as per the instructions of the Electrical Engineer-in-charge. The erection scope also includes fixing of existing cable trays to the newly fabricated supports. The supplied items shall be unloaded at suitable location in the Willingdon installation of FACT as per the directions of Engineer-in-charge. Payment shall be made on the basis of measurement of dimensions of structural steel items actually installed multiplied by the unit weight applicable for various sections.
Supply and unloading of of 650/1100V, Aluminium conductor PVC/XLPE insulated, armoured, FRLS PVC outer sheathed 3c x 185 sq.mm cable. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge.
Erection/installation, testing, commissioning and handing over of 650/1100V, Aluminium conductor PVC/XLPE insulated, armoured, FRLS PVC outer sheathed 3c x 185 sq.mm cable. The scope of work shall also include laying, dressing, fixing on cable trays /racks /risers /walls /columns /pipes, clamping, tagging, tying, drilling holes, minor civil work, testing, commissioning, etc. The rates quoted shall include supply of all accessories required such as, cable clamps, bolts, nuts, washers, cable tags, nylon ropes, etc.
Supply of 650 Volt grade, PVC Insulated, unarmoured 1 c X 70 sq.mm Aluminium Cable as per IS 694, with latest amendments and with ISI marking & cable length to be marked on every 5 Meters on the outer Sheath of the Cable. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge
Laying and erection of 650 Volt grade, PVC Insulated, unarmoured 1 c X 70 sq.mm Aluminium Cable as per IS 694, with latest amendments and with ISI marking & cable length to be marked on every 5 Meters on the outer Sheath of the Cable . The erection scope shall include laying, dressing, fixing on cable trays /racks /risers /walls /columns /pipes, clamping/tying neatly with GI/Aluminium saddles/ nylon rope on wall/cable tray etc in a uniform spacing of 500mm, tagging, tying,drilling holes, minor civil work etc. The rates quoted shall include supply of all accessories required such as GI/Aluminium saddles, cable clamps, bolts, nuts, washers, cable tags, nylon ropes, etc.
Supply and unloading of 650/1100V, annealed copper stranded conductor, PVC/XLPE insulated, strip/wire armoured, FRLS PVC outer sheathed , 19c x 2.5 sq.mm control cable conforming to IS 1554. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge.
Laying, erection, installation testing, commissioning and handing over of 650/1100V, annealed copper stranded conductor, PVC/XLPE insulated, strip/wire armoured, FRLS PVC outer sheathed , 19c x 2.5 sq.mm control cable conforming to IS 1554. The scope of work shall also include laying, dressing, fixing on cable trays /racks /risers /walls /columns /pipes, clamping, tagging, tying, drilling holes, minor civil work, testing, commissioning, etc. The rates quoted shall include supply of all accessories required such as, cable clamps,bolts, nuts, washers, cable tags, nylon ropes, etc.
Supply of single compression Nickel plated brass cable glands suitable for 650/1100V, Aluminium conductor PVC/ XLPE insulated, armoured, FRLS PVC outer sheathed 3c x 185 sq.mm cable. The bidder shall verify the entry thread, type of enclosure etc, to find out the actual type of gland required.
Installation of single compression Nickel plated brass cable glands suitable for 650/1100V, Aluminium conductor PVC/ XLPE insulated, armoured, FRLS PVC outer sheathed 3c x 185 sq.mm cable. The bidder shall verify the entry thread, type of enclosure etc, to find out the actual type of gland required.
Supply of single compression Nickel plated brass cable glands suitable for 650/1100V, Aluminium conductor PVC/ XLPE insulated, armoured, FRLS PVC outer sheathed 19c x 2.5 sq.mm cable. The bidder shall verify the entry thread, type of enclosure etc, to find out the actual type of gland required
Installation of single compression Nickel plated brass cable glands suitable for 650/1100V, Aluminium conductor PVC/ XLPE insulated, armoured, FRLS PVC outer sheathed 19c x 2.5 sq.mm cable. The bidder shall verify the entry thread, type of enclosure etc, to find out the actual type of gland required.
DAMODARAN V
stage.html
html • 0.02 MB
finance_609484.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .