Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC | ₹29.4 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹30.0 L+₹62,869.95 (2.14%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | ₹30.0 L+₹62,869.95 (2.14%) | L2 | Rejected-Finance Being not L1 |
| 3 | L3₹30.6 L+₹1.2 L (4.20%)Rejected-Finance D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | ₹30.6 L+₹1.2 L (4.20%) | L3 | Rejected-Finance Being not L1 |
| 4 | L4₹31.6 L+₹2.2 L (7.50%)Rejected-Finance 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | ₹31.6 L+₹2.2 L (7.50%) | L4 | Rejected-Finance Being not L1 |
| 5 | L5₹32.9 L+₹3.5 L (12.1%)Rejected-Finance | ₹32.9 L+₹3.5 L (12.1%) | L5 | Rejected-Finance Being not L1 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
19 Nov 2020, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR/MAINT OF HT VCB PANEL INCLUDING CALIBRATION OF RELAYS AND REPAIR/MAINT OF STREET LIGHT/SECURITY LIGHTS, HIGH MAST , LT PANELS, UG CABLES ETC INCL CERTAIN MISC WORK AT INHS KALYANI UNDER AGE E/M NO- I OF GE (U-I) VISAKHAPATNAM
2020_MES_380661_2
8230/E8
Open Tender
Manpower Supply
Item Rate
330 days
Garrison Engineer Utility-I Visakhapatnam
CLASS D
10 documents required · 10 mandatory
₹500
Garrison Engineer Utility-I
₹99,000
Yes
7 Dec 2020
31 Oct 2020
21 Nov 2020
31 Oct 2020
19 Nov 2020
7 Nov 2020
Amount
Decarburizing/cleaning complete LT 415 Volts 3 phase panel/ bus bar chamber with electrical connections, complete bus bar from the bus bar chamber, cleaning with CTC and ensure proper decarburizing, refixing the same after applying Backtol Red solution to the bus bar insulator & checking all the connections, tightening the nuts, bolts & thimbles of in-coming/out-going system complete incl replacement of defective rusted bolts & nuts all as specified and directed.
Supply and fixing indication lamp, 230 volts AC, LED type colour of RYB complete all as directed. Make :- KAYCEE / TECHNIK / L & T
Supply and replace MCCB 4 pole, 415 V, adjustable type 400 Amps with breaking capacity 35 KA as required at site and as per existing model including necessary modification in the panel with proper lugs complete all as specified and as directed. Make: L&T/Seimens/Schneider/Legrand
Supply and replace MCCB 3 pole, 415 V, adjustable type 250 Amps with breaking capacity 25 KA as required at site and as per existing model including necessary modification in the panel with proper lugs complete all as specified and as directed. Make: L&T/Seimens/Schneider/Legrand
Supply and replace MCCB 3 pole, 415 V, adjustable type 200 Amps with breaking capacity 25 KA as required at site and as per existing model including necessary modification in the panel with proper lugs complete all as specified and as directed. Make: L&T/Seimens/Schneider/Legrand
Supply and replace MCCB 3 pole, 415 V, fixed type upto 63 to 100 Amps with breaking capacity 25 KA as per the requirment of site and as per existing model including necessary modification in the panel with proper lugs complete all as specified and as directed. Make: L&T/Seimens/Schneider/Legrand
M&L for removing the cable connections of four pole/ three pole Air circuit breaker of capacity 630 to 1000 Amps ,415 V 50 HZ of Make: L&T/C&S/GE/ABB/SIEMENS/SCHENEIDER, Strip opening the Air circuit breaker, inspecting the parts for serviceability/overhauling complete and carrying out the following repairs/maintenance :-
a) Cleaning the insulation parts including bushings with CTC solution.
b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manual
c) Check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. Replace the worn-out parts.
d) Check arc chutes for damage and replace damaged parts.
e) Clean and lubricate the operating mechanism with a light machine oil (SAE-20 or 30) for pins and bearings and with a non-hardening grease for the wearing surfaces . Adjust breaker operating mechanism all as per manufacturer's instructional manual . Replace if there is excessive wear and tear.
f) Checking / inspecting shunt trip coil for serviceability and replacing the same if required.
g) Replacing the badly worn or burned contacts. Checking control device free for operation.
h) Check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional
Note : (i) The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts/bolts/washers/ pins etc. (ii) Major spares like contacts, shunt trip coil , relays, CTs etc will be measured & paid separately as supply only under relevant items.
Supply only cluster contact suitable for air circuit breakers of rating 800 to 1000 Amps all as per existing model of Make: L&T / C&S / GE / ABB / SIEMENS / SCHENEIDER and as directed by Engineer-in -charge.
Supply only trip coil suitable for air circuit breakers of rating 800 to 1000 Amps all as per existing model of Make: L&T / C&S / GE / ABB / SIEMENS / SCHENEIDER and as directed by Engineer-in -charge.
Supply only auxiliary contact block suitable for air circuit breakers of rating 800 to 1000 Amps all as per existing model of Make: L&T / C&S / GE / ABB / SIEMENS / SCHENEIDER and as directed by Engineer-in -charge.
Supply only arc chutes (for 415 V) suitable for air circuit breakers of rating 800 to 1000 Amps all as per existing model of Make: L&T / C&S / GE / ABB / SIEMENS / SCHENEIDER and as directed by Engineer-in -charge.
Supply only rating plug suitable for air circuit breakers of rating 800 to 1000 Amps all as per existing model of Make: L&T / C&S / GE / ABB / SIEMENS / SCHENEIDER and as directed by Engineer-in -charge.
Supply only shunt release (110 /220 V DC or 240 V/415 V AC) suitable for air circuit breakers of rating 800 to 1000 Amps all as per existing model of Make: L&T / C&S / GE / ABB / SIEMENS / SCHENEIDER and as directed by Engineer-in -charge.
Supply only arcing contacts (fixed/ moving) suitable for air circuit breakers of rating 800 to 1000 Amps all as per existing model of Make: L&T / C&S / GE / ABB / SIEMENS / SCHENEIDER and as directed by Engineer-in -charge.
Supply & Fix street light luminaire integral type high power LED fitting of 90 watts out put with minimum 60 lumens per watt in aluminium die cast housing with IP 66 protection complete with all accessories including driver and electronic surge protection device of 5 KV complete including taking out old one all as specified. ( MAKE: M/s Philips Model No. BRP410 LED 091 CW HE MR PC S2 PSU GR or equivalent in CG/Havells/Jaquar/Wipro as approved by GE )
Taking out the Loop in loop junction box , disconnet the cable connections and refixing the loop in loop box with cable connections with provision of new set of aluminium Lugs / thimbles of size 10 sqmm/ 16sqmm /25sqmm / 35 sqmm for 3.5 / 4.0 core existing LT cables of any type including provision of necessary tape insulation, clamps for fixing of cables ,fittings and fixtures, nut bolts, clamps etc complete all as specefied and directed.
Supply fixing and testing of Flood light die cast aluminium of 200 W, 230 volts (maintaing minmum system lumen-20000) with IP 66 including inbuilt driver with all fixing arrangements with nuts & bolts,clamps, iron chanels on poles etc including taking out old one complete all as specified and directed. ( MAKE: M/s Havells Model No. JETAIRISPLUSFLS200WLED757PSYMLTG or equivalent in CG/Philips/Jaquar/Wipro as approved by GE )
Supply fixing and testing of Flood light die cast aluminium of 200 W, 230 volts(maintaing minmum system lumen-20000) die cast luminium with IP 66 including with separate control drive for high mast / high rise application etc with all fixing arrangements with nuts & bolts, clamps, iron chanels, with cables to poles etc including taking out old one complete all as specified and directed by Engineer-in-Charge. Make: Cat No.JETAVALOURFL200WLED757MODSYMLTG of Havells or its equivalent in Philips//WIPRO.
Preparation of external surfaces of LT panels indoor/outdoor type for painting by scraping down old paint by steel brush broomming rubbing and cleaning and applying two coats of synthetic enamel paint as approved and marking good complete all as specified and directed.
Taking down defective street light fitting of any size /any type/ any capacity from pole/ walls/ high rise at any location of height 09 mtr / 11 mtr from ground level for reapir work and fixing back after repair work including checking, inspecting, testing and commissioning complete all as directed by Engr-in-Charge. Note : (a) Spares like ballast, lamp, starter, capacitor , igniter, holders, lamp holder, etc. shall be measured and paid separetely under relavant items of schedule'A' (b) Necessary tools like mobile ladder & other T&P required etc shall be arranged by the contractor (c) The rate quoted deemed to be inclusive for minor repair parts like nuts, bolts,cirle clips, clamps etc if required at site.
Supply the following spares for street light fittings of any type, any model as per existing parts as per site requirement (make : Phillips/ crompton Greaves / Havells / GE )
Lamp holder for garden lights / land scape /Gate lights of any type /any size / any model as per site
Ballast HPSV/MH 400 W
Ballast HPSV/MH 250 W
Electornic Igniter for HPSV/MH Lamps 70/150/250/400W
Lamp MH 400 W with theard
Lamp MH 250 W with theard
Supplying,fixing and testing of Street lights LED 90 Watt with drive, 230 volts or nearest size pressure die cast aluminium housing luminaires with high power LED source (maintaing minmum system lumen-6000) on 09 m/11m poles with IP protection 66 all necessary fixing arrangments and fittings etc including taking out old one of any type complete all as specefied and directed. (Make: CG Model: LST-90-CDL-M or Havells Model : ENDURACITYLINERNEOSL90WLED757SASYBOTG or equivalent in Philips/Jaquar/Wipro as approved by GE )
Supplying,fixing and testing of Flood light die cast aluminium of 150w, 230 volts or nearest size (maintaing minmum system lumen-15000) with IP 66 including drive with all fixing arrangements with nuts&bolts,clamps, iron chanels on poles etc complete all as specified and directed by Engineer-in-Charge including taking out old one (Make: Havells Model : JETAIRISFLS150WLED757PSYMLTG or equivalent in CG/Philips/Jaquar/Wipro as approved by GE )
Supplying, fixing and testing of Gate light / post-top light fitting 35W / 40W LED or nearest size (maintaing minmum system lumen-3500) with die cast aluminium body with drive, 230 volts or nearest size and with spun aluminium landscape luminaire and IP-65 protection with high power LED as source all necessary fixing arrangments and fittings etc including taking out old one of any type complete all as specefied and directed. (Make: Havells Model: CORALPT35WLED757PSYMTOPC or equivalent in CG/Philips/Jaquar/Wipro as approved by GE )
M&L for preperation of old painted surface, cleaninig of oils, lubricants, grease etc complete of any type of 11.0 mtr long poles as per IS above PCC coping with applying 2 coats of aluminium paint including brackets, clamps and terminal boxes including 5 cm wide two nos red colour flourcent strip pasting on pole as directed and writing pole Nos all as specefied and directed.
Excavation in trenches n.exc 1.5 m wide and not exc 1.5 m depth and getting out in soft/loose soil complete all as specified and directed.
Removal of surplus excavated material of any type to a distance not exceeding 50 m and depositing where directed at a level not exc. 1.5 m bove the starting point complete all as specified and directed.
Returning and filling in of excavated material any type including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed.
Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed. (Note: Punned thickness only shall be measured)
Supply and laying sub class 'B' bricks of old size (approved size locally available) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Supplying, laying, testing and commissioning LT XLPE insulated , armoured heavy duty electric cable of size 4 core 16 sq mm , 1100 volts grade with stranded aluminium conductor laid in trenches / passing through pipe / duct/ road crossing /fixed on poles / walls complete all as specified and directed. MAKE: Havells / Gloster / KEI Industries Ltd / Polycab / Asian Cables / Finolex [Note: The rate quoted shall inclusive of termination at ends with suitable aluminium lugs where required]
All as per item No.33 here-in- before but of 3.5 core 35 Sq mm
All as per item No.33 here-in- before but of 3.5 core 50 Sq mm
All as per item No.33 here-in- before but of 3.5 core 95 Sq mm
All as per item No.33 here-in- before but of 3.5 core 120 Sq mm
All as per item No.33 here-in- before but of 3.5 core 240 Sq mm
All as per item No.33 here-in- before but of 3.5 core 300 Sq mm
Supply and fix hot press moulded junction boxes with hinged door, fitted with 4 P ,50Amps rated connector and neutral link mounted in the box,including necessary fixing arangement to the steel tubular pole/over walls including taking out old one complete all as directed. Make: Sintex /Hansel Controls .
Supply and fix PVC insulated and FR PVC round sheathed, copper conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694 of size 1.5 sqmm 3 core cable to connect from street light fitting to loop-in and loop out box with its end point terminal connection complete all as specified & directed. MAKE : Polycab /CG / Philips / Havells
Supplying , fixing and testing of timer switch 65A 3 pole panel complete for street light controls analog time switch with connected items fixing on pole/wall/panels including PCC with all fixing arrangements complete including taking out old one etc all as directed of Make: Havells or its equalent in L&T / Siemens /Hager / Schneider.
Supply and replacement of multi core PVC insulated stranded copper conductor of size 25 sqmm 4 core cable to be connected with street light fittings to loop-in and out boxes with its end point terminal connection complete all as specified & directed. MAKE : Polycab /CG / Philips / Havells
Material and labour for maintenance to 320 KVA Gen Set for 'B' check after 06 months or 250 hrs running, whichever is earlier as per the recommendations of manufacturer including renewing of necessary filters, Engine oil etc, complete all as per manufacturers instructional manual and all as directed by Engg-in-charge. (Note : Engine oil will not be suplied under Sch 'B' for carrying out 'B' check.The quoted rate deemed to be included for the same.)
All as per item No. 38 above but for 250 KVA DG Set
All as per item No. 38 above but for 200 KVA DG Set
All as per item No. 38 above but for 140 KVA DG Set
All as per item No. 38 above but for 100 KVA DG Set
All as per item No. 38 above but for 62.5 KVA DG Set
M & L for repairing & servicing of self starter including replacement of commutator, carbon brush set with holder, king pin holder, armature, check nut body scrws, clutch plate assembly and solenoide etc., for DG set capacity 320 KVA DG Set.
All as per item No. 39 here in above but for DG set of 250 KVA capacity
All as per item No. 39 here in above but for DG set of 100/140 KVA capacity
M & L repair and servicing of charging alternator including replacement of diode set with holders, bushes, bearing, varnishing, reassembling etc for 320 KVA DG Set.
All as per item No. 40 here in above but for DG set of 250 KVA capacity
All as per item No. 40 here in above but for DG set of 100/140 KVA capacity
Disconnecing/ Removing existing U/S Battery 12 V 180 AH from the DG set and supply, fix maintenance free battery of 12 Volts 180 AH capacity with 2 years warranty including replacement of battery terminal clamp and testing and commissioning all as directed. Make: EXIDE/AMCO/AMRON
Disconnecing/ Removing existing U/S Battery 12 V 90 AH from the DG set and supply, fix maintenance free battery of 12 Volts 90 AH capacity with 2 years warranty including replacement of battery terminal clamp and testing and commissioning all as directed. Make: EXIDE/AMCO/AMRON
Material and labour for topping of Engine oil of grade 20 W 40 in DG sets all as directed and specified by Engr-In-Charge. Make : SERVO / VEEDOL
Material and labour for replacement of air cleaner and Deisel filter of 320 KVA Gen Set matching with existing one as recommended by OEM and all as directed by Engg-in-charge.
All as per item No. 44 above but for 250 KVA DG Set
All as per item No. 44 above but for 200 KVA DG Set
All as per item No. 44 above but for 140 KVA DG Set
All as per item No. 44 above but for 100 KVA DG Set
All as per item No. 44 above but for 62.5 KVA DG Set
Supply, calibrating, installing, setting, testing, commissioning of AVR panel for 62.5 - 320 KVA DG set, 415V, 3 phase, 4 wire system, Digital type, Voltage regulation: 10% of rated voltage, frequancy setting: 50/60 cycle, stebility, doom settings, exitation voltage, currect to be matched with OEM instructions i.e of Make Jyothi and equivalent complete all as directed.
Supply, replacing, testing & calibrating and commissioning of engine oil pressure gauge, dial type, Analog type, range 0 to 10 kg/cm², resolution 0.25kg/cm², control wiring complete all as directed
Supply, replacing, testing & calibrating and commissioning of coolant temperature gauge, dial type/ Analog type, range 0 to 150 C°, resolution 5C°, control wiring complete all as directed
Supply, replacing, testing & calibrating and commissitoning of ammeter, dial type/Analog type, range -150 - +150 Amps, resolution 10Amps, control wiring complete all as directed
Supply, replacing,testing & calibrating and commissitoning of hour run meter cum tacho meter,dial type,Analog type,range 0 - 3600 RPM,reselution 50 RPM,control spring cable including inner and outer complete all as directed
M&L for De-scaling of radiator by dismantling the upper & lower tank and cleaning the core pipes with cleaning chemicals, components and arrest the leaking core by brazing/ dummy with lead including cleaning of upper and lower tanks and replacing the upper and lower gaskets and required nuts, bolts, refixing the same including testing and painting complete all as specified and as directed for the following capacities
(a) 63 to 320 KVA
M&L for repair of Diesel Engine by dismantling the Sub-assemblies such as fuel pump, fuel injection, wood ward Governor, turbo-charger, radiator, oil cooler, engine heads, rocker arms, self starter, dynamo-engine wiring, terminal contacts and safety controls etc. including replacement of spare parts as required and re-assembling the sub-assemblies after carrying out necessary repairs including testing and commissioning complete all as directed by Engineer-in-charge for the following capacity. Notes: 1. Supply only Spare Parts required shall be measured and paid separately under relevant items of Schedule 'A' 2. Repairs and calibration of Sub-assemblies shall be measured and paid separately under relevant items of Schedule 'A'
(a) 125 KVA TO 320 KVA DG set
Removing old earth and M & L for earthing complete with GI earth plate electrode of size 600mm x600mmx 6.0 mm thick burried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5 m below ground level connected to and including GI strip 32 x 6mm, by means of bolts, nuts, check nuts and washeres made out of GI including protection pipe GI light grade 40 mm size and watering pipe 20 mm dia GI medium grade all as shown on plate No 3 of SSR Part-I, connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed.
S&F synthetic insulation mat suitable for upto 12 KV electric purpose of size 2m x 1m x19mm complete
M&L for strip opening AMF panel of 100/63 KVA DG set, checking, inspecting, calibrating AMF panel & replacement of defective AMF relay matching with existing,replacing the burnt copper wiring with suitable flexible copper wire, inspecting the contactor coils & replacing the defective coils, cleaning the fixed/moving contacts with CTS complete including setting of AVR of Alternator complete including testing & commissioning complete.
M&L for strip opening AMF panel of 250/200 KVA DG set checking, inspecting, calibrating AMF panel & replacement of defective AMF relay matching with existing , replacing the burnt copper wiring with suitable flexible copper wire , inspecting the contactor coils & replacing the defective coils, cleaning the fixed / moving contacts with CTS complete including setting of AVR of Alternator complete including testing & commissioning complete.
Supply and fixing ON LOAD changerover switch front operated four pole 630 Amps complete all as directed . Make L&T/Legrand / Havells
Supply and Replace Off Load Changeover including sheet metal encloser with side handle 400 Amps 4 pole 240 Vcomplete all as directed . Make L&T/Legrand / Havells
M&L Earthing Electrode 300 mm length copper coated, 100 microns thickness as per UL standard approved and testing by CPRI, pipe in pipe type inner pipe dia 41.9(min)mm, outer dia 76/80(min)mm annular space filled with high conductivity and anti corrosive compound with connection terminal. M&L infill compound (Chemical) 50Kgs ( 2 Bag each 25 Kgs) Elecrodite/ Humedites constituting natural element not water dissoble reduce soil resistivity highly hygroscopic and swells high conuctivity and anti corrosive retains moisture for a long time . M&L Earth work Vertical excavation in normal soil upto a depth of 3000mm the diameter of the bore hole being minimum 250 mm . installation filling the bottom 4" of the bore with infill compound (Chemical) vertically placing the electrode in the centre of the pit ,fill the cavity around the electrode with the chemical ensuring there are no air gaps in the chemical filled cavity region make a thick paste by pouring water into the earth pit and mixing the mixture with a pole. complete as directed. including PCC earth Pit and RCC Pit cover complete
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as 32x6mm copper strip complete all as directed.
Dismantling the spring charging mechanism of the VCB, checking the entire mechanism for any worn/ crack/ bent/ block/ loose parts etc. for the following:-
(i) Checking the condition of the spring charging motor along with gear box including servicing the motor & replacement of motor bearings if required.
(ii) Checking/ servicing of ratchet wheel assembly, driving and charging parts.
(iii) Checking the auxiliary switch, its contacts for proper functional operation.
(iv) Checking & servicing of raising/ lowering mechanism and its locking system for proper functioning.
(v) Checking & servicing of shutter assembly for its automatic opening/ closing.
The items like nuts, bolts, spring washers, petroleum jelly, CTC etc required to put the breaker in serviceable condition shall be supplied by the contractor and rate shall be deemed to be included in the unit rate quoted.
M&L for de-carbonising/ cleaning of 11KV cubicle type VCB panels consisting of bus bar and circuit chamber, metering chamber, CTs, PTs and relay chamber all as specified below:-
(i) Checking the bus bar and circuit spouts, cleaning with CTC and applying bectrol red varnish to the surface of the bus bar and circuit spouts.
(ii) Checking the CTs/ PTs for any arcing/ tracks, cleaning and applying one coat of varnish.
(iii) Cleaning of metering and relay chamber, checking/ replacement of burnt wires if any, tightening of all connections to arrest the loose contacts.
(iv) Applying mono-plast compound at bus bar joints after tightening all joints/ connections.
M&L for disconnecting carefully electrical connection from both HT/ LT (primary & secondary) sides of the transformer, keeping them at safe side the transformer indoor/ outdoor type of capacity from 63 KVA to 1000 KVA , 11 KV/ 0.433 KV, step down any make for carrying out refixing after completion of minor repairs like maintenance / replacement of HT/LT bush, metal rods, lugs, replacement of rusted nutbolts etc incl cheking the continuty of HT/LT windings , top cover opening, prevent the all oil leakages, provn of new insulated gaskets / cork sheet for HT/LT supply etc complete all as specefied and directed. Note: porcelain bushings, gun metal rods, cable end joint kit, transformer oil etc to be measured and paid separatly under respective schedules.
Manning and Operation of main receiving station (MRS) INHS Kalyani to the equipments installed/HT yards and DG sets in 3 shifts of 08 hours round the clock in all days including sunday and holidays each all as per the details given below:
(i) One skilled electrician in each shift Note : (i) Bidder has to quote the following mandatory provisions related to wages and misc benefits for workmen which includes all Taxes, cess, levis as applicable including GST. (ii) In case the rates quoted are less than the prevailing rates / instructions under any heading(s), the bid will be treated as non-bonafide / invalid which shall be disqualified and such bids will not be considered for acceptance (iii) Payment for item nos. 68.00 (i) (a) to (f) will be done after submission of valid & authentic documents in support of proof of payment as mentioned in tender documents.
(a) Wage.
(b) Employer's Contribution towards Employees Provident Fund (EPF) .
(c) Employer's Contribution towards Employees State Insurance Corporation (ESIC ).
(d) Bonus in terms of "The Code on Wages-2019"
(e) Labour Welfare Cess (LWC) on Sl item no. 68.00 (i) (a) to (d) .
(f) Overhead and profit on Sl item no. 68.00 (i) (a) to (e) . [Quotations with ‘Nil’ or ‘Zero’ consideration (overhead and profit) shall be considered as “non bonafide bid”].
(ii) One semi skilled electrician in each shift Note : (i) Bidder has to quote the following mandatory provisions related to wages and misc benefits for workmen which includes all Taxes, cess, levis as applicable including GST. (ii) In case the rates quoted are less than the prevailing rates / instructions under any heading(s), the bid will be treated as non-bonafide / invalid which shall be disqualified and such bids will not be considered for acceptance (iii) Payment for item nos. 68.00 (ii) (a) to (f) will be done after submission of valid & authentic documents in support of proof of payment as mentioned in tender documents.
(a) Wage.
(b) Employer's Contribution towards Employees Provident Fund (EPF) .
(c) Employer's Contribution towards Employees State Insurance Corporation (ESIC ).
(d) Bonus in terms of "The Code on Wages-2019"
(e) Labour Welfare Cess (LWC) on Sl item no. 68.00 (ii) (a) to (d) .
(f) Overhead and profit on Sl item no. 68.00 (ii) (a) to (e) . [Quotations with ‘Nil’ or ‘Zero’ consideration (overhead and profit) shall be considered as “non bonafide bid”].
NOTE : The rate shall also include the following: (i) The staff shall attend to HT/LT fuse off calls minor repairs to HT/LT panels, cables connections, terminations, items at INHS Kalyani complex, Nivedita Bldg and LT lines to DCS block , DG sets of capacity 250KVA, 180KVA, 140KVA 100 KVA and 200KVA , as directed by Engr-in-charge.
(ii) HT/LT complaints should be attended within 15 min and rectification / further reporting of major complaints shall be intimated to Engineer-in-Charge and JE concerned.
(iii) The contractor has to supply all requisite tools and all HT/LT electric safety equipments and uniform to their employees for wearing during the working hours. The pattern of the uniform shall be as decided by GE.
(iv) Maintaining general cleaning, removing of vegetation around installation such as transformer yard around the panel etc. (v) (a) HSD oil required for running DG Set will be issued under Schedule ‘B’ free for filling which will be made available at site by Department. (b) It is the contractor’s responsibility to maintain the minimum reserve of oil in tank at any time and as directed by EIC. (c) Necessary Men power required to load the HSD oil at Store yard and to unload the HSD Oil at site shall be arranged by contractor and the rate quoted shall include for the same.
Supply & replacement, calibrating, testing, commissioning of Micro processor feeder protection relay, range - 0.01In – 8In, protection setting- 2 set, protecting circuit correct – 1Amps & 5Amps sets, records history- 5Nos, Min 6 Analog out put, with following protections feeder protection 50/ 51N (3 Phase current), 50/ 51N (Earth Over current), 67 P (3 Phase directional Over current), 6/N (Earth fault directional over current), 51V (Voltage controlled over current) 37 (3 phase under current), 46(Negative phase sequence over current), 59N (Residual over voltage), 49 (Thermal over load), 79(Auto reclose), 50BF( Circuit breaker failure detection), Cold Load pickup, Inrush blocking, Relay will be on MODBUS protocol with LCD display, trip, circuit healthy, alarm, other assignable indication,Auxlary suppy : 110V DC complete all as directed.
Supply of CT's epoxy cast resin , with primary Current 100A - 50A / 1 A - 1A , Secondary current 1A , Dual core , Dual Ratio. Protection core -Class 5P10 & Metering core - Class 0.5 , 2.5 VA . Suitable for SIEMENS make RMU.
Dismantling of existing CT's , Installation of supplied CT's in SIEMENS make RMU & Commissioning by checking of current transformer by primary injection up to 100A all as directed.
Supply and repalce in repair of the following items
Breaker bushing contact
Bus bar Spout
Circuit spout
PT Plug contact
Supply only closing/ tripping coil of 11KV VCBs type VE 12,30 Volts
Supply & replace 11KV potential transformer TYPE VIR= 11000/RT3/110/RT3/110/RT3V, VA=100/50 VF; 1.2CONT&1.9 for 8 Hours, voltage transformer single phase type HSV/IL, 12/28/75 KV all as specified
SRI SRK ENGINEERS
M/S CHANDRA ENGINEERS AND CONTRACTORS
MVV Prasad
M/s NATIONAL ENGINEERING CONSTRUCTIONS CO
ANAND ENTERPRISES AND ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .